Records from 1981 to 2008. Most recent: inspection, 23 December 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 56
23 December 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3384179
25 September 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073844
2 July 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2981241
11 June 2007
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2958091
16 February 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875007
25 September 2006
Cargo Tank Internal · COI Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2787167
24 August 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2758359
19 August 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2757677
16 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586316
8 December 2005
MTSA Verification · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2542436
27 July 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2442176
8 July 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2442124
7 October 2004
Re-Inspection · MTSA/ISPS Verification · Examination of Repairs · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2215941
17 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950242
25 September 2003
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1913081
4 September 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1897439
10 December 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1716676
13 June 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1630325
5 March 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1491230
14 September 2001
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1420589
2 July 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 13001
17 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808263
26 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116698
8 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120349
1 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783756
15 September 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779242
3 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380986
18 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776461
29 October 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853710
2 October 1996
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459262
15 September 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363385
7 September 1995
Inclining Experiment · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374307
15 December 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436937
7 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159911
15 November 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1147064
15 October 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397968
28 February 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1309414
22 October 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 649797
16 May 1991
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906506
14 May 1991
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216744
27 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242530
7 March 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915212
2 March 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198809
12 May 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041603
10 May 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041503
8 March 1988
MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338735
27 February 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323777
11 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311905
9 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986305
9 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998763
25 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993513
27 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289821
26 February 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981403
25 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281937
29 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966842
1 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272008
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 June 2007
Resolved
46CFR15.515(a) Vessel operated without full compliment of crew as required by COI.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel has full compliment of crew as required by COI.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 June 2007
Resolved
46CFR 15.805(a)(2) Failure to have licensed Master on inspected vessel.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel had licensed Master on vessel.
Construction/Loadline › Markings › Load Line Mark
Issued 11 June 2007
Resolved
46CFR42.07-50 Operation of vessel with loadline submerged.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel loadline not submerged.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 11 June 2007
Resolved
46CFR97.15-7(a) Failure to be in compliance with vessel's stability letter, vessel over loaded per required drafts while underway with cargo.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 23 December 2008
Resolution: Vessel was in compliance with stability letter.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 October 2006
Resolved
INSTALL BREAKER COVER IN ELECTRICAL BOX ON BRIDGE.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 12 October 2006
Resolution: COMPLETED
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 October 2006
Resolved
PROVIDE APPROVED ALCOHOL TESTING KIT AS PER 46 CFR PART 4.
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Communications › Radio Communications › EPIRB
Issued 12 October 2006
Resolved
RENEW EPIRB ANTENNA.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Fire Fighting › Fire Main › Valves
Issued 12 October 2006
Resolved
RENEW VALVE AND NOZZLE FORWARD FIRE STATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Construction/Loadline › Penetrations › Gasket
Issued 12 October 2006
Resolved
RENEW MAIN DECK GALLEY WTD WITH APPROVED GASKET.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2006
Resolved 13 October 2006
Resolution: COMPLETED
Construction/Loadline › Markings
Issued 4 September 2003
Resolved
Draft marks illegible to read. Notice to correct issued verbally to Port Engineer. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 4 October 2003
Resolved 4 September 2003
Electrical › Lighting (emergency)
Issued 4 September 2003
Resolved
Emergency lighting not aligned to shine on egress routes. Item entered on CG-835. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper Installation
Due 4 October 2003
Resolved 12 September 2003
Resolution: Received written verification that light were realigned to focus on egress points.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 September 2003
Resolved
Starboard side MDE exhaust pipe cracked. Item entered on CG-835. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 4 October 2003
Resolved 22 September 2003
Resolution: Received written verification and receipt of welding repair work done by quality welding.8'' X 14" flex joint was installed.
Lifesaving › Lifebuoys
Issued 4 September 2003
Resolved
Lifering excessivly weathered, worn out. Item entered on CG-835.
Condition: Improper/Lack of Maintenance
Due 4 October 2003
Resolved 4 September 2003
Resolution: Received written verification that ring buoy was replaced.
Construction/Loadline › Structures
Issued 4 September 2003
Resolved
WTD to engineroom and foc'sel weather deck out of adjustment, not sealing properly to make a watertight fitting. Items entered on CG-835.
Condition: Improper/Lack of Maintenance
Due 4 October 2003
Resolved 7 September 2003
Resolution: Received written verification that dogs were properly adjusted to allow WTD to properly seal.
Navigation
Issued 2 October 1996
Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR IN FOLLOW UP MODE.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Navigation
Issued 2 October 1996
Resolved
PROVIDE CURRENT COPY OF TIDE/CURRENT TABLE, LIGHT LIST, COAST PILOT.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Accommodation/Occupational Safety
Issued 2 October 1996
Resolved
REPAIR/REPLACE WASTED STEP PORT SIDE LADDER, BOTTOM STEP.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996
Resolved
REPAINT DRAFT MARKS.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Engineering
Issued 2 October 1996
Resolved
REMOVE OR PROPERLY INSTALL SIGHT GLASS ON BOTH STBD/PORT FUEL DAY TANKS.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996
Resolved
RELABEL BALLAST AND BILGE MANIFOLD VALVES.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Electrical
Issued 2 October 1996
Resolved
PROVIDE PROPER VENTILATION FOR EMERG BATTERY IN WHEELHOUSE.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Engineering
Issued 7 September 1995
Resolved
INSERT HOLE IN STBD. FUEL DAY TANK AND PORT COFFERDAM ADJACENT TO PORT FUELDAY TANK.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Documentation
Issued 15 October 1993
Resolved
PROVIDE ON BOARD OR SUBMIT FOR APPROVAL VESSEL FIRE SAFETY PLAN.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Engineering
Issued 15 October 1993
Resolved
PROVIDE ON BOARD OR SUBMIT FOR APPROVAL TESTING PROCEDURES FOR ENGINEERING AUTOMATED CONTROL / MONITORING SYSTEM.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Unknown
Issued 10 May 1988
Resolved
SERVICE ANCHOR WINDLASS TO DETERMINE, IF ANY, DAMAGE TO HYDRALIC UNIT.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 10 May 1988
Resolved
MAKE PERMANENT REPAIR TO HULL IN WAY OF FRACTURE APPROXIMATELY 4" ABOVE MAIN DECK AT JUNCTURE OF SOFT NOSE AND HULL PLATE ON STARBOARD SIDE.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 10 May 1988
Resolved
REPLACE OR REPAIR PORT ANCHOR.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 9 April 1986
Resolved
PROVIDE AN APPROVED DRAWING FOR THE FIXED CO2 SYSTEM FOR THE SP5 CARGO TANKAS INSTALLED. APPROVAL IS TO BE BY MMT NOLA.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Unknown
Issued 27 March 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL LEOPOLD THERIOT DN604486.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE SATISFACTORY TEST OF PORT MAIN ENGINE OVERSPEED TRIP, TO THE SATISFACTION OF A COAT GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 26 February 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, LEOPOLD THERIOT, DN604486 AND ARE TO BE COMPLIED WITH BY 26MAR85.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Engineering
Issued 26 February 1985
Resolved
PROVIDE SATISFACTORY TEST OF PORT MAIN ENGINE OVERSPEED TRIP. THIS REQUIREMENT IS TO BE COMPLETED TO THE SATISFACTION OF A CG MARINE INSPECTOR ON OR BEFOR 26 MARCH 1985.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985