Records from 1981 to 1995. Most recent: inspection, 3 March 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
3 March 1995
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 855560
2 May 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 112857
7 January 1994
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850442
14 April 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 838062
1 March 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839653
12 January 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137143
29 October 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1270058
12 March 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1269924
4 February 1992
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 953484
20 January 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942927
28 January 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1305616
25 April 1990
Excursion Permit
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 925516
1 March 1990
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1241481
1 February 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1238685
2 January 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 921534
15 December 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1244647
12 July 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347328
3 July 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 896606
21 June 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1352301
7 January 1989
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036985
22 March 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208749
10 September 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004576
30 June 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333165
3 November 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323918
21 May 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296752
28 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985408
24 July 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280528
24 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278447
11 June 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272807
Lifesaving
Issued 12 January 1993
Resolved
PROVIDE CATEGORY I EPIRB.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Navigation
Issued 12 January 1993
Resolved
REPAIR ENGINE ROOM RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Engineering
Issued 12 January 1993
Resolved
DETERMINE PROBLEM WITH LOW STARTING AIR INDICATOR LIGHT AND REPAIR SAME.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Accommodation/Occupational Safety
Issued 12 March 1992
Resolved
EFFECT PERMANENT REPAIRS TO MARINE SANITATION DEVICE VENT LINE.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992
Resolved
PROVIDE COPY OF A.B.S. RECOMMENDATIONS REGARDING CG-835 ITEM #1 DATED 12 MAR 1992 TO MARINE SAFETY OFFICE MIAMI.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992
Resolved
SUBMIT REPORT OF SURVEY PERFORMED BY FLORIDA DETROIT DIESEL-ALLISON ON #1, #2, AND #3 GENERATORS (W/O #040902) TO A.B.S. FOR THEIR RECOMMENDATIONS.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Navigation
Issued 12 March 1992
Resolved
REPAIR ENGINE ROOM RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Accommodation/Occupational Safety
Issued 12 March 1992
Resolved
REMOVE HOSE IN SANITARY SUCTION LINE AND REPLACE WITH METALLIC PIPE.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 28 January 1991
Resolved
SUBMIT ONE LINE ELECTRICAL DRAWINGS AND BILL OF MATERIALS TO [name withheld]_x001C_ CITY FOR: GRIDDLE, STOVE, BLOWER INSTALLATIONS. SHOW REMOTE DISCONNECTS _x001C_ AND BLOWER SHUTDOWNS ON ENGINE ROOM BLOWER.
Condition: Unknown
Due 19 April 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 28 January 1991
Resolved
PROVIDE ON BOARD MANUFACUTURES OPERATION MANUAL FOR RED FOX SEWAGE SYSTEM.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Electrical
Issued 1 February 1990
Resolved
PROVIDE SOUND POWERED PHONE COMMUNICATIONS IN AFTER STEERING COMPARTMENT. (LAZARETTE)
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Fire Fighting
Issued 1 February 1990
Resolved
HAVE ALL FIRE EXTINGUISHERS ANNUALLY SERVICED.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Electrical
Issued 1 February 1990
Resolved
REPAIR INOPERATIVE ALARMS TO ENGINE ROOM ALARM BOX AS NECESSARY.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Lifesaving
Issued 1 February 1990
Resolved
PROVIDE 1 ADDITIONAL APPROVED LIGHT FOR 1 LIFE JACKET.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Fire Fighting
Issued 1 February 1990
Resolved
PROVIDE PROPER BRACKETS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Construction/Loadline
Issued 2 January 1990
Resolved
EFFECT PERMANENT REPAIRS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR TO NO. 4 FUEL TANK BULKHEADS BETWEEN FRAMES 39-45 IN WAY OF ALLEYWAY FROM BOTTOM PLATE UPWARD TO GOOD METAL. NO FUEL OR CARGO OIL TO BE CARRIED IN THIS TANK UNTIL PERMANENT REPAIRS ARE COMPLETED.
Condition: Unknown
Due 2 January 1990
Resolved 2 January 1990
Construction/Loadline
Issued 2 January 1990
Resolved
MAKE NO. 5 FUEL TANK AVAILABLE FOR INTERNAL EXAMINATION BY A MARINE INSPEC-TOR.
Condition: Unknown
Due 2 January 1990
Resolved 2 January 1990
Unknown
Issued 7 January 1989
Resolved
HAVE VESSEL'S DOCUMENT CORRECTED TO SHOW THE VESSEL'S CORRECTED GROSS AND NET TONS AS SHOWN ON THE CURRENT ADMEASUREMENT CERTIFICATE ISSUED 28DEC88.
Condition: Unknown
Due 7 January 1989
Resolved 7 January 1989
Deck/Cargo
Issued 3 November 1986
Resolved
PROVIDE INDENTIFICATION DATA PLATES FOR ALL BULK MUD TANK PRESSURE VESSELS PRIOR TO RETURNING TANKS TO CARGO SERVICE.
Condition: Unknown
Due 3 November 1986
Resolved 3 November 1986
Deck/Cargo
Issued 21 May 1986
Resolved
PROVIDE IDENTIFICATION DATA PLATES FOR ALL BULK MUD TANK PRESSURE VESSEL.
Condition: Unknown
Due 21 May 1986
Resolved 21 May 1986
Documentation
Issued 21 May 1986
Resolved
PROVIDE A FUEL OIL LTRANSFER PROCEDURE IN ACCORDANCE WITH 33CFR155.720 USE 33CFR155.750 AS A CONTENT GUIDE.
Condition: Unknown
Due 21 May 1986
Resolved 21 May 1986
Unknown
Issued 24 July 1984
Resolved
PROVIDE ON BOARD TWO ANCHORS AND CHAINS AS REQUIRED BY THE CLASSIFICATION SOCIETY.
Condition: Unknown
Due 24 July 1984
Resolved 24 July 1984