MAURY USCG vessel records Sign in
← All vessels

MR JACK

MR JACK is a 1978 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1981, most recently in February 2009, along with 50 deficiencies and 2 casualty investigations between 2001 and 2004.

Records from 1981 to 2009. Most recent: inspection, 3 February 2009.

Built
1978
Last inspected
3 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA9730
Flag
UNITED STATES
369194000 (licence lapsed)
Maury page id
psix-50020

Inspections, by type

…with no type recorded17
Years with a record 22 calendar years (1981–2009)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA9730MMSI 369194000 · cancelled · compulsorily equipped · granted 10 September 2002, cancelled 22 June 2010
WCX9315MMSI not assigned · expired · compulsorily equipped · granted 23 January 1998, cancelled 29 March 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS QUYNH ANH II Commercial Fishing Vessel · MISLE 500369 · 26 November 2001 · activity 1490485

Inspection history · 47

3 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3427078
13 February 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3146769
15 March 2007 Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2887940
1 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2765926
3 January 2006 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2559528
6 September 2005 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2475680
14 June 2005 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390770
7 June 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2382313
25 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2342548
5 January 2005 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2284770
24 August 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2225285
9 August 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2176143
25 November 2003 Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1954317
22 September 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1923166
21 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1733075
26 November 2001 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1484255
26 November 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1490485
15 November 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397752
23 February 2001 Damage Survey · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1447040
7 February 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 175774
11 January 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443127
14 January 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401152
1 December 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812462
3 September 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782511
3 June 1999 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804112
4 January 1999 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815083
28 December 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 14651
23 December 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423112
7 January 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364560
12 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 202084
12 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753883
8 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239035
16 May 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1242352
16 May 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201023
30 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028830
7 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331119
30 May 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298737
13 August 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296784
3 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982474
23 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280329
2 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973217
20 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276330
11 February 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969725
11 February 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973018
12 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970496
11 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964192
8 January 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969750

Deficiency record · 50

Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 February 2008 Resolved
Provide current editions of tide tables, tide current tables, and CG Light List onboard vsl.
Action required: 705 - Other - as specified
Resolved 27 February 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2008 Resolved
Provide eye wash bottles for eye wash station on main deck.
Action required: 705 - Other - as specified
Resolved 27 February 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 February 2008 Resolved
Install a safety guard on exposed shaft/flywheel on port generator.
Action required: 705 - Other - as specified
Resolved 27 February 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 February 2008 Resolved
Provide a means to positively secure the sewage overboard discharge valve while in prohibited discharge area.
Action required: 705 - Other - as specified
Resolved 27 February 2008
Lifesaving › Hand Flares › Not on Board
Issued 3 January 2006 Resolved
There were only 6 of the required 12 distress signals onboard.
Action required: 705 - Other - as specified
Resolved 3 January 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 January 2006 Resolved
renew life lines on all life rings, line was worn and damaged.
Action required: 705 - Other - as specified
Resolved 3 January 2006
Construction/Loadline › Hull › Hull Plating
Issued 3 January 2006 Resolved
Bulwark on port bow is heavily corroded. Holes lead to void behind chock that is inaccessible, crop out and renew plating. Inspect void for watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2006
Resolved 3 January 2006
Engineering › Generator (propulsion-electric) › Overcurrent Devices Circuitry
Issued 3 January 2006 Resolved
Engineer was unable to show proper operation of the Port Generator Overspeed trip.
Action required: 705 - Other - as specified
Resolved 3 January 2006
Stability › Incline Test › General
Issued 3 January 2006 Resolved
The master was untrained on the use of the stability booklet. The COI specifically requires this training. Cal-Dive is responsible for holding the training.
Action required: 705 - Other - as specified
Due 3 February 2006
Resolved 1 September 2006
Resolution: received Stability Letter
Communications › Radio Communications › VHF Radiotelephone
Issued 3 January 2006 Resolved
The station license did not have the correct Call sign for the vessel. The master said he had no idea where the call sign came from, theirs had never changed.
Action required: 705 - Other - as specified
Due 3 February 2006
Resolved 1 September 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 7 June 2005 Resolved
Provide permenant draft marks, load marks per 46 CFR 185.602(c).
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 14 June 2005
Resolution: Observed sat draft and load marks on vsl.
Operations/Management › Drug and Alcohol Testing
Issued 9 December 2003 Resolved
Placard missing. LEGACY COMPONENT DESC: EAP Display Requirements
Condition: Unknown
Due 9 December 2003
Resolved 9 December 2003
Resolution: Obtained placard.
Documentation › Manuals/Policy Documentation
Issued 25 November 2003 Resolved
Emergency broadcast placard missing. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Due 9 December 2003
Resolved 9 December 2003
Resolution: Obtained placard.
Stability › Watertight Integrity
Issued 25 November 2003 Resolved
switch for watertight door indicator was broken. LEGACY COMPONENT DESC: watertight door indicators
Condition: Improper/Lack of Maintenance
Due 9 December 2003
Resolved 9 December 2003
Resolution: Repaired switch.
Electrical › Electrical Distribution System (service)
Issued 25 November 2003 Resolved
Condition: Unknown
Due 9 December 2003
Resolved 9 December 2003
Resolution: Provided mat.
Electrical › Electrical Distribution System (service)
Issued 25 November 2003 Resolved
Dust covered receptacle causing fire hazard. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 9 December 2003
Resolved 9 December 2003
Resolution: Cleaned receptacle.
Fire Fighting › Fire Main
Issued 25 November 2003 Resolved
soft patch at fair main manifold. LEGACY COMPONENT DESC: Condition
Condition: Damaged By Earlier Event
Due 9 December 2003
Resolved 9 December 2003
Resolution: Replaced section of fire main.
Engineering › Compressed Air System (start air)
Issued 25 November 2003 Resolved
relief valves not tested. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 9 December 2003
Resolved 9 December 2003
Resolution: Replaced valves.
Stability › Unintentional Flooding
Issued 25 November 2003 Resolved
Condition: Unknown
Due 9 December 2003
Resolved 9 December 2003
Resolution: Provided handle for tightening dogs on WTD.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 25 November 2003 Resolved
bunk light mount broken, light hanging by electrical wires. LEGACY COMPONENT DESC: Berth
Condition: Improper/Lack of Maintenance
Due 9 December 2003
Resolved 9 December 2003
Resolution: Replaced bunk light.
Lifesaving › Buoyant Apparatus
Issued 21 January 2003 Resolved
Stencil paddles for life floats with name of vessel. LEGACY COMPONENT DESC: Paddles
Due 21 February 2003
Resolved 21 January 2003
Accommodation/Occupational Safety › Potable Water System
Issued 21 January 2003 Resolved
Provide insect screen for potable water tank vent. LEGACY COMPONENT DESC: Insect Screen
Due 21 February 2003
Resolved 22 January 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 21 January 2003 Resolved
Provide light cover and vent screen on galley range. LEGACY COMPONENT DESC: Range Hood
Due 21 February 2003
Resolved 22 January 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 January 2003 Resolved
Provide eye wash bottles for all eye wash stations.
Due 21 February 2003
Resolved 23 January 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 January 2003 Resolved
Provide eye wash bottles for all eye wash stations.
Due 21 February 2003
Resolved 23 January 2003
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 21 January 2003 Resolved
Remove all flamable paint from machinery space and store in paint locker.
Due 21 February 2003
Resolved 21 January 2003
Stability › Watertight Integrity
Issued 21 January 2003 Resolved
Adjust all watertight doors. LEGACY COMPONENT DESC: Watertight Door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Engineering › Fuel Oil Service System › Filter
Issued 21 January 2003 Resolved
Replace plastic pet cock valves on all fuel filters.
Due 21 February 2003
Resolved 21 January 2003
Engineering › Fuel Oil Service System › Filter
Issued 21 January 2003 Resolved
Provide flame bowls for all fuel filters.
Due 21 February 2003
Resolved 23 January 2003
Lifesaving › Rescue Boat › Markings
Issued 21 January 2003 Resolved
Provide retro for rescue boat and stencil boat with name, length and beam.
Due 21 February 2003
Resolved 23 January 2003
Lifesaving › Rescue Boat Equipment
Issued 21 January 2003 Resolved
Provide all rescue boat equipment. LEGACY COMPONENT DESC: None
Due 21 February 2003
Resolved 27 January 2003
Engineering › Bilge Water Management System › Valve
Issued 21 January 2003 Resolved
Repair forepeak reach rod.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Communications › Alarms/Indicators › General Alarm
Issued 21 January 2003 Resolved
Provide general alarm placards for general alarm switch and general alarm speaker in engine room.
Due 21 February 2003
Resolved 23 January 2003
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 21 January 2003 Resolved
Provide emergency broadcast placard.
Due 21 February 2003
Resolved 21 January 2003
Operations/Management › Pollution › Control of Garbage
Issued 21 January 2003 Resolved
Provide a waste management plan.
Due 21 February 2003
Resolved 22 January 2003
Operations/Management › Passenger Operations › Safety Orientation
Issued 21 January 2003 Resolved
Provide passenger safety orientation.
Due 21 February 2003
Resolved 22 January 2003
Communications › Audible Communications › Bell
Issued 21 January 2003 Resolved
Provide ships bell.
Due 21 February 2003
Resolved 22 January 2003
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 21 January 2003 Resolved
Paint draft marks.
Due 21 February 2003
Resolved 22 January 2003
Unknown
Issued 23 February 2001 Resolved
Prior to shipyard to affect repairs, notify [name withheld].
Condition: Unknown
Due 24 February 2001
Resolved 24 February 2001
Engineering
Issued 23 February 2001 Resolved
Prove proper operation of the starboard main engine._x001C_
Condition: Unknown
Due 24 February 2001
Resolved 24 February 2001
Electrical
Issued 23 February 2001 Resolved
Complete repairs to all engineroom wiring/lighting.
Condition: Unknown
Due 24 February 2001
Resolved 24 February 2001
Documentation
Issued 1 December 1999 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR ADDITION OF DECK CRANE AND WINCH SYSTEM.
Condition: Unknown
Due 1 February 2002
Resolved 9 December 2003
Resolution: Received copy of approved plan for crane installation, winch, stability book, and letter.
Documentation
Issued 3 September 1999 Resolved
PROVIDE COAST GUARD MSC APPROVED PLANS FOR ADDITION OF DECK CRANE AND WINCHSYSTEM.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 3 June 1999 Resolved
PROVIDE COAST GUARD MSC APPROVED PLANS FOR ADDITION OF DECK CRANE AND WINCHSYSTEM.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Deck/Cargo
Issued 3 May 1985 Resolved
REPAIR BOTH FUEL VENTS (PORTSIDE). COMPLETE ABOVE ITEMS WITHIN THIRTY (30)DAYS TO THE SATISFACTION OF COGNIZANT OFFICER-IN-CHARGE, MARINE INSPECTION.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Accommodation/Occupational Safety
Issued 3 May 1985 Resolved
MAKE OPERABLE REFRIGERATION COMPRESSOR.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Fire Fighting
Issued 3 May 1985 Resolved
MAKE OPERABLE FIRE MONITOR.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Unknown
Issued 3 May 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V PRIVATE, O.N. 600549.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Documentation
Issued 12 February 1982 Resolved
PROVIDE TO [name withheld] COPIES OF VESSELS LOGS FOR THE PERIOD 1 JULY 1981 - 10 FEB 1981.
Condition: Unknown
Due 12 February 1982
Resolved 12 February 1982
Documentation
Issued 12 February 1982 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 February 1982
Resolved 12 February 1982

Casualty record · 2

26 November 2001Routine · role: Involved in a Marine Casualty · activity 1490485
24 August 2004Routine · role: Involved in a Marine Casualty · activity 2225285
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.