TEAL is a 1979 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1985, most recently in February 2022, along with 143 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1985 to 2022. Most recent: inspection, 28 February 2022.

Built
1979
Last inspected
28 February 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2226
Flag
UNITED STATES
368029610
Maury page id
psix-50180

Inspections, by type

…with no type recorded10
…past their stated due date1
Years with a record 34 calendar years (1985–2022)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDJ9807MMSI 368029610 · active · compulsorily equipped · granted 28 March 2018, expires 28 March 2028
WDD2226MMSI 367112590 · expired · compulsorily equipped · granted 23 February 2016, cancelled 27 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
WCW3242MMSI not assigned · expired · compulsorily equipped · granted 20 March 1996, cancelled 20 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
WUR5442MMSI not assigned · expired · compulsorily equipped · granted 17 March 1994, cancelled 27 June 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

28 February 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7403153
20 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7011310
19 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6719386
2 May 2019 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6674877
13 March 2018 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6380074
19 July 2017 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6205369
17 July 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6205334
19 July 2016 DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5933059
8 September 2015 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5214550
15 July 2015 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5150145
5 August 2014 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4923898
10 August 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4111331
2 August 2011 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4069921
13 September 2010 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3838592
29 September 2008 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3269886
26 September 2007 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3062861
6 September 2007 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3050893
28 August 2006 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2759347
19 September 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2495879
8 September 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2494078
18 November 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2243391
22 September 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1909957
21 August 2003 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1890643
25 September 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1683156
16 September 2002 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1673711
24 September 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1075460
12 September 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1405265
21 August 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1429611
19 September 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446990
20 September 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461213
8 September 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1429233
9 March 1999 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808073
21 September 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1381371
3 December 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456538
20 November 1997 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1108799
7 November 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 784696
28 October 1997 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1431850
6 March 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1102448
13 December 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1091480
15 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1459356
12 November 1996 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 862035
25 September 1996 Re-Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1149586
13 March 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 885036
27 November 1995 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 659504
27 November 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1449873
28 September 1995 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1398330
25 August 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 873582
26 September 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1173187
4 November 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 845592
19 May 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1133882
28 September 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1242677
11 August 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1269626
8 November 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942924
26 September 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955801
15 July 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 936443
17 September 1990 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1234441
7 September 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1212375
22 May 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1213438
13 April 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1214601
25 September 1989 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1045167
26 May 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1030785
16 November 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206093
12 October 1988 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1197785
19 October 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1323127
19 October 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1323129
9 October 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1319968
14 May 1987 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1331640
29 September 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1006729
29 August 1986 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1006210
29 October 1985 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1301051
30 May 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 980561

Deficiency record · 143

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2022 No resolution recorded
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete an annual USCG Inspection for 2021. Prior to conducting passenger operations, vessel must be reissued USCG Certificate of Inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 June 2019 Resolved
A TS vessel certificated to carry 49+ passengers shall have a power driven fire pump. The vessels PTO fire pump was inoperable. 46CFR181.10-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2019
Resolution: CG MI'S WITNESSED SATISFACTORY WATER PRESSURE PROVIDED BY THE FIRE PUMP.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 June 2019 Resolved
RAILS OR EQUIVALENT PROTECTION SHALL BE INSTALLED NEAR THE PERIPHERY OF ALL WEATHER DECKS AND SHALL HAVE EVENLY SPACED COURSES THAT DO NOT EXCEED 12-INCHES BETWEEN EACH COURSE. THE DECK RAILS ON THE UPPER DECK WERE DETACTCHED IN MULTIPLE LOCATIONS AND THE COURSES WERE MISSING AT THE STAIRWELL; ADDITIONALLY SEVERAL COURSES WERE NOT TAUGHT THROUGHTOUT THE SHIP. VESSEL IS NOT TO CARRY PASSENGERS ON THE UPPER DECK UNTIL THIS DEFICIENCY IS CLEARED BY AN ATTENDING CG MI. 46CFR177.35(a)/(b)
Action required: 705 - Other - as specified
Due 3 July 2019
Resolved 19 July 2019
Resolution: Rails were repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 June 2019 Resolved
ALL WIRING JONTS/SPLICES SHALL BE MECHANICALLY SECURE AND MADE IN JUNCTION BOXES. THERE WERE MULTIPLE SPLICES THAT WERE NOT IN JUNCTION BOXES (BILGE ALARMS - ALL SPACES, MULTPLE IN E/R AND LAZ), AS WELL AS DEAD END WIRES IN THE E/R AND LAZ. 46CFR183.05-50(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2019
Resolved 22 August 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 June 2019 Resolved
SUBMIT A ONE-LINE DRAWING WITH CIRCUIT PROTECTIONS AND WIRE GAUGE AND SPECIFICATIONS FOR DECORATIVE LIGHTING ON UPPER DECK. 46CFR183.10
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
Resolution: LIGHTS WERE REMOVED FROM THE VESSEL.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2019 Resolved
A VESSEL >26' AND <65' SHALL HAVE AT LEAST ONE RING LIFE BUOY FITTED WITH A LIFELINE ANAD A FLOATING WATERLIGHT ATTACHED WITH A CORROSION RESISTENT CLIP. THE RING LIFE BUOY SHALL ALSO BE OUTFITTED WITH RETROREFLECTIVE TAPE IN ACCORDANCE WITH THE TYPE APPROVAL (46CFR160.050). THE VESSEL'S RING LIFE BUOY HAD A DETERIORATED LIFELINE, A NON-OPERATIONAL CORROSION RESISTENT CLIP, AND THE RETRO-REFLECTIVE MATERIAL WAS NOT AN APPROVED TYPE. 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 19 July 2019
Resolution: Ring life buoy had been outfitted with a new clip, retro tape, and a floating lifeline. Lifeline was yellow polypropelene, stored inside the cabin, in a bag.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 June 2019 Resolved
ALL HATCH COVERS ON WEATHER DECKS SHALL BE FITTED WITH A SAFETY LINE. SAFETY LINE FOR THE FOREPEAK WAS MISSING. 46CFR179.360(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
Resolution: SAFETY LINE WAS ATTACHED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2019 Resolved
VESSEL SHALL CARRY ON BOARD A LIFEJACKET FOR EVERY PERSON AUTHORIZED CARRIAGE BY THE COI. ONE OF THE VESSEL'S ADULT LIFE JACKETS WAS IN A DETERIORATED CONDITION, RENDERING IT INOPERABLE. VESSEL NOT TO CARRY MORE PASSENGERS THAN LIFEJACKETS. 46CFR180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
Resolution: VESSEL HAD SUFFICIENT LIFE JACKETS ON BOARD.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 March 2018 Resolved
Prove proper operation of fixed fire system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel was able to prove proper operation of FFE system
Construction/Loadline › Hull › Transverse Frame
Issued 30 March 2018 Resolved
Repair wood frame in aft port corner as marked and discussed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel repaired wood frame in aft port corner
Navigation › Piloting/Steering › Marine Charts
Issued 30 March 2018 Resolved
Provide up to date and corrected charts for all area of operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel provided updated charts for area of operation
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 March 2018 Resolved
Provide FCC safety certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel provided FCC Safety Certificate
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 30 March 2018 Resolved
Radio needs to be DSC compliant and work correctly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel provided DSC compliant radio
Deck/Cargo › Holds/Tanks › Hatch
Issued 30 March 2018 Resolved
FWD hatch cover needs a cable or line to secure it to the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel installed cable for fwd hatch
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 30 March 2018 Resolved
Provide all required by regulation DAPI paper work.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel provided all DAPI paperwork
Personnel › Certificates/Documents/Licenses › License, Master
Issued 30 March 2018 Resolved
Provide medical certificate for Lic Captain. ([name withheld])
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Fuel Oil Service System › Piping
Issued 30 March 2018 Resolved
Post approved fuel procedure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel posted approved fueling procedures
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 March 2018 Resolved
Conduct MOB&Fire drill with CGMI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: vessel conducted satisfactory MOB and fire drills
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2018 Resolved
Provide a drawing and show completed repair of stern deck to a CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 March 2018 Resolved
Vessel has changed ownership and COTP zones and must complete a New to Zone/COI inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2018
Resolution: Vessel started but did not complete a new to zone/COI inspection.
Construction/Loadline › Hull › Hull Plating
Issued 13 March 2018 Resolved
Vessel is conducting repairs/alterations without approval and permission from the OCMI, vessel must stop all work and submit plans for approval prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2018
Resolution: Vessel sufered damage during a storm which tore a cleat off the vessel and dock, started repair and will complete in a couple of weeks.
Construction/Loadline › Hull › Keel
Issued 19 July 2017 Resolved
Repair marked section on keel where paint/FRP was peeled off at 2/3 aft of vessel. Grind back and repair. (46CFR 176.600)
Action required: 705 - Other - as specified
Resolved 20 July 2017
Resolution: Dried area, ground and replaced FRP and paint.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 September 2015 Resolved
Replace Stern navigatio light lens that is frosted or replace entire light.
Condition: Damaged By Earlier Event
Due 22 October 2015
Resolved 11 September 2015
Resolution: Owner replaced unit with new light fixture.
Accommodation/Occupational Safety › Potable Water System › General
Issued 15 July 2015 Resolved
Replace potable water fitting that is cracked located in steering compartment. 46 CFR 176.818
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 20 July 2015
Resolution: Vessel replaced potable water fitting with new.
Fire Fighting › Fire Main › Valves
Issued 15 July 2015 Resolved
Repair or replace fire main raw water supply valve. Valve is frozen/inoperable. 46 CFR 176.16
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 20 July 2015
Resolution: Vessel rep. replaced fire main raw water supply valve and showed proper operation.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 July 2015 Resolved
Replace both hose clamps on stbd stern tube packing gland. Clamps are waster due to deterioration. 46 CFR 182.720(e)(3)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 20 July 2015
Resolution: Vessel rep. replaced both hose clamps on the stbd stern tube packing gland with new clamps.
Construction/Loadline › Hull › Bracket
Issued 15 July 2015 Resolved
Remove/replace decayed wood on port/stbd muffler collect brackets and preserve. 46 CFR 176.600(d).
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 31 July 2015
Resolution: Removed decayed brackets and installed new brackets on both port/stbd mufflers.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 July 2015 Resolved
Repair or replace battery support brackets located next to aft engine room bulkhead. Brackets are decayed, remove decay and preserve. 46 CFR 176.600(d)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 31 July 2015
Resolution: Removed support brackets for battery and installed new brackets and batter box.
Construction/Loadline › Hull › Keel
Issued 15 July 2015 Resolved
Remove decayed wood on keel and outboard approxmately 6-8 inches and preserve wood located in the forward #2 compartment. 46 CFR 176.600(d)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 31 July 2015
Resolution: Removed decayed wood on keel indentified and preserved wood with resin.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 July 2015 Resolved
Replace hose clamps on bilge line located in foward #2 compartment. 46 CFR 182.720(e)(3)(v)(B).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 20 July 2015
Resolution: Vessel rep. replace hose clamps with new ones on bilge line in forward #2 compartment.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 July 2015 Resolved
Vessels forward bow main deck and stern main deck's non-skid is worn creating a potential slip hazard. Provide texture to deck. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 31 July 2015
Resolution: Installed non-skid coating on bow main decka dn sterns main deck.
Construction/Loadline › Hull › Hull Plating
Issued 15 July 2015 Resolved
Repair areas identified during inspection of underwater hull. Noted 6 soft areas in fiberglass. Area of most concern was located port side forward bow aft of spray rail where underwater body meets side shell. 46 CFR 176.600(d)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 31 July 2015
Resolution: Repaired all areas identifed during hull inspection. Portside bow area had to remove wood that was damaged and replaced with new, area increased to 1'' by 6" with final repair. Other areas were mininum delamination of first coat, repairs SAT.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 July 2015 Resolved
Indentify where water is seeping in located both port/stbd areas in the steering compartment aft were stern meets main deck in corners. Provide proposal for repairs. 46 CFR 176.600(d)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 31 July 2015
Resolution: Stbd side area was identified as opening on stern framing that was decayed allowing intrusion of water. Board was replaced and preserved. Portside appears to be coming from aft window outboard side. Window was resealed.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 August 2014 Resolved
Plastic wire hangers were found throughout the vessel. Owner was instructed to replace with metal supports with chafing every 24 inches.
Action required: 705 - Other - as specified
Due 5 October 2014
Resolved 19 August 2014
Resolution: Plastic wire hangers replaced with metal supports with chafing every 24 inches.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 August 2014 Resolved
Forward rail on the starboard side was missing fasteners creating an unsafe condition. Owner was instructed to replace the missing fasteners.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: Missing fasteners replaced.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 August 2014 Resolved
5" x 5" wood decay just aft of the starboard engine due to water spray from the starboard shaft packing. Owner was instructed to remove the decay and seal the remaining wood.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: Decay was removed. The area was painted and sealed to prevent a reoccurrence.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 5 August 2014 Resolved
No operating instructions for Installed fire fighting system. Owner instructed to provide operating instructions.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: Operating instructions provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 August 2014 Resolved
Ring Buoy water light was extremely dim. Owner was instructed to repair or replace.
Action required: 705 - Other - as specified
Resolved 7 August 2014
Resolution: Owner/operator replaced the Ring Buoy water light.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 August 2011 Resolved
Provide on board 14 additional Type I Adult PFDs to bring the total on board to 119. Passenger count shall be reduced to 102 until corrected. Shall be IAW 46CFR180.71.
Action required: 705 - Other - as specified
Due 16 August 2011
Resolved 5 August 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2011 Resolved
Replace expired burn treatment ointment in first aid kit IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 16 August 2011
Resolved 5 August 2011
Engineering › Gasoline Engine (auxiliary) › Alternator (4 cycle)
Issued 13 September 2010 Resolved
Properly clean/replace oil covered altenators on both main propulsion engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Engineering › Bilge Water Management System › Hose
Issued 13 September 2010 Resolved
Replace flexible hose for fire/bilge system ovbd discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 13 September 2010 Resolved
Hydrostatically test fixed firefighting bottle in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 13 September 2010 Resolved
Repair oil leaks and clean excess oil from both main propulsion engines and the engine room in general.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 13 September 2010 Resolved
Replace flexible hose for aftercooler discharge to exhaust elbow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 September 2010 Resolved
Prove proper crew training on the installed bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 29 September 2008 Resolved
Install (2) smoke detector
Due 6 October 2008
Resolved 1 October 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 September 2008 Resolved
Repair aft bilge high level alarm
Due 6 October 2008
Resolved 29 September 2008
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 September 2008 Resolved
Re-install missing fire installation in engine room
Due 6 October 2008
Resolved 1 October 2008
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 September 2008 Resolved
Mark lifejacket stowage
Due 6 October 2008
Resolved 1 October 2008
Engineering › Fuel Oil Service System › Filter
Issued 26 September 2007 Resolved
Install spark arresters racors.
Due 18 October 2007
Resolved 17 October 2007
Resolution: Verified the proper installation of spark arresters. kpm
Construction/Loadline › Hull › Keel
Issued 6 September 2007 Resolved
Make repairs to the rotted area of the keel plywood overlay (stbd side, aft).
Action required: 705 - Other - as specified
Resolved 11 September 2007
Resolution: Cleared
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 August 2006 Resolved
Post (3) lifejacket donning placard
Due 6 September 2006
Resolved 11 September 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 August 2006 Resolved
Install machinery guards over rotating machinery.
Due 6 September 2006
Resolved 11 September 2006
Engineering › Bilge Water Management System › Not Installed
Issued 28 August 2006 Resolved
Repair light E/R bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 August 2006 Resolved
Replace wing nuts on batteries.
Due 6 September 2006
Resolved 11 September 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 28 August 2006 Resolved
Install guards E/R lights.
Due 6 September 2006
Resolved 11 September 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 September 2003 Resolved
Replace 7 Adult Type II PFD's, vessel is restricted to carrrying 109 passengers until completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2003
Resolved 22 September 2003
Resolution: Owner faxed letter to office attesting to replacement of 7 lifejackets.
Electrical › Electrical Distribution System (service) › Conductor
Issued 22 September 2003 Resolved
Properly support wire run in lazarrette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2003
Resolved 1 October 2003
Resolution: Wire run was suitably supported.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 September 2003 Resolved
Properly support microwave oven to shelf.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2003
Resolved 1 October 2003
Resolution: Oven was strapped down.
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 September 2002 Resolved
PROVIDE ONBOARD AN ADDITIONAL 11 TYPE I ADULT PFD'S. VESSEL RESTRICTED TO CARRYING A TOTAL OF 108 PERSONS. LEGACY COMPONENT DESC: Quantity
Due 16 October 2002
Resolved 25 September 2002
Accommodation/Occupational Safety › Ventilation
Issued 16 September 2002 Resolved
PROPERLY SEAL HALF-MOON SHAPED OPENING IN ENGINEROOM VENT/MAINDECK SEATING AREA PORT AND STARBOARD SIDES.
Due 16 October 2002
Resolved 25 September 2002
Navigation
Issued 12 September 2001 Resolved
PROVIDE CURRENT CHARTS FOR OPERATING AREA.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Navigation
Issued 12 September 2001 Resolved
PROVIDE COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Electrical
Issued 12 September 2001 Resolved
TRACE REMOVE/REPAIR WIRE HANGING IN ENGINE ROOM PORTSIDE.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Lifesaving
Issued 12 September 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Lifesaving
Issued 12 September 2001 Resolved
RENEW RETRO ON 49 ADULT LIFE JACKETS.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Engineering
Issued 12 September 2001 Resolved
INSERT CUT OFF VALVE IN FUEL LINE IN ENGINE ROOM.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Engineering
Issued 12 September 2001 Resolved
SEAL SPACE AROUND FUEL FILL HOLE IN DECK ABOVE TANK ROOM.
Condition: Unknown
Due 21 September 2001
Resolved 24 September 2001
Fire Fighting
Issued 19 September 2000 Resolved
CONDUCT SERVICING ON FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Construction/Loadline
Issued 19 September 2000 Resolved
REPAIR VISUAL INDICATOR ON ENGINE ROOM HIGH BILGE LEVEL ALARM.
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Lifesaving
Issued 19 September 2000 Resolved
OBTAIN 1 ADULT PFD, UNTIL SUCH TIME PASSENGER SHALL BE LIMITED TO 115 AND TOTAL PERSONS TO 118.
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Accommodation/Occupational Safety
Issued 20 September 1999 Resolved
MARK PASSENGER CAPACITY AT ENTRANCE TO UPPER DECK.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Construction/Loadline
Issued 20 September 1999 Resolved
PROVIDE HAND PORTABLE BILGE PUMP IAW 46 CFR 182.520.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Construction/Loadline
Issued 8 September 1999 Resolved
REPLACE GATE VALVE FOR PORT MAIN ENGINE RAW WATER SUPPLY.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 8 September 1999 Resolved
REPOSITION VALVE HANDLE FOR RAW WATER SUPPLY TO GENERATOR. VALVE CANNOT CLOSE IN PRESENT POSITION.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 8 September 1999 Resolved
SUBMIT REPAIR PROPOSAL AND MAKE APPROPRIATE REPAIRS TO HULL IN WAY OF STARBOARD PROP, MID SHIPS AT KEEL AND FORWARD STARBOARD SIDE AT TURN OF KEEL.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 8 September 1999 Resolved
INSTALL VALVES OR CAPS ON THROUGH-HULL FITTINGS WITHIN SIX INCHES OF THE WATERLINE.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Fire Fighting
Issued 9 March 1999 Resolved
PROVE PROPER OPERATION OF FIXED FIRE FIGHTING EXTINGUISHING SYSTEM AT NEXT COAST GUARD INSPECTION.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 28 October 1997 Resolved
Attempted to draw suction from the bilge system for the forepeak compartment without success. System was also unable to provide water pressure to the fire main. Issued requirement to repair & provide operational test in presence of Marine Inspector prior to departure.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 28 October 1997 Resolved
Distress signals not stowed in prper container. Issued requirement to stowin proper container.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Construction/Loadline
Issued 28 October 1997 Resolved
DRYDOCK VESSEL TO EFFECT PULLING OF FASTENERS AS DIRECTED BY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Fire Fighting
Issued 28 October 1997 Resolved
Vessel is in-transit to [name withheld] without full crew. Issued requirement to conduct fire drill in presence of Marine Inspector upon arrival in Tampa AOR.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 28 October 1997 Resolved
Vessel is in-transit, w/o full crew, to [name withheld] Issued requirement to conduct manoverboard drill in presence of Marine Inspector upon arrival in Tampa AOR.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 28 October 1997 Resolved
Child PFDs not stowed separately from Adult PFDs. Issued requirement to separate child from adult PFDs by installing divider in stowage locker and properly marking the outside to indicate location.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 28 October 1997 Resolved
Procedures for donning PFDs not posted. Issued requirement to post.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 28 October 1997 Resolved
Buoyant Apparatus (2) located on the stern of the vessel not properly marked. Issued requirement to mark with name (both sides) and the capacity(18) by 28NOV97.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Electrical
Issued 12 November 1996 Resolved
PROVIDE A BONDING SYSTEM FOR ALL FUEL OIL TANKS AND FILL CONNECTIONS.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 25 September 1996 Resolved
PROVIDE 60' OF LINE ON THE RING BUOY.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Lifesaving
Issued 25 September 1996 Resolved
RENEW LIFE PRESERVER RETROREFLECTIVE TAPE.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Lifesaving
Issued 25 September 1996 Resolved
PROVIDE 6 HAND HELD ORANGE (DAY) DISTRESS FLARES.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Documentation
Issued 25 September 1996 Resolved
PROVIDE A FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Engineering
Issued 25 September 1996 Resolved
REPLACE THE FUEL HOSE FROM FUEL OIL TANK TO THE FILTERS WITH A COAST GUARD APPROVED FLEXIBLE HONSE WHICH MEETS ASTM D1692.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Lifesaving
Issued 25 September 1996 Resolved
CONDUCT A FIRE AND PERSON OVERBOARD DRILL, WITH 1 MASTER AND 2 DECKHANDS.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Navigation
Issued 25 September 1996 Resolved
PROVIDE NAVIGATION CHARTS FROM JACKSONVILLE, FL TO MIAMI, FL.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Construction/Loadline
Issued 25 September 1996 Resolved
CAP THE THUR HULL FITTING WHICH IS NOT IN USE ON THE PORT FORWARD ENGINEROOM SIDE SHELL.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Engineering
Issued 25 September 1996 Resolved
RECONFIGURE FUEL FILL SO THAT IT IS NOT INSIDE THE CABIN.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Electrical
Issued 25 September 1996 Resolved
PROVIDE A BONDING SYSTEM FOR ALL THRU HULL VALVES, FUEL TANK AND RUDDER POSTS.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Documentation
Issued 13 March 1996 Resolved
PROVIDE TO THE OFFICER IN CHARGE, MARINE INSPECTION, JACKSONVILLE, FLORIDA,A COPY OF THE REQUIRED EMPLOYEE ASSISTANCE PROGRAM REQUIRED BY 46 CFR 16.401.
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996
Lifesaving
Issued 28 September 1995 Resolved
BA'S REQUIRED TO HAVE PEOPLE # STENCIL. CORRECT NLT 15OCT1995_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Fire Fighting
Issued 28 September 1995 Resolved
FIRE HOSE NOZZLE REQUIRED TO BE METALIC._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 28 September 1995 Resolved
FIRE STATION VALVE HANDLE REQUIRES REPLACEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 29 September 1995
Electrical
Issued 28 September 1995 Resolved
VESSEL'S INDEPENDENT GENERATOR FOR NON-VITAL SYSTEMS INOP. REPAIR SAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Engineering
Issued 28 September 1995 Resolved
NO EMERGENCY FUEL SHUT OFF STENCIL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 28 September 1995 Resolved
FORWARD SCUTTLE COVER FOR COMPARTMENT FORWARD OF COLLISION BULKHEAD ON MAINDECK REQUIRES OPERATIONAL DOGS FOR CLOSING DEVICE. REPAIR SAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Documentation
Issued 28 September 1995 Resolved
VESSEL REQUIRED TO HAVE DRUG TESTING PROGRAM WITH RAMDOM DRUG TESTING. PROVIDE PROOF OF SAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 October 1995
Resolved 10 October 1995
Lifesaving
Issued 28 September 1995 Resolved
BA'S REQUIRED TO BE FLOAT FREE. CORRECT PRIOR TO CARRYING PASSENGERS FOR 20MILE ROUTE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 13 October 1995
Lifesaving
Issued 28 September 1995 Resolved
BA'S REQUIRED TO HAVE WEAK LINK. CORRECT PRIOR TO CARRYING PASSENGERS FOR 20 MILE ROUTE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 13 October 1995
Lifesaving
Issued 28 September 1995 Resolved
PFD STOWAGE REQUIRES PERSON# STENCIL ON 02 DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 October 1995
Resolved 13 October 1995
Lifesaving
Issued 28 September 1995 Resolved
VESSEL RESTRICTED TO 144 PASSENGERS WITH CREW UNTIL PROPER AMOUNT OF PFD ONBOARD FOR 147. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Engineering
Issued 28 September 1995 Resolved
STARBOARD EXHAUST IN AFT STEERING COMPARTMENT REQUIRES CLAMP. (ONE) MISSING_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Electrical
Issued 26 September 1994 Resolved
REPAIR SHORE TIE CONNECTION ON VESSEL.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Lifesaving
Issued 26 September 1994 Resolved
PROPERLY STENCIL PFD STORAGE BOXES ON UPPER DECK.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Lifesaving
Issued 26 September 1994 Resolved
FABRICATE PFD STOWAGE RACK ON AFT UPPER DECK APER DECK ACCESABLE TO PASSENGERS AND PROPERLY STENCIL.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Lifesaving
Issued 28 September 1992 Resolved
PROPERLY LABEL ALL LIFE JACKET STOWAGE.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Documentation
Issued 28 September 1992 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 28 September 1992 Resolved
REPAIR OR REPLACE ALL RETRO-REFLECTIVE TAPE ON THE LIFEJACKETS.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Navigation
Issued 8 November 1991 Resolved
REPAIR OR REPLACE THE RUDDER BUSHINGS.
Condition: Unknown
Due 15 November 1991
Resolved 24 February 1992
Engineering
Issued 8 November 1991 Resolved
PROPERLY SUPPORT ALL NON-METALIC FLEX HOSES.
Condition: Unknown
Due 15 November 1991
Resolved 24 February 1992
Construction/Loadline
Issued 8 November 1991 Resolved
PROVIDE ACCESS OR REACH ROD FOR THE FOREPEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 15 November 1991
Resolved 24 February 1992
Engineering
Issued 8 November 1991 Resolved
REPLACE ENTIRE FUEL OIL VENT PIPE WITH METALLIC PIPE.
Condition: Unknown
Due 15 November 1991
Resolved 24 February 1992
Lifesaving
Issued 17 September 1990 Resolved
VESSEL RESTRICTED TO CARRYING ONE-HUNDRED AND THIRTY-FIVE (135) PASSENGERS UNITL TEN (10) ADDITIONAL ADULT LIFEJACKETS ARE PLACED ABOARD AND STENCILED.
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Documentation
Issued 17 September 1990 Resolved
POST THE FOLLOWING CERTIFICATES IN SUITABLE FRAMES: 1. CERTIFICATE OF INSPECTION, STABILITY LETTER 2. EMERGENCY CHECK OFF LIST, LIFE JACKET DONNING INSTRUCTIONS 3. GARBAGE AND POLLUTION PLACARDS
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Accommodation/Occupational Safety
Issued 25 September 1989 Resolved
PROVIDE VENTILLATION FOR AFTER STEERING SPACE AS PER 46 CFR 177.20
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Lifesaving
Issued 25 September 1989 Resolved
MARK LIFE JACKET LOCKERS WITH LETTERING AT LEAST ONE (01) INCH HIGH.
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Lifesaving
Issued 25 September 1989 Resolved
REMARK BOUYANT APPARATUS.
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Engineering
Issued 25 September 1989 Resolved
INSTALL APPROVED FUEL HOSES BETWEEN FULE TANK AND FULE FILTERS FOR MAIN ENGINES.
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Electrical
Issued 25 September 1989 Resolved
PROPERLY SECURE DEAD-ENDED ELECTRIC CABLES IN SPACE BEHIND HEAD.
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Fire Fighting
Issued 25 September 1989 Resolved
INSTALL PROPER DISCHARGE HOSE ON FIREPUMP.
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Electrical
Issued 25 September 1989 Resolved
SECURE GENERATOR BATTERY AND PLACE IN PROPER BOX.
Condition: Unknown
Due 25 September 1989
Resolved 25 September 1989
Documentation
Issued 26 May 1989 Resolved
CONDUCT SIMPLIFIED STABILITY TEST IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Electrical
Issued 12 October 1988 Resolved
REMOVE OR PROPERLY SECURE DEAD ENDING ELECTRIC CABLE COMMING FROM SWITH PANEL.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Lifesaving
Issued 12 October 1988 Resolved
RESTENCIL VESSELS NAME AND CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Engineering
Issued 12 October 1988 Resolved
STENCIL LOCATION OF REMOTE FUEL SHUT OFF VALVES.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Engineering
Issued 12 October 1988 Resolved
PROVIDE INDICATING LIGHT FOR AUTOMATIC BILGE PUMP AT HELM STATION.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Engineering
Issued 12 October 1988 Resolved
RENEW STBD SHAFT COUPLING KEY.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Navigation
Issued 29 October 1985 Resolved
INSTALL LOCKING DEVICES ON CLEVIS PINS AT EACH TILLER ARM.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Lifesaving
Issued 29 October 1985 Resolved
REPLACE WEAK LINK FOR BOUYANT APPARATUS ON TOP DECK WITH ONE SUITABLE FOR MORE THAN 20 PERSONS.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Lifesaving
Issued 29 October 1985 Resolved
RENEW LINES TO WATER LIGHTS ON TWO STARBOARD BOUYANT APPARATUS.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Navigation
Issued 29 October 1985 Resolved
INSTALL AN ANCHOR LIGHT IN ACCORDANCE WITH COLREGS.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Lifesaving
Issued 29 October 1985 Resolved
PROVIDE 14 ADDITIONAL ADULT PFD'S.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Engineering
Issued 29 October 1985 Resolved
REPLACE TWO NON-APPROVED FUEL HOSES ON GENERATOR.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Engineering
Issued 29 October 1985 Resolved
CLEAN OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985