STEIN

STEIN is a 1999 towing vessel. The Coast Guard has recorded 5 inspections since 2008, most recently in June 2026, along with 4 deficiencies.

Records from 2008 to 2026. Most recent: inspection, 23 June 2026.

Built
1999
Last inspected
23 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 23 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2008–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

501993
Flag
UNITED STATES
Maury page id
psix-501993

Documentation record

Registered dimensions (L × B × D)25.9 ft × 10.0 ft × 3.6 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINLAND INDUSTRIES INC · ORANGE TX, UNITED STATES · built 1999
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portCLAYTON, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 5

23 June 2026 Deficiency Check
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8412083
29 November 2022 Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 7601652
20 October 2020 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7086384
16 June 2011 DAPI Audit · Uninspected Other · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4111109
3 December 2008 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3378816

Deficiency record · 4

Fire Fighting › Remote Fuel Shutoff › General
Issued 16 June 2011 Resolved
Provide remote fuel shut off valve outside E/R space.
Condition: Improper Installation
Due 23 June 2011
Resolved 13 September 2011
Resolution: Instalation sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 June 2011 Resolved
Privide chaffing gear on all wiring runs in teh E/R space.
Condition: Improper Installation
Due 23 June 2011
Resolved 13 September 2011
Resolution: Installation sat.
Engineering › Fuel Oil Service System › Hose
Issued 16 June 2011 Resolved
Provide supports for fule line in E/R space.
Condition: Improper Installation
Due 23 June 2011
Resolved 13 September 2011
Resolution: Installation sat.
Deck/Cargo › Towing › Towline
Issued 16 June 2011 Resolved
Replace frayed/worn towline cabels port and starboard side.
Condition: Improper/Lack of Maintenance
Due 23 June 2011
Resolved 13 September 2011
Resolution: Installation sat with new mat.

Ownership record