MAURY USCG vessel records Sign in
← All vessels

HOMBRE

HOMBRE is a 1979 commercial fishing vessel. The Coast Guard has recorded 63 inspections since 1982, most recently in November 2025, along with 122 deficiencies and 1 casualty investigation in 2023.

Records from 1982 to 2025. Most recent: inspection, 4 November 2025.

Built
1979
Last inspected
4 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2167
Flag
UNITED STATES
368026740
Maury page id
psix-50074

Inspections, by type

…with no type recorded15
Years with a record 31 calendar years (1982–2025)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)50.3 ft × 17.3 ft × 7.3 ft
Registered tonnagegross 42 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILL'S BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1979
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY, FL
Trade endorsementsFishery
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9506MMSI 368026740 · active · voluntarily equipped · granted 13 March 2018, expires 13 March 2028
WDD2167MMSI 367111790 · expired · compulsorily equipped · granted 5 May 2006, cancelled 9 July 2016
WDC3897MMSI 367015940 · expired · compulsorily equipped · granted 4 February 2005, cancelled 11 April 2015
WDA3855MMSI 366803030 · expired · compulsorily equipped · granted 8 March 2001, cancelled 14 May 2011
WCW9849MMSI not assigned · expired · compulsorily equipped · granted 19 December 1996, cancelled 24 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

4 November 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8266875
5 May 2023 Type not recorded
No type recorded · USCGC PABLO VALENT (WPC 1148) · USCG Southeast District (CGD-SE) · Activity 7688653
12 January 2023 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7621255
16 December 2021 Type not recorded
No type recorded · USCGC JACOB POROO (WPC 1125) · USCG Heartland District (CGD-H) · Activity 7370264
19 January 2021 Type not recorded
No type recorded · USCGC BENJAMIN B. DAILEY (WPC 1123) · USCG Heartland District (CGD-H) · Activity 7137519
31 March 2018 Type not recorded
No type recorded · USCGC DAUNTLESS (WMEC 624) · Activity 6401374
3 April 2009 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3462528
16 June 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3234622
21 May 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2977693
4 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2901705
1 May 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2637752
9 March 2005 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2306839
3 February 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2289180
1 June 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2138129
10 May 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2138202
4 May 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2058678
2 May 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1791978
18 April 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1771342
25 February 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1741316
28 March 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1480878
17 April 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1062660
29 March 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1064662
29 March 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393637
10 April 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1048648
9 March 2000 COI Inspection · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1418707
5 April 1999 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432094
2 December 1998 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1033052
5 February 1998 Inclining Experiment · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447810
22 January 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127090
2 December 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1464072
28 March 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419738
27 September 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141151
6 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084099
8 April 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404149
6 April 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460859
17 April 1995 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1444970
10 January 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171765
21 September 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380062
21 April 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 858375
11 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 858370
10 December 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849759
12 April 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1144672
22 September 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 936959
21 August 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 950734
15 May 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962480
17 May 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1001234
18 April 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1309526
1 March 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307980
22 February 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1213823
7 February 1989 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1344593
14 December 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032750
22 February 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1333722
16 November 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334012
3 August 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1029719
19 March 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1020825
18 March 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 996870
11 February 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989852
9 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1289371
26 February 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287611
13 December 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278837
28 November 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971046
15 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966785
16 March 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968498

Deficiency record · 122

Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 April 2009 Resolved
De-activated COI at owners request. A DD/ISE, and renewal of COI exam shall be completed prior to carrying more than 6 passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2022
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 June 2008 Resolved
Provide current training log book for abandon ship, fire, and man overboard drills.
Due 16 July 2008
Resolved 23 June 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 June 2008 Resolved
Provide current light list, coast pilot, and tide tables.
Due 16 July 2008
Resolved 23 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 June 2008 Resolved
Replace/Repair forward running light.
Due 16 July 2008
Resolved 23 June 2008
Documentation › Markings/Placards › Capacity Marking
Issued 16 June 2008 Resolved
Provide "Crew Only" placard for pilot house.
Due 16 July 2008
Resolved 23 June 2008
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 16 June 2008 Resolved
Repair aft smoke detector.
Due 16 July 2008
Resolved 23 June 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2008 Resolved
Replace expired medicine in first aid kit.
Due 16 July 2008
Resolved 23 June 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 June 2008 Resolved
Repair MSD line for shore connection on top of tank.
Due 16 July 2008
Resolved 23 June 2008
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 16 June 2008 Resolved
Prove derating of generator.
Due 16 July 2008
Resolved 23 June 2008
Engineering › Steering Gear System › Rudder
Issued 16 June 2008 Resolved
Repack rudder shafts.
Due 16 July 2008
Resolved 23 June 2008
Communications › Public Address System › Loudspeaker
Issued 16 June 2008 Resolved
Prove proper operation of PA system.
Due 16 July 2008
Resolved 23 June 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 June 2008 Resolved
Prove operation of emergency lighting.
Due 16 July 2008
Resolved 23 June 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 May 2007 Resolved
Post COI. 46CFR176
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Documentation › Logs/Records › Logbook (official)
Issued 21 May 2007 Resolved
Conduct and log drills. 46CFR185
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2007
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 21 May 2007 Resolved
Obtain (Charts, Inland Nav. Rules, Coast PIlot) 46CFR184.420
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 21 May 2007 Resolved
Post Emergency Broadcast Placard. 46CFR184.506
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 21 May 2007 Resolved
Demonstrate operational use of single side band radio. 46CFR184.620
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Communications › Radio Communications › EPIRB
Issued 21 May 2007 Resolved
Obtain new hydrostatic release for recently expired one for EPIRB. 46CFR180.64
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 May 2007 Resolved
Make seawater valves handles safe for operation. Noted to be broken and have knife sharp edges. 46CFR182
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Lifesaving › Lifefloat › Serviceable
Issued 21 May 2007 Resolved
Repair small crack to FRP lifefloat. 46CFR180
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Engineering › Steering Gear System › Rudder Bearing
Issued 4 April 2007 Resolved
Found port and starboard rudder bushings worn beyond acceptable running clearances. Re-new bushings in kind (46 CFR 176.800)
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 11 April 2007
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 4 April 2007 Resolved
Found starboard propulsion shaft strut bearing worn beyond acceptable running clearance. Renew bearing in kind. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 11 April 2007
Resolution: Port and starboard bearing renewed.
Documentation › Certificates/Documents › FCC SSL
Issued 1 May 2006 Resolved
Provide FCC Safety Certificate as required by 47 CFR 80.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 18 May 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 1 May 2006 Resolved
Install smoke detection unit in forward passenger accommodation space as required by 46 CFR 176.810(a)(7).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 April 2005 Resolved
Make machinery space ventilation duct closures vapor tight. (46 CFR 177.405)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 29 April 2005
Documentation › Markings/Placards › Warning Signs
Issued 11 April 2005 Resolved
Mark emergency exit EMERGENCY EXIT - KEEP CLEAR main deck. (46 CFR 185.606)
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 11 April 2005 Resolved
Make machinery space ventilation closures and all penetrations in overheads and bulkheads vapor tight. (46 CFR 177.405)
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Lifesaving › Lifefloat › Serviceable
Issued 11 April 2005 Resolved
Provide serviceable 22 person life float approved under 46 CFR 160.027, marked and stowed IAW 46 CFR 180.200)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 29 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2005 Resolved
Trouble shoot and repair electrical distribution system in pilot house and demonstrate safe installation to attending inspector.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 April 2005 Resolved
Mark remote fuel shut off valves IAW 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Fire Fighting › Fire Bucket › Quantity
Issued 11 April 2005 Resolved
Provide two (2) fire buckets w/lanyard and marked FIRE BUCKET (46 CFR 181.610)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 29 April 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2005 Resolved
Install emergency lighting in all passenger accommodation space located below the main deck in accordance with 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 March 2005 Resolved
Provide updated navigation safety publications. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Navigation › Piloting/Steering › Marine Charts
Issued 9 March 2005 Resolved
Provide updated and corrected navigation chart for area of intended operations. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 March 2005 Resolved
Demonstrate proper operation of navigation lights. 33 CFR 84.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Communications › Audible Communications › Horn/Whistle
Issued 9 March 2005 Resolved
Provide suitable sound producing device (horn). 33 CFR 86.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Communications › Radio Communications › EPIRB
Issued 9 March 2005 Resolved
Provide proof of registration of EPIRB. 46 CFR 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 11 April 2005
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 9 March 2005 Resolved
Remove window tinting from pilothouse windows or provide proof of 70% light transmission. 46 CFR 177.1030.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Lifesaving › Lifebuoys › Serviceable
Issued 9 March 2005 Resolved
Install retro reflective material on ring lifebuoy. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2005 Resolved
Provide approved first aid kit or equivalent. 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 March 2005 Resolved
Demonstrate proper operation of smoke detector in main salon. 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 11 April 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 9 March 2005 Resolved
Install 1 B-II portable extinguisher at entrance to machinery space. 46 CFR 181.500.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Fire Fighting › Ventilation Systems › Fans
Issued 9 March 2005 Resolved
Demonstrate operation of fixed fire extinguisher system automatic shut down of port propulsion engine and installed power ventilation system in machinery space. 46 CFR 182.465.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 11 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 March 2005 Resolved
Install machinery guard on starboard propulsion engine belt drive. 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 March 2005 Resolved
Install suitable machinery guard on both propulsion shafts. 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 March 2005 Resolved
Install metallic guards on Racor fuel filters on port and starboard propulsion engines and generator. 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Engineering › Fuel Oil Service System › Filter
Issued 9 March 2005 Resolved
Repair fuel oil leak on starboard propulsion engine fuel filter and prove tight. 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 9 March 2005 Resolved
Fixed power ventilation in machinery space in poor mechanical condition and electrically unsound. Repair or remove from vessel (see #11). 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 April 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 March 2005 Resolved
Replace flex hose, port propulsion engine raw water cooling from sea valve to pump intake and provide suitable supports for same. 46 CFR 182.420.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Electrical › Electric Supply System (service) › Cable
Issued 9 March 2005 Resolved
Remove all dead ended electrical conductors and properly support all electrical cables in machinery space. 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 29 April 2005
Construction/Loadline › Structures › Deck Plating
Issued 3 February 2005 Resolved
Repair as original transverse deck beam located on aft portion of engine room opening.
Action required: 705 - Other - as specified
Resolved 11 February 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 February 2005 Resolved
Replace PVC and Plastic below the waterline thru-hull penetration servicing Live Well with approved materials.
Action required: 705 - Other - as specified
Resolved 11 February 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 4 May 2004 Resolved
Provide oil pollution placard IAW 33 CFR 155.450. LEGACY COMPONENT DESC: Oil Discharge Placard
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 18 May 2004
Resolution: Placard Provided.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 May 2004 Resolved
Provide means to lock on MSD ovbd discharge valve IAW 33 CFR 159.95. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 1 June 2004
Resolution: Lock installed
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 May 2004 Resolved
Demonstrate fwd bilge high level alarm in anchor locker. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 1 June 2004
Resolution: Alarm installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 May 2004 Resolved
Install bilge high level alarm in aft steering compartment IAW 46 CFR 182.530. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 1 June 2004
Resolution: Alarm installed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 May 2004 Resolved
Label means of escape "Keep Clear" on outer deck LEGACY COMPONENT DESC: Means of Escape
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 1 June 2004
Resolution: Lable installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 May 2004 Resolved
Repair escape hatch hinges and gasket. LEGACY COMPONENT DESC: Hinges
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 1 June 2004
Resolution: Hinges installed.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 4 May 2004 Resolved
Provide first aid/CPR card IAW NVIC 1-91. LEGACY COMPONENT DESC: CPR Certified Personnel
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 1 June 2004
Resolution: CPR cards provided.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 4 May 2004 Resolved
Provide FCC operator permit. LEGACY COMPONENT DESC: FCC Operator Permit
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 1 June 2004
Resolution: Permitt provided.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 May 2004 Resolved
Provide proof of COD. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 6 May 2004
Resolution: Doc provided.
Communications › Radio Communications
Issued 18 April 2003 Resolved
Provide FCC Marine Radio Operator Permit as required by 47 CFR part 80.
Due 18 May 2003
Resolved 2 May 2003
Resolution: FCC operators permit provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 April 2003 Resolved
Provide CPR card for 50% of Crew as required by NVIC 1-91.
Due 18 May 2003
Resolved 2 May 2003
Resolution: First aid/CPRcards provided.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 April 2003 Resolved
Remove mop handles and debris from steering compartment as required by 46 CFR 176.818.
Due 18 May 2003
Resolved 2 May 2003
Resolution: Debris cleared from steering room.
Lifesaving › Hand Flares
Issued 28 March 2002 Resolved
REPLACE 2 EXPIRED ORANGE SMOKE DISTRESS SIGNALS. LEGACY COMPONENT DESC: Condition
Due 28 March 2002
Resolved 28 March 2002
Resolution: REPLACED AND FOUND SATISFACTORY DURING INSPECTION.
Construction/Loadline
Issued 29 March 2001 Resolved
MAKE ENGINE ROOM BULKHEADS AND OVERHEAD VAPOR TIGHT AS REQUIRED BY 46 CFR 185.612_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 29 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 29 March 2001 Resolved
PROVE WATERTIGHT INTEGRITY OF COLLISION BULKHEAD TO SATISFACTION OF A COASTGUARD MARINE INSPECTOR AS REQUIRED BY 46 CFR 176.802_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 29 April 2001
Resolved 23 April 2001
Navigation
Issued 29 March 2001 Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 29 April 2001
Resolved 23 April 2001
Navigation
Issued 29 March 2001 Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS AS REQUIRED BY 46 CFR 183.420
Condition: Unknown
Due 29 April 2001
Resolved 23 April 2001
Lifesaving
Issued 29 March 2001 Resolved
TOTAL NUMBER OF PERSON ONBOARD IS LIMITED TO 23 PERSONS, UNTIL SUFFICIENT LIFEJACKETS ARE ONBOARD AS REQUIRED BY 46 CFR 180.71
Condition: Unknown
Due 29 April 2001
Resolved 23 April 2001
Lifesaving
Issued 29 March 2001 Resolved
PROVIDE FIRST AID KIT AS REQUIRED BY 46 CFR 184.710
Condition: Unknown
Due 29 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 9 March 2000 Resolved
PROVIDE VAPORTIGHT CLOSURE IN ENGINE ROOM BULKHEAD
Condition: Unknown
Due 9 April 2000
Resolved 11 April 2000
Construction/Loadline
Issued 9 March 2000 Resolved
CROP AND RENEW AS ORIGINAL #3 DECK FRAME AFT OF STEM.
Condition: Unknown
Due 9 April 2000
Resolved 11 April 2000
Construction/Loadline
Issued 9 March 2000 Resolved
PROVIDE WATERTIGHT SEAL ON COLLISION BULKHEAD AS REQUIRED BY 46 CFR 171.114
Condition: Unknown
Due 9 April 2000
Resolved 11 April 2000
Construction/Loadline
Issued 5 February 1998 Resolved
PROVIDE AND INSTALL 12 INCH RAIL COURSES ON THE BOW RAIL AS PER_x001C_ 46 CFR 177. 35-1(B).
Condition: Unknown
Due 10 April 1998
Resolved 27 June 1998
Fire Fighting
Issued 8 April 1996 Resolved
PROVIDE 3EA 2.5 GALLON FIRE BUCKETS WITH LANYARD.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Lifesaving
Issued 8 April 1996 Resolved
PROVIDE & POST LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Engineering
Issued 8 April 1996 Resolved
PROVE PROPER OPERATION OF PORT ENGINE TACHOMETER.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Construction/Loadline
Issued 6 April 1996 Resolved
HULL REPAIRS COMPLETED DURING THIS DRYDOCK PERIOD SEE MINS CASE NUMBER MI96008438 FOR DETAILS
Condition: Unknown
Due 6 April 1996
Resolved 10 April 1996
Electrical
Issued 17 April 1995 Resolved
PROVIDE DOCUMENTATION AND PLACARD THAT GENERATOR HAS BEEN DERATED BY 20% IAW 46CFR183.10-5(F)(2).
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Lifesaving
Issued 17 April 1995 Resolved
RENEW TWO PADDLES FOR LIFE FLOAT.
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Accommodation/Occupational Safety
Issued 17 April 1995 Resolved
PROVIDE A MEANS TO DETERMINE WHEN MSD TANK IS 3/4 FULL IAW 33CFR159.83.
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Navigation
Issued 17 April 1995 Resolved
PROVIDE A BELL OF PROPER SIZE IAW 72 COLREGS ANNEX III (7.9" OR 200MM)._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Navigation
Issued 17 April 1995 Resolved
MOUNT MASTHEAD LIGHT SO THAT VISIBILITY IS 225 DEGREES ON OR AT HORIZON.
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Lifesaving
Issued 17 April 1995 Resolved
RENEW WORN RETROREFLECTIVE TAPE ON ADULT AND CHILD PFD'S.
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Lifesaving
Issued 17 April 1995 Resolved
REPAIR FRACTURE IN STBD LIFEFLOAT AND REPAINT BOTH LIFE FLOATS.
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Electrical
Issued 17 April 1995 Resolved
REMOVE HOUSEHOLD WIRING FROM BOAT (ROMEX CABLE) HOT WATER CIRCUIT.
Condition: Unknown
Due 15 May 1995
Resolved 28 June 1995
Navigation
Issued 17 April 1995 Resolved
DEMONSTRATE OPERATION OF SINGLE SIDE BAND RADIO, VSLS ROUTE RESTRICTED TO NOT MORE TWENTY (20) MILES FROM SHORE UNTIL REPAIRED AND PROVED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 April 1995
Resolved 28 April 1995
Electrical
Issued 21 September 1994 Resolved
REPLACE STBD SIDE BATTERY BOX; CORRODED AWAY.
Condition: Unknown
Due 21 September 1994
Resolved 26 October 1994
Construction/Loadline
Issued 21 September 1994 Resolved
PORT SIDE ENGINE ROOM. REPAIR #6, #7 FRAME. REPLACE #6 ANGLE SUPPORT BRACKET; SPLIT AT JOINT OF THE HORIZONTAL FRAME TO THE SIDE FRAME. DECAYING WOOD AT SIDE FRAMES #6 AND #7 HULL FRAMES.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Navigation
Issued 21 September 1994 Resolved
REPLACE RUDDER PACKING IN PORT AND STBD RUDDERS.
Condition: Unknown
Due 21 September 1994
Resolved 26 October 1994
Construction/Loadline
Issued 21 September 1994 Resolved
RECAULK PORT ENGINE ROOM BULKHEAD FORWARD BETWEED 1ST AND 3RD FRAMES ANT THE 3RD AND 4TH PLANK.
Condition: Unknown
Due 21 September 1994
Resolved 26 October 1994
Construction/Loadline
Issued 21 September 1994 Resolved
STBD ENGINE ROOM. REPLACE 4TH FRAME ANGE SUPPORT; ERRODED AWAY.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Engineering
Issued 11 April 1994 Resolved
PROVE PROPER OPERATION OF STARBAORD MAIN ENGINE COOLING WATER TEMPERATURE GUAGE.
Condition: Unknown
Due 25 April 1994
Resolved 27 April 1994
Lifesaving
Issued 11 April 1994 Resolved
RENEW RETRO TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 25 April 1994
Resolved 27 April 1994
Lifesaving
Issued 11 April 1994 Resolved
REPLACE 6 EACH EXPIRED RED FLARES.
Condition: Unknown
Due 25 April 1994
Resolved 27 April 1994
Navigation
Issued 11 April 1994 Resolved
PROVE PROPER OPERATION OF PORT NAVIGATION LIGHT.
Condition: Unknown
Due 25 April 1994
Resolved 27 April 1994
Lifesaving
Issued 11 April 1994 Resolved
REPAIR CRACK IN EPRIB CASING (BOTTOM)
Condition: Unknown
Due 25 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 11 April 1994 Resolved
PROVE PROPER OPERATION OF POWER BILGE PUMP.
Condition: Unknown
Due 25 April 1994
Resolved 27 April 1994
Unknown
Issued 15 May 1992 Resolved
DOUBLE HOSE CLAMP ALL SEA SUCTION FLEXIBLE HOSES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Fire Fighting
Issued 15 May 1992 Resolved
PROVIDE LONGER HOSE FOR PORTABLE FIRE/BILGE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Accommodation/Occupational Safety
Issued 15 May 1992 Resolved
SECURE MSD DISCHARGE IN CLOSED POSITION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Electrical
Issued 15 May 1992 Resolved
TIGHTEN UP BATTERY CABLE TO GENERATOR 12V SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Engineering
Issued 15 May 1992 Resolved
REATTACH GENERATOR EXHAUST MUFFLER TO ITS MOUNT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Electrical
Issued 15 May 1992 Resolved
REPAIR A/C GENERATOR AND PROVE ITS OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Electrical
Issued 15 May 1992 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Engineering
Issued 15 May 1992 Resolved
REATTACH LUBE OIL FILTER MOUNTS ON PORT AND STBD ENGINE AND REPAIR ALL LEAKS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Engineering
Issued 15 May 1992 Resolved
REPLACE LEAK ON PORT MAIN DIESEL ENGINE EXHAUST PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Lifesaving
Issued 15 May 1992 Resolved
CHANGE LIFE JACKET AMOUNT PLACARD TO REFLECT THE AMOUNT OF LIFE JACKETS ON BOARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Navigation
Issued 15 May 1992 Resolved
PROVE OPERATION OF SINGLE SIDE BAND RADIO._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Fire Fighting
Issued 15 May 1992 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Engineering
Issued 15 May 1992 Resolved
PROVIDE BONDING STRAPS TO BOTH PORT/STBD FUEL TANK FILLS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Engineering
Issued 15 May 1992 Resolved
DOUBLE HOSE CLAMP FLEXIBLE HOSE FOR GENERATOR EXHAUST SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Engineering
Issued 15 May 1992 Resolved
RENEW FLEXIBLE FUEL HOSE TO GENERATOR FUEL SYSTEM WITH ONES WITH FACTORY TYPE FITTINGS.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Lifesaving
Issued 18 April 1991 Resolved
PROVIDE SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN EXHAUST COOLING SYSTEM OF BOTH MAIN DIESEL ENGINES. SUCH WARNING SHALL BE BOTH VISIBLE AND AUDIBLE AT THE ENGINE OPERATING STATION._x001C_
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991 Resolved
INSTALL JUNCTION BOX FOR ELECTRICAL CONNECTIONS IN ELECTRICAL PANEL COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1991
Resolved 29 July 1991
Lifesaving
Issued 18 April 1991 Resolved
REPAIR NETTING ON BOTH LIFE FLOATS IAW 46 CFR 160.027._x001C_
Condition: Unknown
Due 18 May 1991
Resolved 29 July 1991
Electrical
Issued 18 April 1991 Resolved
PROVE OPERATION OF GENERATOR FREQUENCY METER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1991
Resolved 29 July 1991
Unknown
Issued 19 March 1987 Resolved
PROVE PROPER OPS OF FIXED MANIFOLD BILGE PUMP SYSTEM.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Fire Fighting
Issued 19 March 1987 Resolved
PROVIDE 1 ADDITIONAL B-II FIRE EXTINGUISHER WITH APPROVED BRACKET FOR ENGINE SPACE.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Electrical
Issued 19 March 1987 Resolved
DERATE GENERATOR TO 80% OF MAX LOAD -55 AMP BREAKER- AND PROVIDE NEW TAG IAW 46 CFR 183.60(F)(2).
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Documentation
Issued 19 March 1987 Resolved
PROVIDE EVIDENCE OF PRIOR STABILITY TEST OR UNDERGO A SIMPLIFIED STABILITY TEST.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987

Casualty record · 1

12 January 2023Routine · role: Involved in a Marine Casualty · activity 7621255
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record