FREEPORT GEM is a 1978 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in July 2025, along with 108 deficiencies and 3 casualty investigations between 2020 and 2022.

Records from 1985 to 2025. Most recent: inspection, 28 July 2025.

Built
1978
Last inspected
28 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5661
Flag
UNITED STATES
367560650
Maury page id
psix-50046

Inspections, by type

…with no type recorded7
Years with a record 36 calendar years (1985–2025)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 22.0 ft × 6.2 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · STUART, FL, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFREEPORT, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 7 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5661MMSI 367560650 · active · compulsorily equipped · granted 2 May 2024, expires 2 May 2034
WDG6787MMSI 367560650 · expired · compulsorily equipped · granted 26 January 2013, cancelled 1 April 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDD2394MMSI 367114750 · expired · compulsorily equipped · granted 16 May 2006, cancelled 16 July 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDB4333MMSI 366897310 · expired · compulsorily equipped · granted 12 June 2003, cancelled 17 August 2013 · licensed under a name not among this hull’s recorded names (not shown)
WRA6935MMSI not assigned · expired · compulsorily equipped · granted 13 January 1997, cancelled 1 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

28 July 2025 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8196350
6 March 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8089145
24 April 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7901418
8 April 2024 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7891856
1 August 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7753913
27 April 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7659621
30 March 2023 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7659965
20 August 2022 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7546174
8 August 2022 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7477952
5 August 2021 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7277743
25 April 2021 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7312124
8 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7150953
9 August 2020 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7075688
21 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7011039
7 May 2019 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6661330
25 April 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6670274
4 October 2018 Administrative Inspection · Deficiency Check · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6552417
2 April 2018 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6383087
12 April 2017 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6119296
14 November 2016 Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6040826
4 April 2016 COI Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5847970
7 June 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4335482
1 February 2011 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3936235
22 January 2009 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3398136
20 March 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3174469
23 January 2008 Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3132906
19 March 2007 In-Service Inspection · Simplified Stability Test · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2891088
11 January 2006 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2562328
18 January 2005 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2276315
2 September 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1894597
15 July 2003 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1939760
20 June 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1822212
15 May 2003 COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1791513
11 December 2002 Internal Structural Exam · Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1766249
18 June 2002 Deficiency Check · Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1632710
28 February 2002 Hull Examination · Internal Structural Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1490239
31 July 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1472834
23 June 2001 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 46014
20 April 2001 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1063201
19 April 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1448255
2 October 2000 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1053706
1 September 2000 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1053612
22 June 2000 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1050753
6 April 2000 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1457757
13 April 1999 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1424727
24 March 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1113473
23 April 1998 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1125975
26 March 1998 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 787381
16 April 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1095698
19 April 1996 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1085770
12 April 1996 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1079088
26 April 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1176184
31 March 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 835800
2 November 1994 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 862012
3 August 1994 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1175461
25 April 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1170477
12 April 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 857926
29 March 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 856186
10 May 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1139482
22 April 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 838075
16 March 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1148284
23 October 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1251678
17 September 1992 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1244017
27 March 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 951518
29 March 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 908363
20 March 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1217283
17 September 1990 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 931753
11 May 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 919138
2 April 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 932999
31 March 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1350885
10 March 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1204490
28 March 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 991032
29 February 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1337676
31 March 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1327826
13 March 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1014872
28 March 1986 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1306076
28 February 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1297246
27 March 1985 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980122
27 March 1985 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1288218

Deficiency record · 108

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 24 April 2024 Resolved
FCC radio sta auth was not current. Vessel restricted to 1000 feet until proof of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 May 2024
Resolution: Provided new cert.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 April 2024 Resolved
Vessel only had 07 flares required 12. Corrected while on board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2024
Resolved 24 April 2024
Resolution: Fixed on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2023 Resolved
Provide current FCC Safty radio certificate.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 9 August 2023
Resolution: Copy of certificate provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2023 Resolved
Replace STBD side fire hose.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2023
Resolved 8 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 August 2023 Resolved
Prove proper operation of masthead light prior to operating at night.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 9 August 2023
Resolution: Repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2022 Resolved
Vessel is required to have a spanner wrench at the fire hose connection point.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 1 September 2022
Resolution: Visual proof of spanner wrench.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 October 2018 Resolved
Seal #2 and #3 frames in forepeak and remove any rotted wood. Prior to credit drydock.
Action required: 705 - Other - as specified
Due 4 November 2018
Resolved 9 October 2018
Resolution: Rotted wood removed and frames resealed with epoxy.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 4 October 2018 Resolved
Seal ventilation openings in watertight bulkheads between #2 and #3 vods and in between #3 void and engine room to the satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2018
Resolved 23 October 2018
Resolution: Vent openings sealed using marine grade plywood and 5200.
Fire Fighting › Fire Pumps › Pressure
Issued 2 April 2018 Resolved
Port side engine-driven pump leaks excessively when operating. Prove proper operation of pump.
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 23 April 2018
Resolution: Operator replaced pump seal and it now has adequate pressure.
Lifesaving › Lifefloat › Serviceable
Issued 2 April 2018 Resolved
Properly connect weak link to life float and vessel. Replace 2 broked wood paddles. Secure all paddles to their respective life floats.
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 23 April 2018
Resolution: Lifefloat weak link now properly installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2018 Resolved
Fix ground for 110v electrical panel and change panel cover. Replace connections in jucntion box. Remove dead-end wire and unused recepticle.
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 23 April 2018
Resolution: Ground on 110v system reinstalled. All outlets on panel show ground on tester.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 April 2018 Resolved
PWG 04: Place fuel shut off valves at independent fuel tanks. Make valves operable outside the tank space. 46 CFR "Old T" 182.20-40(b)(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 16 May 2018
Resolution: Two valves installed with pull wires located on main deck.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2017 Resolved
Provide burn gel/spray in first aid kit.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 20 April 2017
Resolution: Burn gel/spray provided.
Lifesaving › Hand Flares › Quantity
Issued 12 April 2017 Resolved
Vessel is required six hand red and six orange smoke flares. Provide 2 additional red and 3 orange flares.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 20 April 2017
Resolution: Additional flares provided
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 12 April 2017 Resolved
Provide vessel's waste management plan.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 20 April 2017
Resolution: Waste management plan drafted and posted.
Lifesaving › Lifefloat › Serviceable
Issued 12 April 2017 Resolved
Make repairs to lifefloats to return to serviceable condition.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 20 April 2017
Resolution: Proper repairs made to the lifefloats with [name withheld] repair kit.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 12 April 2017 Resolved
Repair leaks of oil and exhaust on main engine turbochargers.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 20 April 2017
Resolution: Source of leak was broken/losose clamps on exhaust. The clamps were replaced or tightened as necessary.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 April 2017 Resolved
Remove romex cable and replace with boat cable or marine grade cable.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 20 April 2017
Resolution: Romex was removed and replaced with boat cable.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 April 2016 Resolved
MOB emergency procedures do not reflect MOB operations.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Proper man overboard procedures were posted.
Construction/Loadline › Structures › Superstructure
Issued 23 May 2007 Resolved
Owner required to submit plans to prove the adequacy of the support structures for the additional weight of passengers on the upper deck.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 21 July 2007
Resolution: Received plans from Nav Arch.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2007 Resolved
Provide valid FCC Safety Radiotelephone certificate.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 21 May 2007
Resolution: Verified valid Safety Radiotelephone certificate.
Electrical › Electric Generation Source (service) › Generator
Issued 17 May 2007 Resolved
Prove proper operation of ship service generator prior to operation of the generator.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Resolution: Witnessed proper operation of generator.
Engineering › Fuel Oil Service System › Piping
Issued 16 May 2007 Resolved
Properly secure unused fuel line in lazarette and clean all fuel in bilge of lazarette compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Fuel oil piping removed and plug installed at valve. All fuel in lazarette removed and space cleaned.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 16 May 2007 Resolved
Install double hose clamps for raw water cooling on both port and stbd MDEs.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 17 May 2007
Resolution: All identified hoses were double clamped.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007 Resolved
Install metal hangers for all wiring and fuel hoses in engine room at least every 24 inches.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 17 May 2007
Resolution: Metal hangers properly installed in E/R.
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 16 May 2007 Resolved
Clean hydraulic oil spill on stbd side in engine room bilge.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 17 May 2007
Resolution: Hydraulic oil properly cleaned in E/R bilge.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 May 2007 Resolved
Complete servicing for portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Fire extinguishers have been serviced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 19 March 2007 Resolved
Vessel restricted from carrying passengers until re-measured for number of passengers permitted when modification to cabin is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2007
Resolution: Measured cabin after modification and issued CG-858 for new number of passengers permitted.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 January 2007 Resolved
Vessel restricted from carrying passengers until repairs completed to watertight bulkhead. Repair proposal and final work to be verified by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Resolution: Repairs to watertight bulkhead complete. Inspected with satisfactory results.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2006 Resolved
Install additional rail course to make spaces 12" or less.
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 11 August 2006
Communications › Visual Communication › Signalling Lamp
Issued 12 May 2006 Resolved
Install sensor on bridge to notify when QAWTD is open or closed
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 11 August 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 May 2006 Resolved
Install lights on OCEANS ROUTE life jackets. Vessel restricted LCW route untill installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 January 2006 Resolved
Vessel required to make bulkhead permanently watertight in way of QAWTD. Submit plans prior to commencing work.
Action required: 705 - Other - as specified
Due 12 February 2007
Resolved 25 February 2007
Resolution: Received plans and approved them locally. Notified owner/operator via telephone to commence repair.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 11 January 2006 Resolved
Replace gasket in fwd scuttle.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Engineering › Bilge Water Management System › Strainer
Issued 11 January 2006 Resolved
Install strainer on bilge line in #2 compt.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 11 January 2006 Resolved
Install metal hangers every 24" on wire runs in E/R.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 January 2006 Resolved
Install longer pendants between L/F's.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Navigation › Piloting/Steering › Marine Charts
Issued 11 January 2006 Resolved
Provide current charts for area on COI
Action required: 705 - Other - as specified
Resolved 12 May 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 January 2006 Resolved
Make opening in fwd E/R bulkhd, port side air tight.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 January 2006 Resolved
Install hose clamps on out board exhaust pipe.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Engineering › Steering Gear System › Linkage
Issued 11 January 2006 Resolved
Renew tie rod end on steering linkage.
Action required: 705 - Other - as specified
Resolved 12 May 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 11 January 2006 Resolved
Prove proper operation of MF radio prior to operating on an Oceans route.
Action required: 705 - Other - as specified
Resolved 11 August 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 January 2005 Resolved
Vessel required a Coast Guard dry-dock and Reinspection prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2006
Communications › Radio Communications › EPIRB
Issued 15 May 2003 Resolved
REPLACE EPRIB BATTERY. VESSEL IS RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL REPLACED. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 12 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 May 2003 Resolved
INSTALL WORKING OR CURRENT DATED LIGHTS ON ALL LIFEJACKETS. VESSEL IS RESTRICTED TO NOT MORE THAN 20 MILES FROM SHORE UNTIL ALL LIGHTS ARE INSTALLED. LEGACY COMPONENT DESC: Lights
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 11 August 2006
Documentation › Certificates/Documents
Issued 15 May 2003 Resolved
PROVIDE PROOF OF CURRENT CERTIFICATE OF DOCUMENTATION. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 20 June 2003
Resolution: COD ONBOARD.
Documentation › Certificates/Documents
Issued 15 May 2003 Resolved
PROVIDE PROOF OF CURRENT RADIO STATION LICENSE. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 20 June 2003
Resolution: STATION LICENSE ONBOARD.
Documentation › Certificates/Documents
Issued 15 May 2003 Resolved
PROVIDE PROOF OF CURRENT SAFETY RADIO TELEPHONY CERTIFICATE. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 20 June 2003
Resolution: SRT CERTIFICATE ONBOARD.
Communications › Radio Communications
Issued 15 May 2003 Resolved
PROVIDE PROOF OF CURRENT EPIRB REGISTRATION WITH NOAA. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 22 August 2003
Resolution: OWNER REPORTED EPIRB REGISTERED WITH NOAA.
Navigation › Piloting/Steering
Issued 15 May 2003 Resolved
PROVIDE COAST PILOT AND CURRENT CHARTS FOR THE VESSEL'S OPERATING AREA. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 20 June 2003
Resolution: COAST PILOT AND CHARTS ONBOARD.
Construction/Loadline › Structures
Issued 15 May 2003 Resolved
FABRICATE VENTILATION CLOSURES FOR THE ENGINEROOM AND CLOSE OFF THE HEATING SYSTEM VENTS IN THE ENGINEROOM. LEGACY COMPONENT DESC: Ventilators
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 22 August 2003
Resolution: OWNER REPORTED VENT CLOSURES INSTALLED.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 May 2003 Resolved
PROVIDE PROOF OF CURRENT SERVICING OF THE FIXED FIRE FIGHTING SYSTEM AND HAVE THE SYSTEM TESTED IN THE PRESENCE OF A USCG MARINE INSPECTOR. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 22 August 2003
Resolution: OWNER PROVIDED PROOF OF FIXED SYSTEM TESTING.
Lifesaving › Embarkation Appliances/Stations
Issued 18 June 2002 Resolved
PROVIDE WEAK LINK TO IBA. LEGACY COMPONENT DESC: WEAK LINK
Due 24 June 2002
Resolved 9 July 2002
Navigation
Issued 31 July 2001 Resolved
Prove proper operation of the SSB radio prior to operating vessel on a route greater than 20 miles from a harbor of safe refuge.
Condition: Unknown
Due 8 August 2001
Resolved 13 August 2001
Lifesaving
Issued 19 April 2001 Resolved
REPLACE 14 LIGHTS ON PFD'S PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 19 April 2001 Resolved
REPLACE 6 CONDEMNED PFD'S PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 19 April 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 19 April 2001 Resolved
REPLACE OR SERVICE 2 PORTABLE FIRE EXTINGUISHERS IN THE ENGINE ROOM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Navigation
Issued 1 September 2000 Resolved
PROVE PROPER OPERATION OF SSB/HF RADIO
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Lifesaving
Issued 6 April 2000 Resolved
REPLACE ALL LIFE LINES ON LIFE FLOATS
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
REGISTER EPIRB
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Engineering
Issued 6 April 2000 Resolved
MAKE PERMANENT REPAIRS TO THE STBD MDE FUEL SYSTEM TO STOP THE LEAK ON TO THE MANIFOLD._x001C_ _x001C_
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVE PROPER OPERATION OF WATER LIGHTS (WEAK BATTERIES)
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Documentation
Issued 6 April 2000 Resolved
POST COI
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE LIGHTS FOR 8 PFDS, REPLACE AN ADDITIONAL 3 PFDS
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Documentation
Issued 6 April 2000 Resolved
POST STABILITY LETTER
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 6 April 2000 Resolved
VESSEL'S OPERATOR IS TO HAVE A VALID RADIO OPERATOR PERMIT
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 6 April 2000 Resolved
PROVIDE EXTRACT OF LIGHT LIST
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 6 April 2000 Resolved
PROVIDE COPY OF TIDE, CURRENT TABLES AND COAST PILOT.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 6 April 2000 Resolved
POST CURRENT DEVIATION TABLE
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
POST EMERGENCY INSTRUCTIONS
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 6 April 2000 Resolved
POST EMERG BCST INST
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Unknown
Issued 6 April 2000 Resolved
PROVIDE WASTE MANAGEMENT LOG (TRASH DISPOSIBLE)
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 13 April 1999 Resolved
Replace life line on life floats-(sun rot).
Condition: Unknown
Due 13 April 1999
Resolved 14 April 1999
Engineering
Issued 26 March 1998 Resolved
Renew as original port, aft, cutlass bearing.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Lifesaving
Issued 16 April 1997 Resolved
RENEW EPIRB BATTERY
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 16 April 1997 Resolved
RENEW WATERLIGHT BATTERY
Condition: Unknown
Due 23 April 1997
Resolved 27 June 1997
Lifesaving
Issued 16 April 1997 Resolved
RENEW/REPAIR 4 PFD LIGHTS
Condition: Unknown
Due 23 April 1997
Resolved 27 June 1997
Lifesaving
Issued 16 April 1997 Resolved
RENEW EPIRB HYDROSTATIC RELEASE
Condition: Unknown
Due 23 April 1997
Resolved 27 June 1997
Electrical
Issued 19 April 1996 Resolved
Replace raw water seal for generator feed water.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 19 April 1996 Resolved
provide restraining device for hatch on fantail.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Electrical
Issued 19 April 1996 Resolved
Replace broken globe for deck light on port side aft.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Fire Fighting
Issued 19 April 1996 Resolved
B-I extinguisher located in the forward compartment was undercharged.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Engineering
Issued 19 April 1996 Resolved
fuel filter housing for generator cracked and leaking fuel. Housing replaced.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 19 April 1996 Resolved
Paddle for life float was worn & split at the edges.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Engineering
Issued 26 April 1995 Resolved
PLUG FUEL FILTER DRAINS
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Fire Fighting
Issued 26 April 1995 Resolved
INSTALL MARINE BRACKET FOR PILOT HOUSE FIRE EXTINGUISHER
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 26 April 1995 Resolved
RENEW EPIRB HYDROSTATIC RELEASE_x001C_ _x001C_ VESSEL RESTRICTED TO COASTWISE ROUTE NMT 20 MILE UNTIL CORRECTED._x001C_ _x001C_
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Lifesaving
Issued 29 March 1994 Resolved
RENEW GRAB LINE ON STARBOARD RING BUOY PRIOR TO CARRAGE OF PASSENGERS
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Fire Fighting
Issued 29 March 1994 Resolved
PROVIDE NEW B-1 EXTINGUISHER IN FORWARD COMPARTMENT PRIOR TO CARRAGE OF PASSENGERS.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Construction/Loadline
Issued 29 March 1994 Resolved
INSTALL KEEPER CHAINS ON FLUSH DECK WTH'S
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Construction/Loadline
Issued 29 March 1994 Resolved
INSTALL VALVE HANDLE ON SEA SUCTION VALVE TO FLUSH PUMP.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
PROVIDE GLOBES AND GUARDS ON ALL DECK LIGHTS
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
REMOVE FLOURESCENT LIGHTS FROM FANTAIL.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994 Resolved
PROVIDE FLAME FAILURE ALARM FOR FURNACE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994 Resolved
PROVIDE ELECTRICAL SOLENIOD VALVE IN FUEL LINE TO BURNER
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994 Resolved
PROVIDE PREPURGE CYCLE FOR HOT AIR FURNACE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Lifesaving
Issued 29 March 1994 Resolved
REPLACE SIENE LINES ON UPPER LIFE FLOAT. VESSEL RESTRICTED TO NOT MORE THAN20 NM FROM HARBOR OF SAFE REFUGE UNTIL CORRECTED.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Lifesaving
Issued 29 March 1994 Resolved
RENEW ALL PFD BATTERIES FOR LIGHTS PRIOR TO OPERATION OF MORE THAN 20 NM FROM HARBOR OF SAFE REFUGE
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Lifesaving
Issued 29 March 1994 Resolved
PROVIDE ADDITIONAL PADDLE FOR LIFE FLOAT.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Lifesaving
Issued 16 March 1993 Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS INSTALL RETROREFLECTIVE MATERIAL ON ALL RING BUOYS AND BUOYANT APPARATUS AS REQUIRED BY 46 CFR 160.027-2 AND 160.010-3(P).
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Unknown
Issued 16 March 1993 Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Unknown
Issued 16 March 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 27 March 1992 Resolved
ROMEX SOLID CORE WIRE RUN POWERS 110 SUPPLY FOR BATTERY CHARGER. REPLACE SOLID CORE WIRE WITH APPROVED STRANDED WIRE SUITABLE FOR MARINE USE._x001C_
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Electrical
Issued 2 April 1990 Resolved
FLOATING ELECTRIC WATER LIGHTS PROVIDED WITH SPRING TERMINAL TYPE BATTERIESPROVIDE SCREW POST TERMINALS FOR WATER LIGHTS AS REQUIRED BY 46CFR 161.010-4(N).
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Engineering
Issued 2 April 1990 Resolved
MAIN ENGINE EXHAUST LEAKING INTO LAZARETTE. EFFECT PERMANENT REPAIR TO LEAKING EXHAUST.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Engineering
Issued 2 April 1990 Resolved
DAHL FILTER SEPARATOR ASSEMBLY IS NOT PROVIDED WITH HEAT SHIELD. PROVIDE FUEL SYSTEM WITH A USCG ACCEPT/U.L. MARINE LISTED FILTER ASSEMBLY.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Lifesaving
Issued 2 April 1990 Resolved
LIFE FLOAT PENDANTS DETERIORATED. RENEW PENDANTS IN ACCORDANCE WITH 46CFR 160.010-3(G). THIS REQUIREMENT TO BE COMPLETED PRIOR TO CARRYING PASSENGER
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990

Casualty record · 3

9 August 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7075688
25 April 2021Routine · role: Involved in a Marine Casualty · 1 injured · activity 7312124
20 August 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7546174
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.