MAURY USCG vessel records
← All vessels

PELAGOS

PELAGOS is a 1999 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in July 2019, along with 4 deficiencies and 3 operational controls.

Records from 2016 to 2019. Most recent: inspection, 20 July 2019.

Built
1999
Last inspected
20 July 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 July 2019
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9176761
500124
Flag
GREECE
Maury page id
psix-500124

Documentation record

Tonnage as PSIX records it39283 - Convention (Subpart B), Gross Ton
22536 - Convention (Subpart B), Net Ton
76020 - Dead Weight, Metric Ton
88642 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

20 July 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6745553
18 July 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6754641
10 March 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6639509
6 March 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6637547
5 March 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6636566
17 November 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6582693
1 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6528901
26 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6523372
5 June 2018 COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6425312
3 June 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6432633
2 June 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6432433
29 December 2017 PII Safety Exam · COE-Dockside · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6328614
18 December 2017 COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6326005
14 November 2017 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6306762
29 June 2017 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6173890
28 May 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6157679
27 May 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6151015
26 May 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6156507
24 February 2017 COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6093863
1 December 2016 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6050756
2 July 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5926635
26 June 2016 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5913271

Deficiency record · 4

Engineering › Steam Boiler (auxiliary/waste heat) › Feed pipe
Issued 5 June 2018 Resolved
1499-other machinery propulsion- Boilers shall be provided with means to supervise and control the quality of the feedwater. Suitable arrangements shall be provided to preclude the entry of oil or other contaminants which may adversely affect the boiler. PSCO observed an oil sheen in the condensate tank. 74SOLAS (2001 Cons) II-1/32.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2018
Resolved 26 August 2018
Lifesaving › Inflatable Liferafts › Servicing
Issued 26 June 2016 Resolved
0620-Inflatable liferafts-Every inflatable liferaft, shall be serviced at intervals not exceeding 12 months, provided where in any case this is impracticable, the Admin may extend this period to 17 months; PSCO observed liferafts out of servicing date, Master had letter from class extending until 07 Sep 2016 as authorized by flag but should be serviced at port of convenience.SOLAS(14) III/20.8.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2016
Resolved 29 June 2016
Resolution: Recieved pictures of lift rafts installed. Vessle made clear to depart.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 26 June 2016 Resolved
0820-Protection machinews/parts-The machinery, associated piping systems and fitting shall be of design and construction adequate for service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed a sever exhaust leek coming from #7 diesel motor turbo for cargo pump hydrolic pack SOLAS 74a (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 2 July 2016
Resolution: Cleaned sealing surfaces and performed operational test. See class report in documents.
Engineering › Feedwater/Condensate Water System › Observation Tank
Issued 26 June 2016 Resolved
1499-Other-Boilers shall be provided with means to supervise and control the quality of the feedwater. PSCO observed a black substance inside the boiler feedwater tank. SOLAS 74a (04) II-1/32.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 2 July 2016
Resolution: Drained feedwater tank, refilled, and adjusted chemical treatment system. Observed satisfactory test results of feedwater treatment.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.