Inspection history · 17
21 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8256324
2 June 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8147323
29 August 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7981151
24 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853098
1 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7756812
25 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7554934
17 May 2022
Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7449905
17 August 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7248569
9 March 2020
COI Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6922917
26 December 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6879612
6 December 2019
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6869984
12 September 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6770380
4 September 2018
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6531415
3 May 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6404653
9 November 2017
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6256923
7 July 2016
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5931268
4 May 2016
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5867320
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2025
Resolved
Provide an audible alarm that sounds when the vessel's pre-engineered fixed gas fire extinguishing system (Fireboy) discharges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 2 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2025
Resolved
Replace the retro-reflective material on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 2 June 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 June 2025
Resolved
Provide an updated U.S. Coast Pilot [name withheld] List, and Tide Tables for the area the vessel operates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 2 June 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 August 2023
Resolved
The engine compartment bilge high level alarm visual indicator is inoperable. Repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 August 2022
Resolved
Provide proof of enrollment in a random chemical testing program for all crewmembers in a safety sensitive position. The Captain is enrolled in a random chemical testing program under a different company.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2022
Resolved 29 August 2022
Resolution: Received proof that current company will be notified for random tests and results.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 August 2022
Resolved
Provide an updated Sail Preventative Maintenance Plan rigging inventory and examination/maintenance schedule.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2022
Resolved 29 August 2022
Resolution: Recieved updated rigging PMP.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2022
Resolved
Mouse the shackle pin on the mainmast toggle for the triatic.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2022
Resolved 29 August 2022
Resolution: Received photo with mousing on the shackle pin.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 August 2021
Resolved
The vessel's pre-engineered fixed gas fire extinguishing system is required to be capable of manual actuation from outside the engine compartment. During the Annual inspection it was discovered that the “Fireboy” system was installed without a means to manual activate the system. The vessel rep must provide a means to manual activate the pre-engineered fixed gas fire extinguishing system from outside the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2020
Resolved
10 lifejackets need new reflective tape
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 8 June 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 March 2020
Resolved
FireBoy system malfunctioned due to improper installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2020
Resolved 8 June 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 March 2020
Resolved
No waste management plan onboard
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 8 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 October 2019
Resolved
Installed fire detection system (manufactured by HILLER) must be approved by the Coast Guard and listed in the U.S. Coast Guard Maritime Information eXchange as a Type Approved System or be considered an equivalent by the Marine Safety Center. Fire detection system is required by 46 CFR 181.400(c) and required in the space containing propulsion machinery except when a fixed gas fire extinguishing system is installed that is capable of automatically discharging upon heat detection. Replace installed system with an approved heat detection system or install fixed fire extinguishing system that automatically discharges upon heat detection (Fireboy, Seafire, ect).
Special note added to vessel, defecency remains outstanding.
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 6 July 2020
Resolution: Vessel installed fireboy system. Fire detection panel allowed to remain. Still functional, though not Coast Guard approved. Additionally, the panel also houses the visual and audible signals for the highwater alarms.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2019
Resolved
Provide manufactures instruction/procedures for testing installed fire detection system and model/serial number (Hiller Systems Inc.). Conduct testing of system as per manufactures instructions in the presence of attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2019
Resolution: Detection system tested as per manufactures instructions. All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2019
Resolved
Replace flexible return fuel hose, outside of hose was deteriorating. Flexible hoses over 30" must meet SAE J-1942 with hose end fittings that meet SAE J-1475.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2019
Resolution: Hose replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 September 2019
Resolved
Ventilation closures to E/R shall be able to be secured completely to prevent loss of fire suppressant agent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2019
Resolution: Gaskets placed on ventilation doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2019
Resolved
Connections to battery terminals shall be of the permanent type, wing nuts are not permitted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2019
Resolution: Connections replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 September 2019
Resolved
Replace missing screw on main mast boom connection point for boom traveler.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2019
Resolution: Connection point repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 September 2019
Resolved
Provide additional deck partners/mast shims or re-seat to properly support fore mast.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2019
Resolution: Deck partners adjusted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2019
Resolved
Electrical wires shall be supported with metal supports spaced not more than 24" apart. Wires powering cigarette lighters.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2019
Resolution: Wires supported
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2019
Resolved
Secure diesel fuel leak by way of fuel transfer pump (STBD side). Corrected by tightening connection before completion of inspection.
Action required: 10 - Deficiency Rectified
Resolved 12 September 2019
Resolution: Connection tightened with wrench, rechecked connection after underway and no signs of leak.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 September 2018
Resolved
Provide installation dates for all rigging components listed in Appendix (1) to Enclosure (1) of NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 October 2018
Resolution: Plan in place and submitted to USCG. Uploaded to vessel file.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 September 2018
Resolved
Make available a Rigging Preventative Maintenance Program that provides a level of detail commensurate with Appendix (2) to Enclosure (1) of NVIC 02-16 (Rigging Inventory/Preventative Maintenance Inspection Template (Sample)) or propose a mutually acceptable third party to survey the rigging and provide a report with a level of detailed commensurate with either Appendix (3) or (4) to Enclosure (1) of NVIC 02-16 (Third Party Rigging Survey Samples A&B).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 October 2018
Resolution: Plan submitted to USCG, plan meets requirements in NVIC 02-16.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2018
Resolved
Replace shackle securing block and tackle running gear for boom on main mast.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2018
Resolution: Shackle replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 September 2018
Resolved
Arrange Portable fire extinguisher at operating station so that it is clearly visible or provide label on operation station indicating its location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2018
Resolution: locations clearly marked.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 September 2018
Resolved
Provide NOAA registration sticker for EPIRB and affix to EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2018
Resolution: Sticker on EPIRB.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 9 November 2017
Resolved
Make repairs or renew tach (RPM).
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 1 December 2017
Resolution: Installed new tachometer for engine.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 9 November 2017
Resolved
Bond fuel fill hose and replace fuel fill hose.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 1 December 2017
Resolution: Replaced fill hose and bonded to tank.
Communications › Alarms/Indicators › High Water Alarm
Issued 9 November 2017
Resolved
Relable bilge high level alarm indicator panel.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 1 December 2017
Resolution: Labeled high level indicators.
Engineering › Steering Gear System › Ram
Issued 7 July 2016
Resolved
Ram mount is lose and moves when actuated, required to be serviced/tightened.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 5 August 2016
Resolution: Crew tightened cylinder mounting bolts.
Engineering › Steering Gear System › Linkage
Issued 7 July 2016
Resolved
Ball joint connection rusted frozen, required to be replaced.
Due 7 August 2016
Resolved 5 August 2016
Resolution: Renewed rod end ball joint.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 July 2016
Resolved
Retro on 15 lifejackets unsat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 7 July 2016
Resolution: Retro replaced during inspection
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 7 July 2016
Resolved
Horn/nozzle going into enclosed engine box is cracked, required to be replaced/repaired.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 15 August 2016
Resolution: Renewed horn
Construction/Loadline › Structures › Trunk
Issued 7 July 2016
Resolved
Found crack in deck to forward hatch combing, required to be repaired.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 4 August 2016