← All vessels
SKY SEAL
SKY SEAL is a 1978 freight ship. The Coast Guard has recorded 109 inspections since 1988, most recently in November 2023, along with 229 deficiencies and 11 operational controls.
Records from 1988 to 2023. Most recent: inspection, 5 November 2023.
- Built
- 1978
- Last inspected
- 5 November 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 109
- Deficiencies
- 229 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
600226
7802691 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5VEQ8
49999
Flag
TOGO
—
Maury page id
psix-49999
Inspections, by type
…with no type recorded41
Years with a record
27 calendar years (1988–2023)
The 109 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it1514 - Displacement, Ton
791 - Dead Weight, Ton
254 - Regulatory (Subpart C or D), Gross Ton
658 - Convention (Subpart B), Gross Ton
176 - Regulatory (Subpart C or D), Net Ton
197 - Convention (Subpart B), Net Ton
791 - Dead Weight, Ton
254 - Regulatory (Subpart C or D), Gross Ton
658 - Convention (Subpart B), Gross Ton
176 - Regulatory (Subpart C or D), Net Ton
197 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 109
5 November 2023
Deficiency Check · CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7818231
12 March 2023
PSC A · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7648931
16 August 2022
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7531515
8 February 2022
PSC A · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7390794
25 July 2021
CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7264506
29 November 2020
CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7102321
29 November 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7121208
26 April 2020
CCSSC Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6942978
19 October 2019
CCSSC Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6836315
13 July 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6748054
16 June 2019
Ballast Water Examination · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6713725
19 February 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6627143
28 January 2019
ISPS III Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6615373
15 August 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6511435
1 August 2018
CCSSC Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6492596
25 April 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6398091
12 April 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6388710
16 March 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6369065
20 February 2018
Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6351890
23 May 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6153732
19 April 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6127258
5 April 2017
PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6116951
28 December 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6062600
23 November 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6046476
3 November 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6054648
2 November 2016
Ballast Water Examination · NPV Safety Exam · Deficiency Check · ISPS II Exam · CCSSC Examination · ISM Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033703
15 September 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6001693
7 September 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5994324
24 August 2016
PII Safety Exam · Ballast Water Examination · CCSSC Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5980753
18 May 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5879702
4 May 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5863146
30 March 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5842907
16 March 2016
ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5833497
28 October 2015
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5751326
14 October 2015
CCSSC Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5741234
25 January 2012
CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4231261
13 July 2011
CCSSC Examination · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3932518
2 February 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3937636
19 January 2011
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3928953
12 January 2011
Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3925271
10 November 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3888841
14 October 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3869888
7 October 2010
CCSSC Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3865085
30 March 2010
CCSSC Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3705608
28 January 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3671329
21 December 2009
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3653398
4 December 2009
CCSSC Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3644708
22 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3349434
25 October 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2521882
20 September 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2497202
7 September 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486311
19 August 2005
ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2467799
10 July 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2421286
28 June 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2406574
3 May 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2348113
28 January 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2282281
12 January 2005
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2273256
6 December 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2254393
2 November 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2233133
11 October 2004
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2218330
11 October 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2218394
17 September 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2198278
17 September 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2198465
14 September 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2198462
6 September 2004
Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2188242
6 July 2004
ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2123050
26 April 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2052904
23 March 2004
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2029585
14 October 2003
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1927304
14 October 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1928314
27 June 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1828609
18 March 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1758316
4 March 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1752877
11 September 2002
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1673983
9 July 2002
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1642640
4 June 2002
Re-Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1625548
4 June 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1630511
18 September 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 293897
14 August 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 293172
10 April 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 288911
30 October 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 823323
23 October 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 824000
15 September 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 824764
4 April 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 276754
22 February 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 275048
16 November 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 810531
26 October 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 434641
16 August 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1115882
25 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 426973
4 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425652
4 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 426137
10 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423518
11 August 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 419188
2 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418431
19 March 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 413889
18 January 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412243
13 November 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 409970
9 October 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 408796
18 September 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 408035
28 August 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 407434
10 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 405824
23 April 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 402924
20 March 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401731
20 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 400649
30 October 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396834
12 February 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387866
6 October 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 19398
10 February 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 364430
16 February 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329467
Deficiency record · 229
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 November 2023
Resolved
Every ship should be sufficiently manned from the point of view of safety of life at sea. Crew was unable to complete and unfamiliar with duties of the fire and abandon ship drills.
CCSS Code 1.7
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 5 November 2023
Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. 04 EEBD’s on board have expired in September of 2023 and 01 EEBD expired in JUL2023.
CCSS Code 1.11.1
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 November 2023
Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. Vessel mast has not signed the vessel log book from 02OCT2023 to 04NOV2023.
CCSS Code 1.11.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 November 2023
Resolved
Ready means of escape to the open deck shall be provided for all spaces in which the crew is normally employed. 02 pieces of exercise equipment (01 treadmill and 01 elliptical) are obstructing the means of escape on deck 02 leading to the starboard side of the vessel.
CCSS Code 3.16.4.1
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 5 November 2023
Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. The portable two way radios, model SAMYUNG STV-160 as listed on the CCSSC have back up batteries that expired in October 2023.
CCSS Code 1.11.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2023
Resolved
The master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code and will remain fit to proceed to sea without danger to the ship, and persons on board. AC unit on port and starboard side of bridge was renewed and secured with ratchet straps. Permanently affix AC unit to mounting bracket. Old AC unit on port side is currently sitting loose and requires proper disposal.
CCSS Code 1.11.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 November 2023
Resolved
Electrical installations should be installed and protected as to reduce to a minimum any danger to persons on board. Electrical breaker box and switch on port side of bridge is waste and engine room electrical switch board is missing blanks presenting an electrical hazard.
CCSS Code 2.3
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 29 November 2020
Resolved
A HAZMAT employee must recieve the training required by this subpart at least once every three (3) years. the master's HAZMAT training has expired and no ther crew had the required training. 49CFR172.704(c)(ii)(2)
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 16 June 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2019
Resolved
The ballast pump may be accepted as the required fire pump. The gate valve which isolates the main service fire pump when closed will not re-open and sticks in the closed position. The emergency fire pump operates properly with the gate valve in the closed position. The ballast pump is arranged so that it can be used as the main fire pump. CCSSC 3.3.4
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2019
Resolved
Electrical installations should be such that electrical services essential for safety will be assured under emergency conditions. Newly installed emergency lighting in engineering spaces were not wired properly. Electrical plugs were not wired onto the emergency lights and did not operate when tested on three emergency lights. CCSSC 2.31.2
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 January 2019
Resolved
Nautical charts shall be adequate and up to date. Nautical chart for Yabucoa, PR was not up to date. 74 SOLAS 2014 V/27.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 28 January 2019
Resolved
All fire protection systems and appliances shall at all times be in good order. One of the portable fire extinguishers was over charged CCSSC 3.6.12.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 1 August 2018
Resolved
While ships are operating within an emission control area, the sulphur content of fuel oil used on board ships shall not exceed the following limits: 0.10% m/m on or after 01Jan2015. Over a dozen bunker delivery notes, dating back to 29Mar2017 state sulphur content of the fuel must be verified and confirmed via either a statement from the supplier or a test of the sample from the vessel's fuel oil service tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018
Resolved
The owner or master of every ship to which this code applies shall ensure that the condition of the ship and it's equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to procees to sea without danger to the ship, persons on board or the enviroment. Water pipe was fractured on the engine producing approximately 10 drops per second (outboard aft port side).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 1 August 2018
Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. The SMS designates enviromental protection responsibilities to the master; however, it does not specify sulphur content for fuel. Crew recieved bunker delivery notes for non-compliant sulphur content in fuel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 August 2018
Resolved
The company should ensure that all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations, codes and guidelines. All crew members shall cooperate for safe operations of recieving and transferring fuel and oil. Crew members were not familiar with the correct low-sulphur level.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 1 August 2018
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and the protection of the enviroment. The various tasks should be defined and assigned to qualified personnel. The chief engineer shall be responsible for coordination with the supplier the fuel characteristics including specific gravity and temperature. Checklist does not provide sulphur content.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 1 August 2018
Resolved
The company should carry out internal safety audits onboard and ashore at intervals not exceeding twelve months to verify whether safety and pollution-prevention activities comply with the safety management system. In exceptional circumstances, the internal may be exceeded by nit more than three months. The last two internal audits did not resolve issue with checklist not having required low-sulphur content.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018
Resolved
Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. The vessel does not have proof of hydrostatic testing in the last two years.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018
Resolved
Master of any vessel equipped with ballast water tanks that operates in the waters of united states must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy. Plan contains multiple sections that are blank and contains the old NBIC reporting form.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 25 April 2018
Resolved
Subject to the provisions of paragraph 4 and 7, the Administration shall ensure that every ship constructed before 1 February 1995: after 1 February 1999, complies with all the applicable requirements of this chapter. 74 SOLAS 1997 Cons., Ch. IV / Reg. 1.5.2, Resolution A.1073(28)
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 25 April 2018
Resolved
All ships of 300 gross tonnage and over to which this code applies shall comply with the provisions of Chapter IV of the SOLAS Convention as amended. The Caribbean Cargo Code defines "gross tonnage" as international tonnage as per CCSSC 1.1.11. The vessel's international gross tonnage is 631; however, the Administration has not issued a certificate attesting to compliance with Chapter IV. CCSSC 5.1.1
Electrical › Electrical Distribution System (service) › Cable
Issued 20 February 2018
Resolved
Except as permitted by the Administration in exceptional circumstances, all metal sheaths and armor of cables should be electrically continuous and should be earthed. Observed damaged and exposed cables on the port side cargo deck spot light. CCSSC 2.27.5.1
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 February 2018
Resolved
Main and emergency switchboards should be so arranged as to give easy access as may be needed to apparatus and equipment without danger to personnel. The switch boards should be suitably guarded as deemed necessary by the Administration. Main switchboard has exposed wiring. CCSSC 2.27.2
Communications › Visual Communication › Signalling Lamp
Issued 20 February 2018
Resolved
A daylight signaling lamp or other means to communicate by light during day and night using an energy source of electrical power not solely dependent upon the ship's power supply. Daylight signaling lamp is not operational and does not have a portable emergency power battery. 74 SOLAS (14) V-19.2.2.2 / IMO Resolution MSC.95(72)
Operations/Management › Navigation Safety › Pilot(s)
Issued 20 February 2018
Resolved
All arrangements used for pilot transfer shall efficiently fulfill their purpose of enabling pilots to embark and disembark safely. The appliances shall be kept clean, properly maintained, and stowed to ensure that they are safe to use. Bottom several rungs are broken on pilot ladder. 74 SOLAS (14) V-23.2.1, CCSSC 6.2.6
Fire Fighting › International Shore Connection › Connection
Issued 20 February 2018
Resolved
The owner of master of every ship to which this code applies should ensure that after any survey of the ship under 1.10 has been completed, no significant change should be made in the structural arrangement, machinery, equipment and other items covered by the survey, without the permission of the administration. Due to a valve failure the international shore connection is not currently accessible by shore side personnel. CCSSC 1.11.2
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 February 2018
Resolved
All ships of 150 gross tonnage and upwards shall be fitted with a bridge navigational watch alarm system (BNWAS), as follows: cargo ships of 500 gross tonnage and upwards not later than the first survey after 1 January 2017. The vessel underwent a credit drydock in August 2017 and a BNWAS was not installed. 74 SOLAS (14) Ch. V/Reg 19 2.2.3, IMO Resolution MSC.350(92)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 February 2018
Resolved
Ship owners shall effect a shore-based radio equipment maintenance contract with a service supplier authorised by the administration or recognized by the administration or recognized organzation for the performance of this function. The vessel does not have a shore-based maintenance contract. CCSSC 5.5.2
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 19 April 2017
Resolved
The vessel is required to have an LRIT Conformance Test Report. The vessel does not have an LRIT Conformance Test Report. 50bc
Lifesaving › Rescue Boat Equipment › Binnacle/Compass
Issued 5 April 2017
Resolved
Rescue boat did not have a functional binnacle compass.
Fire Fighting › Fire Pumps › Power Source
Issued 5 April 2017
Resolved
Main fire pump was inoperable and troubleshoot operations took approximately one hour.
Personnel › Training › Fire Fighting Basic
Issued 5 April 2017
Resolved
Personnel could not operate the emergency fire pump in a timely manner.
Stability › Watertight Integrity › General
Issued 5 April 2017
Resolved
Weathertight door to house on main deck could not be closed weathertight.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 5 April 2017
Resolved
Ramp pin was missing.
Personnel › Training › Fire Fighting Basic
Issued 5 April 2017
Resolved
The crew did not know how to properly don fire fighting equipment or avoid the simulated fire hazards.
Documentation › Certificates/Documents › Document of Compliance (dangerous goods)
Issued 5 April 2017
Resolved
The segregation diagram was not ship specific.
Stability › Water on Deck › General
Issued 5 April 2017
Resolved
Pump contaminated bilge water between lazarette and engine room.
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 5 April 2017
Resolved
The dangerous cargo manifest was not signed by master or licensed deck officer designated by the master.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 5 April 2017
Resolved
The International Tonnage Certificate does not specify which interim scheme the ship-owner or Flag State would apply to the vessel for the purpose of MARPOL and SOLAS.
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 2 November 2016
Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-conformities. These discrepancies, included with the other material deficiencies, are evidence that the ship and/or company are not meeting the requirements of the ISM Code. Recommend an external audit. (See Form B) 74 SOLAS (14), Ch. IX/Reg 3.1, ISM Code 1.3.
Operations/Management › Drills/Instruction › Fire
Issued 2 November 2016
Resolved
A ship is subject to control by officers concerning the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with the essential shipboard procedures relating to the safety of ships. The crew failed to demonstrate shipboard firefighting proficiency when provided two opportunities to do so. 74 SOLAS (14), Ch.IX-1/Reg. 4.1.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 2 November 2016
Resolved
The Administration or organization recognized by it shall, before issuing the Safety Management Certificate, verify that the company and its ship-board management operate in accordance with the approved safety management system. The vessel's SMS on-board is not approved by the Administration or recognized organization. 74 SOLAS (14), Ch.IX/Reg. 4.3.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 November 2016
Resolved
The Administration shall satisfy itself that the general structural strength of the ship is adequate. A ballast tank deck plug wasted off, and there were loose emergency shut-off penetrations through the cargo deck into the watertight envelop of the ship. Seven cargo tie-down points had severely wasted shackles. ICLL 66/88, Annex I/Reg. 1(1).
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2016
Resolved
Guard rails shall be fitted around all exposed decks. The height of the guard rails shall be at least one meter from the deck. The wooden guard rails on the port and starboard side of the cargo deck are less than one meter. ICLL 66/88, Annex I/Reg. 25(2).
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 November 2016
Resolved
The deck line shall be marked amidships on each side of the ship. The vessel does not have deck lines on either side. ICLL 66/88, Annex I/Reg. 4.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 2 November 2016
Resolved
The International Load Line Certificate shall not be delivered to the ship until the surveyor acting under the provisions of Article 13 of the convention has certified that the marks are correctly and permanently indicated on the ship’s sides. The vessel was missing deck lines on both side of the ship and the lines and rings are not permanently marked on the starboard side. ICLL 66/88, Annex I/9.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 November 2016
Resolved
The ring, lines and letters shall be permanently marked on the sides of the ship. The mark of assigning authority is the only permanently affixed mark on the starboard side: the Plimsol mark and lines are only painted and are not permanently affixed. ICLL 66/88, Annex I/8.
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 2 November 2016
Resolved
Whenever there is a hazardous condition aboard a vessel, the vessel representatives shall immediately notify the nearest Coast Guard Sector Office or Group Office. No involved parties notified the Coast Guard after the failure of the alarm panel for fire detection and bilge high water level alarms affecting the periodically unmanned machinery space. 33 CFR 160.215.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 2 November 2016
Resolved
A minimum of two inspections of the outside of the ship’s bottom shall be carried out during any five year period. In all cases the interval between any two such inspections shall not exceed thirty-six months. The vessel was granted illegal dry-dock extensions. See Form B. CCSSC 1.10.1.5.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 November 2016
Resolved
Doors fitted in machinery space boundaries shall, as far as practicable, be equivalent in resisting fire to the divisions forming such boundaries. The gasket for the door connecting the accommodation spaces to the engine room is wasted. CCSSC 3.17.5.8.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 2 November 2016
Resolved
Fixed fire detection and Fire Alarm Systems shall be installed in periodically unattended machinery spaces. The fire detection system alarm was inoperable. CCSSC 3.17.7.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 November 2016
Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having manned machinery spaces. The bilge alarm was inoperable. CCSSC 2.36.2.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 2 November 2016
Resolved
The owner or Master shall ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board, or the environment. The batteries on the vessel’s port generator were expired and inoperable. CCSSC 1.11.1.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 2 November 2016
Resolved
The normal equipment of every rescue boat shall consist of one electrical torch with one spare set of batteries and one spare bulb; whistle; first aid outfit; two buoyant rescue quoits with line; a search light; radar reflector; bailer; fire extinguishing equipment; and boat hook. The rescue boat did not have the required equipment as listed above. CCSSC 4.3.1, LSA Code 5.1.2.2, LSA Code 5.1.2.3.
Lifesaving › Rescue Boat › Construction
Issued 2 November 2016
Resolved
Rescue boats shall be fitted with weather tight stowage for small items of equipment. The rescue boat’s stowage compartment was filled with rain water. CCSSC 4.3.1, LSA Code 5.1.1.11.
Lifesaving › Lifebuoys › Quantity
Issued 2 November 2016
Resolved
Ships to which this chapter applies shall carry not less than the number of lifebuoys determined according to the following table: 50 meters and over; eight lifebuoys. The vessel is required to have eight lifebuoys, and there are only seven on board. CCSSC 4.12.1.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 November 2016
Resolved
Ships having periodically unattended machinery spaces shall, as far as practicable and reasonable in the opinion of the administration, comply with the applicable requirements of Chapter II-2, Part E, of the 1974 SOLAS Convention as amended for machinery spaces. The fire control plan does not show "A" class boundaries. CCSSC 2.37.1, 74 SOLAS (14), Ch. II-2/Reg. 15.2.4.1.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2016
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. There are exposed wires on the starboard main engine, port generator, windlass controller, and horn in front of the bridge. CCSSC 2.27.1.3.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016
Resolved
The Master shall ensure the condition of the ship is maintained to conform to the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship. The vessel’s port generator expansion tank piping was severely corroded and found leaking at approximately one drip per second. CCSSC 1.11.1.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 2 November 2016
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency, the operator must secure each Type III devices in a manner which prevents discharge of sewage. The overboard discharge valve was not locked or secured in any way. 33 CFR 159.7(c).
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 2 November 2016
Resolved
No person shall conduct an oil transfer operation unless each drain and scupper is closed by mechanical means. Secondary containment did not have means of closure. 33 CFR 156.120(o).
Lifesaving › Rescue Boat › Markings
Issued 2 November 2016
Resolved
In addition to complying with the requirements of paragraph 4.4.9, inflated rescue boats shall be marked with the serial number, the maker’s name or trademark and the date of manufacture. The rescue boat was missing the requirements of 4.4.9, and its required markings; the number of persons for which the lifeboat is approved, name, and port of registry of the ship. CCSSC 4.3.1, LSA Code 5.1.3.4.
Lifesaving › Launching Appliances › Davit
Issued 2 November 2016
Resolved
Each launching appliance shall be so arranged that the fully equipped rescue boat can be safely launched. The falls were rubbing the davit arm. CCSSC 4.3.1, LSA 6.1.1.1.
Communications › Visual Communication › Signalling Lamp
Issued 2 November 2016
Resolved
All vessels operating in Restricted area III and unrestricted shall be provided with an ALDIS lamp. The ALDIS lamp was not functioning at the time of inspection and the vessel has been issued a CCSSC with an unrestricted route. CCSSC 6.4.4.1.6.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 2 November 2016
Resolved
Simple operating instructions with a block diagram showing the change-over procedures for remote steering gear control system and steering gear power units shall be permanently displayed on the navigation bridge. The vessel did not have instructions or a diagram. CCSSC 6.5.9, 74 SOLAS (14), Ch. V/Reg. 26.3.1.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 2 November 2016
Resolved
Accumulator batteries shall be suitably housed, and compartments used for their accommodation shall be properly constructed and efficiently ventilated. Two batteries were stored in a cabinet without ventilation on the bridge. CCSSC 2.27.9.1.
Documentation › Logs/Records › Logbook (official)
Issued 2 November 2016
Resolved
The master shall have made in the logbook the following entries: details of the voyage, at least every four hours; and the name of all seafarers employed on-board for each voyage. The bridge log did not include the required entries. CCSSC 7.3.1.2 & .6.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 November 2016
Resolved
Nautical publications shall be carried on-board and shall be adequate and updated. The publications Light List, IAMSAR Vol. III, Tide Tables, and Tide Current Tables were not up to date. CCSSC 6.3.2.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 2 November 2016
Resolved
Every ship shall be provided with at least two anchors of sufficient weight, one which is provided with a chain cable of adequate strength and size and windlass of suitable size for the cable. During the test of the windlass, the anchor paid out without control. Several links had loose or missing spanners. CCSSC 2.9.1.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 November 2016
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being served. The starboard engine room ventilation stack weather-tight door is prevented from closure by permanently affixed in-port generator cable running through it. The port vent stack has a flange connection that cannot be closed. CCSSC 3.17.6.3.
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 November 2016
Resolved
Except as otherwise provided every vessel shall be fitted with a suitable magnetic compass, and the compass shall be illuminated. The magnetic compass was not accurate or illuminated. CCSSC 6.4.1.1.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 2 November 2016
Resolved
The master of every ship shall ensure that the condition of the ship and its equipment is maintained with the provisions of this Code to ensure that the ship will remain fit to proceed to sea without danger to persons on board. The cooling water is leaking excessively from the starboard main engine. CCSSC 1.11.1.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 2 November 2016
Resolved
Within 12 hours before departure, the ship’s steering gear checks and tests shall include: the operation of the means of communication between the navigational bridge and steering gear compartment. The emergency steering station telephone was not loud enough for the crew to understand each other. CCSSC 6.5.9, 74 SOLAS (14), Ch. V/Reg. 26.2.3.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 2 November 2016
Resolved
In a ship in which oil fuel is used, the arrangements for the storage distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. There are excessive fuel oil leaks on the starboard main engine which has saturated the exhaust lagging, creating a potential fire hazard in the engine room. CCSSC 3.20.2.
Fire Fighting › Combustible Materials › Insulation
Issued 2 November 2016
Resolved
Insulation materials in machinery spaces shall be non-combustible. The exhaust lagging on the starboard main engine is oil-saturated, creating a potential fire hazard in the engine room. CCSSC 3.17.2.
Fire Fighting › Firemans Outfit › Quantity
Issued 2 November 2016
Resolved
Where more than one fireman’s outfit is carried, they shall be stored in widely separated positions. The fireman outfits were stored in the same cabinet in the mess deck area and not in widely separated positions. CCSSC 3.11.5.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 2 November 2016
Resolved
Conflict between Area Restriction and Operational Limitations on certificate. See Form B. CCSSC 1.1.20.2.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 August 2016
Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. PSCO observed leaks in the engine room, specifically in the steering gear room, 01 generator, and 01 shaft seal that required maintenance.
Personnel › Training › Familiarization Training
Issued 24 August 2016
Resolved
A hazmat emplyer shall ensure that each of its hazmat employees is trained in accordance with the requirements prescribed in this subpart. PSCO observed deck crew did not possess required hazmat training for the handling of dangerous goods in U.S. ports
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 16 March 2016
Resolved
Every ship to which this chapter applies shall be provided with not less than 6 hand held red flare signals. PSCO observed that the vessel did not have any hand held red flares. (CCSSC 2015/4.14; 17c)
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 16 March 2016
Resolved
For each ship subject to regulations 5 and 6 of this annex, details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of bunker delivery notes that shall contain at least the information specified in Appendix V of this Annex. PSCO noted that the bunker delivery notes did not contain all required info from MARPOL Annex VI Appendix V.(AnnexVI/18.5, 50c)
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 16 March 2016
Resolved
The transfer procedures required by 33 CFR 155.720 must contain the items listed in 33 CFR 155.750. PSCO identified that the transfer procedures did not meet the requirements listed in 155.750. (33CFR155.750; Prior to bunkering in US, c)
Documentation › Logs/Records › Required Logbook Entries (Annex VI-Related)
Issued 16 March 2016
Resolved
Each ship subject to Regulation 6.1 that has rechargeable systems that contain ozone-depleting substances shall maintain an ozone depleting substances record book. PSCO found that the vessel has an installed Halon 1301 system onboard but could not provide an ozone-depleting substances record book. (Cite: MARPOL Annex VI/ Reg. 12.6)
Documentation › Logs/Records › Logbook (official)
Issued 16 March 2016
Resolved
No person may cause a vessel to enter into the navigable waters of the United States unless, before entering, its required equipment is tested per 33 CFR164.25. PSCO found that the ships pre-arrival checks were not incompliance with 33 CFR 164.25 (33CFR164.25, 40c)
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 16 March 2016
Resolved
Each loading arm and each transfer pipe system must not leak water under static liquid pressure at least 1.5 times the maximum allowable working pressure. PSCO found that the vessel's transfer piping had not been hysrostatically tested in the last 5 years. (33CFR156.170 prior to bunkering in the US, c)
Engineering › Steering Gear System › Linkage
Issued 14 October 2015
Resolved
The condition of the ship and its equipment are maintained to the provisions of the Code to ensure that the vessel is fit to proceed to sea without danger. PSCO found the linkage on the auto pilot at steering room with excessive wastage. (CCSC 1.11)
Engineering › Sea-water System (primary cooling) › Valve
Issued 14 October 2015
Resolved
The condition of the ship and its equipment are maintained to the provisions of the Code to ensure the vessel is fit to proceed to sea without danger. PSCO found that the raw water intake/ sea suction had leakage.(CCSSC 1.11)
Lifesaving › Lifebuoys › Serviceable
Issued 12 January 2011
Resolved
The condition of the ship and it's equipment is maintained to conform with the provision of the code to proceed to sea without danger to the ship or persons onboard. During the inspection it was discovered that 4 lifebuoys were missing there plugs. This condition would allow the water to fill the lifebuoy.
code: 0650
cite: CCSSCODE 1.11.1
action: 40c
Engineering › Fuel Oil Service System › Filter
Issued 7 October 2010
Resolved
The No. 3 harbor generator missing flame guard on fuel oil Racor filter. All exposed surfaces should be protected from possible fire. CCSS Code CH 3, Part B 3.16.2
Engineering › Fuel Oil Service System › Pump
Issued 7 October 2010
Resolved
Fuel oil transfer pump leaking fuel through the seal. Fuel oil pump and associated piping used for the distribution of fuel oil shall be such as to ensure the safety of the ship and persons on board.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 7 October 2010
Resolved
Bow thruster starting motor is not operational. Vessel when fitted with supplementary means of maneuvering should be operational. CCSS Code Ch. 2 Part F 2.31.4
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 7 October 2010
Resolved
Turbocharger on port/stbd main engines and 1/2 generators missing insulation. Turbocharger to be properly insulated to protect vessel and crew from fire hazard. CCSS Code CH 3 Part B 3.16.3.1
Electrical › Electric Generation Source (service) › Generator
Issued 7 October 2010
Resolved
The No. 3 harbor generator windings heavily covered in soot causing a hazard to normal power. Also provide operational voltage, frequency and amperage gauges. CCSS Code Ch 2, Part E, 2.26.1
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 7 October 2010
Resolved
Main electrical distribution panel blanks missing on starting motor No. 1 and distribution panels A and B. The switchboard shall be guarded to protect personnel from any electrical hazard. CCSS Code Ch. 2, Part E, 2.27.2
Engineering › Steering Gear System › Rudder Bearing
Issued 7 October 2010
Resolved
Port side rudder stock section of bracket wasted. Bracket to be of adequate strength and sufficient for all foreseeable conditions and intended service.
Construction/Loadline › Structures › Superstructure
Issued 7 October 2010
Resolved
Port side ramp ram hydraulic leak. Vessel stern ramp hydraulic ram to be maintained according to survey. CCSS Code Ch 1, Part B, 1.11.1
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 October 2010
Resolved
Vessel's fire control plan showed four points where plan are posted, they were actually hydrants. The plan must match the layout and show correct safety and fire equipment on the vessel. CCSS Code Ch 3, 3.13
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 October 2010
Resolved
The No. 2 generator electrical box not secured. Electrical box to be secured from engine vibration. CCSS Code Ch. 2, Part E, 2.26
Deck/Cargo › Ballast › Vents
Issued 7 October 2010
Resolved
Port and STBD side ballast tank vent screens missing. Vessel to provide screens according to conditions after survey. CCSS Code Ch. 1, Part B, 1.11.1
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 7 October 2010
Resolved
Vessels ANOA information was incorrect. Vessel reported five (5) other than crew and there were only three (3) persons. Two of the crew members on the ANOA were not onboard. The company security officer reported was incorrect.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 30 March 2010
Resolved
Vessel fuel oil purifier is leaking excessively causing a fire hazard. Vessel shall repair prior to departure to the satisfaction of flag and USCG.
Construction/Loadline › Structures › Door
Issued 30 March 2010
Resolved
Vessel stern ramp is missing one of eight hinge pins and eight cotter pins used to secure hinge pins causing safety hazard. Structure shall be able to withstand all foreseeable conditions of the intended service.
Communications › Visual Communication › Signalling Lamp
Issued 30 March 2010
Resolved
Vessel shall be provided with at least one operable daylight signaling lamp. Vessel is equipped with two lamps that are not operable. Vessel shall repair or replace.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 30 March 2010
Resolved
Vessel is missing steering gear instructions on the bridge. Adequate information and instructions shall be posted for the safe operation of the vessel.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 30 March 2010
Resolved
Vessel's Document of Compliance (DOC) for ISM not on board. Vessel shall provide valid certificate prior to departure.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 30 March 2010
Resolved
Vessel engineering officer could not provide a flag endorsement or application to his national license. Vessel shall provide a valid endorsement or application prior to departure.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 December 2009
Resolved
Passageway leading from accommodation space to engine room has exposed piping crossing on top of the deck, causing a tripping hazard. Provide adequate means of transit through passage way to engine room, to provide for safe transit.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 December 2009
Resolved
Front of emergency generator with rotating belts and pulleys is exposed causing a safety hazard to the crew. Provide guard to cover all moving machinery.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 December 2009
Resolved
Battery for starting emergency generator is not secured properly. Remove from deck and secure it properly.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 January 2006
Resolved
33U.S.C.1321(j)(G)-The vessel owner/operator has not provided certification stating that response resources are available under contract to respond to the maximum extent practicable, to a worst case discharge.
33U.S.C.1321(j)(G)(i)-The NTVRP does not identify the volume and type of oil that would be involved in a worst case discharge.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 January 2006
Resolved
33U.S.C.1321(j)(G)(ii)-The NTVRP does not identify a qualified individual and his/her responsibilities including immediate contact with the NRC and the oil spill removal organization
33U.S.C.1321(j)(G)(iii)-The NTVRP identifies unclassified oil spill removal organizations for the San Juan COTP zone.
33U.S.C.1321(j)(G)(iv)-The NTVRP does not address drills or training.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2005
Resolved
Repair light fixture mounting that is hanging by its wires in crew cabin.
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 September 2005
Resolved
Repair communication phone within steering room.
Navigation › Piloting/Steering › Marine Charts
Issued 7 September 2005
Resolved
Replace/update charts to current and replace light list and update sailing directions
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 September 2005
Resolved
Repair/replace stair steps leading to port and starboard bridge wings.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005
Resolved
Repair hole in top of starboard gunnel rubrail.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 7 September 2005
Resolved
Translate oil procedures into working language of the crew.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2005
Resolved
Reinstall wiring into junction box of windlass.
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 14 September 2004
Resolved
Vessel failed to obey order from the COTP to depart port due to Hurricane.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 7 September 2004
Resolved
INSTALL STANDARD DISCHARGE CONNECTION AS PER 33 CFR 155.420, AND SEND REPORT OF SATISFACTORY REPAIR TO USCG UPON COMPLETION.
Engineering › Bilge Water Management System › Vent
Issued 7 September 2004
Resolved
REPAIR/REPLACE WASTED BALLAST VENT PIPE STBD SIDE, AFTERMOST VENT PIPE, AND SEND REPORT OF SATISFACTORY REPAIR TO USCG UPON COMPLETION.
Construction/Loadline › Structures › Door
Issued 7 September 2004
Resolved
REPAIR/REPLACE THE FOLLOWING DOORS. A. DOORS LEADING INTO ENGINE ROOM FROM GALLEY., B. BRIDGE FORWARD P/S DOORS., C. PORTSIDE AFERMOST BRIDGE DOOR AND FIX FRAME BULKHEAD WERE HOLED. SEND REPORT OF SATISFACTORY REPAIR TO USCG UPON COMPLETION.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2004
Resolved
REPAIR/REPLACE THE FOLLOWING STRUCTURAL MEMBERS. A. (3) DECK LONGITUDINALS PORT & STBD IN WAY OF STEERING GEAR., B. (2) STIFFENER BASES IN WAY OF STEERING GEAR., C. (2) BRACKETS IN WAY OF STEERING GEAR., D. TRAVERSE " I" BEAM HOLDING THE #2 BALLAST PUMP. SEND REPORT OF SATISFACTORY TO USCG UPON REPAIR.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 September 2004
Resolved
INSTALL NON-SKID MATERIAL IN WAY OF STEERING GEAR CONTROL STATION AND SEND REPORT OF SATISFACTORY REPAIR TO USCG UPON COMPLETION.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 September 2004
Resolved
REPAIR HOLE IN AFTERMOST PORTSIDE ENGINE BULKHEAD JUST BEHIND #1 MDE AND SEND REPORT OF SATIFACTORY REPAIR TO USCG UPON COMPLETION.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 September 2004
Resolved
REPAIR STBD SIDE ENGINE BULKHEAD WERE EXHAUST BRACKET AND BULKHEAD IS HOLED AND SEND REPORT OF SATISFACTORY REPAIR TO USCG UPON COMPLETION.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 7 September 2004
Resolved
ESTABLISH ISM/SMS AND SEND FLAG ADMINISTRATION REPORT TO USCG UPON COMPLETION.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 23 March 2004
Resolved
Repair/replace STBD side A/C junction box to the satisfaction of the administration prior to 23 April 2004.
Engineering › Generator (propulsion-electric)
Issued 23 March 2004
Resolved
Repair/replace tachometer wires in portside engine room prior to 23 April 2004. LEGACY COMPONENT DESC: Wiring
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Repair punctured hull stbd side aft ballast tank prior to departure to the satisfaction of the Administration. LEGACY COMPONENT DESC: Side Shell
Lifesaving › Buoyant Smoke Signals
Issued 23 March 2004
Resolved
Provide expiration dates of bridgewing smoke floats prior to departure from port. LEGACY COMPONENT DESC: Expiration Dates
Fire Fighting › Combustible Materials
Issued 23 March 2004
Resolved
Remove paint cans from engine room prior to departure from port. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Lifesaving
Issued 23 March 2004
Resolved
Permanently affix liferaft instructions in the vicinity of liferafts prior to departure from port. LEGACY COMPONENT DESC: Liferaft Instructions
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Vessel is to fax results of permanent repaired puncture in hull stbd side aft ballast tank. LEGACY COMPONENT DESC: Hull Plating
Accommodation/Occupational Safety › Cooking Systems
Issued 14 October 2003
Resolved
Clean and clear out all grease from filter and grease trap above stove range, prior to vessel's return to San Juan, P.R.
Electrical › Electric Supply System (service)
Issued 14 October 2003
Resolved
Cap off or remove exposed wires from removed radar, prior to 11/14/03. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 14 October 2003
Resolved
Blank off open circuit breaker slots in service panel in engine room. Prior to 11/14/03. LEGACY COMPONENT DESC: Panelboard
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 14 October 2003
Resolved
Provide STCW Endorsements of Chief Mate, prior to departure.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 14 October 2003
Resolved
Provide valid Caribbean Cargo Ship Safety Certificate, prior to departure.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 27 June 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses
Issued 17 March 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Lighting (service)
Issued 17 March 2003
Resolved
Repair/replace inoperative light bulbs in crew berthing and engine room prior to arrival at next U.S. port.
Navigation › Piloting/Steering
Issued 17 March 2003
Resolved
Have current compass deviation table available for Coast Guard inspection upon arrival to next U.S. port. LEGACY COMPONENT DESC: Compass Deviation Table
Engineering
Issued 17 March 2003
Resolved
Repair/replace RPM indicator on starboard side engine by 18 Apr. 03.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2003
Resolved
Repair/replace light fixture in steering compartment prior to arrival at next U.S. port.
Documentation › Certificates/Documents
Issued 4 June 2002
Resolved
PROVIDE RECORD OF EQUIPMENT REQUIRED TO ENDORSE THE CCSSC CERTIFICATE (RECORD OF EQUIPMENT FOR THE CCSS CERTIFICATE). PROVIDE REPORT FROM FLAG/CLASS TO THE MSO SJ PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Cargo Ship Safety Certificate
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 4 June 2002
Resolved
SERVICE 04 FIRE EXTINGUISHERS AND PROVIDE EVIDENCE TO THE MSO SJ PRIOR TO DEPARTURE FROM PORT. LEGACY COMPONENT DESC: Service
Lifesaving › Inflatable Liferafts
Issued 4 June 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents
Issued 4 June 2002
Resolved
PROVIDE EVIDENCE OF CERTIFICATE THE CARRIAGE OF DANGEROUS GOODS (FLAG ENDORSED).
Lifesaving › Buoyant Smoke Signals
Issued 4 June 2002
Resolved
ATTACH SMOKE SIGNAL TO RING BUOY, PORTSIDE
Lifesaving › Embarkation Appliances/Stations
Issued 4 June 2002
Resolved
PROVIDE INSTRUCTIONS TO LIFERAFT STATIONS (NO INSTRUCTIONS AT STATION).
Navigation › Piloting/Steering
Issued 4 June 2002
Resolved
REPAIR/REPLACE EMERGENCY LIGHTING ON STEERING (RUDDER) ROOM.
Electrical › Lighting (service)
Issued 4 June 2002
Resolved
PROVIDE PROTECTIVE INSULATION TO EXPOSED ELECTRICAL WIRES ON STEERING GEAR.
Electrical › Lighting (emergency)
Issued 4 June 2002
Resolved
REPAIR/REPLACE EMERGENCY LIGHTING ON PORT AND STARBOARD EMERGENCY ESCAPE EXIT ON ENGINE ROOM. LEGACY COMPONENT DESC: Lighting Fixture
Fire Fighting › Ventilation Systems
Issued 4 June 2002
Resolved
REPLACE WASTED VENTS ON PORT SIDE (TWO) UNDER LIFERAFT STATION AND STARBOARD SIDE (ONE) UNDER LIFERAFT STATION. LEGACY COMPONENT DESC: Ducts
Navigation › Piloting/Steering
Issued 4 June 2002
Resolved
REPAIR/REPLACE PORT MAIN DIESEL ENGINE RPM TACOMETER.
Lifesaving
Issued 14 August 2001
Resolved
EPIRB NEEDS TO BE REGISTERED. SOLAS 74 CH. IV
Lifesaving
Issued 14 August 2001
Resolved
EPIRB NEEDS TO BE MOUNTED OUTSIDE THE BRIDGE, CAPABLE OF FLOATING FREE.
Electrical
Issued 14 August 2001
Resolved
CORRECT ELECTRIC HAZARD OVER TOP RACKS IN DECK PERSONNEL BERTHING AREA. WIRES NEED TO BE INSIDE A JUNCTION BOX.
Electrical
Issued 14 August 2001
Resolved
CORRECT ELECTRIC HAZARDS IN ENGINEER'S BERTHING AREA. LIGHT FIXTURE OVER THE [name withheld] TO BE MOUNTED ON THE WALL.
Lifesaving
Issued 14 August 2001
Resolved
CAPACITY LIFESAVING EQUIPMENT ON BOARD IS INADEQUATE FOR TOTAL NUMBER OF PERSONS CARRIED, 21 PERSONS ONBOARD IN ADDITION TO THE CREW. THIS IS IN_x001C_ EXCESS OF PERSONS AUTHORIZED TO CARRY AS SHOWN ON THE VSL CCSS CERTIFICATE.
Electrical
Issued 14 August 2001
Resolved
EXPOSED LIVE WIRES INSIDE THE FROZEN WALK IN FREEZER NEEDS TO BE SECURED INSIDE THE EVAPORATOR AND TAPED AT THE END. CCSS CODE 2.31
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
EMERGENCY DOOR OPENER FOR WALKING FREEZER AND CHILLER BOX ARE INOPERABLE.
Construction/Loadline
Issued 22 February 2000
Resolved
PRIOR TO DEPARTURE REPAIR/RENEW STBD ENGINE ROOM ESCAPE HATCH
Construction/Loadline
Issued 22 February 2000
Resolved
RENEW/REPAIR BALLST TANK AIR PIPE COVER STBD SIDE NLT 22MAR00.
Fire Fighting
Issued 22 February 2000
Resolved
PROVIDE EMERGENCY FIRE PUMP IAW CCSSC 3.3.1.1 PRIOR TO DEPARTURE
Lifesaving
Issued 22 February 2000
Resolved
PRIOR TO DEPARTURE, REPAIR HOLES IN RESCUE BOAT, DEMONSTRATE OPERATION.
Construction/Loadline
Issued 22 February 2000
Resolved
PRIOR TO DEPARTURE, PROVIDE METHOD TO COVER ENGINE ROOM VENTS AS PER CCSSC 3.16.
Documentation
Issued 22 February 2000
Resolved
PROVIDE LIFERAFT CERTIFICATES, RADIO OPERATORS PERMIT, FIXED FIREFIGHTING SYSTEM SERVICING CERTIFICATES NLT 22MAR00.
Documentation
Issued 22 February 2000
Resolved
PRIOR TO DEPARTURE PROVIDE EVIDENCE OF REQUIRED ANNUAL SURVEY FOR CCSSC CERTIFICATE DUE 10/08/99.
Documentation
Issued 22 February 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 26 October 1999
Resolved
REMOVE FUEL FROM BILGES PRIOR TO RETURNING TO US WATERS. 33CFR 155.770
Fire Fighting
Issued 26 October 1999
Resolved
RECHARGE FIVE PORTABLE FIRE FIGHTING EXTINGUISHERS AND PROVIDE SERVICING REPORT PRIOR TO RETURNING TO US WATERS._x001C_ CCSSC CH3.3.6.8
Documentation
Issued 26 October 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering
Issued 4 February 1999
Resolved
REPLACE ALL FLAME SCREENS ON ALL FUEL VENTS WITH 30X30 MESH AND PROPERLY SEAT.
Construction/Loadline
Issued 4 February 1999
Resolved
REPAIR WASTAGE BELOW STARBOARD SIDE DOOR ON MAIN DECK TO SATISFACTION OF CLASS. PROVIDE SURVEY REPORT.
Engineering
Issued 4 February 1999
Resolved
REPLACE AFT PORT SIDE FUEL OIL VENT. VENT IS CURRENTLY STRUCTURALLY DESTROYED.
Documentation
Issued 4 February 1999
Resolved
PROVIDE EVIDENCE OF UPDATED ANNEX III (ATTACHMENT TO CCSS CERT.) IN ACCORDANCE WITH CCSSC CODE.
Construction/Loadline
Issued 4 February 1999
Resolved
REPLACE GASKET OR MAKE WATERTIGHT 04 BALLAST TANK COVERS ON MAIN DECK LOCATED APPROX. MID-SHIPS.
Lifesaving
Issued 4 February 1999
Resolved
PROVIDE GASKET FOR STBD SIDE LIFERAFT AT PAINTER OPENING IN CONTAINER. REPLACE PORT SIDE LIFE RAFT PAINTER.
Fire Fighting
Issued 4 February 1999
Resolved
PROVIDE FULL FIREMANS OUTFIT IN ACCORDANCE WITH SURVEY. FIREMAN'S OUTFIT MISSING SEVERAL ITEMS (I.E. SHOE COVERS, GLOVES ECT..)
Accommodation/Occupational Safety
Issued 4 February 1999
Resolved
REPLACE GLASS ON SECOND DECK PORT SIDE PORT HOLES.
Deck/Cargo
Issued 4 February 1999
Resolved
REPLACE GASKET ON PORT SIDE CHAIN LOCKER HATCH COVER.
Lifesaving
Issued 10 December 1998
Resolved
PROVIDE 406 E.P.I.R.B. REGISTRATION WITH NOAA OR FLAG AUTHORIZATION OR REGISTRATION.
Navigation
Issued 10 December 1998
Resolved
PROVIDE CURRENT UP TO DATE LOCAL CHARTS.
Lifesaving
Issued 10 December 1998
Resolved
PROVIDE VENTILATION COVERS FOR ENGINE ROOM VENTS (02) LOCATED AFT OF BRIDGEHOUSE.
Deck/Cargo
Issued 10 December 1998
Resolved
PROVIDE PORT SIDE ANCHOR.
Engineering
Issued 2 July 1998
Resolved
PROVIDE FLAME GUARDS TO RACOR FUEL FILTER WITH PLASTIC FUEL BOWLS.
Lifesaving
Issued 2 July 1998
Resolved
PROVIDE EVIDENCE OF PURCHASE FOR 2 CHILDREN PFD PRIOR TO DEPARTING PORT.
Unknown
Issued 18 January 1998
Resolved
RENEW HOLED PORTSIDE ENGINE ROOM ESCAPE HATCH COVER. CORRECT NO LATER 18MAR98.
Unknown
Issued 18 January 1998
Resolved
PROVIDE ON BOARD MEDICAL CERTIFICATES. VESSEL CORRECTED DEFICIENCY.
Unknown
Issued 18 January 1998
Resolved
PROVIDE EMERGENCY LIGHTING FOR P&S ENGINE ROOM EMERGENCY ESCAPE EXITS. DEFICIENCY CORRECTED.
Unknown
Issued 18 January 1998
Resolved
PROVIDE PANAMANIAN RADIO OPERATOR LICENSE. CORRECTED.
Unknown
Issued 18 January 1998
Resolved
MAKE CORRECT ENTRIES INTO OIL RECORD BOOK. CORRECTED
Unknown
Issued 18 January 1998
Resolved
PROVIDE CORRECT BRACKETS FOR PORTABLE FIRE EXTINGUISHERS. CORRECTED.
Unknown
Issued 18 January 1998
Resolved
PROVIDE COPY OF FIXED FIRE FIGHTING SYSTEM SERVICE CERTIFICATE. CORRECTED.
Unknown
Issued 18 January 1998
Resolved
DEMONSTRATE OPERATION OF MAIN ENGINE WATER HIGH TEMPERATURE AND LOSS LUBE OIL PRESSURE SHUTDOWNS. CORRECTED
Unknown
Issued 18 January 1998
Resolved
DEMONSTRATE RESCUE BOAT CAN BE LAUNCHED WITH FULL COMPLEMENT. CORRECTED
Unknown
Issued 18 January 1998
Resolved
WELD PINHOLE IN PORTSIDE ENGINE ROOM EMERGENCY ESCAPE EXIT FORWARD BULKHEAD. CORRECTED.
Unknown
Issued 18 January 1998
Resolved
INSTALL METAL BLANKS IN SHIP SERVICE GENERATOR ELECTRICAL SWITCH BOARD. CORRECTED.
Unknown
Issued 18 January 1998
Resolved
PROVIDE WATER TIGHT INTEGRITY IN ENGINE ROOM FORWARD BULKHEAD WHERE ELECTRICAL CABLES PASS THROUGH BULKHEAD. CORRECTED
Electrical
Issued 9 October 1997
Resolved
PROVIDE COVER FOR FAN ABOVE AIR COMPRESSOR IN ENGINE ROOM.
Electrical
Issued 28 August 1997
Resolved
INSTALL RUBBER MAT IN FRONT OF MAIN SWITCH BOARD.
Fire Fighting
Issued 28 August 1997
Resolved
REPLACE ENGINE ROOM FIRE HYDRANT VALVE.
Electrical
Issued 28 August 1997
Resolved
INSTALL LIGHT COVERS TO VARIOUS LIGHT FIXTURES THROUGH OUT THE SHIP..
Electrical
Issued 28 August 1997
Resolved
SECURE RECEPTACLES WITH COVERS IN PASSAGE WAY TO ENGINE ROOM.
Fire Fighting
Issued 28 August 1997
Resolved
PROVIDE SERVICE TO HALON SYSTEM.
Documentation
Issued 28 August 1997
Resolved
PROVIDE COPY OF SAFE MANNING CERTIFICATE.
Documentation
Issued 23 April 1997
Resolved
PROVIDE CERTIFICATE OF RESPONSIBILITY FOR OIL POLLUTION IAW 33 CFR 138.
Engineering
Issued 20 February 1997
Resolved
PROVIDE OIL TRANSFER PROCEDURES._x001C_ 33 C.F.R. 155.720_x001C_ _x001C_
Lifesaving
Issued 20 February 1997
Resolved
MARK RING BUOYS WITH VESSEL'S NAME AND APPLY RETRO-REFLECTIVE TAPE. _x001C_ 46 C.F.R. 94.15-15_x001C_
Fire Fighting
Issued 20 February 1997
Resolved
PROPERLY SERVICE PORTABLE FIRE EXTINGUISHERS._x001C_ 46 C.F.R. 95.50-10(a)_x001C_
Lifesaving
Issued 20 February 1997
Resolved
LIFERAFTS TO BE SERVICED AND STOWED PROPERLY._x001C_ 46 C.F.R.94.10-10_x001C_ CORRECT PRIOR TO 20MAR97
Construction/Loadline
Issued 20 February 1997
Resolved
RENEW WATERTIGHT WASTED KNIFE EDGE AT AFT MAIN DECK WATERTIGHT DOOR LOCATEDAT BOTTOM OF HOUSE-AFT._x001C_ ILLC_x001C_
Electrical
Issued 20 February 1997
Resolved
INSTALL METAL BLANKS IN ELECTRICAL SWITCHBOARD IN ENGINE ROOM._x001C_ 46 C.F.R.90-25_x001C_ _x001C_
Accommodation/Occupational Safety
Issued 20 February 1997
Resolved
PROVIDE PERSONNEL GUARD ON PORTSIDE, DIESEL FUEL PUMP SHAFT COUPLING IN ENGINE ROOM._x001C_ ILO 147_x001C_
Accommodation/Occupational Safety
Issued 20 February 1997
Resolved
PROVIDE A PROPERLY INSULATED ELECTRICAL WIRE AT JUNCTION BOX STUFFING TUBE FOR VESSEL'S SHORE POWER_x001C_ SUPPLY. _x001C_ 46 C.F.R. 96.05_x001C_
Fire Fighting
Issued 12 February 1996
Resolved
PROVIDE COVER FOR MAIN FIRE PUMP AND GENERAL SERVICE PUMP ROTATIG SHAFTS.
Navigation
Issued 12 February 1996
Resolved
REPLACE US CHARTS AND PUBS FOR AREA TRANSITING PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 12 February 1996
Resolved
REPLACE OR RENEW MAIN SUCTION PIPE FOR MAIN FIRE PUMP BY 12MAR96
Engineering
Issued 12 February 1996
Resolved
PROVIDE MECHANICAL MENA TO CLOSE SMALL DISCHARGE CONTAINMENT PRIOR TO NEXT US BUNKERING.
Lifesaving
Issued 12 February 1996
Resolved
replace or renew 10 life preservers prior to departure
Fire Fighting
Issued 12 February 1996
Resolved
REPLACE OR RE-INSPECT 6 PORTABLE FIRE EXTINGUISHERS PRIOR TO DEPARTURE.
Lifesaving
Issued 12 February 1996
Resolved
REPLACE OR SERVICE PRIMARY LIFERAFTS PRIOR TO DEPARTURE.
Documentation
Issued 12 February 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 10 February 1994
Resolved
OIL TRANSFER PROCEDURES
Engineering
Issued 10 February 1994
Resolved
VESSEL'S FUEL SMALL DISCHARGE CONTAINMENT HAS DRAINS CUT AT DECK LINE THAT CAN NOT BE CLOSED MECHANICALLY.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.