DOLORES CHOUEST

DOLORES CHOUEST is a 1978 freight ship. The Coast Guard has recorded 89 inspections since 1982, most recently in January 2025, along with 69 deficiencies.

Records from 1982 to 2025. Most recent: inspection, 27 January 2025.

Built
1978
Last inspected
27 January 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8225931 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCP8847
Flag
UNITED STATES
338678000
Maury page id
psix-50007

Inspections, by type

…with no type recorded7
Years with a record 42 calendar years (1982–2025)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)228.3 ft × 42.4 ft × 12.2 ft
Registered tonnagegross 294 / net 200
ITC dimensions (L × B × D)210.8 ft × 42.5 ft × 14.0 ft
ITC tonnagegross 1,067 / net 320
BuilderNORTH AMERICAN SHIPBLDG · LAROSE, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1067 - Convention (Subpart B), Gross Ton
294 - Regulatory (Subpart C or D), Gross Ton
320 - Convention (Subpart B), Net Ton
200 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCP8847MMSI 338678000 · active · voluntarily equipped · granted 24 January 2025, expires 6 February 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 89

27 January 2025 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8071254
24 July 2024 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7969741
8 March 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7876215
12 February 2024 Administrative Inspection · Annual Inspection · Excursion Permit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7867497
28 November 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7830720
28 November 2022 Examination of Repairs · Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7600714
12 August 2022 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7531471
7 January 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7378559
14 December 2021 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7367283
23 August 2021 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7294292
8 March 2021 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7151966
11 December 2020 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7110416
5 October 2020 Construction Oversight · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7071741
17 August 2020 Excursion Permit
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7035670
1 June 2020 Excursion Permit
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6966284
28 April 2020 Excursion Permit
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6944854
4 March 2020 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6920498
7 January 2020 Deficiency Check · Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6903629
18 December 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6876274
11 December 2019 MTSA Verification · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6868995
10 December 2018 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6592878
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512698
4 December 2017 Underwater Inspection in lieu of Drydock
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6317599
9 November 2017 MTSA/ISPS Verification · Examination of Repairs · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6304120
20 March 2017 MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6108135
11 January 2017 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6060185
27 June 2016 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5921897
14 January 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5797666
4 January 2016 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5785892
3 October 2014 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4998264
9 June 2014 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4884300
13 January 2012 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4224334
9 January 2012 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4222301
10 February 2011 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4039722
5 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3776210
3 March 2010 DAPI Audit · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3688274
17 February 2010 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3681956
29 December 2009 Drydock Extension
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3660117
8 January 2009 COI Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3389961
22 January 2008 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3146762
14 February 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2872461
10 January 2007 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2847577
17 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2751163
21 March 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2606321
6 February 2006 Annual Inspection · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2577988
11 January 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2262403
17 June 2004 MTSA/ISPS Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2101718
19 April 2004 Plan Review (Other than "T")
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2057978
15 January 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1996784
8 January 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1983863
23 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976044
3 January 2003 Annual Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1720450
7 January 2002 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1474927
3 January 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1369963
21 July 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1051955
8 January 2000 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417011
4 January 2000 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1467178
8 February 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1126613
21 January 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 786927
13 January 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 810037
7 January 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1381435
12 January 1998 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368545
2 January 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1407842
1 July 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 14800
12 January 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374499
10 August 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 9306
13 January 1995 MARPOL Annex II Examination · Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1360197
11 October 1994 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1174933
13 January 1994 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1164207
11 January 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377104
8 January 1993 Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1141638
24 February 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1258848
4 February 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1414051
29 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226919
9 April 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1218458
5 April 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 902897
1 August 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903848
6 February 1990 COI Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926532
20 April 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1194724
17 March 1989 MARPOL Annex II Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890689
19 April 1988 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1033694
20 March 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326577
30 January 1987 Drydock Extension
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316729
15 July 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005734
8 August 1985 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291418
13 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282250
8 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974249
11 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970857
24 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967468

Deficiency record · 69

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 March 2024 Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made and that the material and the workmanship of such repairs or renewals are in all respects effectively made; vessel was involved in an allision with a Navy RHIB vessel while docked at NAS Pensacola pier sustaining a 1.5 inch deep over 1 ft span deformation above the waterline on the stern side shell in way of the stbd #08 ballast tank. No other damage was reported. Vessel is to undergo ABS survey and damage assessment and provide report to Sector Mobile prior to vessel movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2024
Resolution: Damage survey conducted. No immediate repairs required.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 March 2024 Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made and that the material and the workmanship of such repairs or renewals are in all respects effectively made; vessel was involved in an allision with a Navy RHIB vessel while docked at NAS Pensacola pier sustaining a 1.5 inch deep over 1 ft span deformation above the waterline on the stern side shell in way of the stbd #08 ballast tank. Vessel underwent ABS survey and damage assessment and provided report to Sector Mobile. Vessel permitted to make permanent repairs no later than the next drydocking survey. Notify CG inspection office as CG inspector will need to oversee repairs.
Action required: 705 - Other - as specified
Due 1 October 2024
Resolved 24 July 2024
Resolution: Repair completed and visually inspected by [name withheld] witnessed by ABS per 398.1
08 - Alarms › N/A - No Subsystem › General alarm
Issued 13 February 2023 Resolved
The system must be arranged and installed that the presence of a fire may be reported from any of the protected spaces and be automatically registered visibly and audibly in the pilothouse or fire control station. There must also be an audible alarm in the engine room. The Engine Room did not have an audible alarm for the fire detection system. 46 CFR 95.05-1 (a) 46 CFR 76.35.15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 14 February 2023
Resolution: Vessel added General Alarm speaker in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 February 2023 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work. Fire control: general arrangement plans showing for each deck the control stations, the various fire sections enclosed by the fire resisting bulkheads, the arrangement of the alarm and extinguishing systems, ventilation systems, details of the alarm system, and details of the extinguishing system. The approved General Arrangement Plan dated 26MAY2015 only shows a stove top. It does not reflect the Deep Fat Fryer which is on-board. A new ventilation hood was install which services the stove and the Deep Fat Fryer. Submit plan reviews to MSC for approval to address the new equipment on-board, electrical installation, and any needed fire fighting equipment. Provide an updated approved Fire Safety Plan to the CG which addresses the alternation of the galley equipment. 46 CFR 91.55.10(a)
Action required: 705 - Other - as specified
Due 12 April 2023
Resolved 20 March 2023
Resolution: Received complete work order that the Deep Fat Fryer has been locked-out.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 11 December 2019 Resolved
Signaling unit shall be energized from a self contained storage battery. Vessel's day light signal lamp battery is inoperable. 46 CFR 111.75-15(h).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 18 December 2019
Resolution: Vessel obtained new battery for day light signal lamp and proved proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 11 December 2019 Resolved
Each cargo vessel must carry an immersion suit approved under 160.171 of an appropriate size. Master's jumbo sized was not Coast Guard approved. 46 CFR 199.273.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 18 December 2019
Resolution: Vessel obtained 02 jumbo immersion suits that are approved under 46 CFR 160.171
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 December 2019 Resolved
Each liferaft must be arranged for float free launching. Vessel's weak link on the stbd side #3 liferaft was broken. 46 CFR 199.130(c)(7).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 18 December 2019
Resolution: Vessel obtained new wire type weak link for their liferaft. Vessel showed inspectors satisfactory evidence through emails from Vane Brothers that the weak link has a breaking strength of 500lbs. Same breaking strength of the weak link that was replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 December 2019 Resolved
Each class 1 door on a vessel in ocean service must be designed to withstand a head of water. The starboard aft engineroom watertight door is not watertight along bottom. Repair or replace to the satisfaction of attending marine inspector. 46CRFR170.270(b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 21 January 2020
Resolution: Watertight door sill replaced during drydock and MI witnessed satisfactory chalk test.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 December 2019 Resolved
Bilge and ballast piping must be so arranged as to prevent oil or water from the sea or ballast system from passing into machinery spaces. Ballast pipe in port side Z drive alley has a temporary patch. Repair to the satisfaction of attending Marine Inspector. 46CFR56.50-50(h)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 21 January 2020
Resolution: Pipe was replaced and tested to the satisfaction of attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 December 2019 Resolved
Means shall be provided for closing all ventilators. The port forward engine room vent closure was not operable. Repair to the satisfaction of attending Marine Inspector. 46CFR92.15-10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 December 2019
Resolution: Crew found that the reset cable had jumped a sheave and prevented the release cable from operating. Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 21 January 2020
Resolution: Verified vessel is now transmitting proper length.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 28 November 2017 Resolved
Gangway Load Test post visual inspection, found multiple cracks in the structural welds. Repair or replace Gangway and conduct a load test to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Satisfactory weld repairs and weight test.
Construction/Loadline › Hull › Side Shell
Issued 29 June 2016 Resolved
Port chain locker was found to have several clad weld repairs and severe pitting throughout an insert on the side shell. The insert is approximately 5' x 12' spanning from aft of frame 2 to aft of frame 6. Crop and renew this insert to also include severe pitting found just aft of the existing weld seam on this insert, during the next scheduled dry dock availability to the satisfaction of the CGMI
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 29 November 2017
Resolution: Port and stbd chain locker pitted and wasted steel replaced SAT.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2016 Resolved
Vessel has reported a hole in the anchor chain locker, accompanied by seawater ingress. Contact CG MI to inspect damage extent. Submit a repair proposal for approval & completion to the satisfaction of the attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 29 June 2016
Resolution: Repair proposal was reviewed by attending [name withheld] to be cropped and renewed were marked and ABS concurs.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 4 January 2016 Resolved
The air stop solenoid on the #1 SSDG does not actuate when overspeed condition sensed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 15 January 2016
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 4 January 2016 Resolved
The number 1 ssdg circuit breaker does not open when the "open breaker" switch pushbutton on the swbd is pressed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 14 January 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 January 2012 Resolved
Install guards over rotating machinery near the front of both MDEs.
Condition: Improper Installation
Due 9 February 2012
Resolved 13 January 2012
Resolution: Guards on MDEs installed.
Engineering › Fuel Oil Service System › Filter
Issued 9 January 2012 Resolved
Repair broken racor filter bowl mount on #2 MDE.
Condition: Improper/Lack of Maintenance
Due 23 February 2012
Resolved 13 January 2012
Resolution: Bowl mounted
Engineering › Fuel Oil Service System › Filter
Issued 9 January 2012 Resolved
Repair broken fuel filter bracket on #2 MDE.
Condition: Improper/Lack of Maintenance
Due 23 February 2012
Resolved 13 January 2012
Resolution: Bracket repaired.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 7 January 2009 Resolved
Prove proper safe manning prior to leaving port Hampton Roads to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2009
Resolution: Vessel proved proper safe manning as required to the satisfaction of attending Coast Guard marine inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 February 2006 Resolved
Repair exhaust leak on the # 1 MDE exhaust system to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 20 March 2006
Resolution: Replaced exhaust bellows on #1 MDE exhaust system.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 January 2004 Resolved
Post most recently CG approved fire control/safety plan on the vessel. The most recent plan was stamped approved by MSO Hampton roads dated 12 FEB 99
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 1 April 2005
Engineering › Pressure Vessel
Issued 8 January 2004 Resolved
Repair or renew stbd air receiver relief valve (175 psig). LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 8 February 2004
Resolved 15 January 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 January 2004 Resolved
Repair or renew stbd generator's battery charger. LEGACY COMPONENT DESC: Charger
Action required: 705 - Other - as specified
Due 15 January 2004
Resolved 15 January 2004
Accommodation/Occupational Safety › Heating
Issued 8 January 2004 Resolved
Install properly rated breakers and proper sized cable for both port and stbd engine room heaters rated for 24 amps. LEGACY COMPONENT DESC: Electric Air Heating Equipment
Action required: 705 - Other - as specified
Due 15 January 2004
Resolved 15 January 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 January 2002 Resolved
Unapproved lights found on two (02) jackets.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 January 2002
Resolved 7 January 2002
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 January 2002 Resolved
Retroreflective Material - Worn
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Replaced with new tape
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 January 2002 Resolved
Hole in jacket seam
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Took jacket out of service and replaced.
Lifesaving › Immersion Suits
Issued 7 January 2002 Resolved
Stencil vessel name
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Stenciled vessel name
Fire Fighting › Firemans Outfit
Issued 7 January 2002 Resolved
Put in proper location IAW Fire Control Plan
Action required: 705 - Other - as specified
Due 7 January 2002
Resolved 7 January 2002
Navigation › Piloting/Steering
Issued 7 January 2002 Resolved
Rudder angle indicator in steering gear room upside down.
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Replaced indicator in proper orientation IAW steering gear diagram
Navigation
Issued 4 January 2000 Resolved
PROVIDE DOCUMENTATION THAT INSTALLED GMDSS HAVE BEEN CERTIFIED BY FCC AUTHORIZED THIRD PARTY INSTALLER PRIOR TO USING GMDSS EQUIPMENT.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Lifesaving
Issued 4 January 2000 Resolved
REINSTALL TWO (2) TWENTY PERSON LIFERAFTS, ONE ON EACH SIDE OF VESSEL, PRIOR TO LEAVING THE SHIPYARD.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Lifesaving
Issued 7 January 1999 Resolved
REPLACE DETERIORATED RETROREFLECTIVE TAPE ON FIFTEEN (15) LIFEJACKETS AND ALL RINGBOUYS.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Fire Fighting
Issued 7 January 1999 Resolved
REPLACE ONE (1) 50 FT. LENGTH OF WORN FIREHOSE.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Fire Fighting
Issued 7 January 1999 Resolved
REPAIR OR REPLACE DAMAGED NOZZLE FOR FIRESTATION #1 FIREHOSE.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Lifesaving
Issued 7 January 1999 Resolved
REPLACE CHEMICAL LIGHTS ON ALL LIFEJACKETS AND IMMERSION SUITS WITH C.G. APPROVED LIGHTS.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Lifesaving
Issued 7 January 1999 Resolved
REPLACE DAMAGED RINGBOUY LOCATED STARBOARD SIDE AFT.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Lifesaving
Issued 7 January 1999 Resolved
UPDATE AND MAKE CORRECTIONS TO THE FIRE CONTROL PLAN AND PROVIDE TO MARINE SAFETY OFFICE HAMPTON ROADS FOR APPROVAL.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Engineering
Issued 12 January 1998 Resolved
INSTALL SAFETY RODS FOR SIGHT GLASS SOUNDING TUBES FOR BOTH OIL TANKS AND F/O TANK._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Electrical
Issued 12 January 1998 Resolved
REPAIR REVERSE POWER RELAY ON #2 S/S GENERATOR._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Construction/Loadline
Issued 12 January 1998 Resolved
RENEW WTD GASKET ON PORT DOOR TO SHAFT ALLEY._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Engineering
Issued 12 January 1998 Resolved
REPAIR OR RENEW BOTH F/O DAY TANK LEVEL SENSOR(LEAKING)._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Construction/Loadline
Issued 12 January 1998 Resolved
INSTALL ACCESS LADDER FOR #6 P & S BALLAST TANKS AND P & S POTABLE WATER TANKS (PRIOR TO NEXT DRYDOCK)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Construction/Loadline
Issued 12 January 1998 Resolved
SUBMIT REPAIR PLAN FOR SEWAGE TANK AREA AND REPAIR THE SAME AS PER APPROVEDPLAN._x001C_
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 12 January 1998 Resolved
PROVIDE TWO FULL SPARE AIR BOTTLES FOR FIREMAN OUTFIT._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Engineering
Issued 12 January 1998 Resolved
RENEW F/O LINE ON #1 MAIN ENGINE FILTER TO ENGINE._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Fire Fighting
Issued 12 January 1998 Resolved
REPAIR OR RENEW AIR REGULATOR ON FIREMAN OUTFIT._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Electrical
Issued 12 January 1998 Resolved
INSTALL DRIP SHIELD OVER/ON MAIN SWITCH BOARD._x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 2 January 1997 Resolved
Repair the following leaks; port main engine(J/W), deck winch suction line(HYD), port main engine power take off(HYD)._x001C_
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 2 January 1997 Resolved
Properly mark the start switch for the fire pump and general alarm contact maker in the engine room. _x001C_
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 2 January 1997 Resolved
Remove all hyd oil from around V-drives._x001C_
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 2 January 1997 Resolved
Relocate emergency remote stops for machinery to outside engine room._x001C_
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Engineering
Issued 2 January 1997 Resolved
Repair overspeed trip on port main engine._x001C_
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 10 August 1995 Resolved
Brow was not properly secured, and shifted when subject stepped on brow during vessel operations. Subject fell approximately 14 feet and sustaineda collapsed lung, broken ribs, and lacerated liver.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 January 2002
Fire Fighting
Issued 5 April 1991 Resolved
REINSTALL THE FIXED CO2 FIRE EXTINGUISHER FOR THE PAINT LOCKER.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Electrical
Issued 5 April 1991 Resolved
PROVE THE PROPER OPERATION OF THE SPEED CONTROL ADJUSTMENT KNOB ON NO. 2_x001C_ SERVICE GENERATOR.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
PROVE THE PROPER OPERATION OF THE LOW OIL PRESSURE ALARM ON THE STARBOARD_x001C_ MAIN DIESEL ENGINE.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Accommodation/Occupational Safety
Issued 6 February 1990 Resolved
INSTALL A SUITABLE HOSPITAL FACILITY TO MEET THE REQUIREMENTS OF 46 CFR 92.20-35. ROOM TO HAVE THREE (3) BEDS ONE HAVING ACCESS FROM BOTH SIDES.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Electrical
Issued 6 February 1990 Resolved
PROVIDE MANUFACTURES CERTIFICATION THAT ALL MOTOR CONTROLLERS (GE&AB) MEET THE REQUIREMENTS OF UL508 AS REQUIRED BY 46 CFR 111.70-3 & CFR 111.77-3. MAIL COPY TO MORGAN CITY.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Unknown
Issued 6 February 1990 Resolved
SUBMIT OUTSTANDING PLANS, ABS COMMENT LETTERS AND FINAL RESOLUTIONS TO OCMIMORGAN CITY, TO INCLUDE BUT NOT TO LIMITED TO: ITEMS ADDRESSED IN FINAL MACHY COMMENT LTR DTD 02FEB90. PLANS P4/P6/E1/E2 AND E3 PROVIDE A COPY OF INTERIM ABS CLASSIFICATION CERTIFICATE WHEN ISSUED TO [name withheld].
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Navigation
Issued 17 March 1989 Resolved
SWING COMPASS AND OBTAIN A COMPASS DEVIATION CARD.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Documentation
Issued 17 March 1989 Resolved
PROVIDE ON BOARD AND MAINTAIN CARGO RECORD BOOK.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Documentation
Issued 17 March 1989 Resolved
PROVIDE ON BOARD VESSEL CURRENTLY VALID CERTIFICATE OF DOCUMENTATION (COD).46 CFR 67.23-3(13)(B).
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Documentation
Issued 17 March 1989 Resolved
PROVIDE ON BOARD ADDITIONAL COPY OF LAWS COVERING INSPECTION.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Electrical
Issued 17 March 1989 Resolved
RENEW AND PROPERLY SECURE BATTERY BOX FOR STARBOARD GENERATOR 46 CFR 111.15-5(B).
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989 Resolved
POST AT LIFE RAFT STATIONS PICTURE-TYPE LAUNCHING INSTRUCTIONS FOR BRAND OFINFLATABLES CARRIED ABOARD VESSEL. 46 CFR 97.39-1(A), 46 CFR 160.051-6(C) (1).
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Documentation
Issued 17 March 1989 Resolved
PROVIDE ON BOARD VESSEL COPY OF LOADLINE REGULATIONS 46 CFR 42-46.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 8 August 1985 Resolved
REPAIR SHORT IN FORWARD ANCHOR LIGHT.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985