MAURY USCG vessel records Sign in
← All vessels

CHAMPION EXPRESS

CHAMPION EXPRESS is a 1999 tank ship. The Coast Guard has recorded 44 inspections since 1999, most recently in September 2017, along with 9 deficiencies and 11 operational controls, 1 with no removal date recorded.

Records from 1999 to 2017. Most recent: operational control imposed, 13 September 2017.

Built
1999
Last inspected
13 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9143697 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
500754
Flag
LIBERIA
—
Maury page id
psix-500754

Inspections, by type

…with no type recorded21
Years with a record 13 calendar years (1999–2017)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22680 - Convention (Subpart B), Gross Ton
13120 - Convention (Subpart B), Net Ton
43157 - Dead Weight, Ton
51710 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

13 September 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6265995
6 September 2017 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260654
16 April 2016 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5852211
15 August 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5216374
14 August 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5218733
28 July 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5198928
24 July 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5197603
21 February 2012 PII Safety Exam · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4243841
20 February 2012 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4247856
17 February 2012 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4246736
24 November 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3898429
12 November 2010 Ballast Water Examination · ISPS I Exam · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3886520
8 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3886957
7 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3886518
11 January 2010 ISPS II Exam · COC-CHEM Annual · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3662342
7 September 2008 ISPS II Exam · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · Administrative Inspection · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3319268
1 September 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3315118
1 September 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320402
6 December 2007 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex II Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3110434
12 October 2007 MARPOL Annex I Examination · COC-CHEM Renew · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3078307
8 January 2006 ISPS III Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2562870
27 November 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2574242
24 November 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2540303
6 November 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2529261
28 October 2005 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2524131
23 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2520261
29 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2504061
22 September 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2498835
22 September 2005 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2498851
22 February 2005 COC-CHEM Annual
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2297204
14 October 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2220943
4 July 2004 ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2114893
7 January 2004 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1978538
24 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1825514
24 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1827592
24 January 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1735048
22 January 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1733526
21 January 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1732796
16 January 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1731758
4 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292490
4 August 2001 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1370319
20 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 173983
3 August 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 431385
3 August 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418583

Deficiency record · 9

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 12 November 2010 Resolved
1899 - Other (Tankers) -The system shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume in the inert gas supply main to the cargo tanks at any required rate of flow. Numerous attempts to operate the IG system were made unsuccessfully. Flame out alarm would energize prior to reaching 5% oxygen on every attempt. - FSS Ch 15 2.2.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2010
Resolution: Rcv''''d class report from RINA attesting to correction of item.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 16 January 2003 Resolved
Found in service without the required Chlorine treatment in place while within the port of NY
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 16 January 2003
Resolution: Corrected on the spot with a written warning issued to the shp''s master for violation of 33CFR159.
Personnel › Certificates/Documents/Licenses
Issued 16 January 2003 Resolved
No Italian endorsement on the Indian merchant mariner's License LEGACY COMPONENT DESC: License, Second Mate
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2003
Resolved 24 January 2003
Resolution: Satisfactory written documetation recieved from the Italian consulate for this mariner this date.
Personnel › Certificates/Documents/Licenses
Issued 16 January 2003 Resolved
No Italian endorsement on the Indian merchant mariner's License LEGACY COMPONENT DESC: License, Mate
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2003
Resolved 24 January 2003
Resolution: Satisfactory written documetation recieved from the Italian consulate for this mariner this date.
Personnel › Certificates/Documents/Licenses
Issued 16 January 2003 Resolved
No Italian endorsement on the Indian merchant mariner's License LEGACY COMPONENT DESC: License, First Assistant Engineer
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2003
Resolved 24 January 2003
Resolution: Satisfactory written documetation recieved from the Italian consulate for this mariner this date.
Personnel › Certificates/Documents/Licenses
Issued 16 January 2003 Resolved
No Italian endorsement on the Indian merchant mariner's License LEGACY COMPONENT DESC: License, Second Assistant Engineer
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2003
Resolved 24 January 2003
Resolution: Satisfactory written documetation recieved from the Italian consulate for this mariner this date.
Pollution Prevention/Response › Prevention Equipment
Issued 16 January 2003 Resolved
Sludge pump for ship's sludge incinerator inoperative. Repair to RINA satisfaction prior to departure from port of NY. MARPOL annex I LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 21 January 2003
Resolution: RINA Class report recieved this date attesting to corection of this deficiency
Documentation › Certificates/Documents
Issued 16 January 2003 Resolved
ISM SMC Issued by Italian govt. identified wrong vessel and deemed incorrect. This to be corrected priort o ddeprture from the port of NY by local IT Consulate to satisfaction of COTP NY. LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 22 January 2003
Resolution: Faxed copy of amended SMC recieved this office this date
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 January 2003 Resolved
Engine room main CO2 system found inopertive due to loose connections at main actuator assembly. Crew corercted on the spot after being shown how.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2003
Resolved 16 January 2003
Resolution: On the spot repair.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.