Documentation record
Registered dimensions (L × B × D)52.0 ft × 16.5 ft × 8.1 ft
Registered tonnagegross 48 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT TOWNSEND, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 22
17 February 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299449
4 November 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8264313
5 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8076012
5 March 2024
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868464
12 December 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7838268
14 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7638413
4 January 2023
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7616574
16 March 2022
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412738
10 November 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7349979
24 July 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7267065
24 July 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7269325
29 April 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7185973
2 March 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7149153
4 March 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6920120
3 December 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6865502
21 February 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6630123
5 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6366475
24 January 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6342545
2 March 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6093025
22 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6046014
15 September 2016
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6005071
9 March 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5973463
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 5 March 2025
Resolved
Electrical cable penetrating an enclosure is to be secured against strain. wiring in seat boxes are not secured against strain at the enclosures. Properly secure cable at the enclosures. 46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Verified correction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. O/o is to ensure drills are conducted at a minimum of three month intervals and that adequate details of the trainings are recorded.
Action required: 10 - Deficiency Rectified
Due 5 March 2025
Resolved 5 March 2025
Resolution: O/O provided log book for future use.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2025
Resolved
Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. O/o was unable to present logs proving the tests were being conducted or recorded. O/o is to start conducting and recording tests as required.
Action required: 10 - Deficiency Rectified
Due 5 March 2025
Resolved 5 March 2025
Resolution: O/O provided log books for future use.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 March 2024
Resolved
47CFR 80.903: Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Communications Act Radiotelephony Certificates may be obtained from the Commission's National Call Center—(888) 225–5322—or from its forms contractor.
FCC Radio Telephony Certificate was expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 March 2024
Resolved
46CFR 185.304(a)(8): The movement of vessel shall be under the direction and control of the master or a licensed mate at all times. The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to prevent a casualty. Special attention should be paid to: Magnetic variation and deviation errors of the compass.
Magnetic compass deviation chart was last updated in 1991. Observed physical and digital magnetic compass displaying different directions with a ten degree deviation.
Deviation table is no longer valid. Provide updated deviation table.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 15 March 2024
Resolution: Observed updated deviation table onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 March 2024
Resolved
46CFR 183.430: Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
VSL O/O was unable to locate two portable lights to be utilized near operating station and machinery space.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 15 March 2024
Resolution: Two portable lights provided.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 March 2024
Resolved
46CFR 179.360(b)(2): A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Aft. Freeman Hatch was not secured to the deck with any means.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 5 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2020
Resolved
The required ring buoy water light was inoperable, not meeting the requirements of subchapter Q. Provide an approved floating water light.
46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo sent providing an approved water light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 March 2020
Resolved
The required lifeline attached to the ring buoy must be dark in color and have a breaking strength of 1,124 pounds. Replace with a line meeting the requirements.
46CFR180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo sent documenting a new lifeline.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 March 2020
Resolved
Vessel over 26' must have an oil pollution placard. Provide a placard and mount in a location to be read by crew and passengers.
33CFR151.59(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo documentation of an oil placard sent.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020
Resolved
Fuel tank shut off valve markings on the port and starboard fuel tanks were broken up and difficult to read. Replace with appropriate sized markings.
46CFR185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 18 March 2020
Resolution: Photo documentation submitted of new fuel oil shut off valve markings.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 February 2019
Resolved
Provide a company corrective action plan to ensure compliance with records and logs. To-date, drill, training, and emergency equipment maintenance logs were not on board company vessels at the time of inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 25 March 2019
Resolution: POC provided evidence of maintenance and drill logs via email/photos
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2019
Resolved
Complete DAPI audit conducted by USCG
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2019
Resolved 11 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 February 2019
Resolved
Provide updated and corrected charts
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 25 March 2019
Resolution: POC provided photos of updated charts for vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 February 2019
Resolved
Provide means for measuring frequency for the A/C generator
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 15 March 2019
Resolution: POC sent photo of functioning HZ meter
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 March 2017
Resolved
Certificate of Documentation in pending status; no valid COD onboard. Vessel provide valid COD.
Condition: Invalid
Due 2 April 2017
Resolved 7 March 2017
Construction/Loadline › Hull › Hull Plating
Issued 15 September 2016
Resolved
Complete credit Dry-Dock Exam (DDX) by 30NOV2016.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 22 November 2016
Resolution: Examined hull exterior. Hull is fair, no deflection noted. Hull coating intact. Both water lubricated shaft bearings were within tolerance. Propellers were off for routine maintenance. Rudders and rudder packing appeared in good condition.
Examined