← All vessels
HIGH ENERGY
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named HIGH ENERGY
HIGH ENERGY is a 1992 freight ship. The Coast Guard has recorded 49 inspections since 1999, most recently in April 2024, along with 23 deficiencies and 9 operational controls.
Records from 1999 to 2024. Most recent: inspection, 6 April 2024.
- Built
- 1992
- Last inspected
- 6 April 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9012795 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8NS5
500988
Flag
LIBERIA
—
Maury page id
psix-500988
Inspections, by type
…with no type recorded19
Years with a record
13 calendar years (1999–2024)
The 49 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7361 - Convention (Subpart B), Gross Ton
3239 - Convention (Subpart B), Net Ton
13255 - Displacement, Ton
9200 - Dead Weight, Ton
3239 - Convention (Subpart B), Net Ton
13255 - Displacement, Ton
9200 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 49
6 April 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890930
26 February 2012
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4250552
24 February 2012
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4250411
19 January 2012
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4228236
19 January 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4228713
12 December 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4206433
1 September 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4156645
5 July 2011
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4069793
22 December 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3914755
1 December 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3902170
12 November 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3890141
24 October 2010
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3875377
29 September 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3859894
22 March 2010
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3700616
21 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3666325
21 January 2010
COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3667203
8 December 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3646486
11 May 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3472153
26 April 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3460933
10 April 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3449937
25 March 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3439853
13 March 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3430940
26 February 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3424559
12 February 2009
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3416714
31 January 2009
COE-Offshore · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3403085
31 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3403891
3 October 2008
PII Safety Exam · MARPOL Annex II Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3336479
26 February 2008
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 3154169
20 September 2007
ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3065099
17 September 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3059723
2 February 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2865888
1 February 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2865385
31 January 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2864473
28 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2575188
20 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2570196
12 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2565455
21 July 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2434629
7 July 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2418732
27 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2404477
2 May 2005
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2347685
14 April 2005
MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2328275
4 April 2005
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2325861
14 February 2002
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1486667
24 October 2001
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 772204
15 August 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 292854
28 August 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 281575
10 August 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 280870
16 May 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 277870
28 July 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 431195
Deficiency record · 23
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 February 2012
Resolved
DEF Code 0155- 33CFR159:
When operating a vessel on a body of water where discharge of treated or untreated sewage is prohibited the operator must secure each device.
Overboard discharge not secured.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 24 February 2012
Resolved
DEF Code 1721- 33CFR155.320:
A ship 300GT or more constructed after June 30 1974 must have a fixed containment around each fuel oil tank vent.
Containment under Fuel Oil tank vents, mid ship STBD side has a half inch diameter hole causing loss of containment.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 19 January 2012
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The vessel lost propultsion in transit to berth after loss of main engine. Casualty on main engine occurred as a result of suspected..SOLAS 04 I/11
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 5 July 2011
Resolved
Vessel anchored in Port Everglades anchorage more than 72 hours without requesting prior approval of the COTP (see 33 CFR 110.186(b)(6))
Construction/Loadline › Structures › Deck Plating
Issued 22 October 2010
Resolved
Ballast tank top damaged during container loading, #2 hold port side forward tank 4.06, 6 inch by 1 inch gash in tank top.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 22 October 2010
Resolved
Wasted fire damper stbd side front of house "deck workshop" and indicator switch completely ineffective.
Construction/Loadline › Structures › Superstructure
Issued 22 October 2010
Resolved
Port bunker containment on front of house has a hole between bunker station and accomodation space.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 October 2010
Resolved
Paint located in foc'sle room (approx 40 5gal and 18 1gal pails) needs to be moved to paint locker.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 October 2010
Resolved
Dead end wire found located forward of port vent trunk between Bay 13 and 15. Cable run housing forward of Bay 15 is wasted, causing chaffing of cable.
Electrical › Lighting (service) › Switch
Issued 22 October 2010
Resolved
Light switch located forward of Bay 15 is hanging.
Construction/Loadline › Penetrations › Gasket
Issued 22 October 2010
Resolved
Port side aft hatch cover 17 gasket is ineffective and cannot maintain watertight integrity.
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 22 October 2010
Resolved
Totally enclosed lifeboat shall be provided with a rigid watertight enclosure which completely encloses the lifeboat. Lifeboat window is cracked.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 October 2010
Resolved
Lifesaving appliances shall be clearly marked with approval information. Life jackets do not indicate approval information.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 October 2010
Resolved
Leak was observed on HFO valve on bunker line fwd of Bay 15. Additionallty, missing valve handles on stbd side bunker piping fwd of Bay 15.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 October 2008
Resolved
Fire ensembles are not for fire entry. Provide two fire ensembles which protect from scalding, steam and radiating heat.
Fire Fighting › Firemans Outfit › Lifeline
Issued 3 October 2008
Resolved
Firemens tending line is not fire proof. Provide two fire proof lifelines.
Electrical › Electric Generation Source (emergency) › Generator
Issued 20 September 2007
Resolved
Crew could not demonstrate 02 means of starting generator.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 17 September 2007
Resolved
Vessel to repair starboad anchor winch.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 14 April 2005
Resolved
Oxygen cylinder for medical use in sickbay/hospital space unsecured. Cylinder lashed to cabinet door handle and bedstead. Provide proper mounting bracket.
Fire Fighting
Issued 15 August 2001
Resolved
Provide report of repaired fire control/detection panel by repair facility to USCG Marine Safety Office. Ensure watches are maintained IAW vsl's standing orders until repaired.
Engineering
Issued 10 August 2000
Resolved
Soft patch was on salt water cooling pump discharge line. Have class address deficiency prior to 09sept.00.
Lifesaving
Issued 28 July 1999
Resolved
VESSEL'S LIFERAFTS WERE IMPROEPERLY STOWED IN THEIR CRADLES, SITUATION WAS RECTIFIED PRIOR TO COMPLETION OF EXAM.
Fire Fighting
Issued 28 July 1999
Resolved
VESSEL MISSING THE REQUIRED GASKETS AND NUTS & BOLTS FOR THE INTERNATIONAL SHORE CONNECTIONS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.