MAURY USCG vessel records
← All vessels

KADAHO

KADAHO is a 1979 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in April 2026, along with 8 deficiencies and 1 casualty investigation in 2002.

Records from 2002 to 2026. Most recent: inspection, 15 April 2026.

Built
1979
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6501
Flag
UNITED STATES
Maury page id
psix-50188

Documentation record

Registered dimensions (L × B × D)48.2 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDEPOE BAY, OR
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 30 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

15 April 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8351339
17 July 2025 DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8188803
4 March 2025 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8088716
5 June 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7929712
24 May 2023 DAPI Audit · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7700675
16 March 2023 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7652596
5 May 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7445398
6 May 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7188471
22 April 2021 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7180389
28 April 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6946159
29 April 2019 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6684287
12 March 2019 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6645541
30 April 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6433763
7 August 2017 Deficiency Check · Plan Review "T" Boat · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6265762
19 April 2017 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6133792
20 April 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5862459

Deficiency record · 8

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 May 2021 Resolved
EPIRB Battery Expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 7 May 2021
Resolution: New registered EPIRB installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 May 2021 Resolved
HRU unit for EPIRB expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 7 May 2021
Resolution: New HRU installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 May 2021 Resolved
No record of drills o/b vsl (master had copies at home due to lack of vessel service).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 7 May 2021
Resolution: Drill logs were placed back on the vsl and copies provided for review.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 March 2019 Resolved
Provide current FCC station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 22 March 2019
Resolution: FCC station license renewed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 March 2019 Resolved
Provide current FCC radio telephony safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2019
Resolved 22 March 2019
Resolution: New FCC safety cert issues.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 March 2019 Resolved
Troubleshoot override function on vessels fixed fire extinguishing system. Demonstrate proper operation to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2019
Resolved 18 March 2019
Resolution: Witnessed proper operation of override function on fixed system.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 23 October 2017 Resolved
Demonstrate proper operation of fixed fire extinguishing system in engine room. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2017
Resolved 6 February 2018
Resolution: Witnessed proper operation of fixed fire system and overide function.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 20 April 2016 Resolved
During operational testing, the Fireboy failed to shut down the engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2016
Resolved 22 April 2016

Casualty record · 1

13 July 2002Significant Marine Casualty · role: Sighted in Area · 1 dead · activity 1648950
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.