Records from 1999 to 2017. Most recent: inspection, 28 April 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
28 April 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6134724
20 May 2014
DAPI Audit · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4946011
12 June 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4343450
15 May 2012
Deficiency Check · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4294774
15 May 2012
Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4335017
1 April 2009
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3443072
2 June 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3242518
15 May 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3205651
30 April 2007
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2918952
1 March 2007
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2878319
27 June 2006
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2696279
22 August 2005
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2475211
2 August 2005
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2443852
7 March 2005
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2308205
3 June 2004
Annual Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2085959
14 May 2003
Hull Examination · Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1792675
15 July 2002
Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1645256
29 June 2001
Uninspected Other
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1067680
11 May 2001
Uninspected Other
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1067714
20 July 2000
Uninspected Other
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 822742
23 July 1999
Uninspected Other
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 774830
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 April 2017
No resolution recorded
After required repairs are conducted, Complete new (COI) Inspection for Certification & Credit Drydock exam.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 May 2014
Resolved
Repair & prove proper operation of manual pull cable on fixed gas extinguishing system. (46CFR181.420)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2014
Resolved 23 May 2014
Resolution: Pull cable renewed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 May 2014
Resolved
Labels found faded and unreadable. Re-label remote fuel shut-off valves iaw 46CFR185.608.
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 23 May 2014
Resolution: corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 May 2012
Resolved
Pre-engineered fire extinguishing system and portable fire extinguisher are overdue for annual servicing IAW NFPA 10 and 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 18 May 2012
Resolution: Annual servicing report for portable fire extinguisher and fixed extinguishing system was provided to USCG Inspectors.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2012
Resolved
Remote fuel shutoff marking was worn and unreadable. Marking is not IAW 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 18 May 2012
Resolution: Vessel operator re-stenciled the remote fuel shutoff marking.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 May 2012
Resolved
Lifejacket marking on the vessel for the total number and identification is unreadable. Marking is not IAW 46 CFR 185.604 (f)
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 18 May 2012
Resolution: Lifejacket marking was re-stenciled on the vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 15 May 2012
Resolved
Ringbuoy found in a deteriorated condition and not IAW 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 18 May 2012
Resolution: New ring buoy purchased for vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2012
Resolved
Battery for floating waterlight attached to ringbuoy is expired.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 18 May 2012
Resolution: Operator provided new battery for floating waterlight and logged installation date in the vessel log.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 15 May 2012
Resolved
Exhaust blower interlock with starting switch and ignition switch failed. Vessel blower interlock is not IAW 46 CFR 182.460 (e).
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 18 May 2012
Resolution: Owner had new blower interlock installed and the USCG attending Inspector witnessed satisfactory blower interlock with ignition.
Documentation › Logs/Records › Maneuvering Performance Test Results
Issued 15 May 2012
Resolved
Annual sponson test required by COTP Hampton Roads using CID note from Sector Honolulu as guidance.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 12 June 2012
Resolution: [name withheld] faxed the sponson inspection certificate from MilPro Marine to Marine Inspection Office; all sat.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 15 May 2008
Resolved
Flammable vapor detection system was not operational for the required 30 seconds prior to engine startup. Provide proper operation of flammable vapor detection system IAW 46 CFR 182.480(c) within 30 days and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2008
Resolved 3 July 2008
Resolution: Provided proper operation of flammable vapor detection system IAW 182.480(c).
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 May 2008
Resolved
Coast Guard Light List not onboard vessel. Provide current Coast Guard Light List IAW 46 CFR 184.420.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 2 June 2008
Resolution: Provided current Coast Guard Light List.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 May 2008
Resolved
US Coast Pilot not onboard vessel. Provide current US Coast Pilot IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 2 June 2008
Resolution: Provided current US Coast Pilot.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 May 2008
Resolved
Replace expired alcohol test kits with new kits IAW 46 CFR 4.06 and 46 CFR 16.240.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 2 June 2008
Resolution: Provided new alcohol test kits.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 15 May 2008
Resolved
Replace waterlight lanyard with polypropylene (or similar) line IAW 46 CFR 180.70(d).
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 2 June 2008
Resolution: Replaced waterlight lanyard with polypropylene line.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 15 May 2008
Resolved
Waterlight holding bracket was broken. Replace broken bracket IAW 46 CFR 180.70(d).
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 2 June 2008
Resolution: Replaced broken waterlight bracket.
Personnel › Training › First Aid/CPR
Issued 15 May 2008
Resolved
Several items (burn creams, sunscreen packets, motion sickness pills) in the first aid kit were expired. Replace old first aid kit with a new first aid kit IAW 46 CFR 184.710 and 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 2 June 2008
Resolution: Replaced old first aid kit.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 August 2005
Resolved
Provide upto date tidal tables.
Condition: Unknown
Due 16 August 2005
Resolved 22 August 2005
Resolution: Provided updated tidal tables.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2005
Resolved
Provide first aid kit.
Condition: Unknown
Due 16 August 2005
Resolved 22 August 2005
Resolution: Provided first aid kit.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 2 August 2005
Resolved
Provide segration of Adult and Child lifejackets.
Due 16 August 2005
Resolved 22 August 2005
Resolution: Segragated Adult and Child lifejackets.
Lifesaving › Lifebuoys › Serviceable
Issued 2 August 2005
Resolved
Provide Retroreflective tape to both sides of lifebuoy.
Due 16 August 2005
Resolved 22 August 2005
Resolution: Provided retro tape to both sides of lifebuoy.
Electrical › Lighting (emergency)
Issued 14 May 2003
Resolved
Provide (02) two hand portable lights. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2003
Resolved 16 May 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 14 May 2003
Resolved
Provide proof of annual servicing of Fixed Gas Extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2003
Resolved 16 May 2003
Lifesaving › Hand Flares
Issued 14 May 2003
Resolved
Provide (02) two additional orange smoke distress signals. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2003
Resolved 16 May 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 May 2003
Resolved
Provide (01) adult & (01) child type I life jacket.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2003
Resolved 16 May 2003
Lifesaving › Lifejacket/PFD (Type IV)
Issued 14 May 2003
Resolved
Provide retro reflective tape as needed to extra ring buoy. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2003
Resolved 16 May 2003