MAURY USCG vessel records Sign in
← All vessels

JUN JIE

JUN JIE is a 1999 freight ship. The Coast Guard has recorded 23 inspections since 2000, most recently in June 2016, along with 11 deficiencies and 2 operational controls.

Records from 2000 to 2016. Most recent: inspection, 27 June 2016.

Built
1999
Last inspected
27 June 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9209491 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-5000

Inspections, by type

…with no type recorded8
Years with a record 13 calendar years (2000–2016)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it74005 - Dead Weight, Ton
84545 - Displacement, Ton
38888 - Convention (Subpart B), Gross Ton
25413 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

27 June 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5911017
18 September 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5717880
28 October 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5011647
27 October 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5015174
19 December 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4210578
12 November 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3889729
9 October 2008 ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3336968
8 October 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3341176
8 October 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3347568
12 October 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3076916
8 May 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2924892
9 August 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2741846
23 August 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2472149
21 August 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2469783
22 October 2004 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2226932
22 October 2004 NPV Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2227748
22 October 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2227949
17 October 2004 ISPS III Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2222552
2 August 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2153913
7 July 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1838154
18 June 2002 MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1633269
15 February 2002 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1485066
17 April 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 276724

Deficiency record · 11

Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 October 2014 Resolved
9800 - Other (Clearly hazardous) - Ships are subject to control when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. Serious deficiencies in E/R clearly hazardous to safety and health. Provide C.A.P from company w/ concurrence from certificate issuing authority. SOLAS 74 (2009) XI-1/4
Action required: 705 - Other - as specified
Due 28 October 2014
Resolved 3 November 2014
Resolution: PSC NOLA received a class report from KR satisfying the requirement and verified in person.
Documentation › Logs/Records › Oil Record Book
Issued 28 October 2014 Resolved
1710-ORB-A ship is subject to inspection where there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to prevention of pollution by oil. Crew not filling out ORB IAW posted instructions and onboard copy of MEPC 1./Circ. 736. Provide C.A.P. with RO concurrence. MARPOL 73/78 Annex I/11 16a
Action required: 705 - Other - as specified
Due 11 November 2014
Resolved 3 November 2014
Resolution: PSC NOLA received a class report from KR satisfying the requirement and verified in person.
Engineering › Feedwater/Condensate Water System › Observation Tank
Issued 28 October 2014 Resolved
9800-Other (Clearly Hazardous)- Condition of ship and equipment shall be maintained. Glass viewing ports on cascade tank are painted over and a valve on side of tank is spraying scalding water. Provide C.A.P. with R.O approval. SOLAS 74a I/11(a) 16a
Action required: 705 - Other - as specified
Due 11 November 2014
Resolved 3 November 2014
Resolution: PSC NOLA received a class report from KR satisfying the requirement and verified in person.
Engineering › Steering Gear System › Piping
Issued 28 October 2014 Resolved
0936-Steering gear- Condition of ship and equipment shall be maintained. Steering gear not being maintained resulting in containment drain being completely full of hydraulic fluid and not draining due to obstruction. Provide C.A.P. with R.O approval. SOLAS 74a I/11(a) 16a
Action required: 705 - Other - as specified
Due 11 November 2014
Resolved 3 November 2014
Resolution: PSC NOLA received a class report from KR satisfying the requirement and verified in person.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 28 October 2014 Resolved
1199-Other (cargo)-All cargoes shall be in accordance with the cargo securing manual. Cargo Securing Manual approval letter is for the wrong administration. Provide clarification from RO. SOLAS 74a VI/A.5 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2014
Resolved 3 November 2014
Resolution: PSC NOLA received a class report from KR satisfying the requirement and verified in person.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 28 October 2014 Resolved
0110-SEC -After any survey of the shipunder regulations 7,8,9, or 10 no change shall be without the sanction of Admin. SEC Form E states vessel has two ARPAs. Further examination and interviews finds vessel only has one. Provide clarification from RO. SOLAS 74a I/11(b) 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2014
Resolved 3 November 2014
Resolution: PSC NOLA received a class report from KR satisfying the requirement and verified in person.
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 28 October 2014 Resolved
9900-Other (NCH)- Condition of ship and equipment shall be maintained. PSCO found self-closing sight glass valves intentionally gagged in open position w/ fabricated devices on Steering gear reservoirs. SOLAS 74 am I/11(a )
Action required: 705 - Other - as specified
Due 28 October 2014
Resolved 28 October 2014
Resolution: Wire gagging removed in presence of PSCO.
Lifesaving › Lifebuoys › Not on Board
Issued 12 November 2010 Resolved
Vessel is required to have two quick release lifebuoys with self-activating smoke signals and self-igniting lights on the bridge. Vessel's two lifebuoys on the bridge does not have self-activating smoke signals or self-igniting lights. 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2010
Resolution: Received purchase receipt from vessel for two self-activating smoke signals and two self-igniting lights for the lifebuoys on the bridge.
Personnel › Training › Fire Fighting Basic
Issued 23 August 2005 Resolved
Fire Drill Inadequate; Sprayed water w/out securing power; ventilation not secured; personnel in smoke area w/out SCBA; no fire boundary set.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2005
Resolved 24 August 2005
Resolution: Conducted Three fire Drills in the same location. Eventually, all deficient conditions of fire drill were satisfied.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 23 August 2005 Resolved
Hydrostatic release unit for liferafts not properly serviced in past 17months. Liferaft last serviced in March 2003.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2005
Resolved 29 August 2005
Resolution: Attended vessel, reviewed class report and servicing record. Release had been serviced w/ liferaft on 7MAR05.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 23 August 2005 Resolved
Starboard loadline insufficiently painted IAW ICLL 66 Reg 8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2005
Resolved 29 August 2005
Resolution: Attended vessel, viewed class report and verified loadline to be correctly marked/painted.