MAURY USCG vessel records
← All vessels

DEEPSTAR

DEEPSTAR is a 1999 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2016, most recently in April 2021, along with 16 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2021. Most recent: inspection, 12 April 2021.

Built
1999
Last inspected
12 April 2021
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF4059
501911
Flag
UNITED STATES
Maury page id
psix-501911

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)64.4 ft × 8.4 ft × 8.4 ft
Registered tonnagegross 30 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEEPSEA SUBMARINE TECH · SEATTLE · built 1999
Hull materialSteel
PropulsionElectric Motor
Hull shapeShip
Hull configurationMonohull
Hailing portSAIPAN, MP
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

12 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7173286
27 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7017839
23 May 2019 Hull Examination · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6691973
16 May 2018 Internal Structural Exam · Underwater Inspection in lieu of Drydock · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6416427
26 April 2017 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6134323
12 April 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6123369
16 May 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5878218
10 March 2016 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5831075

Deficiency record · 16

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 July 2020 No resolution recorded
Vessel was approved by COTP for "IN ACTIVE" status. In order to return to service, VSL must complete COI renewal inspection and dry dock examination. SEC GU MSIB 03-20 (CH-1).
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 May 2018 Resolved
Ring life buoy must be marked clearly legible letters with vessel name as required by 46CFR185.604. Re-stencil faded vessel name on ring life buoy.
Due 25 May 2018
Resolved 24 June 2019
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 16 May 2018 Resolved
Each life jacket must be marked in legible letters with vessel name as required by 46CFR185.604. Mark all life jacket on supporting vessel (CRYSTAL).
Due 24 May 2018
Resolved 24 June 2019
Lifesaving › Lifeboat Equipment › Food Ration
Issued 16 May 2018 Resolved
Found (08) expired food ration, manufactured by DATREX. Replace expired food ration.
Due 24 May 2018
Resolved 24 June 2019
Lifesaving › Visual Distress Signals (General) › Expired
Issued 16 May 2018 Resolved
Support vessel must have (03) red flares and (03) orange flares as required by 46CFR180.68. Replace red flares with expired dates.
Due 24 May 2018
Resolved 24 June 2019
Communications › Visual Communication › Red Warning Signal
Issued 16 May 2018 Resolved
CO2 monitor must be in serviceable conditions as required by NVIC 5-93. Repair inoperable CO2 monitor.
Due 24 May 2018
Resolved 24 June 2019
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2017 Resolved
Found inoperable bilge high water level sensor. Show proper operations of the bilge level alarm.
Due 12 April 2017
Resolved 12 April 2017
Lifesaving › Emergency Outfit › Flashlight
Issued 12 April 2017 Resolved
Found improper storage of portable emergency flash lights. Install portable light aft by entrance to machinery space and one forward by control station.
Due 12 April 2017
Resolved 12 April 2017
Communications › Alarms/Indicators › High Water Alarm
Issued 12 April 2017 Resolved
Found unmarked control switch for bile alarm system. Mark switch position for normal position and silence alarm position.
Due 12 April 2017
Resolved 12 April 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 March 2016 Resolved
All electrical equipments must be properly installed and be ready for inspection and test as required by 46 CFR 176.806. Vessel replaced the motorized breaker for the 248 volt batteries with manual breaker while waiting for ordered parts arrival. Install in-kind breaker and show to the attending MI the proper breaker operations.
Due 25 March 2016
Resolved 18 June 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 March 2016 Resolved
Vessel must have proper working navigation light that meet UL 1104 as required by 46 CFR 183.420. Found inoperable stern light. Repair stern light.
Due 25 March 2016
Resolved 11 March 2016
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 10 March 2016 Resolved
Dept gauge must be calibrated and functional as required by NVIC 5-93. Install original deep gauge and show proper operation to CG.
Due 25 March 2016
Resolved 17 March 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 March 2016 Resolved
Placard for lifejacket donning must be post in conspicuous place that is accessible and visible by the passenger as required by 46 CFR 185.516. Install life jacket donning placard.
Due 25 March 2016
Resolved 17 March 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 March 2016 Resolved
Vessel must have equipment to test detector for hydrogen gas & CO2 as required by NVIC 5-93. Provide testing equipment for detector test.
Due 25 July 2016
Resolved 15 March 2016
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 10 March 2016 Resolved
Inspection date on the FAA lifejackets (SWITLIK PARACHUTE CO)container is Jan 2015. Provide manufacture documentation verifying that inspection requirements met.
Due 25 March 2016
Resolved 15 March 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 10 March 2016 Resolved
Vessel operates within Sea Area A1 must upgrade to VHF-DSC radio as required by 47CFR80.905 & MSIB 15-15.
Due 13 June 2016
Resolved 18 May 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.