MAURY USCG vessel records
← All vessels

TITUS

Built
1979
Last inspected
19 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCV9471
Flag
UNITED STATES
Maury page id
psix-50150

Documentation record

Registered dimensions (L × B × D)104.9 ft × 24.0 ft × 7.3 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 21 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

19 February 2026 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8305359
12 January 2026 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8303339
3 July 2025 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8153159
8 November 2024 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8032463
30 January 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7843099
2 June 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7676729
21 February 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7636719
23 November 2021 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7342143
1 March 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7128142
6 July 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6971520
26 November 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6851296
27 November 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6587805
6 November 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6581007
1 June 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6419561
2 February 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6348672
1 December 2016 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6050552
20 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5945164
10 May 2016 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5878909

Deficiency record · 51

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2024 Resolved
3 separate cracks were identified on the starboard rudder post supports. Make satisfactory repairs to the cracks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 11 December 2024
Resolution: Received email with pictures illustrating the the starboard rudder post supports have been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 December 2024 Resolved
Leaks were observed of the bilge/fire main piping near the fire pump. Repair identified leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 7 January 2025
Resolution: The pump was removed, cleaned, primed and a new seal kit was installed. Received, reviewed and accepted video showing pump fully operational and not leaking. All cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 January 2024 Resolved
At each initial and subsequent inspection for certification the Marine Inspection shall exam and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition and fit for the service in which they are intented; (6) fire protective devices. electrical apparatus which operates in conjunction with the fire protective device installed on-board the vessel shall be tested by operation the test shall be applied in the same manner as the manner intended to simulate the actual operation in case of fire. Found a trouble fault at the fire detection panel. Provide tech report attesting to the proper repair of fault in the fire detection panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 7 February 2024
Resolution: Received technician report attesting to the repairs of the fire detection system
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2024 Resolved
For each 79,500 L (21,000 U.S. gallons) or part thereof of any Class 3 (flammable) or combustible liquid being transported on board a vessel in a portable tank here must be provided at least one B-V semiportable foam (152 L/40 gallon capacity) (see 46 CFR 95.50), dry chemical (45.4 kg (100 pounds) minimum capacity) or equivalent fire extinguisher, or a fire hose fitted with an approved portable mechanical foam nozzle with pick-up tube and two 19 L (5 gallon) cans of foam liquid concentrate. MI witnessed could not identify the lot or expiration numbers on the cans. Cans were also deteriorated and cracked. Replace cans of foam liquid prior to the carriage of any Portable tanks containing flammable or combustible cargo.
Action required: 705 - Other - as specified
Due 30 January 2024
Resolved 13 February 2024
Resolution: Replaced the foam with new unexpired cans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 January 2024 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. MI found loose foundation and mounting hardware on the STBD Generator prime mover. Tighten the hardware to specification to avoid machinery from shifting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 13 February 2024
Resolution: Replaced and tighened mounting hardware.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2024 Resolved
The cable shall be examined as far as practicable without undue disturbance of the cable or electrical apparatus. MI identified Multiple open wires in the engine room. Make proper connections to the satisfaction of the MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 13 February 2024
Resolution: Open wires were removed from the harness.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 January 2024 Resolved
Vertical exhaust piping must be water jacketed or suitable insulated between the engine manifold and the spark arrester. Found portion of exhaust piping with missing insulation on the PORT engine. Replace missing insulation on exhaust pipping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 13 February 2024
Resolution: Placed lagging on the exhaust lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2023 Resolved
Numerous life-jacket lights were not working properly and retro-reflective tape was worn. Replace defective lights and apply new retro-tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2023
Resolution: Replaced retro tape and new lights.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 February 2023 Resolved
Rescue platform showed signs of a broken weld at the notch and tread. Permanently repair broken weld and secure chains to ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 February 2023 Resolved
Vessel's fire pump pressure gauge was not working and unable to verify pressure. Replace gauge Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2023
Resolution: Gauge was replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 February 2023 Resolved
Junction box missing in the engine room overhead and dead in wires were found. Install new junction box in overhead and remove non-working fixtures/dead end wires. Old T 46 CFR 183.10-20 (k)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2023
Resolution: Installed new junction box with cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023 Resolved
Numerous buckets of oil and fuel were in the engine room and a large amount of oil residue was noticed in the bilge. General clean-up of engine room and removal of oil/fuel residue from bilge and buckets. Old T 46 CFR 176.25-50 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2021 Resolved
Safety or relief valve discharges, when permitted to terminate in the machinery space, shall be led below the floorplates or to a remote position to minimize the hazardous effect of the escaping steam. Marine Inspector (MI) observed the hot water heater relief valve not piped in to bilge. Install piping to bilge to protect crew and equipment. Cite: 46 CFR 56.50-25 (c )
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Installed PVC pipe to end of SRV allowing discharge to be directed to below the deck plates in case of steam discharge.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 November 2021 Resolved
Vent pipes for diesel fuel tanks. (d) The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The Marine Inspector (MI) observed there were not flame screen on two (2) fuel oil vents. Install flame screens. Cite: 46 CFR 182.20-35 (d) [Old T]
Action required: 10 - Deficiency Rectified
Due 23 November 2021
Resolved 23 November 2021
Resolution: Crew installed flame screens.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 November 2021 Resolved
Penetrations and openings in watertight bulkheads in a vessel less than 100 gross tons must have a means to make them watertight. The MI observed the cable penetrating the bulkhead from the steering gear room to the machinery space is not of a watertight design. Install proper watertight design. Cite: 46 CFR 171.114 (a)(2) [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Bulkhead penetration was sealed to attain and maintain water tightness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 November 2021 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other then small buoyancy compartments, under all practical conditions. The MI observed the bilge suction piping in the steering gear room was not secured from free movement and the strainer positioned such that it is able to chafe the hull bottom plating. Secure pipes and strainer from movement and chafing. Cite: 46 CFR 182.25-1 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: U-bolts have been attached to the bilge piping system located in the steering compartment preventing the movement and chaffing of the bilge pipe and suction point.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2021 Resolved
Exhaust on air cooled engines need not be water cooled but suitable insulation may be required. MI observed the lagging on portside generator needs repairing. Cite: 46 CFR 182.20-15 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Insulation has been added to the portside SSDG's exhaust piping.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 November 2021 Resolved
Machinery shall be suitable in type and design for the purpose intended. MI observed oil an leak from portside generator. Repair leak. Cite: 46 CFR 182.10-1 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 10 December 2021
Resolution: Engine leak traced and cap off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2021 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspection. MI observed uninsulated wires, dead-end wires and wires in the bilge on main engines. Replace/repair wiring on main engines to ensure safe installation. Cite: 46 CFR 183.01-15 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 10 December 2021
Resolution: Dead-end wires and wires found in bilge have been properly supported out of bilge and secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2021 Resolved
Machinery shall be suitable in type and design for the purpose intended. The Marine Inspector observed a hydraulic leak in steering at main operating station. Cite: 46 CFR 182.10-1 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 10 December 2021
Resolution: Steering hydraulic unit fittings have been tightened and oil cleaned up. Leak stopped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2021 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspection. MI observed electrical panel in machinery space has mislabeled breaker. Cite: 46 CFR 183.01-15 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Electrical panel and breaker has been identified and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 November 2021 Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. MI Observed the paddles were not lashed. Secure paddles to the life floats. Cite: 46 CFR 180.175 (f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 10 December 2021
Resolution: Life float paddles have been secured to life float using twine.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 November 2021 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] observed the absence of markings for Emergency Egress leading from the galley and birthing spaces. Label emergency egresses. Cite: 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 10 December 2021
Resolution: EMERGENCY EXIT, KEEP CLEAR signage has been posted showing the escape route.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 November 2021 Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. The MI observed there is a temporary repair (soft patch) on the fire main piping located at the fire pump. Repair/Replace as original. Cite: 46 CFR 181.15-15 (c ) [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Damaged piping to the Fire pump was replaced new where soft patch was located. Additional sections of pipe stemming from the fire pump have also been renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2021 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspection. MI observed the washer and dryer need to be secured to prevent movement. Cite: 46 CFR 183.01-15 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Washer and dryer units have been strapped down to prevent movement.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 23 November 2021 Resolved
It shall be the duty of the master of any vessel subject to the regulations of this subchapter to prepare and post emergency checkoff lists. The MI observed the emergency Instructions need to be updated to include procedures for the deploying of the ladder/rescue platform combination by one person (minimum manning if master is at operating station). Update Emergency Instructions with current applicable procedures. Cite: 46 CFR 185.25-1 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 8 December 2021
Resolution: Crew emergency instructions have been updated to include use of the rescue platform and recovery procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 November 2021 Resolved
The light must be a floating water light approved under approval series 161.010 or other standard specified by the Commandant. MI observed the Life Float Battery was expired. Crew replaced battery. Cite: 46 CFR 180.175 (f)(4)
Action required: 10 - Deficiency Rectified
Due 23 November 2021
Resolved 23 November 2021
Resolution: Crew replaced battery.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 November 2021 Resolved
Vent pipes for diesel fuel tanks. (d) The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The MI observed there was not a flame screen on the fuel vent. Crew replaced the flame screen. Cite: 46 CFR 182.20-35 (d) [Old T]
Action required: 10 - Deficiency Rectified
Due 23 November 2021
Resolved 23 November 2021
Resolution: Crew replaced the flame screen.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 23 November 2021 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Master's Medical Certificate expired. Owner Rep. and Master are aware the Mariner will not be able to work in a position requiring a valid MMC/Medical certificate until mariner provides a valid medical certificate issued by the NMC. Cite: 46 CFR 10.301
Action required: 10 - Deficiency Rectified
Due 23 November 2021
Resolved 23 November 2021
Resolution: Owner Rep. and Master are aware the Mariner will not be able to work in a position requiring a valid MMC/Medical certificate until mariner provides a valid medical certificate issued by the NMC.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2021 Resolved
01 of 04 life floats are de-formed. Flotation is questioned. Replace, or prove proper flotation for 15 persons, to the satisfaction of the attending Marine Inspector. 46 CFR 180.10
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2021
Resolution: Received and reviewed photogtaphic evidence of replacement of the deformed bouyant apparatus.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 March 2021 Resolved
08 life jackets found inserviceable. Replace to the satisfaction of the attending Marine Inspector. 46 CFR 180.25
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2021
Resolution: Received and reviewed photographic evidence of the replacement of 08 lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 March 2021 Resolved
Marine Inspectors observed rain water entering engine room through main engine deck hatch due to faulty gasket. Remove deck boards and replace gasket to the satisfaction of attending Marine Inspector. 46 CFR 177.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 9 March 2021
Resolution: Visually inspected newly installed sealant, witnessed satisfactory water test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2021 Resolved
Starboard air receiver relief valve would not re-seat during testing. Replace to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-30 46 CFR 54.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2021
Resolved 8 March 2021
Resolution: Received and reviewed photographic evidence attesting to the installation of a new safety relief valve. Attached test report from Regional Valve Corp. to this activity.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 November 2018 Resolved
Manhole hatch cover on the aft starboard side was not watertight. Complete repairs to satisfaction of CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 November 2018
Resolution: Verified manhole hatch cover was watertight.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 November 2018 Resolved
Forward watertight door gasket failed chalk test. Conduct adjustments and or repairs in order to maintain watertight integrity.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2018
Resolution: Verified that repairs were conducted on the forward watertight door gasket. Chalk test was conducted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018 Resolved
Discovered multiple patches on the a/c condenser water cooling line. Complete permanent repairs to the condenser. Repair to the satisfaction of CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 November 2018
Resolution: Permanent repairs to the condensor were verified to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 November 2018 Resolved
Exhaust water flow sensor on port MDE was gagged with paper towel. Upon further inspection it was found to be broken. Repair or replace sensor to bring back system to normal operation. Repair to satisfaction of CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 8 November 2018
Resolution: Replaced flow sensor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 November 2018 Resolved
Sea strainer caps were leaking on Main Diesel Engines. Complete repairs to prevent water accumulation on the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 15 November 2018
Resolution: Sea strainer caps were repaired to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018 Resolved
Water heater relief valve was plugged. Unplug relief valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 8 November 2018
Resolution: Removd plug and installed new Relief Valve
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 November 2018 Resolved
Discovered an oil leak on port SSDG exhaust. Conduct troubleshooting and repairs on the SSDG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 15 November 2018
Resolution: Oil leak on port SSDG exhaust were repaired to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2018 Resolved
Exhaust lagging was loose, missing, or not secure on all engines and evidence of leaks were present. Correct all leaks found and install lagging properly to cover all hot surfaces on the system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 15 November 2018
Resolution: Repaired to the satisfaction of the Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2018 Resolved
Complete pick up welds on the areas marked by the Marine Inspector by the MDE exhaust outlet on the port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 15 November 2018
Resolution: Repaired welds to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 November 2018 Resolved
Float light on one of the Lifefloat was not operating properly. Conduct troubleshooting and repairs or replacement in order to bring back to normal operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 8 November 2018
Resolution: Installed new Battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2018 Resolved
Found 02 life rings with no vessel markings on Port and Stbd superstructure. Mark life rings with vessel's name to satisfaction of CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 8 November 2018
Resolution: Stencilled Name of vessel.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 February 2018 Resolved
U.S. Coast Pilot & CG Light List were old (2016) and need to be updated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 2 February 2018
Resolution: Purchased a new CG Light List.
Lifesaving › Lifefloat › Float Free
Issued 2 February 2018 Resolved
Stacked lifefloats were missing spacers, which need to be installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Provided adequate spacers.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 February 2018 Resolved
Forward accomodation space watertight escape hatch had an inoperable dog, which needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Repaired the dog. All sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 2 February 2018 Resolved
Exhaust piping non-metallic joint is damaged and worn, causing the water to leak in the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Replaced the non-metallic joint with a new one. All sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 February 2018 Resolved
Remotely operated STBD side emergency fuel shutoff did not work and needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Reach rod was repaired and successfully tested on the spot.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 February 2018 Resolved
New emergency lighting fixtures need to be marked with a red letter "E". That same marking must be removed from the old e-light fixtures, which are no longer used on the emergency lighing system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Markings were corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 February 2018 Resolved
Five old Kapok style lifejackets were flat and not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Old lifejackets were replaced with new lifejackets on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.