NEW HORIZON is a 1979 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in August 2025, along with 158 deficiencies and 1 operational control.
Records from 1985 to 2025. Most recent: inspection, 28 August 2025.
- Built
- 1979
- Last inspected
- 28 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 158 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
604145
WRC8360
50183
Flag
UNITED STATES
367785650
Maury page id
psix-50183
Inspections, by type
…with no type recorded4
Years with a record
37 calendar years (1985–2025)
The 79 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.4 ft × 15.1 ft × 5.2 ft
Registered tonnagegross 32 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM BOAT SHOP INC · HOQUIAM, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ5234MMSI 367785650 · active · compulsorily equipped · granted 29 April 2017, expires 29 April 2027
WRC8360MMSI 367363950 · expired · compulsorily equipped · granted 19 June 2008, cancelled 20 October 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 79
28 August 2025
COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8215034
5 November 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8023492
8 November 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821151
15 December 2022
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7609481
13 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608611
8 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605908
3 November 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7343104
10 December 2020
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7105633
8 September 2020
COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7049215
5 November 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6849486
28 May 2019
Simplified Stability Test · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6697404
3 April 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6654972
6 December 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6591376
29 November 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6588793
7 November 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6302897
29 November 2016
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6048465
6 September 2016
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5989886
28 August 2015
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5229100
21 October 2014
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5005113
6 September 2011
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4137393
20 January 2011
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3931805
6 January 2011
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3921403
9 December 2009
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3647385
18 December 2008
Simplified Stability Test · Hull Examination · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3388939
17 November 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3359111
13 November 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3097796
8 February 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2868960
3 October 2005
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2506989
2 June 2005
Plan Review "T" Boat · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2378459
2 February 2005
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277311
20 December 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2262609
4 November 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2178712
13 November 2003
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1934003
17 March 2003
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1739798
4 February 2003
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1739875
15 January 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1731093
16 December 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718524
13 November 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705168
12 November 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705083
23 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076201
11 September 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395804
8 March 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391510
22 January 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1057168
5 September 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386880
27 September 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429223
26 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126027
15 March 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806910
3 March 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1432057
28 July 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 798089
4 August 1997
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1119532
23 May 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1394758
22 October 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160950
16 September 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1430297
13 September 1995
Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883914
16 May 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 877287
19 August 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874458
9 August 1994
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172419
8 September 1993
Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1442074
21 June 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151459
12 May 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148459
12 May 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156783
15 September 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264613
19 August 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941569
19 August 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156782
1 May 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212895
4 September 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924897
20 August 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227732
5 September 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1207761
24 May 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209285
27 September 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044571
6 September 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040607
1 October 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319120
26 August 1987
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1337967
10 February 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1323068
9 September 1986
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1273964
30 April 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1309464
17 January 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996200
20 December 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995067
11 September 1985
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299462
Deficiency record · 158
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 19 out of 50 life jackets were deemed unserviceable due to degraded KPOK or inadequate retro reflective tape. Vessel passenger count reduced to 31 adults/5 children until satisfactory repairs are made to the 19 adult life jackets.
46 CFR 176.808(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. ER to fresh water tank space was not vapor tight. Restore vapor tight integrity to the satisfaction of the MI.
46 CFR 177.405(c)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025
Resolved
Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose; STBD life ring bracket is broken off.
46 CFR 180.70(b)(3)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact
with energized parts. Dead end wires behind navigation
equipment.
46 CFR 183.200
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve… MI found retro reflective tape to be wasted, name of vessel to be faded on 3 of the life floats and all of the paddles, and gashes on the top most aft life float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 November 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found guard for STBD engine belt to be missing.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2024
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MI found hydrostatic release for EPIRB to be expired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2024
Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. OCMI found no log of monthly tests being conducted on EPIRB.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 November 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI found expired aspirin in the first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 November 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-ended wires found in pilothouse and in upper section of PORT AFT bulkhead of main cabin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 November 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found anchor bulb to be extinguished.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. STBD ENG shaft seal leaking excessively while running. Repair shaft seal to satisfaction of Marine Inspector
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 November 2023
Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Laz hatch missing securing device. Install to satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2023
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. 04 life floats have faded markings. Renew vessel name markings on life floats to satisfaction of Marine Inspector
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2023
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life and buoyant apparatus. This number must be the number of persons the device is equipped for. Capacity markings are faded on 04 life floats. Renew capacity markings to satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring life buoy is no longer serviceable. Vessel replaced life ring buoy with 24" ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2023
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. During inspection vessel obtained copies of required servicing and installed on vessel in presence of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 December 2022
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life floats had brittle painters, missing retro reflective tape, and required maintenance. Repair life float to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2022
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life buoy was missing retro reflective material. Attach retro reflective material to life buoy to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high
indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled. Label fuel shutoff valves and direction of operation to the satisfaction of the Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 2 dead end electrical wires on the aft deck are not removed. Remove wires or re-install equipment to the satisfaction of the Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 December 2022
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Lazarette hatch is missing gasket. Replace gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2020
Resolved
All vessels shall be provided with adult life preservers for each person carried. 09 PFD's taken out of service. Passenger count restricted to 41 passengers and crew.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2020
Resolved
Each junction box should be provided with a junction box cover. Blue junction box in forward berthering area and midship compartment is not marine grade and has no cover. 46 CFR 111.75-35(a) [Old T]
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 8 September 2020
Resolved
Each ring life buoy must be orange in color on a Coastwise route. Life buoy in unservicable condition with faded orange color and cracking on surface. 46 CFR 180.70(b)(5)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 September 2020
Resolved
Machinery equipment must be installed to avoid causing fire. Port side alternator is oil saturated. 46 CFR 182.100
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 September 2016
Resolved
Replace junction box covers in bunk room and midcompartment. 46 CFR183.05-50(b(
Lifesaving › Lifefloat › Serviceable
Issued 29 August 2015
Resolved
Replace 2 aft life floats.
Lifesaving › Lifefloat › Painter
Issued 29 August 2015
Resolved
Replace painter line for life float.
Lifesaving › Lifefloat › Retroreflective Material
Issued 29 August 2015
Resolved
Replace retroreflective material/tape on life floats.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 August 2015
Resolved
Replace 4 adult & 1 child lifejacketss w/ lights.
Engineering › Fuel Oil Service System › Piping
Issued 28 August 2015
Resolved
Remove fuel in lazarette and provide hazwaste receipt for proper disposal.
Engineering › Fuel Oil Service System › Valve
Issued 28 August 2015
Resolved
Replace emergency fuel shut off valves and emergency fuel shut off devices/reach rods. Fuel shut off reach rod on port engine snapped during manual testing while inspector was onboard.
Engineering › Fuel Oil Service System › Piping
Issued 28 August 2015
Resolved
Identify fuel leak on both fuel tanks/lines in lazarette, and properly repair.
Engineering › Bilge Water Management System › Strainer
Issued 28 August 2015
Resolved
Clean/test bilge strainer in lazarette. Strainer clogged w/ mud and debris.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 August 2015
Resolved
Replace engine room bilge alarm on bridge. Alarm not audible.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 August 2015
Resolved
Label bilge alarm panel w/ correct spaces.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 August 2015
Resolved
Replace anchor light.
Communications › Radio Communications › EPIRB
Issued 28 August 2015
Resolved
Create monthly EPIRB test log
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 August 2015
Resolved
Conduct u/w MOB and fire drills w/ attending inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 October 2014
Resolved
Prove proper operation of fixed fire fighting system engine override. 46 CFR 181.420
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2011
Resolved
PROVIDE THE FOLLOWING ITMES MISSING FROM THE VESSELS FIRST AID KIT: AMMONIA INHALANTS, ASPIRIN, AND IODINE SWABS. - 46 CFR 160.041
Lifesaving › Lifefloat › Serviceable
Issued 6 September 2011
Resolved
REPAIR LIFE FLOAT WITH APPROVED PATCH KIT. - 46 CFR 185.700
Lifesaving › Lifefloat › Markings
Issued 6 September 2011
Resolved
LABEL LIFEFLOAT PADDLE WITH VESSEL'S NAME. - 46 CFR 185.604 (g)
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 September 2011
Resolved
PROVIDE NEW RETRO TAPE ON LIFE FLOAT. - 46 CFR 160.027
Documentation › Logs/Records › Drug Test Records
Issued 20 January 2011
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Documentation › Logs/Records › Drug Test Records
Issued 20 January 2011
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 20 January 2011
Resolved
Covered employees list not up to date in accordance with 46 CFR 16.230.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2011
Resolved
Remove dead end wire in forward compartment overhead.
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Company currently does not have all result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Stability › Severe Wind/Roll › General
Issued 28 January 2009
Resolved
Prior to operating on exposed waters/route, satisfactorily complete stability exam in accordance with 46 CFR 178.320(d) or 46 CFR 178.330.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2008
Resolved
Properly deadend all identified wires in accordance with 46 CFR 183.340.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2008
Resolved
Properly label ring buoy with vessel's name IAW 46 CFR 185.604(b).
Communications › Radio Communications › EPIRB
Issued 15 November 2007
Resolved
Replace expired hydrostatic release on EPIRB.
Lifesaving › Lifefloat › Netting
Issued 15 November 2007
Resolved
Renew wasted netting line on one lifefloat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 November 2007
Resolved
Mark ring buoy with vessels name.
Fire Fighting › Fire Bucket › Stenciling
Issued 15 November 2007
Resolved
Properly label one fire bucket.
Fire Fighting › Fire Bucket › Quantity
Issued 15 November 2007
Resolved
Provide third fire bucket.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 November 2007
Resolved
Properly log man overboard and fire drills in logbook.
Engineering › Bilge Water Management System › Pump
Issued 15 November 2007
Resolved
Repair and prove proper operation of bilge pump.
Stability › Watertight Integrity › General
Issued 13 November 2007
Resolved
Tighten screws for opening in collision bulkhead.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 February 2005
Resolved
Provide plans to replace welding electrical cables in way of engine room aft bulkhead to approved electrical cables IAW 46CFR 183.340. Plans must be approved prior to start.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 3 February 2005
Resolved
Double hose clamp fitting on port shaft stuffing box.
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 February 2005
Resolved
Properly repair the outboardmost port longitudinal stringer (upper) in way of the aft bulkhead in the engineroom.
Construction/Loadline › Hull › Side Shell
Issued 2 February 2005
Resolved
Make repairs to delamintated fiberglass on hull in areas identified by the attending marine inspector, as original and IAW Navigation and Vessel Inspection Circular (NVIC) 8-87. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Construction/Loadline › Hull › Side Shell
Issued 2 February 2005
Resolved
Submit repair proposal for delaminated fiberglass on stem of vessel, repairs shall be IAW NVIC 8-87. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 February 2005
Resolved
Repair as original hand railing on the port bow.
Engineering › Bilge Water Management System › Not Operational
Issued 2 February 2005
Resolved
Properly secure bilge high level alarm in void under galley.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 February 2005
Resolved
Renew as original port exhaust line penetration in aft bulkhead.
Stability › Weathertight Integrity › General
Issued 2 February 2005
Resolved
Replace wasted deck drain hose located on port forward side of engine room.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 February 2005
Resolved
Remove and arrest furring to good wood in engine room in way of aft bulkhead and overhead transverse beams.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 2 February 2005
Resolved
Properly install cutless bearing securing device on starboard forward strut. Repairs must be made prior to receiving credit for drydock. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Engineering › Fuel Oil Service System › Piping
Issued 2 February 2005
Resolved
Make fuel line penetration on lower portion of the aft engine room bulkhead watertight.
Engineering › Bilge Water Management System › Not Operational
Issued 2 February 2005
Resolved
Prove operation of bilge high level alarm in lazarette.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 February 2005
Resolved
Remove and arrest furring on bulkhead forward of fuel tanks in lazarette.
Stability › Watertight Integrity › General
Issued 2 February 2005
Resolved
Prove watertight integrity of watertight hatch on aft deck going into lazarette. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Stability › Weathertight Integrity › General
Issued 2 February 2005
Resolved
Replace wasted sink overboard drain on port side under galley void.
Stability › Watertight Integrity › General
Issued 2 February 2005
Resolved
Install double hose clamps on all flexible hoses that attach to thru hull fittings below the waterline or within 6 inches of deepest load waterline. Repairs must be completed prior to receiving credit for drydock but not later than 02MAR05.
Construction/Loadline › Hull › Side Shell
Issued 2 February 2005
Resolved
Repair crack in gel coat (fiberglass) in way of portside fantail fuel vent bracing.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 4 November 2004
Resolved
Provide proof of current CPR certification for 50% of vessel's crew.
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 4 November 2004
Resolved
Provide proof of designated senior deckhands.
Lifesaving › Buoyant Apparatus › Float Free
Issued 4 November 2004
Resolved
Make 5 life floats float free. COS.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 4 November 2004
Resolved
Renew port inboard life float waterlight IAW 46 CFR 180.175
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 November 2004
Resolved
Make EPIRB float free IAW 46 CFR 180.64.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 November 2003
Resolved
Replace as original pitted J/W hard piping from J/W tank to J/W pump in way of both main engines.
46CFR 182.420
Engineering › Fuel Oil Service System
Issued 13 November 2003
Resolved
Provide proof that RACOR fuel filter is CG approved or provide flame shield.
46 CFR 182.455
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 November 2003
Resolved
Provide pully guard for fire / bait tank pump in way of starboard main engine.
Lifesaving › Lifeboat Equipment
Issued 13 November 2003
Resolved
Provide one lifefloat paddle to replace damaged lifefloat paddle.
46 CFR 180.175
Lifesaving › Lifeboat Equipment
Issued 13 November 2003
Resolved
Permanently attach life float lights to life float.
46 CFR 180.175
Lifesaving › Lifebuoys
Issued 13 November 2003
Resolved
Chage lifering buoy lifeline to a floatable line that complies with 46 CFR 180.170 LEGACY COMPONENT DESC: Buoyant Lifeline
Construction/Loadline › Structures
Issued 13 November 2003
Resolved
Abate furring in way of both sides of engineroom aft bulkheads and deck beams in way of fuel tank space. LEGACY COMPONENT DESC: Transverse Bulkhead
Construction/Loadline › Structures
Issued 17 March 2003
Resolved
Abate furring in way of fwd bulkhead in lazarrette.Proof may be faxed or emailed to the following:
Fax: [phone withheld] email rtwilliams @d11.uscg.mil LEGACY COMPONENT DESC: Transverse Bulkhead
Navigation › Piloting/Steering
Issued 16 December 2002
Resolved
Review Chart18680 and update with notice to mariners LEGACY COMPONENT DESC: Marine Charts
Operations/Management › Drills/Instruction
Issued 12 November 2002
Resolved
Conduct and record training as required by 46 CFR 185.420.
Fire Fighting › Miscellaneous Items
Issued 12 November 2002
Resolved
Post fixed fire-extinguishing instructions as required by 46 CFR 185.612.
Lifesaving › Buoyant Apparatus
Issued 12 November 2002
Resolved
Properly install lifefloats as required by 46 CFR 180.137.
Engineering › Compressed Air System (control)
Issued 12 November 2002
Resolved
Install exhaust lagging on inboard exhaust pipes.
Engineering › Fuel Oil Service System
Issued 12 November 2002
Resolved
Install bonding wires on fuel oil tank fill pipes as required by 46 CFR 182.445(g). LEGACY COMPONENT DESC: Hose
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 November 2002
Resolved
Repair as new fixed fire extinguishing system machinery shut down device.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 November 2002
Resolved
Repair as new port and starboard running lights.
Navigation › Piloting/Steering › Notices to Navigation
Issued 12 November 2002
Resolved
Have on board and maintain a current copy of the Lightlist, Tidetables, & Coast Pilot.
Navigation › Piloting/Steering
Issued 12 November 2002
Resolved
Have on board a current chart for the vessel's area of operations including all notice to mariners. LEGACY COMPONENT DESC: Marine Charts
Engineering
Issued 12 November 2002
Resolved
Install battery vent caps on all batteries.
Engineering
Issued 12 November 2002
Resolved
Submit proposal to re-wire bilge alarms as required by 46 CFR part 183.
Construction/Loadline › Structures
Issued 12 November 2002
Resolved
Make collision bulkhead access door watertight as required by 46 CFR 182.720 (d)(i). The vessel is restricted to a coastwise route until this requirement is satisfied.
LEGACY COMPONENT DESC: Transverse Bulkhead
Construction/Loadline › Penetrations
Issued 12 November 2002
Resolved
Make all PVC or plastic bulkhead and deck penetrations watertight as required by 46 CFR 182.720(d)(1)
Construction/Loadline › Structures
Issued 12 November 2002
Resolved
Make all watertight bulkheads watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Engineering › Fuel Oil Service System
Issued 12 November 2002
Resolved
Renew fuel oil vent screens as required by 46 CFR 182.420.
Engineering
Issued 12 November 2002
Resolved
Renew exhaust system clamp on port engine exhaust in way of lazarette.
Lifesaving › Lifebuoys
Issued 12 November 2002
Resolved
Renew deteriorated lifering buoy.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 November 2002
Resolved
Renew 4 child PFD's. LEGACY COMPONENT DESC: Condition
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 November 2002
Resolved
Renew 10 adult PFD's.
Construction/Loadline
Issued 8 March 2001
Resolved
REATTACH BILGE PIPING IN ENGINEROOM IAW 46 CFR 182.510._x001C_
Construction/Loadline
Issued 8 March 2001
Resolved
MAKE AFT ENGINEROOM BULKHEAD WATERTIGHT IAW 46 CFR 179.320.
Engineering
Issued 8 March 2001
Resolved
ADD MACHINERY GUARD TO FORWARD END OF STBD MAIN DIESEL ENGINE IAW 46 CFR 177.910._x001C_ _x001C_ _x001C_
Engineering
Issued 16 September 1996
Resolved
MARK FUEL SHUTOFF CAPS WITH DIRECTION OF MOVEMENT TO SHUT VALVES.
Accommodation/Occupational Safety
Issued 16 September 1996
Resolved
SEAL WINDOWS IN MAIN CABIN AND BRIDGE.
Engineering
Issued 16 September 1996
Resolved
REMOVE OIL SOAKED RAGS FROM PORT ENGINE TRANSMISSION (INBOARD SIDE) AND PROPERLY SEAL TO PREVENT LEAKAGE.
Navigation
Issued 16 September 1996
Resolved
PROVIDE A CURRENT LIGHT LIST (ONE ON BOARD FROM '81).
Lifesaving
Issued 16 September 1996
Resolved
PROVIDE 2 ADULT LIFEJACKETS. APPLY REFLECTIVE MATERIAL TO DAMAGED AREAS ON1 CHILD AND 11 ADULT LIFEJACKETS. NUMBER OF PASSENGERS ON LIMITED COASTWISE ROUTE LIMITED TO 35 (PLUS 2 CREW) UNTIL COMPLETE.
Documentation
Issued 13 September 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 13 September 1995
Resolved
COMPLETELY PAINT SIDE SCREENS BEHIND NAVIGATIONAL SIDELIGHTS MATTE BLACK.
Engineering
Issued 13 September 1995
Resolved
PROVIDE LAGGING ON BOTH ENGINES BETWEEN ENGINE MANIFOLD AND POINT OF COOLING WATER INJECTION.
Navigation
Issued 16 May 1995
Resolved
REPAIR/REPLACE CRACKED STARBOARD RUDDER POST JOURNAL.
Electrical
Issued 16 May 1995
Resolved
PROPERLY TERMINATE DEAD END WIRING THROUGHOUT VESSEL.
Engineering
Issued 16 May 1995
Resolved
PROPERLY INSTALL BOTH PROPELLERS.
Engineering
Issued 16 May 1995
Resolved
REINSTALL GUARD ON STARBOARD MAIN DIESEL ALTERNATOR
Navigation
Issued 9 August 1994
Resolved
PROVIDE CURRENT COPIES OF: TIDE TABLES, CURRENT TABLES, COAST PILOT, AND CHARTS FOR OPERATIONAL AREA (LESS THAN THREE YEARS OF AGE). REQ MAY BE CLEARED BY FAX OF SALES RECEIPT TO MSO SAN FRANCISCO.
Navigation
Issued 8 September 1993
Resolved
Reduce amount of inflow on starboard rudder post.
Lifesaving
Issued 8 September 1993
Resolved
Provide 6 additional adult PFD's.
Lifesaving
Issued 8 September 1993
Resolved
Relocate ring buoy to easily accessible area
Engineering
Issued 8 September 1993
Resolved
Insulate exhaust pipes in area parrellel to main engines.
Engineering
Issued 8 September 1993
Resolved
Mount guard over vibration damper port main engine._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 12 May 1993
Resolved
CLEAN AND TREAT FURRING IN E/R ON TRANSVERSE FRAMING ABOVE ENGINES.
Lifesaving
Issued 15 September 1992
Resolved
PROVIDE ONE TELESCOPIC BOAT HOOK TO BE USED FOR RETRIVAL OF MAN OVERBOARD.
Navigation
Issued 19 August 1991
Resolved
PROVIDE COMPASS DEVIATION CARD.
Navigation
Issued 1 May 1991
Resolved
DRILL AND COTTER PIN STEERING GEAR LINKAGE.
Navigation
Issued 20 August 1990
Resolved
REPACK OR TIGHTEN STBD RUDDER POST PACKING GLAND.
Engineering
Issued 20 August 1990
Resolved
INSTALL NEW GASKET ON PORT MAIN ENGINE INBOARD EXHAUST MANIFOLD TO STOP EXHAUST LEAK.
Electrical
Issued 20 August 1990
Resolved
PROPERLY SUPPORT TRANSDUCER WIRE RUN ON AFT BULKHEAD OF MSD COMPARTMENT.
Navigation
Issued 20 August 1990
Resolved
PROVIDE COMPASS DIVIATION CARD.
Lifesaving
Issued 6 September 1988
Resolved
VESSEL MUST REPLACE 15 MAN BUOYANT APPARATUS WITH 15 MAN LIFE FLOAT FOR TO BE IN COMPLIANCE WITH OCEAN ENDORSEMENT.
Engineering
Issued 6 September 1988
Resolved
PROVIDE HAND OPERATED BILGE PUMP PRIOR TO GETTING UNDERWAY WITH PASSENGERS FOR HIRE.
Engineering
Issued 6 September 1988
Resolved
PROVIDE PROTECTIVE GUARDS FOR DRIVE BELTS FROM MAIN ENGINES TO THEIR RESPECTIVE ALTERNATORS ON PORT AND STARBOARD SIDES.
Accommodation/Occupational Safety
Issued 26 August 1987
Resolved
PROVIDE GUARD OVER STBD DECK WASH PUMP IN E/R. PULLEYS & BELT SHOULD BE TOTALLY ENCLOSED.
Engineering
Issued 26 August 1987
Resolved
PROVIDE 30X30 WIRE MESH SCREEN ON PORT FUEL TANK VENT.
Lifesaving
Issued 26 August 1987
Resolved
PROVIDE 10 MAN LIFE FLOAT W/PADDLES FOR OCEANS ROUTE. VESSEL IS LIMITED TO THE CARRIAGE OF 17 TOTAL PERSONS FOR OCEANS ROUTE.
Navigation
Issued 9 September 1986
Resolved
PROVE OPERATION OF EPIRB
Navigation
Issued 11 September 1985
Resolved
REPLACE EPIRB BATTERY.
Accommodation/Occupational Safety
Issued 11 September 1985
Resolved
INSTAL CHAIN & LOCK FOR BOTH MSD VALVES.
Accommodation/Occupational Safety
Issued 11 September 1985
Resolved
MOUNT EMERGENCY EXIT SIGN IN FORWARD BERTHING.
Accommodation/Occupational Safety
Issued 11 September 1985
Resolved
REINFORCE HANDRAILS (STANTIONS 5,6,7 PORT, 3,4 STBD AND TRANSOM).
Navigation
Issued 11 September 1985
Resolved
REMOUNT STERN LIGHT AS FAR AFT AS PRACTICAL.
Accommodation/Occupational Safety
Issued 11 September 1985
Resolved
PROVIDE "CREW ONLY" LABEL FOR FORWARD BERTHING.
Lifesaving
Issued 11 September 1985
Resolved
PROVIDE LIFEFLOATS FOR 25 PERSONS.
Engineering
Issued 11 September 1985
Resolved
REPLACE PORT & STBD FLAME SCREENS.
Accommodation/Occupational Safety
Issued 11 September 1985
Resolved
REPAIR, REPLACE OR REMOVE DIESEL STOVE.