Records from 1985 to 2026. Most recent: inspection, 17 February 2026.
Inspection history · 67
17 February 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299449
4 November 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8264313
5 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8076012
5 March 2024
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868464
12 December 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7838268
14 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7638413
4 January 2023
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7616574
16 March 2022
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412738
10 November 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7349979
24 July 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7267065
24 July 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7269325
29 April 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7185973
2 March 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7149153
4 March 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6920120
3 December 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6865502
21 February 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6630123
5 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6366475
24 January 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6342545
2 March 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6093025
22 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6046014
15 September 2016
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6005071
9 March 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5973463
25 May 2012
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4322822
26 September 2011
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4154926
10 January 2011
Liferaft Servicing
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3945718
22 September 2010
Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3854913
3 September 2008
Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3317013
1 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3070455
24 April 2007
Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2914916
3 October 2006
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2792894
26 October 2005
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2522524
13 April 2005
Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2333191
18 May 2004
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2071397
27 May 2003
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1803863
12 May 2003
Plan Review "T" Boat · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1791840
29 April 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1614065
22 April 2002
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1605937
20 March 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1427987
3 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369565
30 March 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395152
26 March 1998
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1408076
11 April 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380825
9 April 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396495
6 December 1995
Deficiency Check · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374448
3 May 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1197031
31 March 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430020
22 April 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1167052
1 April 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 856583
4 October 1993
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1134415
27 April 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1143583
30 April 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1264707
26 March 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1262867
30 September 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 936552
22 April 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998700
18 October 1990
Plan Review "T" Boat
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 926841
28 September 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1234069
10 April 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 920670
6 May 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339344
2 May 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1205355
1 August 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1038019
23 June 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 892623
20 January 1988
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1324324
10 June 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340720
7 April 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1021931
22 October 1986
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318691
26 June 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 994423
19 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 987914
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 5 March 2025
Resolved
Electrical cable penetrating an enclosure is to be secured against strain. wiring in seat boxes are not secured against strain at the enclosures. Properly secure cable at the enclosures. 46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Verified correction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. O/o is to ensure drills are conducted at a minimum of three month intervals and that adequate details of the trainings are recorded.
Action required: 10 - Deficiency Rectified
Due 5 March 2025
Resolved 5 March 2025
Resolution: O/O provided log book for future use.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2025
Resolved
Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. O/o was unable to present logs proving the tests were being conducted or recorded. O/o is to start conducting and recording tests as required.
Action required: 10 - Deficiency Rectified
Due 5 March 2025
Resolved 5 March 2025
Resolution: O/O provided log books for future use.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 March 2024
Resolved
47CFR 80.903: Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Communications Act Radiotelephony Certificates may be obtained from the Commission's National Call Center—(888) 225–5322—or from its forms contractor.
FCC Radio Telephony Certificate was expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 March 2024
Resolved
46CFR 185.304(a)(8): The movement of vessel shall be under the direction and control of the master or a licensed mate at all times. The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to prevent a casualty. Special attention should be paid to: Magnetic variation and deviation errors of the compass.
Magnetic compass deviation chart was last updated in 1991. Observed physical and digital magnetic compass displaying different directions with a ten degree deviation.
Deviation table is no longer valid. Provide updated deviation table.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 15 March 2024
Resolution: Observed updated deviation table onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 March 2024
Resolved
46CFR 183.430: Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
VSL O/O was unable to locate two portable lights to be utilized near operating station and machinery space.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 15 March 2024
Resolution: Two portable lights provided.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 March 2024
Resolved
46CFR 179.360(b)(2): A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Aft. Freeman Hatch was not secured to the deck with any means.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 5 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2020
Resolved
The required ring buoy water light was inoperable, not meeting the requirements of subchapter Q. Provide an approved floating water light.
46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo sent providing an approved water light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 March 2020
Resolved
The required lifeline attached to the ring buoy must be dark in color and have a breaking strength of 1,124 pounds. Replace with a line meeting the requirements.
46CFR180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo sent documenting a new lifeline.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 March 2020
Resolved
Vessel over 26' must have an oil pollution placard. Provide a placard and mount in a location to be read by crew and passengers.
33CFR151.59(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo documentation of an oil placard sent.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020
Resolved
Fuel tank shut off valve markings on the port and starboard fuel tanks were broken up and difficult to read. Replace with appropriate sized markings.
46CFR185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo documentation submitted of new fuel oil shut off valve markings.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 February 2019
Resolved
Provide a company corrective action plan to ensure compliance with records and logs. To-date, drill, training, and emergency equipment maintenance logs were not on board company vessels at the time of inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 25 March 2019
Resolution: POC provided evidence of maintenance and drill logs via email/photos
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2019
Resolved
Complete DAPI audit conducted by USCG
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2019
Resolved 11 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 February 2019
Resolved
Provide updated and corrected charts
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 25 March 2019
Resolution: POC provided photos of updated charts for vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 February 2019
Resolved
Provide means for measuring frequency for the A/C generator
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 15 March 2019
Resolution: POC sent photo of functioning HZ meter
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 March 2017
Resolved
Certificate of Documentation in pending status; no valid COD onboard. Vessel provide valid COD.
Condition: Invalid
Due 2 April 2017
Resolved 7 March 2017
Construction/Loadline › Hull › Hull Plating
Issued 15 September 2016
Resolved
Complete credit Dry-Dock Exam (DDX) by 30NOV2016.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 22 November 2016
Resolution: Examined hull exterior. Hull is fair, no deflection noted. Hull coating intact. Both water lubricated shaft bearings were within tolerance. Propellers were off for routine maintenance. Rudders and rudder packing appeared in good condition.
Examined
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 26 September 2011
Resolved
Install new flame screens on both fuel vent lines on port and starboard sides. Venting was oxidized and painted in areas.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 25 May 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 September 2011
Resolved
Perform fire, abandon ship, mob, first aid drills prior to next operating season.
Action required: 705 - Other - as specified
Due 15 October 2011
Resolved 23 May 2013
Construction/Loadline › Hull › Side Shell
Issued 22 September 2010
Resolved
Repair worn gel coat at bow near waterline and stern in way of port side shell approx 2 feet above waterline. Repairs to be completed by 10May 2011, or if not completed by then, prior to carrying passengers. Repairs to be completed to the satisfaction of the attending marine inspector. Ensure initial inspection happens after sanding but before fiberglass is applied.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2011
Resolved 9 May 2011
Resolution: Inspected fiberglass in question, all sat.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 13 April 2005
Resolved
Perform vessel's emergency drills with season employees (new hires) NLT June 30 2005. Fire & abandon ship drills including general safety briefing by the crew.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 2 June 2005
Resolution: Conducted drills satisfactorily.
Operations/Management › Drills/Instruction › Fire
Issued 13 April 2005
Resolved
To conduct with new hires.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 28 April 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 May 2004
Resolved
No bonding strip for fuel fill IAW 46CFR182.445(g).
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 18 June 2004
Resolution: Bonding strips were inserted.
Electrical › Electrical Distribution System (service)
Issued 27 May 2003
Resolved
Permanently secure the ground wire from the power inverter located in the tank room. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 May 2003
Resolution: Ground wire secured.
Personnel › Training
Issued 27 May 2003
Resolved
Demonstrate crew proficiency in conducting emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2003
Resolution: Drills conducted satisfactorily.
Personnel › Certificates/Documents/Licenses
Issued 27 May 2003
Resolved
Ensure that 50 % of the crew hold valid CPR Cards. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2003
Resolution: 50% of crew have CPR cards.
Operations/Management › Drug and Alcohol Testing
Issued 27 May 2003
Resolved
Provide proof of participation in a random drug and alcohol program. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Resolved 28 May 2003
Resolution: Proof of paticipation provided.
Documentation › Certificates/Documents
Issued 27 May 2003
Resolved
Provide servicing certificates for both the liferaft and fire extinguishing systems.
Action required: 705 - Other - as specified
Resolved 28 May 2003
Resolution: Certificates provided.
Navigation › Collision/Grounding Avoidance
Issued 27 May 2003
Resolved
Install a proper sized bell.
Action required: 705 - Other - as specified
Resolved 28 May 2003
Resolution: Bell installed.
Engineering › Steering Gear System
Issued 27 May 2003
Resolved
Install chafing gear to affected areas of copper tubing in the hydraulic steering system.
Action required: 705 - Other - as specified
Resolved 28 May 2003
Resolution: Chafing gear installed.
Lifesaving
Issued 31 March 1995
Resolved
PROVIDE 1 ADDITIONAL CHILDS LIFEJACKET. VESSEL IS RESTRICTED TO THE CARRIAGE OF 5 CHILDREN UNTIL THE UNSERVICEABLE JACKET IS REPLACED.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Accommodation/Occupational Safety
Issued 31 March 1995
Resolved
REPAIR AFT RAILING. PASSENGERS RESTRICTED FROM AFTER DECK AREA WHILE UNDERWAY UNTIL RAILING IS REPAIRED.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Construction/Loadline
Issued 31 March 1995
Resolved
ATTACH CHAIN OR KEEPER DEVICE FOR LAZARETTE HATCH OPENING.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Fire Fighting
Issued 31 March 1995
Resolved
PROVIDE ADEQUATE HOSE FOR HAND FIRE PUMP TO FIGHT FIRE ANYWHERE ON VESSEL.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Documentation
Issued 31 March 1995
Resolved
PROVIDE DOCUMENTATION OF DRUG TESTING PROGRAM ONBOARD VESSEL.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Engineering
Issued 31 March 1995
Resolved
PROVIDE 1" LETTER SIGNS MARKING EACH EMERGENCY FUEL CUT-OFF VALVE INDICATING OPEN AND CLOSED POSITIONS.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Lifesaving
Issued 31 March 1995
Resolved
REPLACE WEAK LINKS ON BOTH BUOYANCY APPARATUS PAINTERS.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Lifesaving
Issued 27 April 1993
Resolved
PROPERLY STOW ALL LIFE JACKETS SO THAT NUMBERS MARKED ON SEAT MATCH ACTUAL STOWAGE.
Condition: Unknown
Due 10 May 1993
Resolved 11 May 1993
Lifesaving
Issued 27 April 1993
Resolved
STENCIL THREE LIFE JACKETS WITH VESSEL'S NAME IN ACCORDANCE WITH 46 CFR 185.30-5(C).
Condition: Unknown
Due 10 May 1993
Resolved 11 May 1993
Navigation
Issued 2 May 1989
Resolved
PERMANENTLY REPAIR THE LEAKING HYDRAULIC RAM FOR THE VESSEL STEERING SYSTEM.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989
Resolved
DEMONSTRATE PROPER OPERATIONS OF THE MAIN ENGINE PILOT HOUSE CONTROLS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
PROVIDE SIX HAND HELD ORANGE SMOKE FLARES
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
REPLACE THE WATER LIGHT BATTERIES FOR THE RING LIFE BUOYS AND THE AND THE BUOYANT APPARATUS. FOUR TOTAL.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
PATCH AND PROPERLY STENCIL THE BUOYANT APPARATUS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Documentation
Issued 23 June 1988
Resolved
PROVIDE PROOF OF VALID FCC CERTIFICATE TO THIS OFFICE, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988