MAURY USCG vessel records Sign in
← All vessels

NEW HORIZON

NEW HORIZON is a 1979 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in August 2025, along with 158 deficiencies and 1 operational control.

Records from 1985 to 2025. Most recent: inspection, 28 August 2025.

Built
1979
Last inspected
28 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRC8360
Flag
UNITED STATES
367785650
Maury page id
psix-50183

Inspections, by type

…with no type recorded4
Years with a record 37 calendar years (1985–2025)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.4 ft × 15.1 ft × 5.2 ft
Registered tonnagegross 32 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM BOAT SHOP INC · HOQUIAM, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ5234MMSI 367785650 · active · compulsorily equipped · granted 29 April 2017, expires 29 April 2027
WRC8360MMSI 367363950 · expired · compulsorily equipped · granted 19 June 2008, cancelled 20 October 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

28 August 2025 COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8215034
5 November 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8023492
8 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821151
15 December 2022 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7609481
13 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608611
8 December 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605908
3 November 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7343104
10 December 2020 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7105633
8 September 2020 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7049215
5 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6849486
28 May 2019 Simplified Stability Test · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6697404
3 April 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6654972
6 December 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6591376
29 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6588793
7 November 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6302897
29 November 2016 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6048465
6 September 2016 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5989886
28 August 2015 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5229100
21 October 2014 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5005113
6 September 2011 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4137393
20 January 2011 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3931805
6 January 2011 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3921403
9 December 2009 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3647385
18 December 2008 Simplified Stability Test · Hull Examination · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3388939
17 November 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3359111
13 November 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3097796
8 February 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2868960
3 October 2005 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2506989
2 June 2005 Plan Review "T" Boat · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2378459
2 February 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277311
20 December 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2262609
4 November 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2178712
13 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1934003
17 March 2003 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1739798
4 February 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1739875
15 January 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1731093
16 December 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718524
13 November 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705168
12 November 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705083
23 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076201
11 September 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395804
8 March 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391510
22 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1057168
5 September 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386880
27 September 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429223
26 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126027
15 March 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806910
3 March 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1432057
28 July 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 798089
4 August 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1119532
23 May 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1394758
22 October 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160950
16 September 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1430297
13 September 1995 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883914
16 May 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 877287
19 August 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874458
9 August 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172419
8 September 1993 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1442074
21 June 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151459
12 May 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148459
12 May 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156783
15 September 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264613
19 August 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941569
19 August 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156782
1 May 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212895
4 September 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924897
20 August 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227732
5 September 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1207761
24 May 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209285
27 September 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044571
6 September 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040607
1 October 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319120
26 August 1987 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1337967
10 February 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1323068
9 September 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1273964
30 April 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1309464
17 January 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996200
20 December 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995067
11 September 1985 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299462

Deficiency record · 158

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 19 out of 50 life jackets were deemed unserviceable due to degraded KPOK or inadequate retro reflective tape. Vessel passenger count reduced to 31 adults/5 children until satisfactory repairs are made to the 19 adult life jackets. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. ER to fresh water tank space was not vapor tight. Restore vapor tight integrity to the satisfaction of the MI. 46 CFR 177.405(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 Resolved
Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose; STBD life ring bracket is broken off. 46 CFR 180.70(b)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Dead end wires behind navigation equipment. 46 CFR 183.200
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve… MI found retro reflective tape to be wasted, name of vessel to be faded on 3 of the life floats and all of the paddles, and gashes on the top most aft life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 3 February 2025
Resolution: Replaced retro and marked vessels name on life floats and paddles clearly, photo added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 November 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found guard for STBD engine belt to be missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 3 February 2025
Resolution: Replaced belt guard for their stbd sengine, photo attached.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MI found hydrostatic release for EPIRB to be expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 3 February 2025
Resolution: Replaced hyrostatic release for their EPIRB, photo attached.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2024 Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. OCMI found no log of monthly tests being conducted on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 November 2024
Resolution: Vessel started monthly EPIRB test log during the inspection
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 November 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI found expired aspirin in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 15 January 2025
Resolution: Sent photo of new bottle of aspirin, photo uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 November 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-ended wires found in pilothouse and in upper section of PORT AFT bulkhead of main cabin.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 15 January 2025
Resolution: Sent photo via email of corrections made to found dead-end wires. Photos uploaded to documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 November 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found anchor bulb to be extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 20 November 2024
Resolution: MI attended vessel, anchor light bulb was replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2023 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. STBD ENG shaft seal leaking excessively while running. Repair shaft seal to satisfaction of Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 18 December 2023
Resolution: Replaced shaft seal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 November 2023 Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Laz hatch missing securing device. Install to satisfaction of Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 6 December 2023
Resolution: Installed securing device.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2023 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. 04 life floats have faded markings. Renew vessel name markings on life floats to satisfaction of Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 6 December 2023
Resolution: Renewed name markings on life floats
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2023 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life and buoyant apparatus. This number must be the number of persons the device is equipped for. Capacity markings are faded on 04 life floats. Renew capacity markings to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 6 December 2023
Resolution: Capacity markings added to life floats
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring life buoy is no longer serviceable. Vessel replaced life ring buoy with 24" ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 November 2023
Resolution: During inspection, owner produced a satifactory 24" ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. During inspection vessel obtained copies of required servicing and installed on vessel in presence of Marine Inspector.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 8 November 2023
Resolution: Opeator provided fire servicing copy prior to completion on inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 December 2022 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life floats had brittle painters, missing retro reflective tape, and required maintenance. Repair life float to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 24 January 2023
Resolution: Repaired life float and completed maintenance
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2022 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life buoy was missing retro reflective material. Attach retro reflective material to life buoy to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 24 January 2023
Resolution: Replaced retroreflective material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled. Label fuel shutoff valves and direction of operation to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 24 January 2023
Resolution: Added placards stating: "Emergency Fuel Shut Off Under White Caps on Deck"
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 2 dead end electrical wires on the aft deck are not removed. Remove wires or re-install equipment to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 28 January 2023
Resolution: Removed wires. Sealed opening.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 December 2022 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Lazarette hatch is missing gasket. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 January 2023
Resolved 24 January 2023
Resolution: Replaced hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2020 Resolved
All vessels shall be provided with adult life preservers for each person carried. 09 PFD's taken out of service. Passenger count restricted to 41 passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 September 2020
Resolution: Operator provided pictures of properly labeled replacement PFD's.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2020 Resolved
Each junction box should be provided with a junction box cover. Blue junction box in forward berthering area and midship compartment is not marine grade and has no cover. 46 CFR 111.75-35(a) [Old T]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: Operator provided picture of replacement junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 8 September 2020 Resolved
Each ring life buoy must be orange in color on a Coastwise route. Life buoy in unservicable condition with faded orange color and cracking on surface. 46 CFR 180.70(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 28 September 2020
Resolution: Operator provided pictures of properly labeled life ring.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 September 2020 Resolved
Machinery equipment must be installed to avoid causing fire. Port side alternator is oil saturated. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 16 September 2020
Resolution: Operator provided picture of cleaned alternator.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 September 2016 Resolved
Replace junction box covers in bunk room and midcompartment. 46 CFR183.05-50(b(
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 9 September 2016
Resolution: Recieved pictures of the appropiate junction box covers.
Lifesaving › Lifefloat › Serviceable
Issued 29 August 2015 Resolved
Replace 2 aft life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Lifesaving › Lifefloat › Painter
Issued 29 August 2015 Resolved
Replace painter line for life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Lifesaving › Lifefloat › Retroreflective Material
Issued 29 August 2015 Resolved
Replace retroreflective material/tape on life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 August 2015 Resolved
Replace 4 adult & 1 child lifejacketss w/ lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Engineering › Fuel Oil Service System › Piping
Issued 28 August 2015 Resolved
Remove fuel in lazarette and provide hazwaste receipt for proper disposal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Engineering › Fuel Oil Service System › Valve
Issued 28 August 2015 Resolved
Replace emergency fuel shut off valves and emergency fuel shut off devices/reach rods. Fuel shut off reach rod on port engine snapped during manual testing while inspector was onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Engineering › Fuel Oil Service System › Piping
Issued 28 August 2015 Resolved
Identify fuel leak on both fuel tanks/lines in lazarette, and properly repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Engineering › Bilge Water Management System › Strainer
Issued 28 August 2015 Resolved
Clean/test bilge strainer in lazarette. Strainer clogged w/ mud and debris.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 August 2015 Resolved
Replace engine room bilge alarm on bridge. Alarm not audible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 August 2015 Resolved
Label bilge alarm panel w/ correct spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 August 2015 Resolved
Replace anchor light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Communications › Radio Communications › EPIRB
Issued 28 August 2015 Resolved
Create monthly EPIRB test log
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 August 2015 Resolved
Conduct u/w MOB and fire drills w/ attending inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2015
Resolution: Observed corrected deficiency.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 October 2014 Resolved
Prove proper operation of fixed fire fighting system engine override. 46 CFR 181.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2014
Resolved 20 November 2014
Resolution: System now functions properly after replacement of the control module.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2011 Resolved
PROVIDE THE FOLLOWING ITMES MISSING FROM THE VESSELS FIRST AID KIT: AMMONIA INHALANTS, ASPIRIN, AND IODINE SWABS. - 46 CFR 160.041
Due 8 October 2011
Resolved 10 October 2011
Lifesaving › Lifefloat › Serviceable
Issued 6 September 2011 Resolved
REPAIR LIFE FLOAT WITH APPROVED PATCH KIT. - 46 CFR 185.700
Due 8 October 2011
Resolved 10 October 2011
Lifesaving › Lifefloat › Markings
Issued 6 September 2011 Resolved
LABEL LIFEFLOAT PADDLE WITH VESSEL'S NAME. - 46 CFR 185.604 (g)
Due 8 October 2011
Resolved 10 October 2011
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 September 2011 Resolved
PROVIDE NEW RETRO TAPE ON LIFE FLOAT. - 46 CFR 160.027
Due 8 October 2011
Resolved 10 October 2011
Documentation › Logs/Records › Drug Test Records
Issued 20 January 2011 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 20 February 2011
Resolved 14 February 2011
Resolution: DER provided DAPI with documentation via email.
Documentation › Logs/Records › Drug Test Records
Issued 20 January 2011 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 20 February 2011
Resolved 14 February 2011
Resolution: DER provided DAPI with documentation via email.
Documentation › Logs/Records › Drug Test Records
Issued 20 January 2011 Resolved
Covered employees list not up to date in accordance with 46 CFR 16.230.
Due 20 February 2011
Resolved 14 February 2011
Resolution: DER provided DAPI with documentation via email.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2011 Resolved
Remove dead end wire in forward compartment overhead.
Condition: Improper Installation
Due 6 January 2011
Resolved 6 January 2011
Resolution: Wire was removed and connection point was properly insulated.
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009 Resolved
Company currently does not have all result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 7 January 2010
Resolved 4 January 2010
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 7 January 2010
Resolved 16 December 2009
Stability › Severe Wind/Roll › General
Issued 28 January 2009 Resolved
Prior to operating on exposed waters/route, satisfactorily complete stability exam in accordance with 46 CFR 178.320(d) or 46 CFR 178.330.
Action required: 705 - Other - as specified
Resolved 10 April 2009
Resolution: New stability letter and COI route restricts vessel to a limited coastwise route.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2008 Resolved
Properly deadend all identified wires in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Resolved 23 January 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2008 Resolved
Properly label ring buoy with vessel's name IAW 46 CFR 185.604(b).
Action required: 705 - Other - as specified
Resolved 17 November 2008
Communications › Radio Communications › EPIRB
Issued 15 November 2007 Resolved
Replace expired hydrostatic release on EPIRB.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Lifesaving › Lifefloat › Netting
Issued 15 November 2007 Resolved
Renew wasted netting line on one lifefloat.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 November 2007 Resolved
Mark ring buoy with vessels name.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Fire Fighting › Fire Bucket › Stenciling
Issued 15 November 2007 Resolved
Properly label one fire bucket.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Fire Fighting › Fire Bucket › Quantity
Issued 15 November 2007 Resolved
Provide third fire bucket.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 November 2007 Resolved
Properly log man overboard and fire drills in logbook.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Engineering › Bilge Water Management System › Pump
Issued 15 November 2007 Resolved
Repair and prove proper operation of bilge pump.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Stability › Watertight Integrity › General
Issued 13 November 2007 Resolved
Tighten screws for opening in collision bulkhead.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 15 February 2005 Resolved
Provide plans to replace welding electrical cables in way of engine room aft bulkhead to approved electrical cables IAW 46CFR 183.340. Plans must be approved prior to start.
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 2 June 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 3 February 2005 Resolved
Double hose clamp fitting on port shaft stuffing box.
Due 2 March 2005
Resolved 3 February 2005
Resolution: Operator corrected on the spot.
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 February 2005 Resolved
Properly repair the outboardmost port longitudinal stringer (upper) in way of the aft bulkhead in the engineroom.
Due 2 March 2005
Resolved 10 February 2005
Construction/Loadline › Hull › Side Shell
Issued 2 February 2005 Resolved
Make repairs to delamintated fiberglass on hull in areas identified by the attending marine inspector, as original and IAW Navigation and Vessel Inspection Circular (NVIC) 8-87. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Due 2 March 2005
Resolved 10 February 2005
Construction/Loadline › Hull › Side Shell
Issued 2 February 2005 Resolved
Submit repair proposal for delaminated fiberglass on stem of vessel, repairs shall be IAW NVIC 8-87. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Due 2 March 2005
Resolved 2 February 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 February 2005 Resolved
Repair as original hand railing on the port bow.
Due 2 March 2005
Resolved 2 March 2005
Engineering › Bilge Water Management System › Not Operational
Issued 2 February 2005 Resolved
Properly secure bilge high level alarm in void under galley.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 3 February 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 February 2005 Resolved
Renew as original port exhaust line penetration in aft bulkhead.
Due 2 March 2005
Resolved 17 February 2005
Stability › Weathertight Integrity › General
Issued 2 February 2005 Resolved
Replace wasted deck drain hose located on port forward side of engine room.
Due 2 March 2005
Resolved 10 February 2005
Resolution: Operator replaced the hose and attached a ball valve to the overboard thru hull.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 February 2005 Resolved
Remove and arrest furring to good wood in engine room in way of aft bulkhead and overhead transverse beams.
Due 2 March 2005
Resolved 2 March 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 2 February 2005 Resolved
Properly install cutless bearing securing device on starboard forward strut. Repairs must be made prior to receiving credit for drydock. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Due 2 March 2005
Resolved 4 February 2005
Resolution: Operator provided digital picture.
Engineering › Fuel Oil Service System › Piping
Issued 2 February 2005 Resolved
Make fuel line penetration on lower portion of the aft engine room bulkhead watertight.
Due 2 March 2005
Resolved 2 March 2005
Engineering › Bilge Water Management System › Not Operational
Issued 2 February 2005 Resolved
Prove operation of bilge high level alarm in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 3 February 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 February 2005 Resolved
Remove and arrest furring on bulkhead forward of fuel tanks in lazarette.
Due 2 March 2005
Resolved 2 March 2005
Stability › Watertight Integrity › General
Issued 2 February 2005 Resolved
Prove watertight integrity of watertight hatch on aft deck going into lazarette. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Due 2 March 2005
Resolved 2 March 2005
Stability › Weathertight Integrity › General
Issued 2 February 2005 Resolved
Replace wasted sink overboard drain on port side under galley void.
Due 2 March 2005
Resolved 10 February 2005
Resolution: Operator replaced the hose and fitting and attached a ball valve to the overboard thru hull.
Stability › Watertight Integrity › General
Issued 2 February 2005 Resolved
Install double hose clamps on all flexible hoses that attach to thru hull fittings below the waterline or within 6 inches of deepest load waterline. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Due 2 March 2005
Resolved 10 February 2005
Construction/Loadline › Hull › Side Shell
Issued 2 February 2005 Resolved
Repair crack in gel coat (fiberglass) in way of portside fantail fuel vent bracing.
Due 2 March 2005
Resolved 17 February 2005
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 4 November 2004 Resolved
Provide proof of current CPR certification for 50% of vessel's crew.
Due 4 December 2004
Resolved 13 December 2004
Resolution: Proof of current CPR certification provided via fascmille on 12/13/04.
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 4 November 2004 Resolved
Provide proof of designated senior deckhands.
Due 4 December 2004
Resolved 13 December 2004
Resolution: Copy of Designation of Senior Deckhand letter recieved via fascmille 12/13/04.
Lifesaving › Buoyant Apparatus › Float Free
Issued 4 November 2004 Resolved
Make 5 life floats float free. COS.
Action required: 705 - Other - as specified
Due 4 December 2004
Resolved 4 November 2004
Resolution: 5 life floats made float free. COS 11/04/04
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 4 November 2004 Resolved
Renew port inboard life float waterlight IAW 46 CFR 180.175
Action required: 705 - Other - as specified
Due 4 December 2004
Resolved 4 November 2004
Resolution: Port inboard life float waterlight replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 November 2004 Resolved
Make EPIRB float free IAW 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 4 December 2004
Resolved 4 November 2004
Resolution: Operator made EPIRB float free. COS 11/04/04.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 November 2003 Resolved
Replace as original pitted J/W hard piping from J/W tank to J/W pump in way of both main engines. 46CFR 182.420
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 6 January 2004
Resolution: Replaced.
Engineering › Fuel Oil Service System
Issued 13 November 2003 Resolved
Provide proof that RACOR fuel filter is CG approved or provide flame shield. 46 CFR 182.455
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 6 January 2004
Resolution: Provided.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 November 2003 Resolved
Provide pully guard for fire / bait tank pump in way of starboard main engine.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 6 January 2004
Resolution: Provided.
Lifesaving › Lifeboat Equipment
Issued 13 November 2003 Resolved
Provide one lifefloat paddle to replace damaged lifefloat paddle. 46 CFR 180.175
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 6 January 2004
Resolution: Provided.
Lifesaving › Lifeboat Equipment
Issued 13 November 2003 Resolved
Permanently attach life float lights to life float. 46 CFR 180.175
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 3 December 2003
Lifesaving › Lifebuoys
Issued 13 November 2003 Resolved
Chage lifering buoy lifeline to a floatable line that complies with 46 CFR 180.170 LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 3 December 2003
Construction/Loadline › Structures
Issued 13 November 2003 Resolved
Abate furring in way of both sides of engineroom aft bulkheads and deck beams in way of fuel tank space. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 3 December 2003
Construction/Loadline › Structures
Issued 17 March 2003 Resolved
Abate furring in way of fwd bulkhead in lazarrette.Proof may be faxed or emailed to the following: Fax: [phone withheld] email rtwilliams @d11.uscg.mil LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 7 October 2003
Resolution: Abated.
Navigation › Piloting/Steering
Issued 16 December 2002 Resolved
Review Chart18680 and update with notice to mariners LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 15 January 2003
Operations/Management › Drills/Instruction
Issued 12 November 2002 Resolved
Conduct and record training as required by 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Fire Fighting › Miscellaneous Items
Issued 12 November 2002 Resolved
Post fixed fire-extinguishing instructions as required by 46 CFR 185.612.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Lifesaving › Buoyant Apparatus
Issued 12 November 2002 Resolved
Properly install lifefloats as required by 46 CFR 180.137.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2002
Engineering › Compressed Air System (control)
Issued 12 November 2002 Resolved
Install exhaust lagging on inboard exhaust pipes.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Engineering › Fuel Oil Service System
Issued 12 November 2002 Resolved
Install bonding wires on fuel oil tank fill pipes as required by 46 CFR 182.445(g). LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 November 2002 Resolved
Repair as new fixed fire extinguishing system machinery shut down device.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 November 2002 Resolved
Repair as new port and starboard running lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2002
Navigation › Piloting/Steering › Notices to Navigation
Issued 12 November 2002 Resolved
Have on board and maintain a current copy of the Lightlist, Tidetables, & Coast Pilot.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Navigation › Piloting/Steering
Issued 12 November 2002 Resolved
Have on board a current chart for the vessel's area of operations including all notice to mariners. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Engineering
Issued 12 November 2002 Resolved
Install battery vent caps on all batteries.
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 12 December 2002
Engineering
Issued 12 November 2002 Resolved
Submit proposal to re-wire bilge alarms as required by 46 CFR part 183.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 15 January 2003
Construction/Loadline › Structures
Issued 12 November 2002 Resolved
Make collision bulkhead access door watertight as required by 46 CFR 182.720 (d)(i). The vessel is restricted to a coastwise route until this requirement is satisfied. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Construction/Loadline › Penetrations
Issued 12 November 2002 Resolved
Make all PVC or plastic bulkhead and deck penetrations watertight as required by 46 CFR 182.720(d)(1)
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 7 October 2003
Resolution: all penetrations made watertight.
Construction/Loadline › Structures
Issued 12 November 2002 Resolved
Make all watertight bulkheads watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 15 January 2003
Engineering › Fuel Oil Service System
Issued 12 November 2002 Resolved
Renew fuel oil vent screens as required by 46 CFR 182.420.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Engineering
Issued 12 November 2002 Resolved
Renew exhaust system clamp on port engine exhaust in way of lazarette.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Lifesaving › Lifebuoys
Issued 12 November 2002 Resolved
Renew deteriorated lifering buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 November 2002 Resolved
Renew 4 child PFD's. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 November 2002 Resolved
Renew 10 adult PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2002
Construction/Loadline
Issued 8 March 2001 Resolved
REATTACH BILGE PIPING IN ENGINEROOM IAW 46 CFR 182.510._x001C_
Condition: Unknown
Due 15 March 2001
Resolved 13 March 2001
Construction/Loadline
Issued 8 March 2001 Resolved
MAKE AFT ENGINEROOM BULKHEAD WATERTIGHT IAW 46 CFR 179.320.
Condition: Unknown
Due 15 March 2001
Resolved 13 March 2001
Engineering
Issued 8 March 2001 Resolved
ADD MACHINERY GUARD TO FORWARD END OF STBD MAIN DIESEL ENGINE IAW 46 CFR 177.910._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Engineering
Issued 16 September 1996 Resolved
MARK FUEL SHUTOFF CAPS WITH DIRECTION OF MOVEMENT TO SHUT VALVES.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Accommodation/Occupational Safety
Issued 16 September 1996 Resolved
SEAL WINDOWS IN MAIN CABIN AND BRIDGE.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Engineering
Issued 16 September 1996 Resolved
REMOVE OIL SOAKED RAGS FROM PORT ENGINE TRANSMISSION (INBOARD SIDE) AND PROPERLY SEAL TO PREVENT LEAKAGE.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Navigation
Issued 16 September 1996 Resolved
PROVIDE A CURRENT LIGHT LIST (ONE ON BOARD FROM '81).
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996 Resolved
PROVIDE 2 ADULT LIFEJACKETS. APPLY REFLECTIVE MATERIAL TO DAMAGED AREAS ON1 CHILD AND 11 ADULT LIFEJACKETS. NUMBER OF PASSENGERS ON LIMITED COASTWISE ROUTE LIMITED TO 35 (PLUS 2 CREW) UNTIL COMPLETE.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Documentation
Issued 13 September 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 September 1995
Resolved 18 October 1995
Navigation
Issued 13 September 1995 Resolved
COMPLETELY PAINT SIDE SCREENS BEHIND NAVIGATIONAL SIDELIGHTS MATTE BLACK.
Condition: Unknown
Due 13 September 1995
Resolved 9 November 1995
Engineering
Issued 13 September 1995 Resolved
PROVIDE LAGGING ON BOTH ENGINES BETWEEN ENGINE MANIFOLD AND POINT OF COOLING WATER INJECTION.
Condition: Unknown
Due 27 September 1995
Resolved 9 November 1995
Navigation
Issued 16 May 1995 Resolved
REPAIR/REPLACE CRACKED STARBOARD RUDDER POST JOURNAL.
Condition: Unknown
Due 16 June 1995
Resolved 13 June 1995
Electrical
Issued 16 May 1995 Resolved
PROPERLY TERMINATE DEAD END WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 16 June 1995
Resolved 13 June 1995
Engineering
Issued 16 May 1995 Resolved
PROPERLY INSTALL BOTH PROPELLERS.
Condition: Unknown
Due 16 June 1995
Resolved 13 June 1995
Engineering
Issued 16 May 1995 Resolved
REINSTALL GUARD ON STARBOARD MAIN DIESEL ALTERNATOR
Condition: Unknown
Due 16 June 1995
Resolved 13 June 1995
Navigation
Issued 9 August 1994 Resolved
PROVIDE CURRENT COPIES OF: TIDE TABLES, CURRENT TABLES, COAST PILOT, AND CHARTS FOR OPERATIONAL AREA (LESS THAN THREE YEARS OF AGE). REQ MAY BE CLEARED BY FAX OF SALES RECEIPT TO MSO SAN FRANCISCO.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Navigation
Issued 8 September 1993 Resolved
Reduce amount of inflow on starboard rudder post.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Lifesaving
Issued 8 September 1993 Resolved
Provide 6 additional adult PFD's.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Lifesaving
Issued 8 September 1993 Resolved
Relocate ring buoy to easily accessible area
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Engineering
Issued 8 September 1993 Resolved
Insulate exhaust pipes in area parrellel to main engines.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Engineering
Issued 8 September 1993 Resolved
Mount guard over vibration damper port main engine._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 12 May 1993 Resolved
CLEAN AND TREAT FURRING IN E/R ON TRANSVERSE FRAMING ABOVE ENGINES.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Lifesaving
Issued 15 September 1992 Resolved
PROVIDE ONE TELESCOPIC BOAT HOOK TO BE USED FOR RETRIVAL OF MAN OVERBOARD.
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Navigation
Issued 19 August 1991 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Navigation
Issued 1 May 1991 Resolved
DRILL AND COTTER PIN STEERING GEAR LINKAGE.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Navigation
Issued 20 August 1990 Resolved
REPACK OR TIGHTEN STBD RUDDER POST PACKING GLAND.
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Engineering
Issued 20 August 1990 Resolved
INSTALL NEW GASKET ON PORT MAIN ENGINE INBOARD EXHAUST MANIFOLD TO STOP EXHAUST LEAK.
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Electrical
Issued 20 August 1990 Resolved
PROPERLY SUPPORT TRANSDUCER WIRE RUN ON AFT BULKHEAD OF MSD COMPARTMENT.
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Navigation
Issued 20 August 1990 Resolved
PROVIDE COMPASS DIVIATION CARD.
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Lifesaving
Issued 6 September 1988 Resolved
VESSEL MUST REPLACE 15 MAN BUOYANT APPARATUS WITH 15 MAN LIFE FLOAT FOR TO BE IN COMPLIANCE WITH OCEAN ENDORSEMENT.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Engineering
Issued 6 September 1988 Resolved
PROVIDE HAND OPERATED BILGE PUMP PRIOR TO GETTING UNDERWAY WITH PASSENGERS FOR HIRE.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Engineering
Issued 6 September 1988 Resolved
PROVIDE PROTECTIVE GUARDS FOR DRIVE BELTS FROM MAIN ENGINES TO THEIR RESPECTIVE ALTERNATORS ON PORT AND STARBOARD SIDES.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Accommodation/Occupational Safety
Issued 26 August 1987 Resolved
PROVIDE GUARD OVER STBD DECK WASH PUMP IN E/R. PULLEYS & BELT SHOULD BE TOTALLY ENCLOSED.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Engineering
Issued 26 August 1987 Resolved
PROVIDE 30X30 WIRE MESH SCREEN ON PORT FUEL TANK VENT.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Lifesaving
Issued 26 August 1987 Resolved
PROVIDE 10 MAN LIFE FLOAT W/PADDLES FOR OCEANS ROUTE. VESSEL IS LIMITED TO THE CARRIAGE OF 17 TOTAL PERSONS FOR OCEANS ROUTE.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Navigation
Issued 9 September 1986 Resolved
PROVE OPERATION OF EPIRB
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Navigation
Issued 11 September 1985 Resolved
REPLACE EPIRB BATTERY.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Accommodation/Occupational Safety
Issued 11 September 1985 Resolved
INSTAL CHAIN & LOCK FOR BOTH MSD VALVES.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Accommodation/Occupational Safety
Issued 11 September 1985 Resolved
MOUNT EMERGENCY EXIT SIGN IN FORWARD BERTHING.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Accommodation/Occupational Safety
Issued 11 September 1985 Resolved
REINFORCE HANDRAILS (STANTIONS 5,6,7 PORT, 3,4 STBD AND TRANSOM).
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Navigation
Issued 11 September 1985 Resolved
REMOUNT STERN LIGHT AS FAR AFT AS PRACTICAL.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Accommodation/Occupational Safety
Issued 11 September 1985 Resolved
PROVIDE "CREW ONLY" LABEL FOR FORWARD BERTHING.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Lifesaving
Issued 11 September 1985 Resolved
PROVIDE LIFEFLOATS FOR 25 PERSONS.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Engineering
Issued 11 September 1985 Resolved
REPLACE PORT & STBD FLAME SCREENS.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985
Accommodation/Occupational Safety
Issued 11 September 1985 Resolved
REPAIR, REPLACE OR REMOVE DIESEL STOVE.
Condition: Unknown
Due 11 September 1985
Resolved 11 September 1985

Ownership record