SKY SEAL

SKY SEAL is a 1978 freight ship. The Coast Guard has recorded 33 inspections since 2016, most recently in November 2023, along with 87 deficiencies and 4 operational controls.

Records from 2016 to 2023. Most recent: inspection, 5 November 2023.

Built
1978
Last inspected
5 November 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 November 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7802691
Flag
TOGO
Maury page id
psix-49999

Documentation record

Tonnage as PSIX records it1514 - Displacement, Ton
791 - Dead Weight, Ton
254 - Regulatory (Subpart C or D), Gross Ton
658 - Convention (Subpart B), Gross Ton
176 - Regulatory (Subpart C or D), Net Ton
197 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

5 November 2023 Deficiency Check · CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7818231
12 March 2023 PSC A · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7648931
16 August 2022 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7531515
8 February 2022 PSC A · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7390794
25 July 2021 CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7264506
29 November 2020 CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7102321
29 November 2020 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7121208
26 April 2020 CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6942978
19 October 2019 CCSSC Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6836315
13 July 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6748054
16 June 2019 Ballast Water Examination · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6713725
19 February 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6627143
28 January 2019 ISPS III Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6615373
15 August 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6511435
1 August 2018 CCSSC Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6492596
25 April 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6398091
12 April 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6388710
16 March 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6369065
20 February 2018 Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6351890
23 May 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6153732
19 April 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6127258
5 April 2017 PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6116951
28 December 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6062600
23 November 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6046476
3 November 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6054648
2 November 2016 Ballast Water Examination · NPV Safety Exam · Deficiency Check · ISPS II Exam · CCSSC Examination · ISM Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033703
15 September 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6001693
7 September 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5994324
24 August 2016 PII Safety Exam · Ballast Water Examination · CCSSC Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5980753
18 May 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5879702
4 May 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5863146
30 March 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5842907
16 March 2016 ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5833497

Deficiency record · 87

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 November 2023 Resolved
Every ship should be sufficiently manned from the point of view of safety of life at sea. Crew was unable to complete and unfamiliar with duties of the fire and abandon ship drills. CCSS Code 1.7
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 5 November 2023 Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. 04 EEBD’s on board have expired in September of 2023 and 01 EEBD expired in JUL2023. CCSS Code 1.11.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 November 2023 Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. Vessel mast has not signed the vessel log book from 02OCT2023 to 04NOV2023. CCSS Code 1.11.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 November 2023 Resolved
Ready means of escape to the open deck shall be provided for all spaces in which the crew is normally employed. 02 pieces of exercise equipment (01 treadmill and 01 elliptical) are obstructing the means of escape on deck 02 leading to the starboard side of the vessel. CCSS Code 3.16.4.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 5 November 2023 Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. The portable two way radios, model SAMYUNG STV-160 as listed on the CCSSC have back up batteries that expired in October 2023. CCSS Code 1.11.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2023 Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. AC unit on port and starboard side of bridge was renewed and secured with ratchet straps. Permanently affix AC unit to mounting bracket. Old AC unit on port side is currently sitting loose and requires proper disposal. CCSS Code 1.11.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 November 2023 Resolved
Electrical installations should be installed and protected as to reduce to a minimum any danger to persons on board. Electrical breaker box and switch on port side of bridge is waste and engine room electrical switch board is missing blanks presenting an electrical hazard. CCSS Code 2.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2023
Resolved 8 November 2023
Resolution: Deficiency was rectified by the vessel as evidenced in Flag Report
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 29 November 2020 Resolved
A HAZMAT employee must recieve the training required by this subpart at least once every three (3) years. the master's HAZMAT training has expired and no ther crew had the required training. 49CFR172.704(c)(ii)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 29 November 2020
Resolution: Vessel provided documentation attesting HAZMAT training is current.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 16 June 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2019
Resolution: Administration provided endorsement for the Chief Mate.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2019 Resolved
The ballast pump may be accepted as the required fire pump. The gate valve which isolates the main service fire pump when closed will not re-open and sticks in the closed position. The emergency fire pump operates properly with the gate valve in the closed position. The ballast pump is arranged so that it can be used as the main fire pump. CCSSC 3.3.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2019
Resolved 13 July 2019
Resolution: PSCO attended the vessel and witnessed proper functioning of the valve and fire main.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2019 Resolved
Electrical installations should be such that electrical services essential for safety will be assured under emergency conditions. Newly installed emergency lighting in engineering spaces were not wired properly. Electrical plugs were not wired onto the emergency lights and did not operate when tested on three emergency lights. CCSSC 2.31.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2019
Resolved 16 June 2019
Resolution: Vessel installed plugs on the three emergency lights, lights verified operational.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 January 2019 Resolved
Nautical charts shall be adequate and up to date. Nautical chart for Yabucoa, PR was not up to date. 74 SOLAS 2014 V/27.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2019
Resolved 28 January 2019
Resolution: The company procured a new nautical chart for Yabucoa, PR.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 28 January 2019 Resolved
All fire protection systems and appliances shall at all times be in good order. One of the portable fire extinguishers was over charged CCSSC 3.6.12.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2019
Resolved 19 February 2019
Resolution: satisfactory service report of fire extinguishers received from Liferafts Inc. of Puerto Rico
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 1 August 2018 Resolved
While ships are operating within an emission control area, the sulphur content of fuel oil used on board ships shall not exceed the following limits: 0.10% m/m on or after 01Jan2015. Over a dozen bunker delivery notes, dating back to 29Mar2017 state sulphur content of the fuel must be verified and confirmed via either a statement from the supplier or a test of the sample from the vessel's fuel oil service tank.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2018
Resolved 1 August 2018
Resolution: Received statement from fuel supplier stating admin staff had copied and pasted kg/mg value from bulk fuel analysis report without converting to % m/m as required on vessel bunker delivery notes. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018 Resolved
The owner or master of every ship to which this code applies shall ensure that the condition of the ship and it's equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to procees to sea without danger to the ship, persons on board or the enviroment. Water pipe was fractured on the engine producing approximately 10 drops per second (outboard aft port side).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 29 August 2018
Resolution: Verified deficiency corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 1 August 2018 Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. The SMS designates enviromental protection responsibilities to the master; however, it does not specify sulphur content for fuel. Crew recieved bunker delivery notes for non-compliant sulphur content in fuel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 29 August 2018
Resolution: Verified deficiency corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 August 2018 Resolved
The company should ensure that all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations, codes and guidelines. All crew members shall cooperate for safe operations of recieving and transferring fuel and oil. Crew members were not familiar with the correct low-sulphur level.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 29 August 2018
Resolution: Verified deficiency corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 1 August 2018 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and the protection of the enviroment. The various tasks should be defined and assigned to qualified personnel. The chief engineer shall be responsible for coordination with the supplier the fuel characteristics including specific gravity and temperature. Checklist does not provide sulphur content.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 29 August 2018
Resolution: Verified deficiency corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 1 August 2018 Resolved
The company should carry out internal safety audits onboard and ashore at intervals not exceeding twelve months to verify whether safety and pollution-prevention activities comply with the safety management system. In exceptional circumstances, the internal may be exceeded by nit more than three months. The last two internal audits did not resolve issue with checklist not having required low-sulphur content.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 29 August 2018
Resolution: Verified deficiency corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. The vessel does not have proof of hydrostatic testing in the last two years.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2018
Resolution: Received proof of bunker line hydrostatic test.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
Master of any vessel equipped with ballast water tanks that operates in the waters of united states must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy. Plan contains multiple sections that are blank and contains the old NBIC reporting form.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2018
Resolved 29 August 2018
Resolution: Verified deficiency corrected.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 25 April 2018 Resolved
Subject to the provisions of paragraph 4 and 7, the Administration shall ensure that every ship constructed before 1 February 1995: after 1 February 1999, complies with all the applicable requirements of this chapter. 74 SOLAS 1997 Cons., Ch. IV / Reg. 1.5.2, Resolution A.1073(28)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 18 June 2018
Resolution: The RO issued the certificate.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 25 April 2018 Resolved
All ships of 300 gross tonnage and over to which this code applies shall comply with the provisions of Chapter IV of the SOLAS Convention as amended. The Caribbean Cargo Code defines "gross tonnage" as international tonnage as per CCSSC 1.1.11. The vessel's international gross tonnage is 631; however, the Administration has not issued a certificate attesting to compliance with Chapter IV. CCSSC 5.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 18 June 2018
Resolution: The RO issued the certificate.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 February 2018 Resolved
Except as permitted by the Administration in exceptional circumstances, all metal sheaths and armor of cables should be electrically continuous and should be earthed. Observed damaged and exposed cables on the port side cargo deck spot light. CCSSC 2.27.5.1
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 March 2018
Resolution: Received satisfactory class report.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 February 2018 Resolved
Main and emergency switchboards should be so arranged as to give easy access as may be needed to apparatus and equipment without danger to personnel. The switch boards should be suitably guarded as deemed necessary by the Administration. Main switchboard has exposed wiring. CCSSC 2.27.2
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 March 2018
Resolution: Verified appropriate corrective action.
Communications › Visual Communication › Signalling Lamp
Issued 20 February 2018 Resolved
A daylight signaling lamp or other means to communicate by light during day and night using an energy source of electrical power not solely dependent upon the ship's power supply. Daylight signaling lamp is not operational and does not have a portable emergency power battery. 74 SOLAS (14) V-19.2.2.2 / IMO Resolution MSC.95(72)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2018
Resolved 17 April 2018
Resolution: Verified the deficiency was corrected.
Operations/Management › Navigation Safety › Pilot(s)
Issued 20 February 2018 Resolved
All arrangements used for pilot transfer shall efficiently fulfill their purpose of enabling pilots to embark and disembark safely. The appliances shall be kept clean, properly maintained, and stowed to ensure that they are safe to use. Bottom several rungs are broken on pilot ladder. 74 SOLAS (14) V-23.2.1, CCSSC 6.2.6
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 March 2018
Resolution: Verified appropriate corrective action.
Fire Fighting › International Shore Connection › Connection
Issued 20 February 2018 Resolved
The owner of master of every ship to which this code applies should ensure that after any survey of the ship under 1.10 has been completed, no significant change should be made in the structural arrangement, machinery, equipment and other items covered by the survey, without the permission of the administration. Due to a valve failure the international shore connection is not currently accessible by shore side personnel. CCSSC 1.11.2
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 March 2018
Resolution: Verified appropriate corrective action.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 February 2018 Resolved
All ships of 150 gross tonnage and upwards shall be fitted with a bridge navigational watch alarm system (BNWAS), as follows: cargo ships of 500 gross tonnage and upwards not later than the first survey after 1 January 2017. The vessel underwent a credit drydock in August 2017 and a BNWAS was not installed. 74 SOLAS (14) Ch. V/Reg 19 2.2.3, IMO Resolution MSC.350(92)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2018
Resolved 12 April 2018
Resolution: Verified installation and operation of BNWAS onboard.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 February 2018 Resolved
Ship owners shall effect a shore-based radio equipment maintenance contract with a service supplier authorised by the administration or recognized by the administration or recognized organzation for the performance of this function. The vessel does not have a shore-based maintenance contract. CCSSC 5.5.2
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 March 2018
Resolution: Verified appropriate corrective action.
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 19 April 2017 Resolved
The vessel is required to have an LRIT Conformance Test Report. The vessel does not have an LRIT Conformance Test Report. 50bc
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 10 May 2017
Resolution: Received and vetted an LRIT Conformance Test Report from a technician company authorized to issue the report on the Flag State's behalf.
Lifesaving › Rescue Boat Equipment › Binnacle/Compass
Issued 5 April 2017 Resolved
Rescue boat did not have a functional binnacle compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2017
Resolution: A compass was provided onboard.
Fire Fighting › Fire Pumps › Power Source
Issued 5 April 2017 Resolved
Main fire pump was inoperable and troubleshoot operations took approximately one hour.
Action required: 705 - Other - as specified
Resolved 5 April 2017
Resolution: The crew proved operation of the main fire pump.
Personnel › Training › Fire Fighting Basic
Issued 5 April 2017 Resolved
Personnel could not operate the emergency fire pump in a timely manner.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 19 April 2017
Resolution: Crew conducted training and proved quick operation of the emergency fire pump.
Stability › Watertight Integrity › General
Issued 5 April 2017 Resolved
Weathertight door to house on main deck could not be closed weathertight.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 19 April 2017
Resolution: Maintenance was performed on the weathertight door and it was able to close weathertight.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 5 April 2017 Resolved
Ramp pin was missing.
Action required: 705 - Other - as specified
Resolved 5 April 2017
Resolution: A pin was installed.
Personnel › Training › Fire Fighting Basic
Issued 5 April 2017 Resolved
The crew did not know how to properly don fire fighting equipment or avoid the simulated fire hazards.
Action required: 705 - Other - as specified
Resolved 5 April 2017
Resolution: The master provided training and the crew performed a satisfactory drill when given a second chance.
Documentation › Certificates/Documents › Document of Compliance (dangerous goods)
Issued 5 April 2017 Resolved
The segregation diagram was not ship specific.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 10 May 2017
Resolution: Received copies of page 2 and 3 which were ship specific and showed which classes of goods could be stowed onboard.
Stability › Water on Deck › General
Issued 5 April 2017 Resolved
Pump contaminated bilge water between lazarette and engine room.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 5 April 2017
Resolution: The crew pumped out the excessive water.
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 5 April 2017 Resolved
The dangerous cargo manifest was not signed by master or licensed deck officer designated by the master.
Action required: 705 - Other - as specified
Resolved 5 April 2017
Resolution: The master signed all the pages of the previous dangerous cargo manifest.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 5 April 2017 Resolved
The International Tonnage Certificate does not specify which interim scheme the ship-owner or Flag State would apply to the vessel for the purpose of MARPOL and SOLAS.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 April 2017
Resolution: Received revised second page on this date.
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 2 November 2016 Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-conformities. These discrepancies, included with the other material deficiencies, are evidence that the ship and/or company are not meeting the requirements of the ISM Code. Recommend an external audit. (See Form B) 74 SOLAS (14), Ch. IX/Reg 3.1, ISM Code 1.3.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 23 November 2016
Resolution: The managing director of the company Star Shipping sought the assistance of IMR in Miami, to help rectify their ISM system. SMS revised, Flag change to TOGO, Surveying company changed to Conarina.
Operations/Management › Drills/Instruction › Fire
Issued 2 November 2016 Resolved
A ship is subject to control by officers concerning the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with the essential shipboard procedures relating to the safety of ships. The crew failed to demonstrate shipboard firefighting proficiency when provided two opportunities to do so. 74 SOLAS (14), Ch.IX-1/Reg. 4.1.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 23 November 2016
Resolution: The crew has practiced and fireman is knowledgablein donning the firemn's suit. Crew is also more coordinated in exercising the drills.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 2 November 2016 Resolved
The Administration or organization recognized by it shall, before issuing the Safety Management Certificate, verify that the company and its ship-board management operate in accordance with the approved safety management system. The vessel's SMS on-board is not approved by the Administration or recognized organization. 74 SOLAS (14), Ch.IX/Reg. 4.3.
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 28 December 2016
Resolution: A PSCO attended the vessel and found the SMS manual was stamped approved by Conarina.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 November 2016 Resolved
The Administration shall satisfy itself that the general structural strength of the ship is adequate. A ballast tank deck plug wasted off, and there were loose emergency shut-off penetrations through the cargo deck into the watertight envelop of the ship. Seven cargo tie-down points had severely wasted shackles. ICLL 66/88, Annex I/Reg. 1(1).
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 23 November 2016
Resolution: The wasted deck plug was replaced witha new one.The loose deck emergency shut-offs have all been removed with watertight fittings.All ballast tanks with mahole covers on the main deck now have all their bolts and nuts and gaskets to ensure proper closure.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2016 Resolved
Guard rails shall be fitted around all exposed decks. The height of the guard rails shall be at least one meter from the deck. The wooden guard rails on the port and starboard side of the cargo deck are less than one meter. ICLL 66/88, Annex I/Reg. 25(2).
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 23 November 2016
Resolution: The wooden planks forming the removable bulkwark in way of the gangway and port and starboard side were increased, surpassing the 1 meter required measurement.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 November 2016 Resolved
The deck line shall be marked amidships on each side of the ship. The vessel does not have deck lines on either side. ICLL 66/88, Annex I/Reg. 4.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 23 November 2016
Resolution: Deck lines were installed and painted in contrasting colors.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 2 November 2016 Resolved
The International Load Line Certificate shall not be delivered to the ship until the surveyor acting under the provisions of Article 13 of the convention has certified that the marks are correctly and permanently indicated on the ship’s sides. The vessel was missing deck lines on both side of the ship and the lines and rings are not permanently marked on the starboard side. ICLL 66/88, Annex I/9.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 23 November 2016
Resolution: Deck lines, plimson marks and load line marks were permanently installed in contrasting color to the hull and in accordance with Load Line Certificate
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 November 2016 Resolved
The ring, lines and letters shall be permanently marked on the sides of the ship. The mark of assigning authority is the only permanently affixed mark on the starboard side: the Plimsol mark and lines are only painted and are not permanently affixed. ICLL 66/88, Annex I/8.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: Plimson marks were permanently affixed in contrasting colors to the hull.
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 2 November 2016 Resolved
Whenever there is a hazardous condition aboard a vessel, the vessel representatives shall immediately notify the nearest Coast Guard Sector Office or Group Office. No involved parties notified the Coast Guard after the failure of the alarm panel for fire detection and bilge high water level alarms affecting the periodically unmanned machinery space. 33 CFR 160.215.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The alarm panel was repaired and functioning properly. Master and [name withheld] are aware of of notifying the Coast Guard of any malfunctioning equipment.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 2 November 2016 Resolved
A minimum of two inspections of the outside of the ship’s bottom shall be carried out during any five year period. In all cases the interval between any two such inspections shall not exceed thirty-six months. The vessel was granted illegal dry-dock extensions. See Form B. CCSSC 1.10.1.5.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The Flag surveyor stated based upon review of dry-docking reports, the Administration will accept August 20, 2012 as the beginning of the new dry-dock cycle. The next dry-dock will be August 20, 2017.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 November 2016 Resolved
Doors fitted in machinery space boundaries shall, as far as practicable, be equivalent in resisting fire to the divisions forming such boundaries. The gasket for the door connecting the accommodation spaces to the engine room is wasted. CCSSC 3.17.5.8.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The gasket to the watertight door between the accomodation and engine room was replaced
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 2 November 2016 Resolved
Fixed fire detection and Fire Alarm Systems shall be installed in periodically unattended machinery spaces. The fire detection system alarm was inoperable. CCSSC 3.17.7.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: Fire detection system fixed and alarm panel repaired,tested and visually inspected.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 November 2016 Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having manned machinery spaces. The bilge alarm was inoperable. CCSSC 2.36.2.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The repairs on the alarm panel has now rendered the bilge alarm operational. Alarm tested and vasually inspected.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 2 November 2016 Resolved
The owner or Master shall ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board, or the environment. The batteries on the vessel’s port generator were expired and inoperable. CCSSC 1.11.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The port generator batteries were replaced with a new set.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 2 November 2016 Resolved
The normal equipment of every rescue boat shall consist of one electrical torch with one spare set of batteries and one spare bulb; whistle; first aid outfit; two buoyant rescue quoits with line; a search light; radar reflector; bailer; fire extinguishing equipment; and boat hook. The rescue boat did not have the required equipment as listed above. CCSSC 4.3.1, LSA Code 5.1.2.2, LSA Code 5.1.2.3.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 November 2016
Resolved 23 November 2016
Resolution: All appropriate equipment was supplied on board.
Lifesaving › Rescue Boat › Construction
Issued 2 November 2016 Resolved
Rescue boats shall be fitted with weather tight stowage for small items of equipment. The rescue boat’s stowage compartment was filled with rain water. CCSSC 4.3.1, LSA Code 5.1.1.11.
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 28 December 2016
Resolution: A PSCO attended the vessel and found new gasket material was installed around the rescue boat's weathertight compartment.
Lifesaving › Lifebuoys › Quantity
Issued 2 November 2016 Resolved
Ships to which this chapter applies shall carry not less than the number of lifebuoys determined according to the following table: 50 meters and over; eight lifebuoys. The vessel is required to have eight lifebuoys, and there are only seven on board. CCSSC 4.12.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: Vessel now has 4 lifebuoys without attachements, 2 lifebouys with smoke and lights and 2 with lights and buoyant ropes.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 November 2016 Resolved
Ships having periodically unattended machinery spaces shall, as far as practicable and reasonable in the opinion of the administration, comply with the applicable requirements of Chapter II-2, Part E, of the 1974 SOLAS Convention as amended for machinery spaces. The fire control plan does not show "A" class boundaries. CCSSC 2.37.1, 74 SOLAS (14), Ch. II-2/Reg. 15.2.4.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The fire plan was revised indicating A and B class bulkheads and doors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2016 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. There are exposed wires on the starboard main engine, port generator, windlass controller, and horn in front of the bridge. CCSSC 2.27.1.3.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The danling and exposed wire was removed and replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016 Resolved
The Master shall ensure the condition of the ship is maintained to conform to the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship. The vessel’s port generator expansion tank piping was severely corroded and found leaking at approximately one drip per second. CCSSC 1.11.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The vessel's port generator expansion tank piping was replaced with new piping.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 2 November 2016 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency, the operator must secure each Type III devices in a manner which prevents discharge of sewage. The overboard discharge valve was not locked or secured in any way. 33 CFR 159.7(c).
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: Vessel's overboard discharge valve is locked with a chain and padlock.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 2 November 2016 Resolved
No person shall conduct an oil transfer operation unless each drain and scupper is closed by mechanical means. Secondary containment did not have means of closure. 33 CFR 156.120(o).
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: Starboard and port spill containments boxes have new mechanical threaded drain plugs.
Lifesaving › Rescue Boat › Markings
Issued 2 November 2016 Resolved
In addition to complying with the requirements of paragraph 4.4.9, inflated rescue boats shall be marked with the serial number, the maker’s name or trademark and the date of manufacture. The rescue boat was missing the requirements of 4.4.9, and its required markings; the number of persons for which the lifeboat is approved, name, and port of registry of the ship. CCSSC 4.3.1, LSA Code 5.1.3.4.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: Vessel's name, number of persons approved and port of registry are painted onto the rescue boat port and starboard.
Lifesaving › Launching Appliances › Davit
Issued 2 November 2016 Resolved
Each launching appliance shall be so arranged that the fully equipped rescue boat can be safely launched. The falls were rubbing the davit arm. CCSSC 4.3.1, LSA 6.1.1.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2016
Resolved 23 November 2016
Resolution: The wire rope for the davit rests against the back of the davit when there is no tension in the wire rope. When launching, the rescue boat the rope is taunt and does not rub or touch the davit.
Communications › Visual Communication › Signalling Lamp
Issued 2 November 2016 Resolved
All vessels operating in Restricted area III and unrestricted shall be provided with an ALDIS lamp. The ALDIS lamp was not functioning at the time of inspection and the vessel has been issued a CCSSC with an unrestricted route. CCSSC 6.4.4.1.6.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: A new ALDIS lamp was provided on board.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 2 November 2016 Resolved
Simple operating instructions with a block diagram showing the change-over procedures for remote steering gear control system and steering gear power units shall be permanently displayed on the navigation bridge. The vessel did not have instructions or a diagram. CCSSC 6.5.9, 74 SOLAS (14), Ch. V/Reg. 26.3.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: Simple instructions for changeover steering procedures were provided on the bridge and at the emergency steering station.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 2 November 2016 Resolved
Accumulator batteries shall be suitably housed, and compartments used for their accommodation shall be properly constructed and efficiently ventilated. Two batteries were stored in a cabinet without ventilation on the bridge. CCSSC 2.27.9.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The Flag surveyor stated the gel-core batteries' location is acceptable to the Administration.
Documentation › Logs/Records › Logbook (official)
Issued 2 November 2016 Resolved
The master shall have made in the logbook the following entries: details of the voyage, at least every four hours; and the name of all seafarers employed on-board for each voyage. The bridge log did not include the required entries. CCSSC 7.3.1.2 & .6.
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 28 December 2016
Resolution: A PSCO attended the vessel and found the official log book was being maintained and included the required entries.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 November 2016 Resolved
Nautical publications shall be carried on-board and shall be adequate and updated. The publications Light List, IAMSAR Vol. III, Tide Tables, and Tide Current Tables were not up to date. CCSSC 6.3.2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: New publications were provided on-board.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 2 November 2016 Resolved
Every ship shall be provided with at least two anchors of sufficient weight, one which is provided with a chain cable of adequate strength and size and windlass of suitable size for the cable. During the test of the windlass, the anchor paid out without control. Several links had loose or missing spanners. CCSSC 2.9.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The worst section of chain was replaced, and the associated anchoring equipment was tested satisfactorily.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 November 2016 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being served. The starboard engine room ventilation stack weather-tight door is prevented from closure by permanently affixed in-port generator cable running through it. The port vent stack has a flange connection that cannot be closed. CCSSC 3.17.6.3.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: A permanent watertight penetration was installed in the starboard smoke stack to avoid passing through the weathertight door. In the port smoke stack, the flanged connection was secured with a threaded cap.
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 November 2016 Resolved
Except as otherwise provided every vessel shall be fitted with a suitable magnetic compass, and the compass shall be illuminated. The magnetic compass was not accurate or illuminated. CCSSC 6.4.1.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: A new magnetic compass was provided on board.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 2 November 2016 Resolved
The master of every ship shall ensure that the condition of the ship and its equipment is maintained with the provisions of this Code to ensure that the ship will remain fit to proceed to sea without danger to persons on board. The cooling water is leaking excessively from the starboard main engine. CCSSC 1.11.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The turbo jacket pipe for the cooling system, over the starboard main engine, was renewed with new piping.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 2 November 2016 Resolved
Within 12 hours before departure, the ship’s steering gear checks and tests shall include: the operation of the means of communication between the navigational bridge and steering gear compartment. The emergency steering station telephone was not loud enough for the crew to understand each other. CCSSC 6.5.9, 74 SOLAS (14), Ch. V/Reg. 26.2.3.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The radio telephone was serviced by a technician.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 2 November 2016 Resolved
In a ship in which oil fuel is used, the arrangements for the storage distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. There are excessive fuel oil leaks on the starboard main engine which has saturated the exhaust lagging, creating a potential fire hazard in the engine room. CCSSC 3.20.2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The breeder pipe over the starboard main engine had a loose connection causing leakage. The connection was tightened.
Fire Fighting › Combustible Materials › Insulation
Issued 2 November 2016 Resolved
Insulation materials in machinery spaces shall be non-combustible. The exhaust lagging on the starboard main engine is oil-saturated, creating a potential fire hazard in the engine room. CCSSC 3.17.2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The lagging was cleaned.
Fire Fighting › Firemans Outfit › Quantity
Issued 2 November 2016 Resolved
Where more than one fireman’s outfit is carried, they shall be stored in widely separated positions. The fireman outfits were stored in the same cabinet in the mess deck area and not in widely separated positions. CCSSC 3.11.5.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The firemen outfits were stored in separate places: one in the mess, one on the bridge.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 2 November 2016 Resolved
Conflict between Area Restriction and Operational Limitations on certificate. See Form B. CCSSC 1.1.20.2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2016
Resolution: The trading area on the CCSSC was limited to Restricted Area II.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 August 2016 Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. PSCO observed leaks in the engine room, specifically in the steering gear room, 01 generator, and 01 shaft seal that required maintenance.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 24 August 2016
Resolution: Vessel Shore support came aboard during exam and tightened leaking fittings.
Personnel › Training › Familiarization Training
Issued 24 August 2016 Resolved
A hazmat emplyer shall ensure that each of its hazmat employees is trained in accordance with the requirements prescribed in this subpart. PSCO observed deck crew did not possess required hazmat training for the handling of dangerous goods in U.S. ports
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 15 September 2016
Resolution: Received proper documentation attesting to the crew acquiring training required to handle HAZMAT.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 16 March 2016 Resolved
Every ship to which this chapter applies shall be provided with not less than 6 hand held red flare signals. PSCO observed that the vessel did not have any hand held red flares. (CCSSC 2015/4.14; 17c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2016
Resolved 16 March 2016
Resolution: Vessel purchased and now has on board the required 06 red hand-held signal flares.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 16 March 2016 Resolved
For each ship subject to regulations 5 and 6 of this annex, details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of bunker delivery notes that shall contain at least the information specified in Appendix V of this Annex. PSCO noted that the bunker delivery notes did not contain all required info from MARPOL Annex VI Appendix V.(AnnexVI/18.5, 50c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: vessel provided appropriate bunker delivery notes.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 16 March 2016 Resolved
The transfer procedures required by 33 CFR 155.720 must contain the items listed in 33 CFR 155.750. PSCO identified that the transfer procedures did not meet the requirements listed in 155.750. (33CFR155.750; Prior to bunkering in US, c)
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 4 May 2016
Resolution: Vessel provided tranfer procedures.
Documentation › Logs/Records › Required Logbook Entries (Annex VI-Related)
Issued 16 March 2016 Resolved
Each ship subject to Regulation 6.1 that has rechargeable systems that contain ozone-depleting substances shall maintain an ozone depleting substances record book. PSCO found that the vessel has an installed Halon 1301 system onboard but could not provide an ozone-depleting substances record book. (Cite: MARPOL Annex VI/ Reg. 12.6)
Condition: Improper/Lack of Maintenance
Due 16 April 2016
Resolved 4 May 2016
Resolution: Vessel provided Ozone-depleting substances record book.
Documentation › Logs/Records › Logbook (official)
Issued 16 March 2016 Resolved
No person may cause a vessel to enter into the navigable waters of the United States unless, before entering, its required equipment is tested per 33 CFR164.25. PSCO found that the ships pre-arrival checks were not incompliance with 33 CFR 164.25 (33CFR164.25, 40c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2016
Resolution: Vessel master provided proof of proper log entries related to required equipment testing as part of the ships pre-arrival checks.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 16 March 2016 Resolved
Each loading arm and each transfer pipe system must not leak water under static liquid pressure at least 1.5 times the maximum allowable working pressure. PSCO found that the vessel's transfer piping had not been hysrostatically tested in the last 5 years. (33CFR156.170 prior to bunkering in the US, c)
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 30 March 2016
Resolution: Vessel master provided proper documentation attesting to tests conducted to ships bunker piping.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.