GENESIS

Built
1979
Last inspected
21 July 2025
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 July 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8647074
WDP3890
Flag
UNITED STATES
Maury page id
psix-50138

Documentation record

Registered dimensions (L × B × D)110.5 ft × 23.2 ft × 9.9 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)110.5 ft × 23.2 ft × 9.9 ft
ITC tonnagegross 155 / net 46
BuilderPROGRESSIVE SHIPBUILDERS & FABRICATORS INC · HOUMA, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCORPUS CHRISTI, TX
Endorsements, as the file codes themcw_un, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it155 - Convention (Subpart B), Gross Ton
92 - Regulatory (Subpart C or D), Gross Ton
46 - Convention (Subpart B), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 113 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

EMIL KURTZ Industrial Vessel · MISLE 83813 · 9 July 2025 · activity 8204559

Inspection history · 24

21 July 2025 Damage Survey · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8191201
9 July 2025 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8204559
6 June 2025 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8153524
2 January 2025 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8057097
27 December 2024 In-Service Inspection · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8051310
21 September 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8015999
15 September 2024 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8002867
21 January 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8009373
17 November 2023 Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7825531
31 August 2023 Administrative Inspection · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7782080
4 October 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7568220
5 January 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7375854
4 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7345354
16 December 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7107946
7 January 2020 Annual Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6884607
17 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6814022
13 December 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6591746
28 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6363422
12 December 2017 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6323037
13 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6306222
28 September 2017 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6277335
5 April 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6118591
24 January 2017 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6076403
4 January 2017 Examination of Repairs · Administrative Inspection · Damage Survey · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6059028

Deficiency record · 113

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel reported 03 inoperable main engines after striking an unknown object in the ship channel. Repair or replace prior to the carriage of passengers/cargo. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2025
Resolution: Vessel is being totaled due to cost of repairs and placed in inactive status.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 January 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline, such as a lazarette, A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Vessel's high level switch raised to a level that allows a significant amount of water to gather in every bilge space without alarm at the operating station. Lower bilge high level switch to the satisfaction of the attending USCG Marine Inspector (MI). 46 CFR 182.530
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 23 January 2025
Resolution: Vessel lowered bilge high level switch to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 January 2025 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Vessel does not have any strainers on bilge suction lines. Install strainers to the satisfaction of USCG MI. 46 CFR 182.25-5 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 23 January 2025
Resolution: Vessel installed strainers on all bilge suction piping.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 January 2025 Resolved
In addition to meeting § 180.130, each life float and buoyant apparatus must be stowed as required under this section, the float-free link required by § 180.130(a)(1) must be:(1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant; Vessel's float-free link missing identification tag certifying that it meets required standard. Replace float-free link to the satisfaction of the attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 23 January 2025
Resolution: Vessel installed new float free link.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 January 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel's floating waterlight had only 1 of 3 clips on the top of the light that were operable. Replace floating waterlight to the satisfaction of the attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 23 January 2025
Resolution: Vessel installed new floating waterlight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2025 Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Vessel did not have any way to conduct alcohol testing available. Order alcohol testing equipment for the vessel to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 23 January 2025
Resolution: Vessel received new alcohol testing strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 October 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. After completing sea trials and returning to the mooring area, vessel lost power. The vessel was on the #1 generator and then switched to the #2 generator to regain power to necessary services. Identify cause of power failure and repair or replace to the satisfaction of the attending Marine Inspector. **Vessel is restricted as follows: Prior to carrying Passengers and conducting commercial operations. - 46 CFR 183.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2024
Resolution: Vessel replaced fuel filter and refueled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 September 2024 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Vessel's overboard sewage discharge valve is not fully secured nor fully closed. Sewage was slowly discharging on the side shell/skin of the vessel. The means of securing the valve is via flexible wire which still allowed the valve handle to turn. Repair or replace to the satisfaction of the attending USCG Marine Inspector 33 CFR 159.7(c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 October 2024
Resolution: Vessel repaied valve and locked to prevent unintentional discharge.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 September 2024 Resolved
No major repairs or altercations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Vessel was repairing the motor on the main diesel engine without making any notifications to the Coast Guard on the repair. Vessel will also need to conduct a sea trial. Repair to the satisfaction of the attending Coast Guard Marine Inspector. 46 CFR 176.20-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 October 2024
Resolution: Repairs were satisfactory completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 September 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following test and inspections of the hull structure and its appurtenances: Examine all accessible parts of the exterior and interior of the hull. Vessel had multiple cracked welds on both the port and starboard railings around the parameter of the vessel and was missing railing on port and starboard stairs. Repair to the satisfaction of the attending Coast Guard Marine Inspector. 46 CFR 176.25-5(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 October 2024
Resolution: Sections of damaged or missing railing have been repaired and/or replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 21 September 2023 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Port and Starboard Engine room ventilation covers do not properly seal when installed. Correct ventilation covers to fit snugly and properly seal engine room to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-50(a)Repair at Drydock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 January 2024
Resolution: Corrected vetilation dampers notched out bolt holes and installed wingnuts to hold shut.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 September 2023 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. #4 MDE has accumulation of fuel oil in the flame impingement bowl. Remove fuel oil and repair leak causing fuel oil to accumulate to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 10 October 2023
Resolution: Oil cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 September 2023 Resolved
A vessel on an oceans route must carry six hand red flare distress signals and six hand orange smoke distress signals. Substitutions are allowed per 46 CFR 180.68(c). The 12 combination flares carried on board were 5 months expired. Replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 September 2023
Resolution: Vessel POC provided photographs of newly purchased flares.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 September 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel’s First Aid kit was incomplete and contained expired products. Replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 September 2023
Resolution: Vessel POC provided photographs of newly purchased first aid kits.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 September 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2023
Resolved 18 January 2024
Resolution: Recieved new charts
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 September 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. Vessel did not have a record of Abandon Ship and man overboard drills and training in any vessel log.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 6 November 2023
Resolution: Witnessed satisfactory Man Overboard and Fire Drills. All Drills Logged in Logbook.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 September 2023 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. Vessel did not have record of Firefighting drills and training in any vessel log.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 6 November 2023
Resolution: Witnessed satisfactory Man Overboard and Fire Drills. All Drills Logged in Logbook.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 September 2023 Resolved
The master of the vessel shall ensure that: The EPIRB required by 180.40-1 of this subchapter is tested monthly. The vessel has no recent records of EPIRB testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: Verified logs
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 September 2023 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Excessive oil in engine room, multiple leaks from main engines and standing oil in bilges. Clean oil from bilges and machinery and repair leaks to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: Bilges were cleaned and leaks rectified.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 September 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following test and inspections of the hull structure and its appurtenances: Examine all accessible parts of the exterior and interior of the hull. Starboard midship railing has a cracked weld on the top and a broken weld on the course. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-5(a)(1) Repair at drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 December 2023
Resolution: All Rails have been welded and are structurally sound.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 5 September 2023 Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessels hailing port on the stern board does not match the hailing port listed on the Certificate of Documentation. Correct the hailing port to read “Corpus Christi, TX” to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 21 September 2023
Resolution: Repainted stern board to read correctly.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 September 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing strips were expired, replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: verified test strips
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 September 2023 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Both watertight doors leading into the engine room have compromised seals. Replace seals to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-50(a) Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 January 2024
Resolution: seals replaced
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 September 2023 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel had 12 life jackets that were not marked with the vessels name. Correct to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: Jackets Marked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023 Resolved
Electrical enclosures shall be constructed so uninsulated parts cannot be inadvertently touched. The electrical panel mounted on the Starboard side forward bulkhead of the engine room was open and did not have the front panel attached. The electrical panel in the passenger accommodation space was missing blank fillers that would allow accidental contact to live electrical circuits. Replace the front panel and fill in the blank spaces of the electrical enclosures to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: Blank filled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. The main cable coming out of the port side generator has compromised armor and possibly compromised sheathing from rubbing on the generator mount due to insufficient mounting and lack of chaffing gear. Repair or replace cable and mount properly as to not cause future failure due to chaffing on frame to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-20(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: repaired, chaffing gear installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Wiring inside the electrical enclosure mounted on the Starboard side forward bulkhead of the engine room has compromised insulation that could cause an electrical arc between wires. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-20(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: panel repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023 Resolved
Electrical installations on vessels shall be such that services essential for safety will be maintained under various emergency conditions and the safety of passengers, crew and vessel from electrical hazards will be assured. Vessel’s electrical system has many loose and or exposed wires in the engine room, air conditioning space and in the crew’s mess that could cause electrocution or arcing of wires. Crew’s mess also contains a live light fixture with no bulbs or cover. Repair or replace wiring to the satisfaction of the attending Marine Inspector. 46 CFR 111.05-15(a)Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 December 2023
Resolution: Above corrected, junction boxes have been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 September 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall examine and test items to the extent necessary to determine that they are in proper operating condition and fit for the service in which they are intended. The oil pressure gauges on both generators are illegible and the oil pressure gauge above the starboard generator is leaking oil onto the generator. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: replaced
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 September 2023 Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. Lagging on all four main engines as well as the generators is severely degraded, missing or separated. Repair or replace to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-10(b)Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 December 2023
Resolution: degraded lagging has been replaced, vessel is planning on an re-power next year and will replace all lagging during that time.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 September 2023 Resolved
A cooking appliance must be installed to prevent movement in heavy seas. Sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Sea rails on stove were partially installed and microwave was not secure as to prevent movement in heavy seas. Install sea rails on stove and secure microwave to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 21 September 2023
Resolution: Sea rails installed and microwave secured.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 September 2023 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: Each hatch on a watertight trunk that extends at least 12” above the weather deck. Weathertight hatch on stern of accommodation has degraded seals and has a notch cut into the bottom knife edge to allow an extension cord to transit rendering the hatch non-weathertight. Repair to the satisfaction of the attending Marine Inspector.Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 December 2023
Resolution: Door knife edge has been repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall examine and test items to the extent necessary to determine that they are in proper operating condition and fit for the service in which they are intended. Water heater tank reservoir bracket has cracked / broken weld. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-10(a)Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 December 2023
Resolution: Bracket weld repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023 Resolved
Electrical installations on vessels shall be such that services essential for safety will be maintained under various emergency conditions and the safety of passengers, crew and vessel from electrical hazards will be assured. Outlet in lower deck head and two outlets in engine room had missing / loose covers and loose electrical boxes. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 111.05-15(a)Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 December 2023
Resolution: Outlets were secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023 Resolved
Switchboards shall be fitted with driphoods and non-conducting handrails. Vessels main distribution panel switchboard is missing the non-conducting handrail. Replace to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-15(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 10 October 2023
Resolution: Handrail replaced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 September 2023 Resolved
An interconnected detection and alarm system must:(1)Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217; (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. (b) A fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76 would satisfy the requirements of this section. Vessel does not have an interconnected detection and alarm system. Provide plans for approval for the proposed system prior to installation. Installation must be verified onboard the vessel by the attending Marine Inspector.Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 January 2024
Resolution: Installed interconnected system, tested system, functioned correctly.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 September 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel currently has a <200nm route and does not have the proper installation of radios for the route. Vessel is missing a MF-DSC or SSB-DSC radio or approved Ship Earth Station (SES) with reserve source of power for 3 hours, and NAVTEX. Install required radio equipment and have station re-certified by FCC inspector to the satisfaction of the attending Marine Inspector. Vessel is restricted to <100nm route until installation is complete.Repair at Drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 January 2024
Resolution: Reduced COI to less than 100nm.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 5 September 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 10 October 2023
Resolution: Captain recieved med card
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 September 2023 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. The step on the inside of the weathertight door leading into the accommodation space is broken and has a temporary wooden board installed. Repair or replace to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-50(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 21 September 2023
Resolution: New step installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 September 2023 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Alarm panel in operating station does not have labels indicating which alarms are going off. Label panel to indicate which alarms are which to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-50(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 10 October 2023
Resolution: Alarms labled
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2022 Resolved
Each EPIRB must be tested monthly to determine that it is operative and shall be logged or otherwise documented, as applicable. Vessel had no record of EPIRB testing logged. 46 CFR 185.728(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2022
Resolution: Vessel created new EPIRB monthly log sheet and started to log EPIRB testing.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 4 October 2022 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. Vessel had inoperable waterlight. 46 CFR 180.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2022
Resolution: Vessel purchased new waterlight battery.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 October 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel did not have up-to-date charts nor means of correcting charts. 46 CFR 184.420(a)(1)
Action required: 10 - Deficiency Rectified
Resolved 10 October 2022
Resolution: Vessel purchased new up-to-date chart and chart correction kit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 January 2022 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date charts. The vessels charts were printed in 2019 and did not contain any chart corrections. Vessel shall ensure charts are kept corrected/reviewed for corrections upon LNM release, for intended area(s) of operation within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 18 January 2022
Resolution: Received satisfactory objective evidence of new charts on board vessel. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 January 2022 Resolved
The bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of parts II & III of Title III of the Communications Act… Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. The vessels FCC Safety Radio certificate expired in 2021. Vessel shall renew their FCC Safety Radio certificate within 14 days. 47 CFR 80.1005
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 5 January 2022
Resolution: Received satisfactory objective evidence of valid FCC Safety Radio certificate on board vessel. All sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 December 2020 Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas. The second means of escape in the passenger seating area has seized dogs and was unable to be opened by the crew for at least 8 minutes. Lubricate and/or repair to the satisfaction of the attending CG Marine Inspector. 46 CFR 177.15-1(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2020
Resolution: Vessel crew was able to conduct maintenance on the hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2020 Resolved
Cables entering boxes or fittings shall conform with the following requirements: openings through which conductors enter shall be adequately closed. The outlet box for the clothes dryer located next to the exhaust has an opening in the side and is covered in lint dust creating a hazardous fire condition. Close and/or repair to the satisfaction of the attending CG Marine Inspector. 46 CFR 183.10-20(f)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2020
Resolution: The electrical outlet was relocated to a safer location and the area cleaned of debris (lint)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 December 2020 Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must: be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. The starboard side bridge wing ring life buoy has deteriotating line. The line must be replaced with a suitable lifeline to the satisfaction of the attending CG Marine Inspector. 46 CFR 180.70(c)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Line was replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 December 2020 Resolved
The discharge ends of the diesel fuel tank vent pipes shall be fitted with removable flame screens. The port side diesel fuel tank vent flame screen is severely wasted around the edges where flammable vapors can pass around the remaining flame screen. Repair to the satisfaction of the attending CG Marine Inspector. 46 CFR 182.20-35(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Flame screen is in place.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2020 Resolved
Fire hose if 1.5 inches in diameter is used after Janauary 1, 1980 each length of hose must be lined commercial fire hose that conforms to UL Stnadard 19 or Federal Spectification ZZ-H-451E. The port side aft fire hose is worn through the top and secondary layers of the hose. Replace the hose to the satisfaction of the attending CG Marine Inspector. 46 CFR 181.15-10(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: New fire hose is in place and tested.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 December 2020 Resolved
All supply ducts for ventilation purposes shall be provided with cowls or scoops. The crew could not unsecure the scoop from the bulkhead for 10 minutes in order to demonstrate closure of the portside ventilation duct of the engine room. Modify the storage location of the ventilation scoop to the satisfaciton of the attending CG Marine Inspector. 46 CFR 182.20-45(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Scoop was made readily available
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 December 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. The stern light has a blown bulb and did not work. The crew replaced the bulb and the light tested satisfactorily to the attending CG Marine Inspector. 46 CFR 183.420
Action required: 10 - Deficiency Rectified
Resolved 16 December 2020
Resolution: rectified on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 December 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One of the lifejackets had a hole in it exposing the inside buoyant material. The crew destroyed the damaged lifejacket and replaced it with an extra one they had one hand to the satisfaction of the attending CG Marine Inspector. 46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 16 December 2020
Resolution: Rectified on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 December 2020 Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard or rail. The two inboard main engine shafts were not suitably protected or covered. Provide appropriate protection from this rotating machinery. 46 CFR 177.960
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2020
Resolution: Vessel crew was able to obtain and secure proper protective covers over both shafts.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 December 2020 Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard or rail. The starboard ship service generator windings cover was partially open. Provide adequate cover to protect the crew from this hazard. 46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Appropriate cover was in place and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) protect passenger, crew other persons and the vessel from electrical hazards including fire caused by or originating in electrical equipment and electrical shock. A fixed overhead light in the engine room was spliced into an extension cord which was plugged into an outlet. The overhead light shall be properly hard wired into the vessels existing lighting system. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Light was properly tied into existing electrical system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2020 Resolved
Openings through which conductors enter shall be adequately closed. Two conductors entering a junction box located forward of the starboard inboard main engine were not suitably closed. Properly close the two entry points with the existing plugs. 46 CFR 183.10-20(f)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Box was appropriately plugged.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 December 2020 Resolved
Each generator shall be protected with an overcurrent device set at a value not exceeding 15 percent above the full load rating. The starboard ship service generator overcurrent protection could not be suitably tested. Prover proper operation of the the overcurrent protection. 46 CFR 183.10-35(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Crew demonstrated proper overspeed trip.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 December 2020 Resolved
Auxiliary machinery of the internal combustion type shall comply with the provision of this part. 46 CFR 182.20-5(b) requires gauges to indicate water cooling discharge temperature shall be provided. The port generator jacket water temperature gauge was unreadable due to moisture behind the glass. Gauge must be replaced. 46 CFR 182.10-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: New gauge was installed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 16 December 2020 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. An overhead light protective cover located in a crew accommodation was severely shattered leaving sharp edges and exposed bulbs creating an unsafe condition for those berthing in the space. Provide adequate protection for the light fixture that does not create an unsafe condition. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: New light cover was in place.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 December 2020 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Marine inspector found in a crew bunk room that two surge protectors were "daisy chained" creating an unsafe condition. Ensure electrical cords and surge protectors are properly used. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 16 December 2020
Resolution: Additional surge protectors were disconnected from each other and the crew was educated on the hazards associated with daisy chaining electrical cords.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2020 Resolved
All wiring and cable shall be suitable for marine service and for the particular installation used. An electrical through hole penetration on the starboard side bridge is open and not closed for a weathertight condition. Repair to the satisfaction of the attending CG Marine Inspector. 46 CFR 183.10.20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 28 December 2020
Resolution: Penetration properly sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2020 Resolved
Wiring joints and splices shall be mechanically secured and made in junction boxes. Electrical wires were not properly spliced and terminated in the AC Compartment. Repair to the satisfaction of the attending CG Marine Inspector. 46 CFR 183.05-50(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 29 December 2020
Resolution: Wires were ended in a junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2020 Resolved
Each life jacket carried on a vessel on oceans and coastwise must have a Coast Guard approved life jacket light. 17 of the 60 required life jacket lights are not working or working intermittently. Attach Coast Guard approved lights to the life jackets to the satisfaction of the attending Coast Guard Marine Inspector. Vessel is limited to 43 total persons on board until deficiency is cleared by attending Coast Guard Marine Inspector. 46CFR180.75(a) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Vessel provided new lights.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 13 January 2020 Resolved
At a minimum, each garbage placard must notify the reader of the operating requirements contained in 33 CFR 151.67 through 151.73 as they apply to the ship. The garbage placards on board the vessel are not-up-to-date to the current regulations. Post current garbage placards in prominent locations and in sufficient number to the satisfaction of the attending Coast Guard Marine Inspector. 33CFR151.59(c) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: New garbage placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 January 2020 Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b). Vessels first aid kit was not complete several items were expired. Ensure all the items required by the table are onboard and current. 46CFR160.041-4(b) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: New meds onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 January 2020 Resolved
Instructions for the use of the contents of the first-aid kit shall be printed in legible type on a durable surface and shall be securely attached to the inside of the cover. Ensure the instructions are installed. 46CFR160.041-4(c) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: First aid book in cabinet
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 January 2020 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel hydrostatic release was not marked with the expiration date. Install new hydrostatic release marked with expiration date and proof of purchase. 46CFR180.64 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: New hydrostatic release installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 January 2020 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the OCMI. Vessel has 2 portable fire extinguishers that were not installed in brackets, outside the engine room and next to washer and dryers. Mount brackets and install fire extinguishers. 46CFR181.30-10(b) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Fire extinguishers are hard mounted.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 13 January 2020 Resolved
At each re-inspection and at every other inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Vessels washer, dryer, and stove not securely mounted. Mount appliances securely to deck or bulkhead to prevent shifting during list and heel. 46CFR176.25-50(a) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Appliances are mounted to prevent shifting.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 January 2020 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other inspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. The lubricating oil from the pneumatic control is being sprayed onto the electrical wires and connections inside the operating station. Reposition the air vent so the oil mist does not cause a fire hazard. 46CFR176.25-50(b) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Cleaned up oil. Remove inline oiler from air controls
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. The following unsatisfactory high voltage electrical hazards were observed: lower passenger compartment stbd side 110v outlet box unsecured, crew quarters passageway 110v outlet box cracked, main vessel entrance outside 110v outlet box broken with silicone holding wires, emergency fuel pump shut off switch box broken with exposed wires, galley port breaker box missing mounting hardware and unsecured. Repair electrical components to the satisfaction of Marine Inspector. - 46CFR183.01-15(a) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: All electrical issues rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found the following low voltage electrical hazards: wiring under the pilothouse console has wire nuts, uninsulated connections, bare wires, oil covered wires, connections should be made on terminal strips, dead-end and unused connections. Remove all unused wires, clean off all oil, make all electrical connections on terminal strips, remove all wire nuts to the satisfaction of Marine Inspector. - 46CFR183.01-15(a) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: All electrical issues rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2020 Resolved
Acid batteries shall be located in a tray of lead or other suitable material resistant to deteriorating action by electrolyte. Battery under pilot house console is in metal tray with no insulating material between battery and metal. Battery has corroded connections. Insulate battery tray. Make connections on terminal strip. 46CFR183.05-20(d) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: All electrical issues rectified.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 13 January 2020 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel Captain could not provide evidence of an inspection of the radiotelephone installation within the last five years. Provide evidence of a valid radiotelephone installation inspection to the satisfaction of the attending Coast Guard Marine Inspector. 47CFR80.903 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Bridge to Bridge telephony cert issued by FCC
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 January 2020 Resolved
Vessels operating beyond 100NM from shore must be equipped with a single sideband radiotelephone meeting the requirements of 47 CFR 80.1101(c)(4). Vessels SSB radio could not be proven operational. Prove proper operation of vessels SSB radio prior to transiting beyond 100 NM from shore. 47CFR80.905(a)(3) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: SSB radio replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2020 Resolved
The bilge pipe may be fitted with a screw-down valve without a reach rod on the aft side of the collision bulkhead if it is readily accessible under service conditions. The reach rod for the screw-down valve is not connected, preventing it from being opened or closed. The valve is also not accessible during service conditions. Prove proper operation of the forepeak reach rod valve connection to the satisfaction of the attending Coast Guard Marine Inspector. 46CFR182.25-5(d) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 28 January 2020
Resolution: Reach rod re-attached and operable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 January 2020 Resolved
To maintain a valid COI, you must complete your annual inspection within the period specified in 176.500(b)(1) and your COI must be endorsed. The vessel's annual inspection is past due and the vessel is not ready for CG inspection. Contact cognizant OCMI to schedule inspection when ready.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2020
Resolved 22 January 2020
Resolution: CONDUCTED ANNUAL INSPECTION
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 December 2018 Resolved
No life saving maintenance record or logs could be provided. Establish method for documenting life saving equipment maintenance and have available to CG marine inspector upon request. 46 CFR 185.702
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 December 2018 Resolved
Provide appropriate weak links for lifefloats. Currently 2 floats have the wrong size link and the third has not tag to identify it’s size. The 6 person float also needs to be attached to a week link. 46 CFR 180.137(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 8 January 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 December 2018 Resolved
Provide and prove proper operation of a public address system that is useable from the operating station. Vessel currently has an inoperable PA system that only works at the external aft facing operating station. 46 CFR 184.610(b) & (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 8 January 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 December 2018 Resolved
Provide appropriate first aid kit. First aid kit currently on board does not contain required contents. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 8 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 December 2018 Resolved
Stow distress signals in an appropriate waterproof container and mark distress signals. Current container is a plastic nonsealing container. 46 CFR 180.68(e) & 185.614
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 8 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 December 2018 Resolved
Prove proper operation of ship board fixed fire pump pressure to 60 psi. Currently the fire pump only reaches 50 psi. 46 CFR 181.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 December 2018 Resolved
Provide light guards over lights in overhead of engine room. 46 CFR 183.10-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 December 2018 Resolved
Prove proper installation of starboard main engine oil pressure gauge. Current installation has it hanging on wires. 46 CFR 54.15.5(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 December 2018 Resolved
Prove proper operation of watertight door indicators located on the bridge. Current indicators are not visible. 46 CFR 185
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 December 2018 Resolved
Engine room watertight door closing mechanism shall be put back to original equipment. Currently one dog is held with a handmade clip. 46 CFR 185
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 December 2018 Resolved
Prove air receivers relief valve are of appropriate set point and replace broken gauge on port air receiver. Relief valve set points are not visible and the gauge is broken. 46 CFR 54.15-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 December 2018 Resolved
Repair or replace emergency light in engine room. Light facing escape ladder is not operating. 46 CFR 184.30-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 December 2018 Resolved
Ensure all empty breaker spaces in panels located in engine room are properly blanked. There are currently open breaker spaces exposing people to live electrical equipment when panel door is open. 46 CFR 183.10-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 8 January 2019
Engineering › Compressed Air System (start air) › Valve
Issued 6 October 2017 Resolved
Cross connect valve between port and starboard air compressors siezed and unable to close
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Cross connect valve was replaced.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 6 October 2017 Resolved
Both the interior and exterior of the starboard air receiver wascorroded to the point that inspector was unable to visually verify the integrity of the pressure vessel, required hydrostatic testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Air reciever was replaced with new.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 October 2017 Resolved
GPS not hooked up to VHF radio rendering DSC inoperable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: GPS and radio connected
Engineering › Bilge Water Management System › Piping
Issued 6 October 2017 Resolved
Installed bilge manifold valves not clearly marked and no line diagram or instructions for operation posted at the manifold.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Manifold marked and diagram created
Construction/Loadline › Hull › Weld
Issued 28 September 2017 Resolved
Engine bed mount on #3 MDE weld cracked.
Condition: Damaged By Earlier Event
Due 1 December 2017
Resolved 12 December 2017
Resolution: engine mount rewelded
Construction/Loadline › Structures › Deck Plating
Issued 24 January 2017 Resolved
Vsl cargo deck was holed. Make permanent repairs to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 9 February 2017
Resolution: MI witnessed satisfactory inserts to the damaged cargo deck. See narrative for details.
Construction/Loadline › Hull › Girder
Issued 23 January 2017 Resolved
Significant crack to fore/aft girder used to mount the port main diesel engine exhaust. Permanent repair to be made.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2017
Resolved 9 February 2017
Resolution: final repairs completed
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2017 Resolved
Multiple soft spots in deck plating observed with a complete penetration on the starboard side amidships. Port aft soft patch for engine replacement/repair has cracked weld on the entire aft side. Port forward soft patch (bolted) leaks water through the hatch, which is rotting bolts keeping the hatch down. Permanent repairs to be made to ensure the watertight integrity of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2017
Resolved 9 February 2017
Resolution: Final repairs completed. See narrative for details.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 January 2017 Resolved
Guards for inboard shafts missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2017
Resolved 5 January 2017
Resolution: Vessel crew constructed and welded guards to prevent personnel from being exposed to spinning shafts.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 January 2017 Resolved
multiple flexible hose sections of wet exhaust piping not double clamped.
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 5 January 2017
Resolution: All sections double clamped.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 January 2017 Resolved
Captain stated that crewmembers onboard were new and were not able to perform a man overboard drill.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2017
Resolved 5 January 2017
Resolution: Vessel conducted successful man overboard drill.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 January 2017 Resolved
Nearly all lights attached to lifejackets flicker and turn off upon movement.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2017
Resolved 5 January 2017
Resolution: Vessel provided new lights for inoperable ones.
Lifesaving › Rocket Parachute Flares › General
Issued 4 January 2017 Resolved
Vessel only had 8 of the required 12 flares.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 5 January 2017
Resolution: Vessel purchased remaining 4 flares
Communications › Audible Communications › Horn/Whistle
Issued 4 January 2017 Resolved
Air line for the vessel's horn had parted making the horn inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2017
Resolved 5 January 2017
Resolution: Vessel replaced air line and horn.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 January 2017 Resolved
Stern lighting fixture loose and causing the light to be intermittent. Vessel restricted to daytime operations.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 5 January 2017
Resolution: Vessel repaired fixture and replaced bulb.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 January 2017 Resolved
Vessel failed to post EAP hotline throughout vessel.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 5 January 2017
Resolution: Vessel posted hotline in multiple locations.
Engineering › Compressed Air System (start air) › Valve
Issued 4 January 2017 Resolved
Pressure relief valve markings were indecipherable.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 19 January 2017
Resolution: Valves replaced.
Electrical › Electric Supply System (service) › Battery Charger
Issued 4 January 2017 Resolved
Battery Charger in engineroom was not mounted securely to the vessel and the charger was not of the approved variety.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 6 April 2017
Resolution: Verified proper installation of marine battery charger.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 4 January 2017 Resolved
Sewage piping at the connection to the holding tank was leaking.
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 19 January 2017
Resolution: Piping leading to sewage tank permanently repaired.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 4 January 2017 Resolved
Fuel vent on the port side was missing a flame screen.
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 19 January 2017
Resolution: Fuel vent screen replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2017 Resolved
Port aft main deck rail bracken broken.
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 19 January 2017
Resolution: Deck rail repaired.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 4 January 2017 Resolved
03 cracked welds on the cross tie for the ribs in the forepeak.
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 19 January 2017
Resolution: Welds repaired.

Recorded names · 1

CIMARRON RIVER (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.