MAURY USCG vessel records Sign in
← All vessels

SANTA ROSA

SANTA ROSA is a 1979 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1982, most recently in January 2012, along with 85 deficiencies and 1 casualty investigation in 2013.

Records from 1982 to 2013. Most recent: casualty investigation, 9 June 2013.

Built
1979
Last inspected
6 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCL5694
Flag
UNITED STATES
366960970, 367498850 (licence lapsed)
Maury page id
psix-50115

Inspections, by type

…with no type recorded15
Years with a record 28 calendar years (1982–2012)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
94 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF8813MMSI 367498850 · expired · compulsorily equipped · granted 13 July 2011, cancelled 9 October 2021
WCL5694MMSI 366960970 · expired · compulsorily equipped · granted 1 July 2004, cancelled 18 October 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

6 January 2012 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4219831
4 August 2011 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4086037
12 February 2009 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3416668
14 February 2008 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3147526
14 November 2007 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3098253
15 March 2007 COI Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2888398
26 January 2006 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2577480
7 September 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2189098
23 February 2004 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2021201
18 November 2003 Hull Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1955061
3 February 2003 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1739164
4 April 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1601110
3 April 2002 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1600600
2 April 2002 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1600565
27 March 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1059984
16 February 2001 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1413876
10 February 2001 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1521933
16 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 501806
8 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 466036
5 April 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 817605
24 March 2000 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1406672
3 May 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 793585
1 April 1999 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1429117
28 May 1998 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 794962
28 May 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421502
11 May 1998 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1450157
9 September 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1121475
20 August 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 783563
27 May 1997 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 775827
12 May 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421321
31 May 1996 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1084220
14 May 1996 Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1419613
28 November 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 880801
16 June 1995 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1357201
14 July 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 869387
21 June 1994 COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1447364
10 August 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849988
8 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960106
8 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261095
28 November 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 919504
21 November 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903742
13 September 1990 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909806
2 January 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909520
2 January 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239415
5 September 1989 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1201098
3 May 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349589
1 September 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198722
3 March 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1029173
31 August 1987 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1310173
15 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319002
28 August 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311614
26 August 1985 Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 990971
16 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281699
26 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972664
29 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271669
18 March 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 968858
19 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273759

Deficiency record · 85

Construction/Loadline › Hull › Hull Plating
Issued 14 November 2007 Resolved
Renew corrision on stbd side long frame just below A/C unit in fwd lounge, and long just below stbd exhaust pipe in eng room.
Action required: 705 - Other - as specified
Resolved 19 November 2007
Resolution: Area has been properly renewed and inspected.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 November 2007 Resolved
Renew wasted plate from old hyd lines in collision bulkhead.
Action required: 705 - Other - as specified
Resolved 19 November 2007
Resolution: A new insert has been installed properly and inspected.
Engineering › Steering Gear System › Rudder Bearing
Issued 14 November 2007 Resolved
Renew stbd rudder post cutlass bearing
Action required: 705 - Other - as specified
Resolved 19 November 2007
Resolution: New cutlass bearings have been installed.
Communications › Visual Communication
Issued 23 February 2004 Resolved
Employee Assistance Program informational materials were missing. Specifically, company policy regarding drug and alcohol use in the workplace and EAP hot-line number.
Condition: Unknown
Due 23 March 2004
Resolved 8 March 2004
Resolution: Company policy and hot-line info were posted on-board the vessel.
Electrical › Electrical Distribution System (service) › Conductor
Issued 23 February 2004 Resolved
Replace zip ties and hose clamps on electrical wiring (throughout engine room) with approved straps and cable supports.
Condition: Improper Installation
Due 23 March 2004
Resolved 28 November 2005
Fire Fighting › Emergency Fire Pumps
Issued 23 February 2004 Resolved
Auxiliary fire pump frozen. Prove proper operation or demonstrate that the starboard fire station may be operated using the main power driven fire pump.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2004
Resolved 8 March 2004
Resolution: Pump was repaired and pressure at starboard fire station was satisfactory.
Construction/Loadline › Hull
Issued 18 November 2003 Resolved
Repair puncture on transom, 2.5 ft above waterline.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Construction/Loadline › Structures
Issued 18 November 2003 Resolved
Repair weld fractures on transom framing.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Construction/Loadline › Hull
Issued 18 November 2003 Resolved
Repair punctures in raised deck coaming.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 18 November 2003 Resolved
Replace engine room light covers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Engineering › Fuel Oil Service System › Piping
Issued 18 November 2003 Resolved
Repair fuel leak at "T" fitting located in engine room bilge.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Pollution Prevention/Response
Issued 18 November 2003 Resolved
Remove fuel from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Stability › Watertight Integrity
Issued 18 November 2003 Resolved
Seal open wire tubes in transverse bulkhead (engine room/generator room).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 November 2003 Resolved
Repair high bilge water alarm for generator room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 November 2003 Resolved
Relocate hose laying on top of engine room high bilge water alarm to allow the float switch to rise and sound the alarm in the event of rising water in the bilge.,
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 February 2003 Resolved
One CO2 bottle removed to be hydro tested, cleared, serviced and returned to vessel when complete. LEGACY COMPONENT DESC: Service
Condition: Unknown
Due 3 March 2003
Resolved 2 April 2003
Resolution: CO2 bottle installed
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 February 2003 Resolved
Center engine remote shutdown not functioning, needs to be repaired.
Condition: Unknown
Due 3 March 2003
Resolved 4 March 2003
Resolution: Remote shutdown repaired and operating properly.
Fire Fighting › Fire Hydrants
Issued 3 February 2003 Resolved
Secondary Fire station coupling fractured and requires replacement or welding. LEGACY COMPONENT DESC: Condition
Condition: Damaged By Earlier Event
Due 3 March 2003
Resolved 2 April 2003
Resolution: Fire station repaired and operated properly.
Personnel › Training
Issued 2 April 2002 Resolved
CPR cards expired for MAR02 need to be renewed. LEGACY COMPONENT DESC: First Aid/CPR
Condition: Unknown
Due 22 April 2002
Resolved 24 November 2003
Navigation › Piloting/Steering
Issued 2 April 2002 Resolved
Vessel requires a Rules of Road manual on board. LEGACY COMPONENT DESC: Inland Navigation Rules
Condition: Unknown
Due 22 April 2002
Resolved 3 April 2002
Resolution: New nav rules manual on board.
Fire Fighting › Ventilation Systems
Issued 2 April 2002 Resolved
Install securing latches on engine and generator room vents, # 2, #3, and #4. LEGACY COMPONENT DESC: Ducts
Condition: Unknown
Due 22 April 2002
Resolved 3 April 2002
Resolution: Securing latches installed
Engineering › Diesel Engine (propulsion-electric)
Issued 2 April 2002 Resolved
Engine exhaust line connectors need to be double clamped. LEGACY COMPONENT DESC: Silencer (exhaust)
Condition: Unknown
Due 22 April 2002
Resolved 3 April 2002
Resolution: Double clamps installed.
Construction/Loadline › Hull
Issued 2 April 2002 Resolved
Install new side shell insert on port generator exhaust area due to fractures. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Due 2 May 2002
Resolved 3 April 2002
Resolution: Side shell insert installed and checked.
Documentation › Logs/Records
Issued 2 April 2002 Resolved
Garbage log not avialable, must be maintained on the vessel, LEGACY COMPONENT DESC: Garbage Recordkeeping
Condition: Unknown
Due 22 April 2002
Resolved 3 April 2002
Resolution: Log is on board vessel.
Electrical
Issued 16 February 2001 Resolved
Renew light lens covers in engine room. ( broken covers )
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Construction/Loadline
Issued 16 February 2001 Resolved
Repair end caps for life line piping located in overhead of generator room.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Re-wrap port generator exhaust piping and provide exhaust wrap for stbd generator flange.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Accommodation/Occupational Safety
Issued 16 February 2001 Resolved
Lable all emergency exits.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Construction/Loadline
Issued 16 February 2001 Resolved
Provide dog handle for fwd compartment exit to main deck.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Construction/Loadline
Issued 16 February 2001 Resolved
Repair cracked port and stbd stern radius bulwarks and ru-misdb rails.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001 Resolved
Provide training log and epirb log I.A.W. 46CFR185
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001 Resolved
Provide lifejacket and emergency broadcast placards I.A.W. 46CFR185
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Provide plugs for drain line on lube oil tank located in generator room.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Provide caps for main engine oil drain lines.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Navigation
Issued 16 February 2001 Resolved
Provide updated coastal pilot and tide tables.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Repair mounting bracket to stbd main engine air intake/air filter.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Documentation
Issued 16 February 2001 Resolved
Provide in date FCC Safety Certificate.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Accommodation/Occupational Safety
Issued 16 February 2001 Resolved
Install permanently fixed piping/hoses for washer discharge line.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Provide flame screens for missing racor filters.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Accommodation/Occupational Safety
Issued 16 February 2001 Resolved
Repair broken pipe supports located in engine room above port and stbd engines.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001 Resolved
Mark all ring bouys with reflective tape.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Fire Fighting
Issued 16 February 2001 Resolved
Provide machinery guard for fire pump.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Permanently repair exhaust leak on stbd main engine overboard muffler.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Remove petcocks and provide plugs on all fuel oil filters.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 24 March 2000 Resolved
PROVIDE RESCUE PLATFORM, SAFETY HARNESS/CLIP, AND BACKBOARD OR JACOBS CRADLE IAW 46 CFR 180.210.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Lifesaving
Issued 1 April 1999 Resolved
Vessel is required to have 49 PFDs, found two were unacceptable. Vessel is restricted to carry a maximum of 47 POB, until two new PFDs are brought aboard to replaced the rejected ones.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Lifesaving
Issued 1 April 1999 Resolved
THE LIFE FLOATS PAINTER IS BE RENEWED AS REQUIRED IN 46 CFR 180.175.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Lifesaving
Issued 28 May 1998 Resolved
Lifefloat paddle is fractured. Needs to be replaced.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 28 May 1998 Resolved
PFD's need to have vessels name restenciled.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 28 May 1998 Resolved
Waterlight on ring buoy, has cracked casing and is inoperative. Needs to bereplaced.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Electrical
Issued 28 May 1998 Resolved
Port generator overspeed trip control inoperative. Make repairs, and test to satisfaction of Marine Inspector.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
Antenna in front of port running light has to be removed.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 28 May 1998 Resolved
Vessel name on ringbuoys have to be restenciled._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Deck/Cargo
Issued 11 May 1998 Resolved
REPLACE WASTED ANCHOR SHACKLES.
Condition: Unknown
Due 30 May 1998
Resolved 14 May 1998
Electrical
Issued 11 May 1998 Resolved
AFT INBOARD GENERATOR MOUNT CRACKED.
Condition: Unknown
Due 30 May 1998
Resolved 14 May 1998
Unknown
Issued 11 May 1998 Resolved
GOOSENECK FLOAT BALL MISSING - PORT SIDE - 3RD VENT BACK FROM BOW.
Condition: Unknown
Due 30 May 1998
Resolved 14 May 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
CABIN WINDOW CRACKED - PORT SIDE - SECOND WINDOW BACK FROM BOW.
Condition: Unknown
Due 30 May 1998
Resolved 14 May 1998
Construction/Loadline
Issued 11 May 1998 Resolved
FORWARD EMERGENCY EGRESS ESCAPE DOOR GASKET WASTED.
Condition: Unknown
Due 30 May 1998
Resolved 14 May 1998
Engineering
Issued 11 May 1998 Resolved
SMALL FRACTURE IN WELD PORT SIDE EXHAUST SUPPORT BRACKET.
Condition: Unknown
Due 30 May 1998
Resolved 14 May 1998
Lifesaving
Issued 20 August 1997 Resolved
REMOVE FLAMMABLE MATERIALS (SPRAY LUBRICANTS, ETC.) FROM CLOSET IN GALLEY AND OIL BUCKETS FROM ENGINE ROOM AND PROPERLY STOW._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Electrical
Issued 20 August 1997 Resolved
REMOVE ALL DEAD END WIRES AND MAKE PROPER REPAIRS TO CIRCUIT BREAKER PANELS, FWD END (P/S) OF AFT MACHINERY SPACE.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Electrical
Issued 20 August 1997 Resolved
PROVIDE METAL STRAPS TO HOLD ELECTRICAL WIRES TO OVERHEAD THROUGHOUT ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Electrical
Issued 12 May 1997 Resolved
Test overspeed trip on tarboard generator.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Electrical
Issued 12 May 1997 Resolved
Clean air filter cannisters on both generators._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Electrical
Issued 12 May 1997 Resolved
Clean exhaust fans located in the engine room and the generator room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1997
Resolved 16 May 1997
Documentation
Issued 12 May 1997 Resolved
Provide curent up to date operator license. License to bprovided prior to vessel getting underway.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Electrical
Issued 14 May 1996 Resolved
INSTALL ELECTRICAL BLANKS IN FORWARD PASSENGER AREA CIRCUIT PANEL.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Fire Fighting
Issued 14 May 1996 Resolved
CONDUCT HYDRO TEST PORTABLE FIRE EXTINGUISHER. EXTINGUISHER LOCATED IN RUDDER ROOM. HYDRO DUE THE END OF THIS MONTH
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Construction/Loadline
Issued 14 May 1996 Resolved
INSTALL COTTER PINS ON END SHAFTS, TO KEEP NUTS IN PLACE, ON STARBOARD AND CENTER SHAFTS. TO BE COMPLETED PRIOR TO VESSEL ENTERING THE WATER.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Engineering
Issued 14 May 1996 Resolved
MAKE REPAIRS TO FUEL VENT GOOSE NECK, GOOSENECK HAS A 1/2" FRACTURE.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Construction/Loadline
Issued 14 May 1996 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE ON PORT SIDE, TRANSVERSE FRAME, AFT AREAOF THE FOREPEAK.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Unknown
Issued 21 June 1994 Resolved
Post required emergency instructions.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Electrical
Issued 21 June 1994 Resolved
Install blanks on electrical circuit box located in generator room forward bulkhead.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Navigation
Issued 21 June 1994 Resolved
Install loran unit or equivalent navigational equipment.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Unknown
Issued 21 June 1994 Resolved
Provide and post vessel's stability letter.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Unknown
Issued 21 June 1994 Resolved
Provide to [name withheld]. an up to date Certificate of Documentation.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Engineering
Issued 21 June 1994 Resolved
Install handle on raycor filter fuel intake line on center engine.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Unknown
Issued 21 June 1994 Resolved
Renew engine exhaust flex coupling on port side of engine room.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Electrical
Issued 21 June 1994 Resolved
Remove or properly secure open wires located in aft pilot station starboardside.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Engineering
Issued 13 September 1990 Resolved
INSTALL MARINE APPROVED FILTERS ON PORT CENTER AND STARBOARD MAIN ENGINES AND PORT AND STARBOARD GENERATORS.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Navigation
Issued 13 September 1990 Resolved
DERATE TWO HYDRAULIC STEERING PUMPS PER 46 CFR 183.10-5.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Electrical
Issued 13 September 1990 Resolved
INSTALL BLANK IN ELECTRICAL PANEL OF LAZARRETTE AND FORWARD PASSENGER AREA.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Navigation
Issued 2 January 1990 Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO. VESSEL ROUTE LIMITED TO NOT MORE THAN TWENTY (20) MILES FROM A HARBOR OF SAFE REFUGE PENDING REPAIROF CHANNEL 2182. REQUIREMENT WAS TO BE COMPLIED WITH BY 09JAN90.
Condition: Unknown
Due 2 January 1990
Resolved 2 January 1990
Documentation
Issued 28 August 1986 Resolved
PROVIDE A CORRECTED STABILITY LETTER WHICH SHOWS THE CORRECT LOCATION OF WATERTIGHT DOORS IN SUBDIVISION BULKHEADS.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Lifesaving
Issued 18 March 1983 Resolved
REPLACE 11 MAN LIFEFLOAT WITH 15 MAN LIFEFLOAT; UNTIL LIFEFLOAT IS REPLACED TOTAL PERSONS ON BOARD IS REDUCED TO 50.
Condition: Unknown
Due 18 March 1983
Resolved 18 March 1983

Casualty record · 1

9 June 2013Routine · role: Involved in a Marine Casualty · activity 4622937
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.