Records from 1984 to 1992. Most recent: inspection, 13 July 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
13 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957562
25 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259842
6 August 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934036
20 June 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940947
14 July 1990
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912363
16 October 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349170
11 August 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041692
18 July 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199054
25 June 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034957
26 June 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031250
1 November 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020187
24 June 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310313
24 June 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319043
8 December 1986
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308907
10 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984286
5 June 1985
Credit Drydock · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 989327
3 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283002
Accommodation/Occupational Safety
Issued 20 June 1991
Resolved
REPLACE EXHAUST VENT LOCATED IN GALLEY ABOVE STOVE.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Fire Fighting
Issued 20 June 1991
Resolved
REPAIR FIRE MONITOR LOCATED PORT SIDE AFT AND PROVE PROPER OPERATION.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Electrical
Issued 20 June 1991
Resolved
INSTALL RPM GAUGES FOR PORT AND STARBOARD GENERATORS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Navigation
Issued 25 June 1989
Resolved
PROVIDE LIGHT LIST & COAST PILOT FOR OPERATING AREA NO LATER THAN 24AUG89.
Condition: Unknown
Due 25 June 1989
Resolved 25 June 1989
Engineering
Issued 25 June 1989
Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR FUEL OIL NO LATER THAN 24AUG89.
Condition: Unknown
Due 25 June 1989
Resolved 25 June 1989
Deck/Cargo
Issued 25 June 1989
Resolved
REPAIR SPLIT SHEAVE NO LATER THAN 25MAR90.
Condition: Unknown
Due 25 June 1989
Resolved 25 June 1989
Electrical
Issued 25 June 1989
Resolved
PROVE OPERATION OF LOW LUBE OIL PRESSURE SHUTDOWN ON SDG NO LATER THAN 25JUL89. SDG=STARBOARD DIESEL GENERATOR.
Condition: Unknown
Due 25 June 1989
Resolved 25 June 1989
Navigation
Issued 25 June 1989
Resolved
REPAIR POWER FAILURE ALARM STARBOARD STEERING PUMP NO LATER THAN 24AUG89.
Condition: Unknown
Due 25 June 1989
Resolved 25 June 1989
Engineering
Issued 24 June 1987
Resolved
MAKE #1 AND #2 AIR RECEIVERS AVAILABLE FOR INTERNAL/HYDRO TESTING.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Lifesaving
Issued 24 June 1987
Resolved
REPLACE OUTDATED LIFERAFTS WITH NEWLY SERVICED RAFTS UPON ARRIVAL FROM SERVICING FACILITY BUT NOT LATER THAN 30 JUNE 1987.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Engineering
Issued 24 June 1987
Resolved
REPAIR SIGHT GLASSES FOR PORT AND STARBOARD FUEL OIL DAY TANKS.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Lifesaving
Issued 24 June 1987
Resolved
PROVIDE 12 COAST GUARD APPROVED HAND HELD FLARES.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Lifesaving
Issued 24 June 1987
Resolved
PROVIDE A SPARE CHARGE FOR SCBA.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Navigation
Issued 24 June 1987
Resolved
PROVIDE REQUIRED PUBS INCLUDING LIST OF LIGHTS AND TIDE TABLES.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Navigation
Issued 8 December 1986
Resolved
PROVIDE DEVIATION CARD FOR MAGNETIC COMPASS.
Condition: Unknown
Due 8 December 1986
Resolved 8 December 1986
Documentation
Issued 8 December 1986
Resolved
OBTAIN RADIO STATION LICENSE FOR VESSEL.
Condition: Unknown
Due 8 December 1986
Resolved 8 December 1986
Unknown
Issued 10 June 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL(RIBARDI TIDE EX SOUTHERN MAID)DN605231.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985
Construction/Loadline
Issued 10 June 1985
Resolved
ON EACH OF THE 4 DRY MUD TANK PRESSURE VESSELS, REPLACE THE MISSING MARKINGS PLATE REQUIRED BY 46 CFR 54.10-20.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985
Unknown
Issued 10 June 1985
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, BUT NOT LATER THAN 05JUL85, POST IN THEPILOT HOUSE THE STABILITY LETTER REQUIRED BY 46 CFR 93.15.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985
Unknown
Issued 10 June 1985
Resolved
PRIOR TO PLACING VESSEL IN SERVICE BUT NOT LATER THAN 05JUL85, PLACE ON BOARD THE LOADLINE CERTIFICATE.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985
Unknown
Issued 5 June 1985
Resolved
PRIOR TO PLACING VESSEL IN SERVICE BUT NOT LATER THAN 5 JULY 1985, POST IN THE PILOT HOUSE THE STABILITY LETTER REQUIRED BY 46 CFR 93.15.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
PRIOR TO PLACING VESSEL IN SERVICE BUT NOT LATER THAN 5 JULY 1985, PLACE ON BOARD THE LOAD LINE CERTIFICATE.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
ON EACH OF THE 4 DRY MUD TANK PRESSURE VESSELS, REPLACE THE MISSING MARKINGS PLATE REQUIRED BY 46 CFR 54.10-20.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985