TRADITION

TRADITION is a 1979 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1980, most recently in April 2026, along with 56 deficiencies, 1 operational control and 1 casualty investigation in 2004.

Records from 1980 to 2026. Most recent: inspection, 28 April 2026.

Built
1979
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG6953
Flag
UNITED STATES
367562410, 368358470
Maury page id
psix-50208

Inspections, by type

…with no type recorded9
Years with a record 40 calendar years (1980–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.8 ft × 14.2 ft × 8.3 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE MANAGEMENT COPRORATION · MIAMI, FL, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPERDIDO KEY, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 6 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4877MMSI 368358470 · active · compulsorily equipped · granted 20 March 2024, expires 20 March 2034
WDG6953MMSI 367562410 · active · compulsorily equipped · granted 18 November 2022, expires 13 February 2033
WDA8189MMSI 366851660 · expired · compulsorily equipped · granted 10 May 2002, cancelled 14 July 2012
WRA7545MMSI not assigned · expired · compulsorily equipped · granted 2 February 1994, cancelled 13 June 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

28 April 2026 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8357175
14 November 2025 Administrative Inspection · Hull Examination · Drydock Exam · In-Service Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8267726
4 September 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8231850
22 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8117292
9 April 2024 Deficiency Check · COI Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7892583
30 January 2024 Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7858079
4 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7845186
7 March 2023 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7643373
29 March 2022 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7420785
23 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7400691
7 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7248097
24 March 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7161887
28 April 2020 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6945131
19 February 2020 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6915136
3 October 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6831438
27 March 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6651989
2 October 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6552968
23 August 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6520413
3 April 2018 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6384699
19 March 2018 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6372909
5 March 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364621
3 May 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6131808
29 November 2016 Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6051591
14 March 2016 Hull Examination · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5870937
13 July 2015 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5183000
16 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4890347
16 February 2012 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4244124
15 September 2010 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3849189
9 February 2010 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3677427
8 February 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3144033
14 December 2007 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115915
28 June 2006 Type not recorded
No type recorded · USCGC COHO (WPB 87321) · USCG Southeast District (CGD-SE) · Activity 2703318
11 April 2006 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2641415
20 January 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2569886
23 September 2005 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2566182
19 September 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2495954
18 August 2005 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2466619
17 November 2004 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 2252102
29 September 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2220309
22 June 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2106597
13 May 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2066567
23 January 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1990941
24 April 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1786830
23 April 2003 Periodic Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1779182
30 April 2002 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1610879
14 February 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1486463
15 May 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068364
9 April 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433808
6 April 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426357
6 July 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388846
9 April 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461955
18 December 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368516
15 April 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441242
18 April 1996 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459989
12 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357131
7 April 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414288
27 May 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 837033
6 May 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354319
11 May 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473526
16 December 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 950176
19 January 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222855
3 January 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044662
16 December 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1014815
11 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013715
29 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012587
29 January 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322614
23 January 1986 Credit Drydock · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297054
30 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978364
28 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975207
20 December 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966850
20 December 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279588
10 December 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965461

Deficiency record · 56

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 May 2026 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access. MI found accommodation and operating station smoke detectors to not be interconnected. 46 CFR 181.405(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: Owner installed new interconnected detectors.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 May 2026 Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. MI found bulkhead penetration at forward end of engine space to not be sealed and not meeting ASTM E-814. 46 CFR 182.35-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2026
Resolution: Owner sealed the engine rm penetrations with ASTM E814 approved sealant.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 May 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found vessel's stern light to not operate. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 28 May 2026
Resolution: Vessel owner replaced nav light.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 April 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual high level bilge alarm for crew quarters space inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 16 April 2024
Resolution: received video evidence of working alarm
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2024 Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 04 life jackets had deteriorated retro tape that need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 15 April 2024
Resolution: new tape added
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 April 2024 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Medical certificate was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 8 May 2024
Resolution: received approved medical cert
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2024 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit had several expired items, need to replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 16 April 2024
Resolution: received photo evidence of new items not expired
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 April 2024 Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 15 April 2024
Resolution: posted
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 April 2024 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 16 April 2024
Resolution: received photo evidence of posted stability letter
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 July 2015 Resolved
Complete a credit annual exam. Vessel annual exam is overdue as of 25Jun15.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2015
Resolved 14 July 2015
Resolution: Vessel completed a satisfactory exam.
Engineering › Steering Gear System › Rudder
Issued 13 July 2015 Resolved
Replaced portside rudder table support bolts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2015
Resolved 14 July 2015
Resolution: Vessel replaced portside rudder support bolts.
Engineering › Steering Gear System › Rudder
Issued 13 July 2015 Resolved
Clean / Remove rust from rudder table and make available for USCG inspection
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 20 July 2015
Resolution: Vessel removed rust and a satisfactory exam was conducted.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 July 2015 Resolved
Provide manufacture information for emergency lighting.
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 18 August 2015
Resolution: Vessel provided information.
Stability › Incline Test › General
Issued 16 February 2012 Resolved
Conduct new SST to new AAWPP
Due 31 March 2012
Resolved 25 March 2013
Resolution: Issued Stability Addendum letter IAW with new AAWPP of 185 pounds.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 February 2010 Resolved
Missing support for exhaust discharge on propulsion machinery.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Construction/Loadline › Hull › Side Shell
Issued 9 February 2010 Resolved
Various blisters in side shell gel coat of vessel were called out for repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 February 2008 Resolved
Remove hatch on collision bulkhead on the starboard outboard side, and reinspect.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 8 June 2009
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 8 February 2008 Resolved
Place cut off valves on discharge lines before the through the hull fitting for bilge pumps in forward portion of engine room.
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 8 June 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 April 2006 Resolved
Install Fireboy manual discharge cable IAW manufacturers installation instructions as required by 46CFR181.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 4 May 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 April 2006 Resolved
Provide evidence of Fireboy installation and maintenance manual as annual maintenance and inspection is conducted by owner/operator as required by 46CFR176.810
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Communications › Audible Communications › Horn/Whistle
Issued 11 April 2006 Resolved
Provide signaling device (whistle/horn) suitable for a vessel between 12-20 meters in length as required by 33CFR86.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 11 April 2006
Navigation › Piloting/Steering › Marine Charts
Issued 11 April 2006 Resolved
Provide chart of adequate scale for St. Andrew's Bay as required by 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 11 April 2006
Lifesaving › Hand Flares › Storage
Issued 11 April 2006 Resolved
Provide brightly colored water-proof container for VDS marked "Distress Signals" as required by 46CFR180.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 11 April 2006
Communications › Radio Communications › EPIRB
Issued 11 April 2006 Resolved
Repair manual plastic activation tab on EPIRB as required by 46CFR180.64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2006 Resolved
Repair/replace life-float lights and prove proper operation as required by 46CFR161.010 and 46CFR180.175.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Fire Fighting › Ventilation Systems › Operating Controls
Issued 11 April 2006 Resolved
Repair ventilation shutdowns for engine room as required by 46CFR182.465
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Communications › Radio Communications › EPIRB
Issued 18 August 2005 Resolved
Provide satisfactory evidence of serviceable battery (expiration date) for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2005
Resolved 18 August 2005
Lifesaving › Lifefloat › Serviceable
Issued 18 August 2005 Resolved
Make proper repairs/service life float. Fill small holes in buoyant material and provide spacer between stacked life floats. (46 CFR 180.70).
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 August 2005 Resolved
Replace retro-reflective tape on lifebuoy. (46 CFR 180.70)
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 August 2005 Resolved
Provide first aid kit approved in accordance with 46 CFR 160.041 (or kit with equivalent contents) as required by 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 August 2005 Resolved
Provide evidence of compliance with NFPA 10 (hydrostatic test requirements) for all portable extinguishers listed on vessel's COI. (46 CFR 176.810).
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 19 September 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 18 August 2005 Resolved
Demonstrate proper operation of all bilge high level audible and visual alarms. (46 CFR 182.530).
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 18 August 2005 Resolved
Repair high pressure fuel oil injection pump on port propulsion engine. Pump leaking from tell tale indicator and creates and especially hazardous condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2005
Resolved 26 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 August 2005 Resolved
Install suitable insulation on port propulsion engine turbo charger exhaust pipe from turbo outlet to cooling water injector. (46 CFR 177.960).
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2005 Resolved
Install suitable pipe fittings and properly support port propulsion engine salt water cooling flex hose assembly. (46 CFR 176.800).
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 18 August 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 August 2005 Resolved
Remove dead-ended electrical conductors/cables from 110/220 volt panel and terminate to a suitable electrical junction box in accordance with 46 CFR 183.05-50.
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 August 2005 Resolved
Install suitable blanks in 220 volt electrical distribution panel. (46 CFR 183.330).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 August 2005 Resolved
Make all penetrations in collision bulkhead watertight. Lower sill of all openings shall be as high and as far inboard as practical. (46 CFR 179.310).
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Stability › Watertight Integrity › Weathertight Enclosure
Issued 18 August 2005 Resolved
Repair all dogging devices on main passenger accommodation watertight escape hatch. (46 CFR 179.360).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 19 September 2005
Personnel › Training › First Aid/CPR
Issued 22 June 2004 Resolved
Provide evidence of completion of Red Cross first aid/CPR training for at least 50% of crew as recommended by USCG NVIC 1-91 Recommended Qualifications for Small Passenger Vessel Deckhands.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 29 September 2004
Resolution: Corrected.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 22 June 2004 Resolved
Provide proof of compliance with chemical testing program.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 23 June 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 22 June 2004 Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 25 June 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 June 2004 Resolved
Properly fasten toe rail, stbd side forward approximately 10 feet from stem. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 25 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 June 2004 Resolved
Provide 6 serviceable Adult Type I PFDs approved under 46 CFR 160.055.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2004
Resolved 22 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 June 2004 Resolved
Mark 08 Adult Type I PFDs with Type I retro-reflective material approved in accordance 46 CFR 164.018 as required by 46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2004
Resolved 22 June 2004
Lifesaving › Buoyant Apparatus › Float Free
Issued 22 June 2004 Resolved
Properly stow buoyant apparatus in accordance with 46 CFR 180.130 and provide a float free link approved in accordance with 46 CFR 160.073 as required by 46 CFR 180.137.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2004
Resolved 23 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 June 2004 Resolved
Provide evidence of hydrostatic test of B-II dry chemical portable fire extinguishers in accordance with NFPA as required by 46 CFR 176.810
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 25 June 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2004 Resolved
Provide watertight container for contents of first aid kit as required by 46 CFR 184.710
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 25 June 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 April 2003 Resolved
Install recharged fixed fire fighting system and test IAW 46 CFR 181.400. LEGACY COMPONENT DESC: Quantity of CO2
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2003
Resolved 24 April 2003
Resolution: Owner recharged and tested fixed fire fighting system.
Communications › Alarms/Indicators
Issued 23 April 2003 Resolved
Repair aft steering bilge high level alarm. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2003
Resolved 24 April 2003
Resolution: Owner repaired aft steering bilge high level alarm.
Lifesaving
Issued 9 April 2001 Resolved
PROVIDE A BATTERY OPERATED BULL HORN TO SATISFY THE REQUIREMENTS FOR A PUBLIC ADDRESS SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Fire Fighting
Issued 6 July 1999 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Fire Fighting
Issued 9 April 1999 Resolved
INSTALL FIXED FIREFIGHTING SYSTEM IAW 46CFR181.400.
Condition: Unknown
Due 9 April 1999
Resolved 9 April 1999
Documentation
Issued 6 May 1993 Resolved
SURRENDER CERTIFICATE OF DOCUMENTATION FOR ADDRESS CORRECTION. REF 46 CFR_x001C_ 67.27-7
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Accommodation/Occupational Safety
Issued 6 May 1993 Resolved
PROVE PROPER OPERATION OF EXISTING MSD UNIT OR RENEW WITH APPROVED TYPE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. REF 33 CFR 159.7 (c)
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Engineering
Issued 6 May 1993 Resolved
RENEW PETCOCKS ON FUEL FILTERS WITH SMALL GATE VALVES THAT WILL ACCEPT PIPE PLUGS TO PREVENT LEAKAGE TO THE SATISFACTION OF THE ATTENDING USCG _x001C_ MARINE INSPECTOR. REF 46 CFR 182.20-40(b)(7)
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993

Casualty record · 1

13 May 2004Routine · role: Involved in a Marine Casualty · activity 2066567
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LEO TOO (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.