CASSIOPEIA LEADER is a 1999 freight ship. The Coast Guard has recorded 31 inspections since 1999, most recently in January 2025, along with 8 deficiencies and 2 operational controls.

Records from 1999 to 2025. Most recent: inspection, 15 January 2025.

Built
1999
Last inspected
15 January 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9182277 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
501769
Flag
JAPAN
—
Maury page id
psix-501769

Inspections, by type

…with no type recorded5
Years with a record 18 calendar years (1999–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17245 - Simplified, Net Ton
57484 - Convention (Subpart B), Gross Ton
17245 - Convention (Subpart B), Net Ton
38874 - Displacement, Ton
21547 - Dead Weight, Ton
57484 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

15 January 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8063778
13 January 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8058622
29 May 2024 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7917069
15 January 2024 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7849432
11 January 2024 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7849775
12 July 2023 PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7736078
16 November 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7595807
16 July 2022 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7502730
12 December 2021 PSC B · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7365316
6 July 2019 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6733652
6 September 2018 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6528986
14 November 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6306384
25 October 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6024334
21 May 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5882783
25 April 2016 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5859323
19 August 2015 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5219688
13 August 2015 STCW 95 Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5215157
13 August 2015 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5215172
27 June 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4893690
11 April 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3450625
31 July 2006 Random ISPS/MTSA/PSC · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2731265
24 July 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2723725
1 May 2006 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2637592
22 October 2005 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2519912
4 July 2003 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1856895
27 June 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1828387
26 February 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1749768
13 December 2002 MARPOL Annex I Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1718688
22 April 2002 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1608055
30 May 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278328
7 August 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 431391

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 January 2024 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame retarding and where necessary, fire resisting properties of the cable. Vessel's steering gear room is outfitted with a lamp over the steering gear which has been spliced into the existing ships power system. 04 splices observed in total. Cite: 74 SOLAS (04) II-1/ 45.5.6 Action: 40ac
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 January 2024
Resolved 16 January 2024
Resolution: Received class report and photos of corrected deficiency. The lamp with its cable and the splices were completely removed for getting back to her original wiring diagram.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 16 November 2022 Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into U.S. Waters.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 November 2022
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 12 December 2021 Resolved
Each Ballast water management system (BWMS) manufactured under Coast Guard approval must have a nameplate which is securely fastened to the BWMS and plainly marked by the manufactures with the information listed in paragraph (b) of this section. Ballast water management system does not have a nameplate.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2022
Resolved 22 December 2021
Resolution: Vessel provided information on Ballast Water Management Treatment System. Vessel does not intend to upgrade to USCG approved upgrade of the type of system onboard. Vessel does not discharge ballast into waters of the United States. See Documents tab.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 September 2018 Resolved
Satisfactory means for safe passage required by regulation 25-1 (in the form of guard rails, lifelines, gangways, etc.) shall be provided for the protection of the crew in getting to and from the machinery space. Guard rail to the right of the entrance to store room was not connected to bulkheads. ICLL Reg 25(4) 88 Protocol
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 September 2018 Resolved
Structural fire protection, including fire-resisting divisions and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if fire occurs. a piece of insulation was missing in the ceiling of the Steering Gear Room. SOLAS 74 (2014) CH II-2/Reg 14.2.1.2.1.1.1
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 September 2018 Resolved
In a ship in which fuel oil is used, the arrangements for storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Accumulations of oil were observed in the engine room coming from drain pipes. Oily rags were also observed in way of baffle bulkhead in the vicinity of the OWS. SOLAS 74 (1997) CH II-2/Reg 15.2
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 September 2018 Resolved
Ventilator openings shall be provided with weathertight closing appliances of steel or other equivalent material. The closing appliances shall be permanently attached, where not so provided, they shall be conveniently stowed near the ventilators to which they are to be fitted. The vent neck to the Emergency Generator Space was wasted with two half-inch penetrations making the vent pipe not airtight when the closing device is closed. ICLL 88 Protocol Reg 19(4)
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
Resolution: Rectified on the spot.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 August 2015 Resolved
0230-Number/composotion (manning)- A dispensation shall not be granted to a master or chief engineer officer except in circumstances of force majeure. The vessels company shall provide a certified chief engineer prior to the vessel's departure. STCW 10 Article VIII
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2015
Resolution: Ship hired new Chief Engineer and PSCO validated his license and endorsement.

Ownership record