MAURY USCG vessel records Sign in
← All vessels

PACIFIC VOYAGER

PACIFIC VOYAGER is a 1979 passenger vessel (inspected). The Coast Guard has recorded 111 inspections since 1984, most recently in March 2026, along with 160 deficiencies and 2 casualty investigations between 2006 and 2016.

Records from 1984 to 2026. Most recent: inspection, 30 March 2026.

Built
1979
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
366838650
Maury page id
psix-50200

Inspections, by type

…with no type recorded25
Years with a record 39 calendar years (1984–2026)
The 111 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.6 ft × 18.9 ft × 7.6 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH MARINE INC · TACOMA, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDFWMMSI 366838650 · active · compulsorily equipped · granted 9 February 2022, expires 12 February 2032
WCQ3117MMSI not assigned · expired · compulsorily equipped · granted 8 December 1999, cancelled 7 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 111

30 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8334317
29 January 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8296037
30 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8126359
25 April 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7901634
3 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889533
4 April 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662875
4 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7663569
14 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7577233
26 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7438380
9 March 2022 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7408713
27 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7183763
7 May 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6949731
11 March 2020 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6924565
12 February 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6907979
27 November 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6863694
9 May 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6680226
9 May 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6410446
15 March 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372331
16 May 2017 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6141378
10 July 2016 Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5939337
9 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5938624
2 May 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5867238
19 June 2014 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4918944
6 May 2014 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4851617
2 May 2012 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4300431
10 November 2010 Plan Review "T" Boat · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3888828
21 January 2010 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3715916
19 December 2008 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3372068
14 April 2008 Deficiency Check · Plan Review "T" Boat · Simplified Stability Test · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3186312
19 June 2007 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2945410
12 July 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2724533
6 January 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2560355
22 March 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2277243
14 December 2004 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2488636
24 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1937574
25 March 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1762351
18 November 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1706103
1 October 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1682841
24 January 2002 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1481081
28 December 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474289
24 May 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1405197
2 March 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362010
15 February 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362039
30 January 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1444462
25 January 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1056957
17 October 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373192
12 May 2000 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1049680
7 January 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 814447
22 October 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437625
30 September 1999 Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1401092
3 June 1999 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 60522
7 May 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 794555
29 April 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413526
18 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 789923
19 February 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 788921
3 February 1999 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369024
18 December 1998 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 807362
24 November 1998 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 806270
22 October 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 803962
21 October 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802409
1 October 1998 Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386337
3 September 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395017
20 August 1998 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 180752
10 November 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1120226
16 October 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1414880
4 August 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 784190
20 May 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1105281
20 March 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1443838
1 October 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385827
9 August 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 98537
2 November 1995 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396424
16 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 81369
8 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 837760
7 December 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840358
27 September 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 867094
27 July 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374112
19 January 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1358281
28 October 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1135750
30 September 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846114
14 September 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144666
2 August 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848809
1 August 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2507
16 November 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1133528
16 October 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830664
23 September 1992 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938512
4 September 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246958
17 October 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246525
25 March 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 997380
24 October 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 909150
17 October 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931966
11 October 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1222071
24 August 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237227
23 July 1990 Examination of Repairs · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1213434
6 February 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900373
16 January 1990 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900372
14 June 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1208946
17 March 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1208457
6 January 1989 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1348226
7 June 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1199307
24 May 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195145
10 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1029481
8 June 1987 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1335245
2 June 1987 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1027463
5 May 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1018649
12 September 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1308874
22 May 1986 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1304575
19 December 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1299340
22 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1291609
16 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 981840
11 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284025
10 October 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 975380

Deficiency record · 160

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 30 March 2026 Resolved
Master missing medical certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 11 May 2026
Resolution: Master completed medical card requirements and is awaiting hard copy in mail.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 March 2026 Resolved
No documentation of an active Drug and Alcohol Program on board.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: Vessel provided proof of active DAPI program to SSD inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 March 2026 Resolved
Certificate of Documentation expired and operator unable to renew due to DHS government funding lapse.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2026
Resolved 11 May 2026
Resolution: Owner purchased new certificate of documentation and is awaiting hard copy in mail.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 March 2026 Resolved
None of the FCC licenses on board.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: Vessel provided current FCC documentation to SSD inspectors.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 March 2026 Resolved
No light on magnetic compass
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 2 April 2026
Resolution: SSD inspector verified compass light is now operational.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 March 2026 Resolved
Missing monthly EPIRB testing recorded in ship's log.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 2 April 2026
Resolution: SSD inspector verified monthly EPIRB test conducted and recorded in log book.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 March 2026 Resolved
Navigation lights inoperable
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified navigation lights are now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 March 2026 Resolved
Flares expire in 2 days. Replace before getting u/w for scheduled trip in 4 days.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: Marine inspector verified vessel purchased and carries current distress flares.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 March 2026 Resolved
Hydrostatic release for inflatable life raft expired one year ago. According 46 CFR 185.70 hydrostatic releases must be marked with the expiration date of two years after the date on which the unit is installed. Hydrostatic release was marked with expiration date of 3/2025.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified hydrostatic release for inflatable life raft now current.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 March 2026 Resolved
Fire detection system not integrated.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified fire detection system integration is now operational.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 March 2026 Resolved
Fuel shutoff valve inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified fuel cutoff valve is now operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 March 2026 Resolved
Support for electrical wiring in engine room missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 2 April 2026
Resolution: SSD inspector verified support for electrical wiring is now installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 April 2025 Resolved
Vessel was missing the FCC documents including the operators permit, Station License and Safety Certificate. 47 CFR Part 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2025 Resolved
Vessels ring buoy line was no longer servicable. Replace line. 46CFR180.70
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 April 2025 Resolved
Vessels hydrostatic release was not arranged correctly for the liferaft. Connect the hydrostatic release to the painter line.46CFR180.130
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 April 2025 Resolved
Vessel was missing gaurds on the mains belts. Reinstall guards. 46CFR185.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2025 Resolved
A positive shutoff valve is required to be installed at the hull penetration for submersible electrical bilge pumps. 46CFR182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2022 Resolved
Multiple twist-type connectors found facilitating a conductor splice. Facilitate splice with pressure type connector or other approved method IAW 46CFR 183.340(g).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 13 May 2022
Resolution: Installed new junction boxes to facilitate wire splices.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021 Resolved
REPLACE 2 OARS FOR LIFE FLOAT WITH 4FT LONG AND BUOYANT OARS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 April 2021 Resolved
REPLACE THE BROKEN VALVE HANDLE FOR THE FIRE HYDRANT
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
INSTALL BLANKS ON ENGINE ROOM DISTRUBUTION PANELS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2021 Resolved
REPLACE PLASTIC GARBAGE BINS WITH METAL
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 April 2021 Resolved
REPLACE BATTERY FOR 01 LIFE FLOAT WATERLIGHT
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2021 Resolved
LOWER GALLEY EXTINGUISHER BRACKET TO ENABLE REMOVAL IN AN EMERGENCY
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 May 2020 Resolved
Provide DSC capability to VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2020
Resolution: Picture received via e-mail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2020 Resolved
Mount hydraulic line in steering space off of steering ram.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2020
Resolution: Hydraulic line moved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 27 February 2020
Resolved 28 May 2020
Resolution: 1-line diagram verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. 1) Replace damaged outlet cover in crew cabin. 2) Place single red wire run through passenger cabins in protective covering (conduit). 3) Provide specification sheet for power cables used on FW pump, water heater and booster pump. Cabling must be listed as UL Boat, UL Marine or meet the following standards: NFPA 70 Section 310-13, IEEE 1580, UL 1309, IEC 60092-353, NPFC MIL-C-24643A or NPFC MIL-C-24640A. Replace cable if standards are not met.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2019
Resolved 12 February 2020
Resolution: Pictures received via e-mail.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 17 April 2008 Resolved
Repair/replace generator cable where exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 12 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 April 2008 Resolved
Change forward bilge alarm (light & audible) connection to be able to activate by itself (presently works, but is tied into other alarm indicators).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 19 May 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 June 2007 Resolved
Provide captive chain for watertight hatch on lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 20 June 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 June 2007 Resolved
Replace retroreflective tape on top lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 20 June 2007
Lifesaving › Lifefloat › Platform
Issued 19 June 2007 Resolved
Repair/replace top lifefloat basket floor frame (weld cracked).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 20 June 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 June 2007 Resolved
Provide up-to-date chart & publications (Chart, CG Light List, Tidal Current Tables, & NAVRULS) for areas vessel transits--excerpts are acceptable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 20 June 2007
Communications › Radio Communications › Satellite Communications Capability
Issued 19 June 2007 Resolved
Provide NAVTEX & DSC-capable radio IAW 47 CFR80.905. Vessel restricted to nmt 100 miles from shore until corrected.
Action required: 705 - Other - as specified
Due 19 June 2007
Resolved 17 April 2008
Resolution: Owner elected to have COI amended to nmt 100 nm until NAVTEX & DSC radio obtained.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 January 2006 Resolved
Repair/replace emergency light for the passenger spaces, and install a second emergency light to illuminate the emergency exit in the forward passenger bunkroom.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 17 January 2006
Resolution: Replaced broken emergency light and installed second emergency light in the forward passenger bunkroom.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 December 2004 Resolved
Provide current corrected U.S. Coast Pilot for areas transitted IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 14 December 2004
Resolution: Received faxed receipt for Coast Pilot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 December 2004 Resolved
Provide current corrected CG Light List for areas to be transitted IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 14 December 2004
Resolution: Received faxed receipt for publication.
Navigation › Piloting/Steering › Marine Charts
Issued 14 December 2004 Resolved
Provide current corrected chart(s) for areas to be transitted IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 14 December 2004
Resolution: Received faxed receipt for charts.
Fire Fighting › Grease Extraction Hood › General
Issued 14 December 2004 Resolved
Found excessive grease on extraction hood grease traps. Clean galley grease traps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 30 December 2004
Resolution: Received faxed copy of delivery receipt for (3) grease filters.
Lifesaving › Hand Flares › Marking
Issued 14 December 2004 Resolved
Mark distress signal (flare) container IAW 46CFR185.614.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 14 December 2004
Fire Fighting › Fixed Fire Detection System
Issued 28 October 2003 Resolved
Smoke detector in forward berthing space failed to sound, remove and renew. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Unknown
Due 10 December 2003
Resolved 4 December 2003
Communications › Radio Communications
Issued 28 October 2003 Resolved
Provide proof of current EPIRB battery, hydrostatic release, and regisration. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2003
Engineering › Freshwater Generation System
Issued 28 October 2003 Resolved
Potable water heater was not secured in stbd side engine room. LEGACY COMPONENT DESC: Heating Tube
Due 10 December 2003
Resolved 4 December 2003
Engineering › Fuel Oil Service System
Issued 28 October 2003 Resolved
Make all emergency cutout valves opperable LEGACY COMPONENT DESC: Valve, Control
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 October 2002 Resolved
Remove old vessel names from PFDs LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Due 1 November 2002
Resolved 18 November 2002
Electrical › Lighting (service)
Issued 1 October 2002 Resolved
Install tube covers over flourescent bulbs in FWD compartment. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 18 November 2002
Engineering › Steering Gear System
Issued 1 October 2002 Resolved
Repair pivot rod in connection rod. LEGACY COMPONENT DESC: Linkage
Condition: Unknown
Due 1 November 2002
Resolved 18 November 2002
Electrical › Electrical Distribution System (service)
Issued 1 October 2002 Resolved
Install dripshield over switchboard LEGACY COMPONENT DESC: Switchboard
Condition: Improper Installation
Due 1 November 2002
Resolved 18 November 2002
Electrical › Electrical Distribution System (service)
Issued 1 October 2002 Resolved
Lift electrical cables in Psgr bilge above water level and attach to deck beams. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 1 November 2002
Resolved 18 November 2002
Electrical › Electrical Distribution System (service)
Issued 1 October 2002 Resolved
Install metal cable clamps in ER for overhead cable runs. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 1 November 2002
Resolved 1 October 2002
Fire Fighting › Ventilation Systems
Issued 1 October 2002 Resolved
Install 30X30 mesh in MSD vent. LEGACY COMPONENT DESC: Ducts
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 18 November 2002
Operations/Management › Navigation Safety
Issued 1 October 2002 Resolved
Replace cracked bridge window. LEGACY COMPONENT DESC: Navigation Underway, General
Condition: Unknown
Due 1 November 2002
Resolved 18 November 2002
Accommodation/Occupational Safety › Ventilation
Issued 28 December 2001 Resolved
Clean vents for stove exhaust in galley. LEGACY COMPONENT DESC: Galley Stove Vent
Condition: Improper/Lack of Maintenance
Due 20 January 2002
Resolved 23 January 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 28 December 2001 Resolved
Clean excessive grease from under stove. LEGACY COMPONENT DESC: Grease under stove
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Documentation › Logs/Records
Issued 20 December 2001 Resolved
Provide waste management program. LEGACY COMPONENT DESC: Garbage Recordkeeping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Documentation › Logs/Records
Issued 20 December 2001 Resolved
Provide log for crew training/epirb testing. LEGACY COMPONENT DESC: Logbook (official)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Fire Fighting › Fixed Fire Detection System
Issued 20 December 2001 Resolved
Provide smoke detectors in berthing compartment both fore and aft. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Fire Fighting › Means of Escape
Issued 20 December 2001 Resolved
Mark topside emergency escape hatch "Emergency Exit Do Not Block". LEGACY COMPONENT DESC: Escape Route Signs
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Deck/Cargo › Holds/Tanks
Issued 20 December 2001 Resolved
Provide captive chains for all deck hatches. LEGACY COMPONENT DESC: Hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Electrical › Electric Generation Source (emergency)
Issued 20 December 2001 Resolved
Provide support/mounting bracket for electricl wire in fwd bilge bunk room. LEGACY COMPONENT DESC: Power Requirement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 20 December 2001
Engineering › Generator (propulsion-electric)
Issued 20 December 2001 Resolved
Clean excess oil from generator screen. LEGACY COMPONENT DESC: Dirty screen
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 20 December 2001 Resolved
Clean excess oil from under blowers on both port and starboard engines. LEGACY COMPONENT DESC: Excess oil
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Engineering › Bilge Water Management System
Issued 20 December 2001 Resolved
Provide adequate length suction hose for hand held bilge pump. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2002
Resolved 23 January 2002
Engineering › Bilge Water Management System
Issued 20 December 2001 Resolved
Provide both audible and visual high level bilge alarms at the operating station. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2002
Resolved 23 January 2002
Engineering
Issued 2 March 2001 Resolved
PROPERLY MOUNT LUBE OIL PRESSURE AND JACKET WATER TEMPERATURE GAUGES FOR GENERATOR.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 2 March 2001 Resolved
REMOVE OBSTRUCTIONS RESTRICTING ACCESS TO SKIN VALVE FOR STARBOARD MAIN ENGINE COOLING WATER SUCTION.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 2 March 2001 Resolved
MAKE PVC PIPING PENETRATINS THROUGH FORWARD AND AFTER ENGINE ROOM BULKHEADSIN ACCORDANCE WITH 46 CFR 182.720.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 2 March 2001 Resolved
MAKE FORWARD AND AFTER ENGINE ROOM BULKHEADS WATERTIGHT.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 17 October 2000 Resolved
RENEW WEAKLINK SERVICING (2) EIGHT MAN LIFEFLOATS.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Accommodation/Occupational Safety
Issued 17 October 2000 Resolved
INSTALL GREASE EXTRACTION HOOD AS REQUIRED BY 46 CFR 181.425.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Electrical
Issued 17 October 2000 Resolved
INSTALL EMERGENCY LIGHTING IN ACCOMMODATION SPACE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Lifesaving
Issued 17 October 2000 Resolved
RENEW 406 EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Engineering
Issued 17 October 2000 Resolved
REPAIR AS NEW F/O STOP VALVE ON PORT F/O TANK.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Engineering
Issued 17 October 2000 Resolved
RENEW GENERATOR EXHAUST HOSE USING APPROVED EXHAUST HOSE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Electrical
Issued 17 October 2000 Resolved
RENEW ALL "SO, SJO, STO, SOW WIRING IN VESSEL'S AC ELECTRICAL SYSTEM USING "APPROVED" MARINE GRADE WIRING. THIS REQUIREMENT IS DUE AT THE VESSEL'S NEXT HULL EXAM.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Construction/Loadline
Issued 22 October 1999 Resolved
Vessel is required to meet subdivision requirements of 46 CFR 179.212 priorto 30 April 2000 or be limited to no more than 49 passengers.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 30 September 1999 Resolved
Post operating instructions for installed fixed fire extinguishing system per 46 CFR 185.612.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Documentation
Issued 30 September 1999 Resolved
Add 406 EPIRB to FCC station license.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Fire Fighting
Issued 29 April 1999 Resolved
POST SIMPLE INSTRUCTIONS FOR ENGINE ROOM FIXED GAS FIRE EXTINGUISHING SYSTEM PER 46 CFR 185.612
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Fire Fighting
Issued 29 April 1999 Resolved
INSTALL VENT CLOSURES FOR VENTILATION SERVICING ENGINE ROOM PER 46 CFR 182.465
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 29 April 1999 Resolved
CONDUCT SIMPLIFIED SUBDIVISION CALCULATIONS TO VERIFY CURRENT PASSENGER COUNT PER 46 CFR 171.040 ON OLD T REGULATIONS
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 3 February 1999 Resolved
Conduct simplified measurement for subdivision on forms provide and submit to the MSD for review
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 3 February 1999 Resolved
Install bilge high level alarms as required by 46cfr 182.530.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Lifesaving
Issued 3 February 1999 Resolved
Repair as new or remove fish hold refrigeration system
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Electrical
Issued 21 October 1998 Resolved
REMOVE ELECTRICAL TWIST CONNECTIONS IN WAY OF FWD COMPARTMENT BILGLE PUMP
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 1 October 1998 Resolved
INSTALL BILGE STRAINER IN BILGE SUCTION IN WAY OF FORE PEAK
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Accommodation/Occupational Safety
Issued 1 October 1998 Resolved
POST LABEL EMERGENCY EXIT IN FWD ACCOMODATION
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Electrical
Issued 1 October 1998 Resolved
REMOVE UNUSED WIRING IN WAY OF FWD COMPT BILGE
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Lifesaving
Issued 1 October 1998 Resolved
CORRECT LIFEJACKET MARKINGS FOR CHILD PFD'S TO REFLECT CORRECT NUMBER
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Lifesaving
Issued 1 October 1998 Resolved
INSTALL RETROREFLECTIVE TAPE ON LIFERING BUOYS
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Engineering
Issued 1 October 1998 Resolved
RENEW F/O VENT FLAME SCREENS WITH CORRECT SIZE MESH SCREEN
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Construction/Loadline
Issued 1 October 1998 Resolved
REPAIR AS NEW OVBD CONNECTION TO BAIT TANK STBD SIDE
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Navigation
Issued 1 October 1998 Resolved
UPDATE CHARTS WITH LOCAL NTMS AND HAVE ON BOARD CURRENT COPIES OF LIGHTLIST, COAST PILOT ETC...
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Documentation
Issued 1 October 1998 Resolved
LOG MONTHLY TEST OF EPIRB
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Engineering
Issued 1 October 1998 Resolved
REPAIR AS NEW STBD F/O TANK REMOTE EMERGENCY STOP
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Accommodation/Occupational Safety
Issued 3 September 1998 Resolved
SUBMIT PROPOSAL TO CORRECT SEWAGE PIPING IN WAY OF MSD HOLDING TANK.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Documentation
Issued 16 October 1997 Resolved
Provide proof of 98 sticker for documentation.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 16 October 1997 Resolved
Engine room, fix both main engine exhaust leaks.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 16 October 1997 Resolved
Fuel tank valve has a small drip, repair or replace valve.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Documentation
Issued 16 October 1997 Resolved
Provide a waste management plan.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Documentation
Issued 16 October 1997 Resolved
Provide proof of paying user fee.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Documentation
Issued 16 October 1997 Resolved
Start and maintain a waste disposal log.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
Repair or replace the water light for the aft most lifefloat.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 1 October 1996 Resolved
PROVIDE A FIRST AID KIT APPROVED IAW 46 CFR 160.041 AS PER 46CFR 184.710.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Navigation
Issued 1 October 1996 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD IAW 46 CFR 184.506.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Lifesaving
Issued 1 October 1996 Resolved
STOW LIFE RING BUOY WITH LIGHT CLOSE TO WHEELHOUSE.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Lifesaving
Issued 1 October 1996 Resolved
PROVIDE GUARD IN WAY OF SINGLE SIDE BAND ANTENNA JUNCTION BOX LOCATED IN WHEELHOUSE.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Lifesaving
Issued 2 November 1995 Resolved
Install adequate means of protection (Guards) for both main diesel engine drive shaft couplings.
Condition: Unknown
Due 4 November 1995
Resolved 3 January 1996
Lifesaving
Issued 2 November 1995 Resolved
Repair broken step at engine room entrance.
Condition: Unknown
Due 4 November 1995
Resolved 3 January 1996
Navigation
Issued 27 September 1994 Resolved
UPDATE CHARTS AND PUBLICATIONS
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Unknown
Issued 27 September 1994 Resolved
PROPERLY MOUNT BAIT TANK PUMP.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Documentation
Issued 30 September 1993 Resolved
PROVIDE PROOF OF CURRENT MARINE RADIO OPERATORS LICENSE.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Fire Fighting
Issued 30 September 1993 Resolved
PROVE OPERATION OF RE-INSTALLED STARBOARD SIDE FIRE/BAIT TANK PUMP.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Lifesaving
Issued 30 September 1993 Resolved
PROVIDE WATERLIGHT FOR 8 MAN LIFEFLOAT. REDUCE PASSENGERS TO 41 ON OCEAN ROUTE.
Condition: Unknown
Due 15 October 1993
Resolved 13 October 1993
Engineering
Issued 30 September 1993 Resolved
PROVIDE VENTILATION DUCT EXTENDING FROM OVERHEAD TO BILGE IN ENGINEROOM.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Construction/Loadline
Issued 2 August 1993 Resolved
PRIOR TO CARRYING PASSENGERS; PROVIDE INFORMATION TO MSO S.F. DETAILING THE CAUSE OF THE CASUALTY OCCURRING 01AUG93. ALSO SUBMIT REPAIR PROPOSALS & COMPLETE ALL NECESSARY ENGINE/HULL REPAIRS, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1993
Resolved 19 October 1993
Electrical
Issued 23 September 1992 Resolved
PROPERLY SECURE/REMOVE DEAD END ELECTRICAL WIRES IN STEERING COMPARTMENT.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Construction/Loadline
Issued 23 September 1992 Resolved
PROPERLY BRACE LONGITUDINAL FRAMING FWD & AFT OF BAIT TANKS ON OVERHEAD IN STEERING COMPARTMENT.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Construction/Loadline
Issued 23 September 1992 Resolved
TREAT/REPLACE FURRED FRAMING AND DECKING IN E/R OVERHEAD.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Engineering
Issued 23 September 1992 Resolved
REPLACE ALL SHAFT STRUT AND STERN TUBE BEARINGS.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Construction/Loadline
Issued 23 September 1992 Resolved
REPAIR DETERIORATED COATING ON STBD SIDE SHELL.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Documentation
Issued 4 September 1992 Resolved
PROVIDE MASTER'S LICENSE.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Engineering
Issued 4 September 1992 Resolved
REPAIR S/W LEAK AT ELBOW ENTRY TO EXHAUST.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Construction/Loadline
Issued 4 September 1992 Resolved
INSTALL HOSE CLAMP ON PORT MAIN S/W SUCTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Lifesaving
Issued 4 September 1992 Resolved
PROVIDE VSL WITH 6 ORANGE SMOKE FLARES.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Engineering
Issued 4 September 1992 Resolved
REPLACE LEAKING HYDRAULIC OIL HOSE FROM PORT MAIN ENGINE.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Documentation
Issued 4 September 1992 Resolved
PROVIDE VESSEL DOCUMENT.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Construction/Loadline
Issued 4 September 1992 Resolved
PROVE OPS OF HAND BILGE & FIRE PUMP.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Electrical
Issued 4 September 1992 Resolved
MAKE WIRING REPAIRS IN FWD COMPARTMENT BELOW BRIDGE - 3 COVERS AND PROPER CONNECTION AT VENT FAN.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Electrical
Issued 4 September 1992 Resolved
REPAIR WIRING IN E/R HOT WATER HEATER AND WIRE TO STBD BATTERY BOX._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Electrical
Issued 4 September 1992 Resolved
CONNECT BONDING THROUGHOUT VESSEL.
Condition: Unknown
Due 14 October 1992
Resolved 18 November 1992
Engineering
Issued 4 September 1992 Resolved
INSTALL PROPER ENGINE STOPS BOTH MAINS.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Accommodation/Occupational Safety
Issued 4 September 1992 Resolved
REPAIR MSD PIPE LEAK PORT SIDE.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Construction/Loadline
Issued 4 September 1992 Resolved
INSTALL CHECK VALVES ON ALL BILGE SUCTIONS.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Construction/Loadline
Issued 4 September 1992 Resolved
INSTALL VALVE HANDLES ON BILGE MAINFOLD.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Lifesaving
Issued 4 September 1992 Resolved
PROVIDE 6 ADULT AND 6 CHILD SIZE PFDs WITH LIGHTS. VESSEL IS RESTRICTED TO20 MILES COASTWISE AND NO MORE THAN 40 PASSENGERS UNTIL CLEARED.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Construction/Loadline
Issued 4 September 1992 Resolved
MAKE PERMANENT REPAORS TO BUNK ROOM SUCTION AT MAINFOLD.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Engineering
Issued 4 September 1992 Resolved
REPAIR OVBD PIPE AND THROUGH HULL IN AFT STRG STBD SIDE. PASSENGERS SHALL NOT BE CARRIED UNTIL ITEM COMPLETE.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Engineering
Issued 4 September 1992 Resolved
REPAIR EXHAUST BRACKETS IN AFT STRG.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Engineering
Issued 4 September 1992 Resolved
REPLACE HYDRAULIC LINE BRACKETS IN AFT STRG.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Documentation
Issued 4 September 1992 Resolved
PROVIDE VESSEL WITH COMPASS DEVIATION CARD.
Condition: Unknown
Due 14 October 1992
Resolved 18 November 1992
Navigation
Issued 4 September 1992 Resolved
REPAIR BRIDGE GAUGES AS FOLLOWS: a) PORT MAIN J/W TEMP; b) PORT MAIN OIL PSI; c) GENERATOR JACKET WATER TEMP.
Condition: Unknown
Due 14 October 1992
Resolved 18 November 1992
Electrical
Issued 4 September 1992 Resolved
INSTALL BLANK IN ELECTRIC PANEL ON BRIDGE.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Engineering
Issued 4 September 1992 Resolved
CLEAN AND REPLACE AS NECESSARY F/O VENT PIPING (1/2") BOTH TANKS.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Electrical
Issued 4 September 1992 Resolved
REBUILD BATTERY BOXES.
Condition: Unknown
Due 14 October 1992
Resolved 18 November 1992
Electrical
Issued 4 September 1992 Resolved
REPAIR LOOSE WIRE STBD BILGE AFT STRG.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Lifesaving
Issued 4 September 1992 Resolved
REPAIR OR REPLACE 15 MAN LIFEFLOAT.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Engineering
Issued 4 September 1992 Resolved
PROVE OPERATION OF PORT EMERGENCY F/O SHUT OFF.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Documentation
Issued 24 August 1990 Resolved
PROVIDE FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Accommodation/Occupational Safety
Issued 24 August 1990 Resolved
PROVIDE MEANS TO LOCK SEWAGE HOLDING TANK OVBD DISCHARGE VALVE.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Construction/Loadline
Issued 24 August 1990 Resolved
PROVIDE KEEPER CHAINS FOR ALL DECK HATCHES.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 August 1990 Resolved
PROVIDE BLOCKING FOR BATTERIES.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 May 1988 Resolved
REPAIR ELECTRICAL WIRING SPLICES IN ENGINEROOM AND BEHIND WHEEL HOUSE CONTROL CONSOLE WITH METAL CRIMP CONNECTORS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988 Resolved
REPLACE WASTED LINES ON LIFE RING BUOY.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988 Resolved
REPLACE WASTED MORSE CABLE ON EMERGENCY FUEL OIL SHUT OFF AND TEST PROPER OPERATION OF EMERGENCY FUEL OIL SHUT OFF.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988 Resolved
PROVIDE NAVIGATION RULES BOOK AND HAVE IT AVAILABLE AT ALL TIMES FOR OPERATORS IN THE WHEELHOUSE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988 Resolved
INSTALL/MOVE EXISTING STERN LIGHT TO CENTER OF STERN TRANSOME.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988 Resolved
INSTALL PROTECTIVE GUARDS TO PORT AND STARBOARD MAIN PROPULSION ENGINES DRIVE SHAFT COUPLING.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 2 June 1987 Resolved
PROVIDE CURRENT COAST PILOT, TIDE TABLES AND LIGHT LIST.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987

Casualty record · 2

12 July 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2724533
9 July 2016Routine · role: Involved in a Marine Casualty · activity 5938624
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record