Records from 1982 to 2026. Most recent: inspection, 7 January 2026.
Inspection history · 69
7 January 2026
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8279685
3 September 2025
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8227667
14 January 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8063170
22 January 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7857612
22 August 2023
Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7773914
18 January 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7624204
15 June 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7477888
14 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416639
2 February 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7389863
11 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7379619
7 January 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7118082
1 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7047930
7 February 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6917036
30 January 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616439
5 September 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6525637
16 January 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6338755
20 November 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6334154
23 January 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6075720
8 January 2016
DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5788928
25 August 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5225904
22 November 2010
MTSA/ISPS Verification · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3925496
5 January 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3387703
15 August 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3317156
6 November 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3094280
30 October 2006
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2810669
27 September 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2808806
14 March 2006
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2602542
13 February 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2585245
14 January 2005
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2274879
23 August 2004
Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2174155
2 May 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2058914
12 November 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1946519
6 January 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1727783
9 April 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602957
9 November 2001
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1370407
28 September 2001
Type not recorded
No type recorded · Station Morro Bay · USCG Southwest District (CGD-SW) · Activity 1522972
31 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072870
18 June 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443203
22 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462137
20 July 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423219
23 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125789
26 January 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467097
30 January 1998
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1028515
1 December 1997
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1398798
15 July 1997
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1378117
6 January 1997
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1120831
2 December 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400455
9 January 1996
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396466
7 December 1995
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1398368
21 July 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468792
12 December 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1459140
16 December 1993
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1162981
14 June 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1151731
17 December 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 962789
18 December 1991
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1269997
9 January 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911060
24 July 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1223564
10 January 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1222612
17 January 1989
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 893057
18 August 1988
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1043298
9 February 1988
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1015554
9 February 1988
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1332331
25 February 1987
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1017822
30 July 1986
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 985054
13 August 1985
Credit Drydock · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 985350
21 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1288026
23 February 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973417
22 February 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 966432
3 March 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 969492
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2025
Resolved
Port running light not functional. Vessel restricted to operations during periods where navigation lights are not required (e.g. daylight hours, unrestricted visibility).
Action required: 705 - Other - as specified
Due 27 January 2025
Resolved 22 January 2025
Resolution: Received photos os new light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 January 2025
Resolved
Vessel carrying a Life Sling for the recovery of a helpless person from the water. Appliance manufacturer requires a 5 to 1 block and tackle with self arrest device (cam cleat). Provide proper tackle for this device for it to be considered equivalent to a rescue boat.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 22 January 2025
Resolution: Proper tackle verified on board.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 14 January 2025
Resolved
Vessel was required to comply with elements of Safer Seas Act on December 23,2024. Compliance with these elements (Display of information, surveillance requirements, response training, etc.) has not been demonstrated. Provide the [name withheld] a plan for compliance with the Safer Seas Act within 14 days. 46 USC 3106, 46 USC 4901
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 18 February 2025
Resolution: Plan received.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 14 January 2025
Resolved
Vessel was required to comply with elements of Safer Seas Act on December 23,2024. Compliance with these elements (surveillance requirements) has not been demonstrated. Full compliance with the act is required no later than the next scheduled dry dock. 46 USC 3106, 46 USC 4901
Action required: 705 - Other - as specified
Due 30 September 2025
Resolved 21 October 2025
Resolution: Surveillance equipment installed and tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 January 2023
Resolved
Fixed fire fighting system on the vessels paint locker
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2023
Resolved 27 March 2023
Resolution: Extinguisher serviced.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 June 2022
Resolved
Loss of AIS while transitting from Neah Bay to Shilshole
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2022
Resolved 19 July 2022
Resolution: AIS repaired, verified AIS transmittiing.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 January 2022
Resolved
Engine room escape hatch internal handle not permanently attached. Handle stowed separately in engine room may not be accessible in a fire. Provide attached handle as originally provided so hatch can be immediately functional for both sides. 46 CFR 177.500(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 2 February 2022
Resolution: Engine room emergency escape hatch internal handle permanently attached.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 11 January 2022
Resolved
Automatic submersible pump installed in shaft "clear well" will bump water from the bilge system directly overboard without filtration equipment. Remove pump and retain bilge liquids onboard to be discharged ashore or provide approved filtering equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 13 January 2022
Resolution: Pump removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2022
Resolved
Waterlight floats an its side reducing the arch of visibility to approximately 180 degrees. Cause not determined. The current configuration no longer complies with 46CFR180.70(d)(1). Provide functional approved waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 2 February 2022
Resolution: Confirmed installation of new water light.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 18 January 2018
Resolved
Hose from oil sending unit was not the approved type. Chief was informed that he must use sleeving to cover the hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2018
Resolved 12 February 2018
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 18 January 2018
Resolved
Hydrostatic releases were expired on both life rafts
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2018
Resolved 12 February 2018
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 16 January 2018
Resolved
Elbow on exhaust manifild was not coated or covered by lagging
Condition: Damaged By Earlier Event
Due 18 February 2018
Resolved 18 February 2018
Fire Fighting › Fire Hoses › Condition
Issued 23 January 2017
Resolved
Both fire hoses leaking/lining rotted. Replace/renew both required fifty foot fire hoses.
Condition: Improper/Lack of Maintenance
Due 27 January 2017
Resolved 25 January 2017
Resolution: Hoses replaced.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 January 2011
Resolved
Three of the Type I PFD's had worn retro tape.
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 10 January 2011
Resolution: Repalced worn PFD''''s with three new Type I PFD''''s.
Lifesaving › Lifejacket/PFD (Type V) › Storage
Issued 10 January 2011
Resolved
Immersion suites were improperly stowed.
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 10 January 2011
Resolution: Conducted training on proper stowage of Immersion suites.
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 10 January 2011
Resolved
Port MDE Freshwater Jacket hose only had one hose clamp.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 10 January 2011
Resolution: Port MDE freshwater jacket hose replaced with two hose clamps.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 2 January 2009
Resolved
The #1 Main Diesel Engine jacket water cooling system hose was not double clamped. Engine was recently rebuilt and technician did not double clamp cooling system hoses. Repairs were made on the spot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 5 January 2009
Resolution: Cooling system hose was double clamped prior to the departure of Coast Guard Marine Inspector.
Fire Fighting › Fire Main › Condition
Issued 5 November 2007
Resolved
Repair leaking fitting located in engine room on aft bulkhead. Check condition of pipe and renew if wasted.
Condition: Improper/Lack of Maintenance
Due 5 December 2007
Resolved 27 November 2007
Resolution: Replaced pipe and tested sat.
Communications › Radio Communications › EPIRB
Issued 7 November 2006
Resolved
Hydro release for EPIRB does not have yr date for expiration of testing. Prove test date of Hydrostatic release.
Action required: 705 - Other - as specified
Due 9 November 2006
Resolved 10 November 2006
Resolution: Installed new hydrostatic release.
Engineering › Bilge Water Management System › Piping
Issued 7 November 2006
Resolved
Port aft bilge pump piping corroded. Leaking water on outboard side of discharge valve. Renew.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 10 November 2006
Resolution: Renewed wasted piping.
Electrical › Electric Supply System (service) › Cable
Issued 13 February 2006
Resolved
Remove extension cord to power means of electricity used in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 February 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 February 2006
Resolved
Supply battery container cracked on lower left housing located aft of bridge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 March 2006
Resolution: New container in place.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 February 2006
Resolved
No date of last hydro test for 2 CO2 extinguishers. No sail item given to vessel for the following deficiency.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2006
Resolved 13 February 2006
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 13 February 2006
Resolved
Overdue air receiver for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 March 2006
Resolution: Inpsected air rcvr.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 February 2006
Resolved
Place electrical outlet covers missing in wash room compartment (3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 February 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 February 2006
Resolved
Remove work boat on top of container which obstructs visibility of stern light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 February 2006
Lifesaving › Buoyant Apparatus › Float Free
Issued 13 February 2006
Resolved
Place EPIRB in float free location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 March 2006
Resolution: Epirb in float free location.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 13 February 2006
Resolved
Place clip for paint locker CO2 bottle for fixed extinguishing capability.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 February 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 February 2006
Resolved
No record of drills conducted for vessel and crew.
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 March 2006
Resolution: Conducted drills.
Deck/Cargo
Issued 9 November 2001
Resolved
PRIOR TO PLACING VESSEL IN SERVICE PROVE MSC APPROVAL OF CRANE INSTALLATION.
Condition: Unknown
Due 9 November 2001
Resolved 5 April 2002
Resolution: Provided approved plans
Documentation
Issued 9 November 2001
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, OBTAIN NEW STABILITY LETTER TO COVER INSTALLATION OF DECK CRANE.
Condition: Unknown
Due 9 January 2002
Resolved 9 April 2002
Resolution: Vessel issued stability letter dated 15 February 2002 from G-MSC-3
Engineering
Issued 26 January 1999
Resolved
PROVIDE PROPULSION ENGINE STOPS ON BRIDGE.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Lifesaving
Issued 1 December 1997
Resolved
PROVE THAT VESSEL IS SUFFICIENTLY MANEUVERABLE, ARRANGED AND EQUIPPED TO ALLOW THE CREW TO RECOVER A HELPLESS PERSON FROM THE WATER AS PER 46 CFR 180.210 (a) (1) (2) (3) TO THE SATISFACTION OF COGNIZANT OCMI OR INSTALL A RESCUE BOAT ARRANGEMENT AS PER 46 CFR 180.210 (c).
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Engineering
Issued 7 December 1995
Resolved
HYDROTEST AIR RECIVER TO 1.5 TIMES MAWP.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995