NEW HORIZON

Built
1979
Last inspected
28 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 August 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WRC8360
Flag
UNITED STATES
Maury page id
psix-50183

Documentation record

Registered dimensions (L × B × D)48.4 ft × 15.1 ft × 5.2 ft
Registered tonnagegross 32 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM BOAT SHOP INC · HOQUIAM, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMONTEREY, CA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 30 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

28 August 2025 COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8215034
5 November 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8023492
8 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821151
15 December 2022 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7609481
13 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608611
8 December 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605908
3 November 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7343104
10 December 2020 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7105633
8 September 2020 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7049215
5 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6849486
28 May 2019 Simplified Stability Test · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6697404
3 April 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6654972
6 December 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6591376
29 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6588793
7 November 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6302897
29 November 2016 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6048465
6 September 2016 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5989886

Deficiency record · 27

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 19 out of 50 life jackets were deemed unserviceable due to degraded KPOK or inadequate retro reflective tape. Vessel passenger count reduced to 31 adults/5 children until satisfactory repairs are made to the 19 adult life jackets. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. ER to fresh water tank space was not vapor tight. Restore vapor tight integrity to the satisfaction of the MI. 46 CFR 177.405(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 Resolved
Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose; STBD life ring bracket is broken off. 46 CFR 180.70(b)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Dead end wires behind navigation equipment. 46 CFR 183.200
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 19 September 2025
Resolution: Completed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve… MI found retro reflective tape to be wasted, name of vessel to be faded on 3 of the life floats and all of the paddles, and gashes on the top most aft life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 3 February 2025
Resolution: Replaced retro and marked vessels name on life floats and paddles clearly, photo added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 November 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found guard for STBD engine belt to be missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 3 February 2025
Resolution: Replaced belt guard for their stbd sengine, photo attached.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MI found hydrostatic release for EPIRB to be expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 3 February 2025
Resolution: Replaced hyrostatic release for their EPIRB, photo attached.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2024 Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. OCMI found no log of monthly tests being conducted on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 November 2024
Resolution: Vessel started monthly EPIRB test log during the inspection
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 November 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI found expired aspirin in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 15 January 2025
Resolution: Sent photo of new bottle of aspirin, photo uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 November 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-ended wires found in pilothouse and in upper section of PORT AFT bulkhead of main cabin.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 15 January 2025
Resolution: Sent photo via email of corrections made to found dead-end wires. Photos uploaded to documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 November 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found anchor bulb to be extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 20 November 2024
Resolution: MI attended vessel, anchor light bulb was replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2023 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. STBD ENG shaft seal leaking excessively while running. Repair shaft seal to satisfaction of Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 18 December 2023
Resolution: Replaced shaft seal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 November 2023 Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Laz hatch missing securing device. Install to satisfaction of Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 6 December 2023
Resolution: Installed securing device.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2023 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. 04 life floats have faded markings. Renew vessel name markings on life floats to satisfaction of Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 6 December 2023
Resolution: Renewed name markings on life floats
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2023 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life and buoyant apparatus. This number must be the number of persons the device is equipped for. Capacity markings are faded on 04 life floats. Renew capacity markings to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 6 December 2023
Resolution: Capacity markings added to life floats
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring life buoy is no longer serviceable. Vessel replaced life ring buoy with 24" ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 November 2023
Resolution: During inspection, owner produced a satifactory 24" ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. During inspection vessel obtained copies of required servicing and installed on vessel in presence of Marine Inspector.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 8 November 2023
Resolution: Opeator provided fire servicing copy prior to completion on inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 December 2022 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life floats had brittle painters, missing retro reflective tape, and required maintenance. Repair life float to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 24 January 2023
Resolution: Repaired life float and completed maintenance
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2022 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life buoy was missing retro reflective material. Attach retro reflective material to life buoy to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 24 January 2023
Resolution: Replaced retroreflective material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled. Label fuel shutoff valves and direction of operation to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 24 January 2023
Resolution: Added placards stating: "Emergency Fuel Shut Off Under White Caps on Deck"
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 2 dead end electrical wires on the aft deck are not removed. Remove wires or re-install equipment to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 28 January 2023
Resolution: Removed wires. Sealed opening.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 December 2022 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Lazarette hatch is missing gasket. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 January 2023
Resolved 24 January 2023
Resolution: Replaced hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2020 Resolved
All vessels shall be provided with adult life preservers for each person carried. 09 PFD's taken out of service. Passenger count restricted to 41 passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 September 2020
Resolution: Operator provided pictures of properly labeled replacement PFD's.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2020 Resolved
Each junction box should be provided with a junction box cover. Blue junction box in forward berthering area and midship compartment is not marine grade and has no cover. 46 CFR 111.75-35(a) [Old T]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: Operator provided picture of replacement junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 8 September 2020 Resolved
Each ring life buoy must be orange in color on a Coastwise route. Life buoy in unservicable condition with faded orange color and cracking on surface. 46 CFR 180.70(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 28 September 2020
Resolution: Operator provided pictures of properly labeled life ring.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 September 2020 Resolved
Machinery equipment must be installed to avoid causing fire. Port side alternator is oil saturated. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 16 September 2020
Resolution: Operator provided picture of cleaned alternator.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 September 2016 Resolved
Replace junction box covers in bunk room and midcompartment. 46 CFR183.05-50(b(
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 9 September 2016
Resolution: Recieved pictures of the appropiate junction box covers.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.