MAURY USCG vessel records Sign in
← All vessels

CHRISTEEN

CHRISTEEN is a 1883 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1999, most recently in May 2025, along with 81 deficiencies.

Records from 1999 to 2025. Most recent: inspection, 2 May 2025.

Built
1883
Last inspected
2 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ8917
502106
Flag
UNITED STATES
367526540
Maury page id
psix-502106

Inspections, by type

…with no type recorded2
Years with a record 25 calendar years (1999–2025)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.4 ft × 15.1 ft × 3.9 ft
Registered tonnagegross 11 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderP L · GLENWOOD, NY, UNITED STATES · built 1883
Hull materialWood
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portOYSTER BAY, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN3490MMSI 367526540 · active · compulsorily equipped · granted 11 August 2022, expires 11 August 2032
WDG3485MMSI 367526540 · expired · compulsorily equipped · granted 20 April 2012, cancelled 25 June 2022
WCZ8917MMSI not assigned · expired · compulsorily equipped · granted 20 June 2000, cancelled 21 August 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

2 May 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8126920
7 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8106612
11 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7932369
10 April 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7892463
14 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7879132
1 November 2023 Inclining Experiment
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7814920
13 June 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7716266
18 May 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7690417
3 August 2022 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7523731
9 November 2021 Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7343079
26 July 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7268730
18 May 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7200819
19 October 2020 In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7085098
5 August 2020 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6920950
5 November 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6853710
17 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6813693
20 August 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6790453
26 July 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6790437
16 July 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6790439
18 June 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6762647
2 May 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6666056
23 April 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6655566
17 April 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6685543
29 January 2019 Administrative Inspection · Damage Survey · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6617199
31 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6496845
22 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6383477
21 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6310609
29 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6277785
3 August 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6229166
27 April 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6133487
18 April 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6132447
9 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5872780
27 May 2014 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4866173
29 May 2012 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4327492
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4199615
3 December 2010 Annual Inspection · Examination of Repairs · Deficiency Check · Construction Oversight · Hull Examination · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3997373
19 February 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3420467
28 March 2008 Deficiency Check · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3330028
18 September 2007 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3060322
24 August 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2756445
7 June 2006 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2674185
5 July 2005 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2414938
8 September 2004 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2189351
12 July 2004 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2126928
11 June 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1810940
17 September 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1676050
9 July 2002 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1641355
29 August 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444601
9 August 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1069194
25 May 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 230892
25 July 2000 Plan Review "T" Boat · Initial Certification
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1376623
1 October 1999 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 820802
12 July 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1404794

Deficiency record · 81

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2023 Resolved
IAW current Stability Letter this vessel is not allowed to carry more than 20 pax while underway.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2023
Resolved 14 March 2024
Resolution: Received approved MSC Stability Letter allowing a maximum pax count of 24.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 August 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2022
Resolved 13 September 2022
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 August 2022 Resolved
Provide a valid FCC Radio Safety Certificate, vessel limited to no more than 1000 feet from shore until requirement is cleared.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2022
Resolved 13 September 2022
Resolution: Received FCC Radio Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 July 2021 Resolved
PROPERLY LABEL LIFERING
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2021
Resolved 27 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2021 Resolved
PROPERLY CONFIGURE FIRE BUCKETS.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2021
Resolved 27 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 July 2021 Resolved
RENEW 1ST AID KIT
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2021
Resolved 27 July 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 July 2021 Resolved
PROPERLY CONDUCT AND LOG DRILLS.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2021
Resolved 27 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021 Resolved
Electrical equipment exposed to the weather must be watertight. Identified electrical outlet in the head space where obvious signs of weather exposure was present. replace the plug outlet and install outlet cover to protect the outlet from exposure to the elements.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2021
Resolved 27 May 2021
Resolution: Electrical components replaced and upgraded to be water tight IAW CFR
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 August 2020 Resolved
Provide 2 day flares.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2020
Resolved 5 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 August 2020 Resolved
Provide current C.O.D.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2020
Resolved 18 November 2020
Resolution: Witnessed current COD.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 August 2020 Resolved
Provide current servicing for 02 portable extinguishers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2020
Resolved 5 August 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 September 2019 Resolved
Issued requirement to conduct and log monthly inspections of the vessel's rigging. Issued requirement to schedule monthly mast inspections with an attending MI Issued requirement to not operate in winds exceeding 20 kts.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 9 August 2021
Resolution: A new mast has been installed and vessel no longer requires follow on in service inspections.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 May 2019 Resolved
Monthly drills and exercises not logged or recorded. No company policy in place to conduct or manage crew training.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 26 July 2019
Resolution: MI attended vessel and cleared item
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 May 2019 Resolved
Visual and audible alarms required required at the operating station for the machinery space. No alarm system installed for this vessel at the time of the inspection
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 18 June 2019
Resolution: MI attended vessel and witnessed correction of def.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 May 2019 Resolved
Battery wires secured to terminals using wing nutts, not permanent. Replace wing nuts with more permanent fittings
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 18 June 2019
Resolution: MI attended vessel and witnessed correction of def.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 May 2019 Resolved
Each vessel must be equipped with portable lights at the operating station and at or in the machinery space. Portable lights on board were not operable
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 18 June 2019
Resolution: MI attended vessel and witnessed correction of def.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 January 2019 Resolved
Checks in mast, checks have been labeled and details have been put into a powerpoint presentation. Check B is starting to show signs of rot. The shipwright propsed to cut the checks and insert a dutchman with west sustems g-flex. This repaird proposal is denied. Instead they are instructed to treat the rot and and monitor the checks monthly with attending USCG Marine Inspector. Decision was made to remove the deficiency and let the shipright conduct the repair to the mast. The vessel will be allowed to oprate with this repair for one year and will conduct daily inpspections of the repair with USCG oversight monthly. [name withheld] from the traveling inspector all concurs with repair, all pertaining information is in an email in the documents section of MISLE
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2019
Resolved 17 January 2020
Resolution: repairs were made and the condition was monitored throughout the operating season.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 August 2017 Resolved
Alarm not working
Condition: Improper/Lack of Maintenance
Due 10 August 2017
Resolved 21 November 2017
Resolution: Provided
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 August 2017 Resolved
expired
Condition: Improper/Lack of Maintenance
Due 10 August 2017
Resolved 31 July 2018
Resolution: O/O provided updated FCC
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2016 Resolved
Provide aspirin and eye wash.
Due 24 May 2016
Resolved 5 July 2016
Resolution: provided.
Lifesaving › Hand Flares › Not on Board
Issued 9 May 2016 Resolved
Provide 3 orange or 2 red flares.
Due 13 May 2016
Resolved 5 July 2016
Resolution: onboard.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 9 May 2016 Resolved
Service fixed fire detection system
Due 13 May 2016
Resolved 5 July 2016
Resolution: serviced.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 9 May 2016 Resolved
Service portable fire extinguishers
Due 13 May 2016
Resolved 5 July 2016
Resolution: serviced.
Engineering › Bilge Water Management System › Strainer
Issued 9 May 2016 Resolved
Install suction strainers on bilge suction in engine room.
Due 24 May 2016
Resolved 6 July 2016
Resolution: provided.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 9 May 2016 Resolved
Provide rigging inventory and maintenance plan.
Due 10 June 2016
Resolved 5 July 2016
Resolution: provided.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 9 May 2016 Resolved
Provide battery for waterlight.
Due 24 May 2016
Resolved 5 July 2016
Resolution: provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 May 2014 Resolved
Provide copy of USCG Coast Pilot [name withheld], and tides and currents for the area of operation. 46CFR184.420
Due 6 June 2014
Resolved 27 May 2014
Resolution: cleared on the spot with Eldridge book for area
Documentation › Certificates/Documents › Stability Letter
Issued 1 December 2011 Resolved
Vessel resticted to 27 total persons and 24 passegers due to Dec 1, 2011 AAWPP 185lb regulation.
Action required: 705 - Other - as specified
Resolved 5 December 2011
Resolution: Received stability intentions sheet form vessel representative.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 June 2011 Resolved
Service portable fire extinguishers.
Action required: 705 - Other - as specified
Resolved 24 June 2011
Resolution: Service completed by third party.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 6 May 2011 Resolved
Engine foundation too low for shaft tube to shaft alignment.
Action required: 705 - Other - as specified
Resolved 9 May 2011
Resolution: Engine foundation rebuilt and shaft now centered in shaft tube.
Engineering › Bilge Water Management System › Pump
Issued 6 May 2011 Resolved
Secure belt driven pump to foundation and prove operation.
Action required: 705 - Other - as specified
Resolved 9 May 2011
Resolution: Completed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 May 2011 Resolved
replace sun damaged 60' line on R/B.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2011
Resolution: Completed.
Electrical › Electric Generation Source (service) › Generator
Issued 6 May 2011 Resolved
Machine bolts securing alternator to engine mount found loose.
Action required: 705 - Other - as specified
Resolved 9 May 2011
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2011 Resolved
Secure all wiring in aft (master's) cabin & engine space w/ insulated metal retainers at least every 2'.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2011
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2011 Resolved
Provide slack for wiring to aft submersible electric bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2011
Resolution: Completed.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 May 2011 Resolved
Conduct a test of the fire detection system & machinery shut down interface.
Action required: 705 - Other - as specified
Due 24 May 2011
Resolved 9 May 2011
Resolution: Witness a satisfactory test.
Construction/Loadline › Hull › Keel
Issued 3 December 2010 Resolved
The vessel' original keel that was retained during the major rebuild during 1999/2000 and was repaired with drift pins in 2009 was found continuing to deteriorate and in need of replacement. It is the last piece of original material in the hull of this vessel. (34.5' l X 1' w X 1.7' h) N.B. old keel bolts were just beginning to loose the zinc...still smooth steel finish.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2011
Resolution: White oak (aprox 176 yo tree) keel completely replaced as original. All fasteners renewed. Keel bolts galv steel 3/4" deadwood to keel & stem to keel / 5/8" floor timbers to keel / 1/2" X 2'''''''' galv steel drifts to Ctr Bd Trunk 9 per side.
Construction/Loadline › Hull › Transverse Frame
Issued 3 December 2010 Resolved
Renewal of keel requires refit of floor timbers & lower futtocks of several transverse frames.
Action required: 705 - Other - as specified
Resolved 29 April 2011
Resolution: Completed.
Construction/Loadline › Hull › Keel
Issued 3 December 2010 Resolved
Centerboard removed & found worn.
Action required: 705 - Other - as specified
Resolved 29 April 2011
Resolution: Centerboard completely rebuilt, refastened & sheathed in FRP. Pivot bolt & winch/lifting tackle renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 3 December 2010 Resolved
Floor to frame bolts found satisfactory but shall be renewed where futtocks are renewed.
Action required: 705 - Other - as specified
Resolved 29 April 2011
Resolution: All frame bolts renewed w/ galv steel bolts. Completed.
Construction/Loadline › Hull › Bottom Plating
Issued 3 December 2010 Resolved
Bottom planking remove first 6 from keel port & stbd. Fastenings all found sat but owner plans to refasten vessel with this overhaul.
Action required: 705 - Other - as specified
Resolved 29 April 2011
Resolution: All bottom planks refastened from waterline to keel w/ galv steel screws. P & S garboard & plank 6 renewed. Plank IWO shaft tube renewed.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 3 December 2010 Resolved
Shaft tube (FRP) found worn by off ctr shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2011
Resolution: Shaft tube renewed. Fairing block fitted IWO shaft tube. Planck IWO shaft tube renewed.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 3 December 2010 Resolved
Shaft out of alignment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2011
Resolution: Alignment corrected.
Construction/Loadline › Hull › Keel
Issued 19 February 2009 Resolved
Port side of keel found loose IWO slot for centerboard trunk & allowing leakage when vessel u/w on sails w/ CB down. Repair facilitated by lag bolting both P & S section of keel IWO centerboard slot to main section of keel & CB trunk.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 10 March 2009
Resolution: Repair proposed by shipwright accepted and repairs completed satisfactorily.
Construction/Loadline › Hull › Transverse Frame
Issued 19 February 2009 Resolved
Pull sample of frame bolts as discussed w/ master & shipwright for examination.
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 24 February 2009
Resolution: Found satisfactory for five year credit.
Engineering › Bilge Water Management System › Valve
Issued 19 February 2009 Resolved
Clean, free & exercise the bilge overboard discharge valve on the stbd side fed of the batteries. Ball valve works but is very stiff. Ball is in satisfactory condition but needs to be operated periodically to insure it is free to close if needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 10 March 2009
Resolution: Completed.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 March 2008 Resolved
Repair audible alarm for fixed fire extinguishing & detection system. Note: system works but alarm does not sound, however, system also activates engine shut down w/ same circuit & that works when tested. The engine system has an audible alarm that activates awhen the fire detection system responds thus an alarm is heard when the fire detection system activates.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 1 October 2008
Resolution: Control panel W/ alarms replaced. Tested & found watching properly.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 28 March 2008 Resolved
Provide appropriate sections of 47 CFR per FCC regulations for the Marine Radiotelephone Station aboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 22 September 2008
Resolution: 47CFR copied from internet web of GPO and fitted to a notebook.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2008 Resolved
Provide up to date aspirin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 22 September 2008
Resolution: In date asirin provided.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 28 March 2008 Resolved
Provide T boat CFR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 22 September 2008
Resolution: 46 CFR subchapter T copied from internet web of GPO and fitted to a notebook.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 28 March 2008 Resolved
All MDE flexible mounts renewed during exam. Work started as owner work item prior to inspection
Due 28 March 2008
Resolved 28 March 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 5 July 2005 Resolved
Renew safety radiotelephony certificate.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2005 Resolved
Provide ammonia inhalants.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Fire Fighting › Fire Bucket › Stenciling
Issued 5 July 2005 Resolved
Stencil fire buckets and attach lanyards.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 July 2005 Resolved
Re-stencil and re-tape lifering.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Engineering › Steering Gear System › Linkage
Issued 5 July 2005 Resolved
Eliminate chaffing on centerboard retraction system.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 July 2005 Resolved
Replace lifering waterlight lanyard with one 3-6 feet in length.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 July 2005 Resolved
Seal shelf penetrations through forward and aft engineroom bulkheads starboard side.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 July 2005 Resolved
Seal deck beam penetration forward engineroom bulkhead starboard side inboard.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 5 July 2005 Resolved
Lock head overboard discharge.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 5 July 2005 Resolved
Re-label breaker for second bilge pump.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 July 2005 Resolved
Provide second lifejacket sign for under port seat.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2004 Resolved
Provide aspirin, eyewash, and ammonia inhalants for first aid kit.
Due 1 October 2004
Resolved 10 September 2004
Resolution: Per faxed ltr fm O/O, ltr scanned into documents section of vessel details.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 September 2004 Resolved
Provide 3 adult lifejackets.
Due 15 September 2004
Resolved 10 September 2004
Resolution: Per faxed ltr fm O/O, ltr scanned into documents section of vessel details.
Documentation › Certificates/Documents
Issued 17 September 2002 Resolved
Post FCC radiotelephone safety certificate. LEGACY COMPONENT DESC: FCC SSL
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 30 September 2002
Engineering › Steering Gear System › Bracket/Clamp
Issued 17 September 2002 Resolved
Repair rudder stops. (Change layout if necessary.)
Condition: Unknown
Due 30 September 2002
Resolved 30 September 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 17 September 2002 Resolved
Provide a means of recording and conducting the monthly examinations of the portable fire equipment IAW NFPA 10. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 30 September 2002
Documentation › Certificates/Documents › FCC SSL
Issued 17 September 2002 Resolved
Provide a copy of the FCC station lic.
Condition: Unknown
Due 30 September 2002
Resolved 30 September 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 September 2002 Resolved
Repair pull pin for fixed fire extinguisher. LEGACY COMPONENT DESC: Operating Controls
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 17 September 2002
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 17 September 2002 Resolved
Tighten securing bolts left loose during servicing. (Cyl mount bracket not properly secured.)
Condition: Improper Installation
Due 30 September 2002
Resolved 17 September 2002
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 September 2002 Resolved
Master shall provide copy of Aux-sail endorsement and Radio operators cert from FCC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 20 September 2002
Documentation
Issued 29 August 2001 Resolved
POST ORIGINAL CERTIFICATE OF DOCUMENTATION ON VESSEL.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 29 August 2001 Resolved
ADD RETROREFLECTIVE TAPE TO LIFE RING.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Documentation
Issued 29 August 2001 Resolved
POST EMPLOYEE ASSISTANCE POLICY.
Condition: Unknown
Due 8 October 2001
Resolved 31 October 2001
Documentation
Issued 29 August 2001 Resolved
CONDUCT AND LOG SUPERVISOR TRAINING.
Condition: Unknown
Due 8 October 2001
Resolved 17 September 2002
Fire Fighting
Issued 29 August 2001 Resolved
REPAIR/REPLACE FIRE HOSE.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Fire Fighting
Issued 29 August 2001 Resolved
PROVIDE NOZZLE FOR FIRE HOSE.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 29 August 2001 Resolved
CONDUCT AND LOG DRILLS IN ACCORDANCE WITH 46 CFR 185.520 & 185.524.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Documentation
Issued 29 August 2001 Resolved
PROVIDE COPIES OF OPERATOR'S FCC OPERATING PERMITS.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 25 July 2000 Resolved
PROVIDE APPROVED SAIL PLANS FOR THE VESSEL AND A PERMANENT STABILITY LETTER. DATA AND PLANS SHALL BE SUBMITTED TO USCG MARINE SAFETY CENTER, WASH. DC FOR APPROVAL. VESSEL SHALL NOT CARRY MORE THAN SIX PASSENGERS AFTER 25OCT00.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Stability › Incline Test
Issued 25 July 2000 Resolved
PROVIDE APPROVED SAIL PLANS FOR THE VESSEL AND A PERMANENT STABILITY LETTER. DATA AND PLANS SHALL BE SUBMITTED TO USCG MARINE SAFETY CENTER, WASH. DC FOR APPROVAL. VESSEL SHALL NOT CARRY MORE THAN SIX PASSENGERS AFTER 25OCT02.
Condition: Design Flaw
Due 30 April 2003
Resolved 11 June 2003

Ownership record