SEA SPIRIT

SEA SPIRIT is a 1979 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1985, most recently in November 2024, along with 106 deficiencies, 3 operational controls and 1 casualty investigation in 2018.

Records from 1985 to 2024. Most recent: inspection, 19 November 2024.

Built
1979
Last inspected
19 November 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ8064
Flag
UNITED STATES
368012750
Maury page id
psix-50222

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1985–2024)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.0 ft × 6.0 ft
Registered tonnagegross 31 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPLASTIC INDUSTRIES, INC · PASCAGOULA, MS, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSANTA CRUZ, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8064MMSI 368012750 · active · compulsorily equipped · granted 10 November 2017, expires 10 November 2027
WCX2335MMSI 367150160 · expired · compulsorily equipped · granted 10 November 2006, cancelled 1 April 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

19 November 2024 Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8036700
16 October 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8016290
17 July 2023 Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7741016
2 February 2023 Administrative Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631303
28 November 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7598534
27 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7566593
25 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7215536
27 October 2020 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7085267
14 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7057996
15 July 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6751244
31 October 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6570247
22 October 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6571944
16 July 2018 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6468444
28 June 2018 Administrative Inspection · Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6459880
30 October 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6297762
2 October 2017 Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6279729
7 November 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6034480
14 October 2016 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6022663
2 November 2015 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5754556
16 October 2014 Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5005907
25 October 2010 Drydock Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3868164
29 October 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3347955
9 October 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3338099
23 October 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3081712
25 October 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2806158
4 October 2006 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2793656
1 May 2006 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2630400
6 October 2005 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2509085
14 December 2004 Plan Review "T" Boat · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2259005
10 November 2004 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2237396
23 September 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2203372
13 November 2003 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1947855
2 October 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1683251
16 January 2002 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1479121
9 January 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1430970
12 January 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1408431
14 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788477
29 January 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806437
20 January 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1029884
6 January 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788396
30 December 1998 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 810370
13 January 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388435
27 January 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1464665
22 November 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1394645
20 November 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1178683
5 February 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1182605
17 February 1995 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159805
20 January 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 869210
28 January 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1162256
29 January 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142486
20 January 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 832055
21 February 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 947438
10 February 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 958149
13 February 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1221557
4 February 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1300044
14 March 1990 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 906774
26 April 1989 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 887139
19 January 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 890920
14 April 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1196953
23 March 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984999
9 April 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1020650
16 March 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1014976
29 January 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1010791
24 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004661
13 May 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1303961
21 April 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003228
1 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 982358
12 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1285880

Deficiency record · 106

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2024 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI found vessel's life buoy is not an approved life buoy in accordance with Subchapter Q. Replace life buoy with an approved series to the satisfaction of the MI. 46 CFR 180.70 (b)(1) 46 CFR 160.050
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Operator provided proof of type-approved life float onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2024 Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. At each initial and subsequent inspection for certification, the owner or managing operator must be ready for inspection of its fire protection equipment;Inspection and testing of all smoke and fire detection systems, including sensors and alarms. MI found that vessel's installed smoke detector was inoperable. Vessel's route restricted to lakes, bays and sounds. 46 CFR 181.05-5 (Old T) 46 CFR 176.810(a)(7)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 October 2024
Resolution: Conducted satisfactory test of operating station smoke detector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 October 2024 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. MI found light on 1 life float to be inoperable. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 17 October 2024
Resolution: Conducted satisfactory test of vessel's life float light.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 October 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI found 1 life float needing patch repair to meet operational readiness standards. 46 CFR 180.175(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 17 October 2024
Resolution: Verified repairs to life float material/structure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 October 2024 Resolved
A hatch exposed to the weather must be watertight. MI found that the hatch housing the anchor and anchor chain was damaged and not water-tight. 46 CFR 179.360(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 29 October 2024
Resolution: Restored water-tight integrity to anchor chain hatch
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 October 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI found 01 portable light to be inoperable. 46 CFR 183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 18 October 2024
Resolution: Verified presence of two portable lights onboard, one light located at operating station, one light located in engine hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 October 2024 Resolved
Each flare carried to meet this section must be stowed in one of the following: A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station. 46 CFR 180.68(e)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 October 2024
Resolved 16 October 2024
Resolution: All distress flares now stored in watertight container at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. MI found 01 life jacket with insufficient markings of vessel name. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 October 2024
Resolved 16 October 2024
Resolution: Life jacket marking repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2023 Resolved
A SUBMERSIBLE ELECTRIC BILGE PUMP MAY BE USED AS A POWER BILGE PUMP PROVIDED THAT: THE PUMP IS LISTED BY AN INDEPENDENT LABORATORY AS MEETING THE REQUIREMENTS IN UL 1113. BILGE PUMP IN FORWARD COMPARTMENT IS NOT UL LISTED AND REQUIRES REPLACEMENT.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 25 August 2023
Resolution: Operator replaced pump with one that is UL listed and intalled to the satisfaction of the marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 20 July 2023 Resolved
EVERY VESSEL MUST HAVE DETAILED INSPECTION OF THE RADIO INSTALLATION BY AN FCC-LICENSEND TECHNICIAN EVERY FIVE YEARS. VESSEL'S CERTIFICATE HAS EXPIRED AND NEEDS RENEWAL. 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 16 October 2024
Resolution: MI verified updated and currect FCC Radio Inpsection Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2023 Resolved
EACH LIFE JACKET MUST BE MARKED IN CLEARLY LEGIBLE BLCOK CAPITAL LETTERS WITH THE VESSELS NAME, AND MUST BE MARKED WITH TYPE 1 RETROREFLECTIVE MATERIAL DISTRIBUTED SO AS TO BE USEFUL FOR SEARCH FROM AIR AND SURFACE CRAFT FROM ALL DIRECTIONS. SUCH MATERIAL SHOULD BE PLACED AS HIGH UP ON THE LIFEJACKET AS POSSIBLE. 27 ADULT LIFE JACKETS HAS WORN RETROREFLECTIVE TAPE AND VESSEL NAME WAS EITHER MISSING OR WORN OFF. VESSEL TO REPLACE TAPE AND RE-APPLY VESSEL NAME TO ALL LIFE JACKETS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 25 August 2023
Resolution: Operator replaced defective retro-reflective tape to the satisfaction of the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2023 Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW THE SAFE OPERATION OF THE VESSEL IN ACCORDANCE WITH THE TERMS OF ITS CERTIFICATE OF INSPECTION GIVING CONSIDERATION TO PROVISIONS FOR PROTECTION AGAINST FIRE. FORWARD PORT AND STARBOARD ENGINE ROOM BULKHEADS ARE NOT SEALED AND THE FIREBOY IS NOT RATED TO ACCOMODATE THIS ADDITIONAL SPACE. SEAL PORT AND STARBOARD FORWARD ENGINE BULKHEADS TO THE SATISFACTION OF THE MARINE INSPECTOR. 46 CFR 177.100
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2023
Resolved 25 August 2023
Resolution: Operator sealed engine room bulkheads to the satisfaction of the marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 July 2023 Resolved
A vessel to which this sub chapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel's COI expired 16JUNE2023. Vessel must complete a Certificate of Inspection renewal prior to carriage of passengers for hire. 46CFR176.100
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2023
Resolution: Conducted COI inspection. Issued COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 November 2022 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that the pump is permanently mounted. Lazarette bilge pump is not permanently mounted.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 15 December 2022
Resolution: Bilge pump is permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 September 2022 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fireboy service records must be provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 14 November 2022
Resolution: Received satisfactory FireBoy service record.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 September 2022 Resolved
An ammeter that is readily visible shall be included in the battery charger circuit. Battery charger in forward compartment does not have an ammeter. 46 CFR 183.05-20(f) OLD T.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 7 November 2022
Resolution: Received satisfactory photographs of ammeter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2022 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Life buoy has deteriorated to an unusable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 27 October 2022
Resolution: Received satisfactory photograph of life buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 September 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Engine room portable light must be made operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 27 October 2022
Resolution: Received satisfactory photographs of portable lights.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 September 2021 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine and test by operation all watertight closures in the hull, decks and bulkheads. Lazarette hatch leaking around seal and not watertight. Return watertight integrity to hatch. 46 CFR 176.25-5 (a)(2) Old T
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2021
Resolved 24 October 2021
Resolution: Operator sent video of lazz hatch watertight integrity. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 September 2021 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's stern light found inoperable. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2021
Resolved 14 October 2021
Resolution: Operator sent picture of working stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 September 2021 Resolved
A vessel must carry one floating waterlight. Vessel's ring life buoy missing attached water light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2021
Resolved 14 October 2021
Resolution: Operator sent picture of ring life buoy light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 September 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first-aid kit contained expired contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2021
Resolved 14 October 2021
Resolution: Operator sent picture of valid first aid kit contents.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 29 September 2020 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by the section, it must meet SAE J-1942 or be specifically approved by the Commandant. Piping associated with port fuel tank vent has portion of non approved flexible hose installed. Replace non approved portion in accordance with the regulations prior to utilizing port fuel tank. 46 CFR 182.720(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2020
Resolved 28 October 2020
Resolution: Verified correct piping installed on dry dock inspection via Activity #7085267
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2020 Resolved
At each inspection for certification of a vessel, the owner shall have the external inspection of fuel tank vents made available. Fuel tank vent piping is pinched between deck and fuel tank. Operator must provide proof of condition of piping w/in 07 days. 46 CFR 176.800
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 September 2020
Resolution: Owner opened area for inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. Emergency fuel shutoff valve for port tank has been disconnected and capped off due to non-operational status of the tank. Prior to bringing tank back into service, operator must notify Sector San Francisco and have MI verify condition and serviceability of tank. 46 CFR 182.455(b)(4)
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2020
Resolved 29 September 2020
Resolution: Connections made to bring tank back into service.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 September 2020 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. No alcohol swabs on board. Operations restricted within 2 hours of harbor. 46 CFR 4.06-15(a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 September 2020
Resolution: Verified proper alcohol swabs onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Four exposed wires in starboard engine room along outboard bulkhead. 46 CFR 183.200(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 29 September 2020
Resolution: Verified proper termination of exposed wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2020 Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. Strainer no longer supported by broken bracket. 46 CFR 182.420(a)(2)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 29 September 2020
Resolution: Verified proper strainer installation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 September 2020 Resolved
When stowed in tiers, life float units must be kept apart by spacers. No spacers between life floats. 46 CFR 180.137(f)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 24 September 2020
Resolution: Received photo from rep for installed spacers.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 September 2020 Resolved
The employer shall provide an Employee Assistance Program (EAP) education program that displays a community service hot-line telephone number for crew member assistance. No hot-line number on board. 46 CFR 16.401
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 24 September 2020
Resolution: Rep provided photo of posted hotline number
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 September 2020 Resolved
Each EPIRB must be tested monthly. Each survival craft must be inspected monthly to make sure it is complete and in good order. No logged maintenance of EPIRB or life float maintenance. 46 CFR 185.728(a) & 46 CFR 185.722
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 29 September 2020
Resolution: Verified maintenance/test log.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 September 2020 Resolved
Master of vessel must instruct crew as to the duties that the crew member is expected to perform in an emergency (MOB, fire drill) at least once every three months and documented for review by the Coast Guard. No training logs on board. 46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 29 September 2020
Resolution: Verified training/drill logs.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 September 2020 Resolved
As appropriate for the intended voyage, a vessel must carry U.S. Coast Pilot, light list, and tide tables. No U.S. Coast Pilot, light list, or tide tables on board. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 24 September 2020
Resolution: Rep provided copies of required documents.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 September 2020 Resolved
Each life float must be secured to the painter at one end and to the vessel on the other end. Painter not secured to life floats. 46 CFR 180.137(b)(3)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 September 2020
Resolved 15 September 2020
Resolution: Operator attached painter to painter attachment fitting on life float.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2019 Resolved
Inflatable survival craft placards with information for launching and inflating inflatable survival craft for the information of persons onboard should be posted in conspicious places by each survival craft. Liferaft bowser tied to hydrostatic release weak link, painter tied to bale of bowser.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2019
Resolved 24 July 2019
Resolution: "directions" Placard photo provided matching vessel arrangement. (painter/bowser was corrected day of inspection).
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 July 2019 Resolved
Stowage of life floats and buoyant apparatus. The float free link must meet 46CFR160.073 (subchapter Q). Float free link appears to be heaviest duty service (21 persons or more) buoyant apparatus is 10 persons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 24 July 2019
Resolution: Vsl provided evidence of correct weak link being installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2019 Resolved
A vessel must carry one ring life buoy, approved in accordance with 46CFr 160.050. Ring buoy grab line deteriorated beyond repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 24 July 2019
Resolution: Vsl replaced the ring buoy grab line.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 July 2019 Resolved
If the annual inspection reveals deficiencies in your vessels maintenance, you must make any or all repairs or improvements. Vessel deck longitudinal stringer (centerline between lazarette hatch and transom)loose and broken away from other deck frames.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 21 August 2019
Resolution: Vsl provided photo of treated wood with bracket in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 July 2019 Resolved
Watertight integrity. A hatch exposed to the weather must be water tight. Lazarette hatch shows evidence of leaking in lazarette deck framing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 30 August 2019
Resolution: Vsl owner provided photo of new hatch gasket.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 July 2019 Resolved
No tide tables onboard. Unable to determine date of charts (over 10-20 years). Retro reflective marking on PFD's faded (owner will clean and submit photos or replace with new tape).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 24 July 2019
Resolution: Vsl acquired recently updated nav chart.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 October 2018 Resolved
Aft doors on cabin space are not weathertight. A weathertight door with permanent watertight 6 inch comings must be provided for each opening located in a deck house or companion way that gives access into the hull. Ensure aft cabin doors are weathertight. 46CFR 171.124
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 8 November 2018
Resolution: Vessel representative added proper weathertight seal to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 October 2017 Resolved
Conduct satisfactory Certificate of Inspection exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2018
Resolution: Vessel completed satisfactory COI renewal.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 November 2016 Resolved
Replace all engine exhaust hose clamps in lazarette and (1) engine cooling water hose clamp in engine room.
Due 10 November 2016
Resolved 9 November 2016
Resolution: New clamps provided and installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 October 2010 Resolved
Replace damaged Type I Adult PFD.
Due 31 October 2010
Resolved 1 November 2010
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 October 2008 Resolved
Provide Rules of the Road/COLREGS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 3 November 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 October 2008 Resolved
Provide updated Light List.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 3 November 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 October 2008 Resolved
Provide updated Coast Pilot.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 November 2008
Resolved 3 November 2008
Lifesaving › Lifefloat › Painter
Issued 29 October 2008 Resolved
Permanently attach painter to lifefloat without the use of clips.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2008
Resolved 31 October 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 October 2008 Resolved
Make lifefloat float-light line 18 feet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2008
Resolved 31 October 2008
Lifesaving › Lifefloat › Float-free Link
Issued 29 October 2008 Resolved
Arrange float-free link connection to painter of life float - to avoid binding.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2008
Resolved 31 October 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 October 2008 Resolved
Provide an operating float light for life ring buoy prior to night time operations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 November 2008
Resolved 3 November 2008
Stability › Watertight Integrity › General
Issued 29 October 2008 Resolved
Provide proof of permanent attachment of hatch in collision bulkhead. (Use nuts and lockwashers instead of wing nuts.)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2008
Resolved 31 October 2008
Resolution: Gasket and permanently attached. Sent photo via e-mail.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 23 October 2007 Resolved
Renew retroreflective material on one adult PFD as identified.
Due 23 October 2007
Resolved 23 October 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 October 2007 Resolved
Renew outdated aspirin and eye wash in first aid kit.
Due 23 October 2007
Resolved 23 October 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2006 Resolved
Renew expired Aspirin and fax or email proof by receipt to our office.
Due 8 November 2006
Resolved 26 October 2006
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 25 October 2006 Resolved
Add additional deckhand's name to company's drug and alcohol program policy. Fax or email proof of this amendement to our office.
Due 8 November 2006
Resolved 26 October 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 October 2006 Resolved
Provide protective cover for batteries in lazarette to protect from falling objects IAW 46CFR 183.354(b).
Due 15 November 2006
Resolved 25 October 2006
Stability › Watertight Integrity › General
Issued 5 October 2006 Resolved
Make Engineroom/Lazeratte bulkhead watertight in way of electrical penetrations IAW 46CFR 179.320(b)
Due 15 November 2006
Resolved 25 October 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 27 October 2005 Resolved
Correct vessels call sign on Emergency Broadcast placard with vessels correct call sign.
Action required: 705 - Other - as specified
Resolved 27 October 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 October 2005 Resolved
Properly separate child type 1 PFD's from adult type 1 PFD's.
Action required: 705 - Other - as specified
Resolved 27 October 2005
Lifesaving › Lifefloat › Float Free
Issued 6 October 2005 Resolved
Make both life floats float free. Sea Painter line pinched/mounted under housing bracket.
Action required: 705 - Other - as specified
Resolved 27 October 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 November 2004 Resolved
Provide and attach float light to 10 person life float IAW 46 CFR180.175
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 10 November 2004 Resolved
Provide proff of current CPR certification for 50% of crew IAW NVIC 1-91.
Due 10 December 2004
Resolved 17 December 2004
Engineering › Lubricating Oil Service System › Hose
Issued 10 November 2004 Resolved
Provide specifications for flexible metallic engine oil lines. Lines must meet J1942 standards. IAW 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 10 November 2004 Resolved
Make engine room aft bulkhead vapor tight in way of flexible hoses, wires, and cables. IAW 46 CFR 177.405.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 10 November 2004 Resolved
Label fixed fire extinguishing system emergency pull handles IAW 46 CFR 185.612.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Engineering › Gasoline Engine (propulsion) › Pump, Cooling Water (4 cycle)
Issued 10 November 2004 Resolved
Provide plans to install main engine exhaust alarm system IAW 46 CFR 182.425
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 10 November 2004 Resolved
Provide current Local Notice to Mariners IAW 46 CFR 184.420.
Due 10 December 2004
Resolved 17 December 2004
Engineering › Bilge Water Management System › Pump
Issued 10 November 2004 Resolved
Label all four of vessel's bilge alarms IAW 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 November 2004 Resolved
Replace expired eye ointment in first aid kit IAW 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 17 December 2004
Lifesaving › Lifefloat › Painter
Issued 10 November 2004 Resolved
Attach sea painter to 10 person life float retaining strap IAW 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 10 November 2004
Resolution: Owner affixed sea painter to 10 person life float retaining strap. COS 11/10/04.
Construction/Loadline › Structures › Deck Plating
Issued 8 October 2004 Resolved
Abate furring on underside of plywood deck in both port and stbd outboard compartments amidships.
Due 10 November 2004
Resolved 10 November 2004
Engineering › Bilge Water Management System
Issued 13 November 2003 Resolved
Prove operation of the lazarett bilge alarm.
Due 13 December 2003
Resolved 26 November 2003
Resolution: Proved.
Lifesaving
Issued 13 November 2003 Resolved
Provide 2 (4' length paddles for both lifefloats w/name of vessel and secure to each lifefloat.
Due 13 December 2003
Resolved 26 November 2003
Resolution: Provided.
Lifesaving
Issued 13 November 2003 Resolved
Secure both lifefloats to the painter.
Due 13 December 2003
Resolved 26 November 2003
Resolution: Secured properly.
Fire Fighting
Issued 13 November 2003 Resolved
Renew 3 (2.5 gal) fire buckets.
Due 13 December 2003
Resolved 26 November 2003
Resolution: Renewed.
Navigation › Collision/Grounding Avoidance
Issued 13 November 2003 Resolved
Provide a Bell for fog signalling device.
Due 13 December 2003
Resolved 26 November 2003
Resolution: Provided.
Lifesaving › Hand Flares › Storage
Issued 13 November 2003 Resolved
Provide brightly colored watertight container marked Distress Signals for flares.
Due 13 December 2003
Resolved 26 November 2003
Resolution: Provided.
Lifesaving › Lifeboat Equipment
Issued 16 January 2002 Resolved
The painter line attached to the lifefloats was excessively worn. LEGACY COMPONENT DESC: Painter
Due 16 January 2002
Resolved 16 January 2002
Resolution: Owner had new painter line and replaced it.
Engineering › Bilge Water Management System
Issued 16 January 2002 Resolved
The valves for the bilge lines were not labeled at the manifold in the engineroom. LEGACY COMPONENT DESC: Manifold
Due 16 January 2002
Resolved 16 January 2002
Resolution: Labeled.
Communications › Radio Communications
Issued 16 January 2002 Resolved
The EPIRB was not located in a float-free arrangement. LEGACY COMPONENT DESC: EPIRB
Condition: Improper Installation
Due 16 January 2002
Resolved 16 January 2002
Resolution: Owner re-attached the EPIRB in a float-free arrangement.
Fire Fighting
Issued 9 January 2001 Resolved
Service fixed fire firefighting equipment in accordance with 46 CFR 176.810(b)(2) prior to the carriage of passengers.
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Navigation
Issued 28 January 1994 Resolved
PROVIDE NAVIGATIONAL CHARTS FOR ENTIRE AREA OF OPERATION
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Engineering
Issued 28 January 1994 Resolved
LABEL FUEL FILL PORTS ON MAIN DECK
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Accommodation/Occupational Safety
Issued 28 January 1994 Resolved
REPAIR LEAKING FUEL LINE TO KEROSENE STOVE
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Electrical
Issued 28 January 1994 Resolved
REPLACE UTILITY HOOKS SUPPORTING WIRING RUNS WITH APPROPRIATE CLAMPS
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Engineering
Issued 28 January 1994 Resolved
RELABEL REMOTE FUEL SHUTOFF VALVES
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Lifesaving
Issued 28 January 1994 Resolved
RENEW LABEL WITH VSL NAME ON PADDLE FOR LIFEFLOAT
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Lifesaving
Issued 28 January 1994 Resolved
REPLACE IMPROPERLY RIGGED AND DAMAGED LIFEFLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 January 1994
Resolved 1 February 1994
Deck/Cargo
Issued 10 February 1992 Resolved
INSTALL LATCHES ON ENGINE ROOM HATCHES (2).
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Fire Fighting
Issued 10 February 1992 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Electrical
Issued 10 February 1992 Resolved
REPLACE 60FT OF LINE FROM RING BUOY TO WATER LIGHT.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Lifesaving
Issued 10 February 1992 Resolved
ATTACH PADDLES TO BUOYANT APPARATUS.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Lifesaving
Issued 10 February 1992 Resolved
REPLACE ORANGE SMOKE FLARES BY MAY 1992.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Construction/Loadline
Issued 10 February 1992 Resolved
SEAL BULKHEAD PENETRATIONS AFT TO ENGINE ROOM.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Lifesaving
Issued 13 February 1991 Resolved
REPLACE RING BUOY ON STBD SIDE AND ATTACH TO LIFEFLOAT.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Construction/Loadline
Issued 14 March 1990 Resolved
PROVIDE VISUAL ACCESS TO VESSEL'S DOUBLE BOTTOM IN EACH COMPARTMENT BY CUTTING INSPECTION PORTS AT LEAST SIX INCHES IN DIAMETER. THE FITTINGS MAYBE THREADED AND SHALL HAVE AN "O" RING SEAL. ANY OTHER PROPOSAL FOR FIT- TING/INSTALLATION MUST BE MADE TO THE [name withheld] DRYDOCK.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Fire Fighting
Issued 26 April 1989 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989 Resolved
RENEW LINES ON LIFE BUOY FOR LIFE FLOAT.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Construction/Loadline
Issued 23 March 1988 Resolved
PROVIDE ACCESS FOR FWD PEAK THROUGH FWD QUARTERS TO ALLOW FOR INSPECTION OFFWD PEAK AREA.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Accommodation/Occupational Safety
Issued 23 March 1988 Resolved
PROVIDE HARD PIPING FOR KEEL COOLERS TO ABOVE WATERLINE.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Unknown
Issued 23 March 1988 Resolved
TIGHTEN BELTS ON MECHANICAL DRIVEN BILGE PUMP.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Unknown
Issued 23 March 1988 Resolved
PROVIDE GUARD OVER MECHANICAL BILGE PUMP BELTS.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Lifesaving
Issued 16 March 1987 Resolved
REPLACE WEAK LINK TO LIFE FLOAT.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Fire Fighting
Issued 21 April 1986 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Engineering
Issued 21 April 1986 Resolved
INSTALL PROTECTIVE COVERS AROUND EMERGENCY FUEL SHUT OFF VALVES SO AS TO MAKE REMOTE FROM ENGINEROOM COMPARTMENT.
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986

Casualty record · 1

22 October 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6571944
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.