Records from 2006 to 2026. Most recent: inspection, 30 March 2026.
Inspection history · 22
30 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8334317
29 January 2026
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8296037
30 April 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8126359
25 April 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7901634
3 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889533
4 April 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662875
4 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7663569
14 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7577233
26 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7438380
9 March 2022
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7408713
27 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7183763
7 May 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6949731
11 March 2020
Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6924565
12 February 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6907979
27 November 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6863694
9 May 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6680226
9 May 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6410446
15 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372331
16 May 2017
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6141378
10 July 2016
Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5939337
9 July 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5938624
2 May 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5867238
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 30 March 2026
Resolved
Master missing medical certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 11 May 2026
Resolution: Master completed medical card requirements and is awaiting hard copy in mail.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 March 2026
Resolved
No documentation of an active Drug and Alcohol Program on board.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: Vessel provided proof of active DAPI program to SSD inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 March 2026
Resolved
Certificate of Documentation expired and operator unable to renew due to DHS government funding lapse.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2026
Resolved 11 May 2026
Resolution: Owner purchased new certificate of documentation and is awaiting hard copy in mail.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 March 2026
Resolved
None of the FCC licenses on board.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: Vessel provided current FCC documentation to SSD inspectors.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 March 2026
Resolved
No light on magnetic compass
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 2 April 2026
Resolution: SSD inspector verified compass light is now operational.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 March 2026
Resolved
Missing monthly EPIRB testing recorded in ship's log.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 2 April 2026
Resolution: SSD inspector verified monthly EPIRB test conducted and recorded in log book.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 March 2026
Resolved
Navigation lights inoperable
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified navigation lights are now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 March 2026
Resolved
Flares expire in 2 days. Replace before getting u/w for scheduled trip in 4 days.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: Marine inspector verified vessel purchased and carries current distress flares.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 March 2026
Resolved
Hydrostatic release for inflatable life raft expired one year ago. According 46 CFR 185.70 hydrostatic releases must be marked with the expiration date of two years after the date on which the unit is installed. Hydrostatic release was marked with expiration date of 3/2025.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified hydrostatic release for inflatable life raft now current.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 March 2026
Resolved
Fire detection system not integrated.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified fire detection system integration is now operational.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 March 2026
Resolved
Fuel shutoff valve inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2026
Resolved 2 April 2026
Resolution: SSD inspector verified fuel cutoff valve is now operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 March 2026
Resolved
Support for electrical wiring in engine room missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 2 April 2026
Resolution: SSD inspector verified support for electrical wiring is now installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 April 2025
Resolved
Vessel was missing the FCC documents including the operators permit, Station License and Safety Certificate. 47 CFR Part 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2025
Resolved
Vessels ring buoy line was no longer servicable. Replace line. 46CFR180.70
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 April 2025
Resolved
Vessels hydrostatic release was not arranged correctly for the liferaft. Connect the hydrostatic release to the painter line.46CFR180.130
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 April 2025
Resolved
Vessel was missing gaurds on the mains belts. Reinstall guards. 46CFR185.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2025
Resolved
A positive shutoff valve is required to be installed at the hull penetration for submersible electrical bilge pumps. 46CFR182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Rcvd documentation that the deficiency was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2022
Resolved
Multiple twist-type connectors found facilitating a conductor splice. Facilitate splice with pressure type connector or other approved method IAW 46CFR 183.340(g).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 13 May 2022
Resolution: Installed new junction boxes to facilitate wire splices.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021
Resolved
REPLACE 2 OARS FOR LIFE FLOAT WITH 4FT LONG AND BUOYANT OARS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 April 2021
Resolved
REPLACE THE BROKEN VALVE HANDLE FOR THE FIRE HYDRANT
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021
Resolved
INSTALL BLANKS ON ENGINE ROOM DISTRUBUTION PANELS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2021
Resolved
REPLACE PLASTIC GARBAGE BINS WITH METAL
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 April 2021
Resolved
REPLACE BATTERY FOR 01 LIFE FLOAT WATERLIGHT
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2021
Resolved
LOWER GALLEY EXTINGUISHER BRACKET TO ENABLE REMOVAL IN AN EMERGENCY
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 28 April 2021
Resolution: Received pictures to duty cell phone, all SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 May 2020
Resolved
Provide DSC capability to VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2020
Resolution: Picture received via e-mail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2020
Resolved
Mount hydraulic line in steering space off of steering ram.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2020
Resolution: Hydraulic line moved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 27 February 2020
Resolved 28 May 2020
Resolution: 1-line diagram verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. 1) Replace damaged outlet cover in crew cabin. 2) Place single red wire run through passenger cabins in protective covering (conduit). 3) Provide specification sheet for power cables used on FW pump, water heater and booster pump. Cabling must be listed as UL Boat, UL Marine or meet the following standards: NFPA 70 Section 310-13, IEEE 1580, UL 1309, IEC 60092-353, NPFC MIL-C-24643A or NPFC MIL-C-24640A. Replace cable if standards are not met.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2019
Resolved 12 February 2020
Resolution: Pictures received via e-mail.