Records from 1982 to 1993. Most recent: inspection, 12 August 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
12 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847133
28 October 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249876
13 December 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236549
30 November 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239509
30 October 1989
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928388
30 October 1989
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321168
18 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203197
8 March 1988
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335857
5 November 1987
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1024293
16 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018083
1 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330469
16 September 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005440
23 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986286
21 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285745
15 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963252
Fire Fighting
Issued 30 October 1989
Resolved
REPLACE BOTH SOLID STREAM "SUICIDE" NOZZLES WITH APPROVED COMBINATION NOZZLES AS REQUIRED BY 46CFR181.15-10 AND [name withheld].
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Documentation
Issued 30 October 1989
Resolved
PROVIDE ONBOARD AN APPROVED FIRE CONTROL PLAN AND POST IN CONSPICUOUS AREA.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Construction/Loadline
Issued 5 November 1987
Resolved
PROCEED TO NEW ORLEANS, LA VIA THE INTERCOASTAL WATERWAY TO COMPLETE CREDIT DRYDOCK AND HAVE A REINSPECTION COMPLETED. NO CARGO OR PERSONS OTHER THAN CREW TO BE CARRRIED.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Unknown
Issued 23 April 1986
Resolved
PROVIDE CIRCUIT DIRECTORY AND INSTALL BLANK COVER PLATES TO ELECTRICAL DISTRIBUTION PANEL IN WHEELHOUSE.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Navigation
Issued 23 April 1986
Resolved
REPAIR OR REPLACE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR FATHOMETER.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
INSTALL COMPASS LIGHT.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE CLOSURE DEVICES FOR ENGINE ROOM VENTS ON 01 DECK.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
INSTALL BALL TO BALLAST TANK VENT ON STBD SIDE MAIN DECK.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR WIRING TO FRESH WATER PUMP MOTOR.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
INSTALL GUARD FOR SANITARY PUMP.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE GUARDS FOR STBD S/S GENERATOR, BOTH MAIN ENGINES AND BOTH AIR COMPRESSORS.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE BATTERY BOX FORSTBD GENERATOR STARTING BATTERY.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR OR REPLACE INDICATOR LAMPS ON GENERATOR SWITCH BOARD.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR OR REPLACE AUTOMATIC MANUAL CONTROL SWITCH FOR #2 GENERATOR ON GENERATOR SWITCHBOARD.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE GENERATOR SWITCH BOARD CIRCUIT LOCKOUT DEVICE.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE ELECTIRC MAT IN FRONT OF GENERATOR SWITCHBOARD.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR EMERGENCY LIGHTING IN WHEELHOUSE.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
CHAIN ALL NOZZLE TIPS TO EVERY ALL PURPOSE NOZZLE.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
INSTALL GASKETS ON HATCH COVERS TO STEERING GEAR ROOM.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
CLEAN KNIFE EDGES ON ALL WATERTIGHT DOORS AND HATCHES.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
INSTALL PRESSURE GUAGE ON DISCHARGE SIDE OF MAIN FIRE PUMP.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
MAKE FORWARD BULKHEAD IN ENGINE ROOM WATERTIGHT.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
RELABEL ALARMS ON ALARM PANEL IN ENGINEROOM.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
TIGHTEN LAGGING ON STBD MAIN ENGINE EXHAUST.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
LABEL ALL MOTOR CONTROLLERS.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
CLEAN UP LABELS ON BALLAST MANIFOLD AND BILGE MANIFOLD.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPLACE MISSING LAGGING ON STBD GENERATOR.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
TIGHTEN DOWN VENT ON STEERING GEAR HYDRAULIC SOMP.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR OR REPLACE RANGE VENT.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE DIRECTORY OF CIRCUITS AND INSTALL BLAND COVERS FOR ELECTRICAL DISTRIBUTION PANEL IN ENGINE ROOM.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
STENCIL ALL VENTS ON OPEN DECKS.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
REPAIR FUEL OIL REMOTE SHUTOFF REACH ROD STBD SIDE IN ENGINE ROOM.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE FUEL OIL TRANSFER PROCEDURED.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE POLLUTION PREVENTION PLACARD FOR ENGINE ROOM.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PROVIDE EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1986
Resolved
PAINT LOADLINE AND DRAFT MARKS.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986