Records from 1999 to 2023. Most recent: inspection, 31 January 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
31 January 2023
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7627323
9 November 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7092065
7 November 2020
Ballast Water Examination · PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7091284
24 August 2008
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3307547
20 August 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3304469
16 August 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3299367
17 February 2008
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3148882
26 November 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3104755
12 June 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2959752
9 June 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2955990
8 June 2007
Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2955710
7 June 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2953855
14 May 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2649239
28 January 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2575258
3 June 2004
MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2087346
29 May 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2081823
5 February 2004
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2001046
7 August 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1869664
14 July 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1646731
16 April 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1605162
17 January 2002
Security Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1479976
15 July 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 280061
17 July 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 430809
Fire Fighting › Fire Main › Condition
Issued 16 August 2008
Resolved
During the testing of the emergency fire pump, a small hole was located on the discharge pipe, leaking water. The vessel is to make temporary repairs to the satisfaction of Class prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2008
Resolution: Class report received attesting to the temporary fixing of the emergency fire pump discharge line. A doubler was placed on the pump and no visible leak was observed during the testing of the pump.
Fire Fighting › Fire Main › Condition
Issued 16 August 2008
Resolved
During the testing of the emergency fire pump, a small hole on the discharge pipe was observed leaking water. The vessel is to make permanent repairs to the satisfaction of Class prior to next US port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2008
Resolution: Recieved Class report Stating temporary repair is sufficient, and Permanant repairs will be made prior to next Safety Equipment Survey (JUN09)
Lifesaving › Launching Appliances › Winch
Issued 9 June 2007
Resolved
Portside lifeboat release gear is inoperable. During operational test , failed to release from the stowed position.
Correct prior to departing to the satisfaction of the classification society. Solas 2004 Chp III Reg 20 .2 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2007
Resolution: Received class survey report all satisfactory.