Records from 1986 to 2002. Most recent: inspection, 27 June 2002.
Inspection history · 19
27 June 2002
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1637696
14 June 2001
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1613316
21 June 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 279117
26 July 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431089
17 May 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 19051
8 May 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 428447
18 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 102095
10 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 409817
10 November 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1106782
16 December 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 642236
16 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 171512
16 October 1996
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1159198
15 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 190667
10 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396627
10 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396664
12 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 29768
5 September 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 382918
10 November 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 962037
5 June 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1296581
Fire Fighting
Issued 8 May 1999
Resolved
Provide spanners at all cargo deck fire hose stations.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Deck/Cargo
Issued 8 May 1999
Resolved
Demonstrate operation of ODME to satisfacton of Classification Society.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Deck/Cargo
Issued 8 May 1999
Resolved
Have Classification Society determine status of ballast system as segregated or dedicated clean ballast as applicable to MARPOL and 33CFR157 and amend IOPP if needed.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Deck/Cargo
Issued 8 May 1999
Resolved
Prior to port crane being used for hoisting operations in U S waters, effect permanent repairs to port crane and have Classification Society loadtest.
Condition: Unknown
Due 18 August 1999
Resolved 2 November 1999
Accommodation/Occupational Safety
Issued 8 May 1999
Resolved
Prior to returning to U S waters, effect permanent repairs to deck rail in way of port side crane, aft of cargo manifold, in accordance with Classification Society recommendations.
Condition: Unknown
Due 18 August 1999
Resolved 2 November 1999
Deck/Cargo
Issued 16 October 1996
Resolved
PROVIDE USCG WITH CLASS REPORT STATING CARGO VACUUM STRIPPING SYSTEM OUT-_x001C_ STANDING RECOMMENDATION OF CLASS HAS BEEN RESOLVED OR THAT SYSTEM IS STILL ISOLATED AND THAT CARGO OPERATIONS CAN OPERATE SAFELY WITH NO CHANCE OF POLLUTION AS A RESULT OF THIS ARRANGEMENT.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Documentation
Issued 10 October 1996
Resolved
VESSEL IS NOT TO CONDUCT CARGO OPERATIONS UNTIL ONE-TIME EXEMPTION LETTER CONCERNING VESSEL'S VESSEL RESPONSE PLAN HAS BEEN RECEIVED ON BOARD. UPON RECEIVING LETTER CONTACT USCG MSU GALVESTON.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Electrical
Issued 5 September 1995
Resolved
SEND FAX COPIES OF SURVEY/REPAIR REPORTS FROM CLASS SOCIETY TO MSU GALVESTON PROVING PROPER OPERATION OF EMERGENCY GENERATOR (SIMULATE BLACKOUT OF SHIP, IF POSSIBLE, FOR AUTOMATIC STARTUP OF GENERATOR). TO BE COMPLETED PRIOR TO VESSEL SAILING FROM U.S. WATERS TO GO FOREIGN.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Navigation
Issued 5 September 1995
Resolved
SEND FAX COPIES OF SURVEY/REPAIR REPORTS OF VESSEL'S FATHOMETER/DEPTH SOUNDER & RECORDER TO MSU GALVESTON. TO BE COMPLETED PRIOR TO VESSEL SAILING FROM U.S. WATERS TO GO FOREIGN.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996