MAURY USCG vessel records Sign in
← All vessels

RAIN RIVER

RAIN RIVER is a 1979 offshore supply vessel. The Coast Guard has recorded 56 inspections since 1981, most recently in December 2008, along with 32 deficiencies.

Records from 1981 to 2008. Most recent: inspection, 23 December 2008.

Built
1979
Last inspected
23 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7942805 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBE5853
Flag
UNITED STATES
369530000 (licence lapsed)
Maury page id
psix-50192

Inspections, by type

…with no type recorded17
Years with a record 25 calendar years (1981–2008)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it243 - Regulatory (Subpart C or D), Net Ton
193 - Convention (Subpart B), Net Ton
381 - Regulatory (Subpart C or D), Gross Ton
643 - Convention (Subpart B), Gross Ton
786 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBE5853MMSI 369530000 · cancelled · compulsorily equipped · granted 20 January 2007, cancelled 25 February 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

23 December 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3384179
25 September 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073844
2 July 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2981241
11 June 2007 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2958091
16 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875007
25 September 2006 Cargo Tank Internal · COI Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2787167
24 August 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2758359
19 August 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2757677
16 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586316
8 December 2005 MTSA Verification · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2542436
27 July 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2442176
8 July 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2442124
7 October 2004 Re-Inspection · MTSA/ISPS Verification · Examination of Repairs · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2215941
17 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950242
25 September 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1913081
4 September 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1897439
10 December 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1716676
13 June 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1630325
5 March 2002 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1491230
14 September 2001 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1420589
2 July 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 13001
17 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808263
26 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116698
8 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120349
1 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783756
15 September 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779242
3 September 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380986
18 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776461
29 October 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853710
2 October 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459262
15 September 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363385
7 September 1995 Inclining Experiment · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374307
15 December 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436937
7 December 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159911
15 November 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1147064
15 October 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397968
28 February 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1309414
22 October 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 649797
16 May 1991 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906506
14 May 1991 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216744
27 February 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242530
7 March 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915212
2 March 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198809
12 May 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041603
10 May 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041503
8 March 1988 MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338735
27 February 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323777
11 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311905
9 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986305
9 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998763
25 February 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993513
27 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289821
26 February 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981403
25 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281937
29 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966842
1 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272008

Deficiency record · 32

Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 June 2007 Resolved
46CFR15.515(a) Vessel operated without full compliment of crew as required by COI.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel has full compliment of crew as required by COI.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 June 2007 Resolved
46CFR 15.805(a)(2) Failure to have licensed Master on inspected vessel.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel had licensed Master on vessel.
Construction/Loadline › Markings › Load Line Mark
Issued 11 June 2007 Resolved
46CFR42.07-50 Operation of vessel with loadline submerged.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel loadline not submerged.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 11 June 2007 Resolved
46CFR97.15-7(a) Failure to be in compliance with vessel's stability letter, vessel over loaded per required drafts while underway with cargo.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel was in compliance with stability letter.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 October 2006 Resolved
INSTALL BREAKER COVER IN ELECTRICAL BOX ON BRIDGE.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 12 October 2006
Resolution: COMPLETED
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 October 2006 Resolved
PROVIDE APPROVED ALCOHOL TESTING KIT AS PER 46 CFR PART 4.
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Communications › Radio Communications › EPIRB
Issued 12 October 2006 Resolved
RENEW EPIRB ANTENNA.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Fire Fighting › Fire Main › Valves
Issued 12 October 2006 Resolved
RENEW VALVE AND NOZZLE FORWARD FIRE STATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Construction/Loadline › Penetrations › Gasket
Issued 12 October 2006 Resolved
RENEW MAIN DECK GALLEY WTD WITH APPROVED GASKET.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Construction/Loadline › Markings
Issued 4 September 2003 Resolved
Draft marks illegible to read. Notice to correct issued verbally to Port Engineer. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 4 October 2003
Resolved 4 September 2003
Electrical › Lighting (emergency)
Issued 4 September 2003 Resolved
Emergency lighting not aligned to shine on egress routes. Item entered on CG-835. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper Installation
Due 4 October 2003
Resolved 12 September 2003
Resolution: Received written verification that light were realigned to focus on egress points.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 September 2003 Resolved
Starboard side MDE exhaust pipe cracked. Item entered on CG-835. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 4 October 2003
Resolved 22 September 2003
Resolution: Received written verification and receipt of welding repair work done by quality welding.8'' X 14" flex joint was installed.
Lifesaving › Lifebuoys
Issued 4 September 2003 Resolved
Lifering excessivly weathered, worn out. Item entered on CG-835.
Condition: Improper/Lack of Maintenance
Due 4 October 2003
Resolved 4 September 2003
Resolution: Received written verification that ring buoy was replaced.
Construction/Loadline › Structures
Issued 4 September 2003 Resolved
WTD to engineroom and foc'sel weather deck out of adjustment, not sealing properly to make a watertight fitting. Items entered on CG-835.
Condition: Improper/Lack of Maintenance
Due 4 October 2003
Resolved 7 September 2003
Resolution: Received written verification that dogs were properly adjusted to allow WTD to properly seal.
Navigation
Issued 2 October 1996 Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR IN FOLLOW UP MODE.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Navigation
Issued 2 October 1996 Resolved
PROVIDE CURRENT COPY OF TIDE/CURRENT TABLE, LIGHT LIST, COAST PILOT.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Accommodation/Occupational Safety
Issued 2 October 1996 Resolved
REPAIR/REPLACE WASTED STEP PORT SIDE LADDER, BOTTOM STEP.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996 Resolved
REPAINT DRAFT MARKS.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Engineering
Issued 2 October 1996 Resolved
REMOVE OR PROPERLY INSTALL SIGHT GLASS ON BOTH STBD/PORT FUEL DAY TANKS.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996 Resolved
RELABEL BALLAST AND BILGE MANIFOLD VALVES.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Electrical
Issued 2 October 1996 Resolved
PROVIDE PROPER VENTILATION FOR EMERG BATTERY IN WHEELHOUSE.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Engineering
Issued 7 September 1995 Resolved
INSERT HOLE IN STBD. FUEL DAY TANK AND PORT COFFERDAM ADJACENT TO PORT FUELDAY TANK.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Documentation
Issued 15 October 1993 Resolved
PROVIDE ON BOARD OR SUBMIT FOR APPROVAL VESSEL FIRE SAFETY PLAN.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Engineering
Issued 15 October 1993 Resolved
PROVIDE ON BOARD OR SUBMIT FOR APPROVAL TESTING PROCEDURES FOR ENGINEERING AUTOMATED CONTROL / MONITORING SYSTEM.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Unknown
Issued 10 May 1988 Resolved
SERVICE ANCHOR WINDLASS TO DETERMINE, IF ANY, DAMAGE TO HYDRALIC UNIT.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 10 May 1988 Resolved
MAKE PERMANENT REPAIR TO HULL IN WAY OF FRACTURE APPROXIMATELY 4" ABOVE MAIN DECK AT JUNCTURE OF SOFT NOSE AND HULL PLATE ON STARBOARD SIDE.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 10 May 1988 Resolved
REPLACE OR REPAIR PORT ANCHOR.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 9 April 1986 Resolved
PROVIDE AN APPROVED DRAWING FOR THE FIXED CO2 SYSTEM FOR THE SP5 CARGO TANKAS INSTALLED. APPROVAL IS TO BE BY MMT NOLA.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Unknown
Issued 27 March 1985 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL LEOPOLD THERIOT DN604486.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985 Resolved
PROVIDE SATISFACTORY TEST OF PORT MAIN ENGINE OVERSPEED TRIP, TO THE SATISFACTION OF A COAT GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 26 February 1985 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, LEOPOLD THERIOT, DN604486 AND ARE TO BE COMPLIED WITH BY 26MAR85.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Engineering
Issued 26 February 1985 Resolved
PROVIDE SATISFACTORY TEST OF PORT MAIN ENGINE OVERSPEED TRIP. THIS REQUIREMENT IS TO BE COMPLETED TO THE SATISFACTION OF A CG MARINE INSPECTOR ON OR BEFOR 26 MARCH 1985.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985

Ownership record