MAURY USCG vessel records Sign in
← All vessels

THUNDER CAT

THUNDER CAT is a 2000 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2000, most recently in May 2026, along with 46 deficiencies and 1 casualty investigation in 2015.

Records from 2000 to 2026. Most recent: inspection, 18 May 2026.

Built
2000
Last inspected
18 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG7935
Flag
UNITED STATES
367572340
Maury page id
psix-5023

Inspections, by type

…with no type recorded2
Years with a record 24 calendar years (2000–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)51.3 ft × 15.8 ft × 5.3 ft
Registered tonnagegross 28 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT C CARLSON · CAPE MAY, NJ, UNITED STATES · built 2000
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCAPE MAY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG7935MMSI 367572340 · active · compulsorily equipped · granted 18 May 2023, expires 26 April 2033
WDF7858MMSI 367488880 · expired · compulsorily equipped · granted 5 May 2011, cancelled 17 July 2021
WDF4708MMSI 367454960 · expired · compulsorily equipped · granted 2 June 2010, cancelled 8 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCZ8232MMSI not assigned · expired · voluntarily equipped · granted 18 May 2000, cancelled 24 July 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

18 May 2026 Internal Structural Exam · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8344185
14 August 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8204899
3 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8103119
24 June 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7941043
7 June 2023 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7709249
13 February 2023 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7637094
11 October 2022 Damage Survey · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7575313
8 June 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7465309
19 May 2021 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7170901
6 May 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7190554
20 April 2021 Deficiency Check · Construction Oversight · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7179649
15 October 2020 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7077567
28 July 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7015045
3 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6802542
20 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6689002
2 October 2018 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6553409
22 May 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6415319
31 May 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6161004
27 April 2017 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6129615
8 November 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6037812
18 May 2016 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5880652
5 August 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5760421
2 October 2014 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4997792
12 May 2014 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4879070
14 May 2012 DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4311602
21 September 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3851624
7 November 2008 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3360571
12 October 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3078271
5 June 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2951005
3 February 2006 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2577546
27 June 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2405363
15 April 2004 Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2228374
13 June 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1816017
11 June 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1628604
1 May 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1611789
15 May 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063971
31 July 2000 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063970
27 July 2000 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1054439
24 July 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 821268

Deficiency record · 46

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2026 Resolved
A VESSEL OF AT LEAST 26 FEET IN LENGTH MUST BE PROVIDED WITH INDIVIDUAL BILGE LINES AND BILGE SUCTIONS FOR EACH WATERTIGHT COMPARTMENT. MI OBSERVED THE FORWARD STARBOARD BILGE PIPING LEAKING AT THE OVERBOARD FITTING DURING A BILGE PUMP TEST. O/O SHALL FIX FITTING TO SATISFACTION OF MI. 46CFR182.510 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2026
Resolved 27 May 2026
Resolution: Vsl Owner replaced fitting on pipe, bilge pump was tested all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 18 May 2026 Resolved
A VESSEL WITH INSTALLED TOILET FACILITES MUST HAVE A MARINE SANTITATION DEVICE THAT COMPLIES WITH 33CFR159. MI OBSERVED THERE WAS NO METHOD TO CONTROL UNAUTHORIZED OVERBOARD DISCHARGE. O/O SHALL SECURE VALVE TO SATISFACTION OF MI. 46CFR184.704 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2026
Resolved 27 May 2026
Resolution: Vsl owner placed lock on MSD overboard valve to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 August 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years… If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel did not have FCC Radio Telephony Certificate. Vessel is restricted to 1000ft from shore until FCC Radio Telephony Certificate is provided. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 29 August 2025
Resolution: Verified vessel had valid certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 August 2025 Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license. Operator did not have FCC Operator Certificate. Vessel is restricted to 1000ft from shore until operator provides certificate. 47 CFR 80.155
Action required: 705 - Other - as specified
Resolved 15 June 2026
Resolution: Verified FCC Operator Certifcate and added picture to MISLE 8344185.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 August 2025 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels EPIRB Hydrostatic Release is expired. Vessel is restricted to 3 nautical miles from shore until valid Hydrostatic Release is installed. 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 29 August 2025
Resolution: Verified new hydrostatic release
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jacket. Life Jacket storage location did not differentiate between child and adult. Provide appropriate placarding for life jacket storage locations. 46 CFR 184.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 29 August 2025
Resolution: Verified placarding on storage areas
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 August 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10). First Aid kit had multiple expired items. Provide required items for a full First Aid outfit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 29 August 2025
Resolution: Verified new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 August 2025 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Lift Raft Hydrostatic Release was improperly installed. 46 CFR 180.130
Action required: 10 - Deficiency Rectified
Resolved 14 August 2025
Resolution: Owner corrected hydrostatic assembly prior to inspectors departing.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 June 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 28 June 2024
Resolution: Showed the primary captains valid mmc and medical card.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 June 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel was missing emergency instructions. Vessel must create and post the crew emergency instructions in 14 days to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 28 June 2024
Resolution: Vessel has the emergency instrustions posted.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 24 June 2024 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel was missing the emergency broadcast placard. Vessel must create and post the emergency broad cast placard at the radio station in 14 days to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 28 June 2024
Resolution: Vessel has the radio emergency broadcast placard posted.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 24 June 2024 Resolved
Section 151.59 (Placards) applies to- (3) A manned ship of 40 feet or more in length that is operated under the authority of a country other than the United States while in the navigable waters or the Exclusive Economic Zone of the United States. Vessel was missing garbage placard. Vessel must obtain and post the garbage placard in 14 days to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 28 June 2024
Resolution: Vessel posted the garbage placard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 June 2023 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release unit was expired on EPIRB. Replace disposable hydrostatic release unit to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2023
Resolved 7 June 2023
Resolution: O/O replaced hydrostatic realease, sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 June 2023 Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the commission or its designees. MMSI number needs to be updated on VHF radio. 47 CFR 80.103 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: O/O input correct MMSI number into VHF.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 June 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Emergency fuel shutoff valves for fuel tanks were not labeled. Label fuel shutoffs to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: O/O labeled fuel shut offs
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 June 2023 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure device to prevent discharge of sewage. Secure device to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: O/O installed valve with locking mechanism.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2021 Resolved
Port side fuel tank reach rod was disconnected.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2021
Resolution: Received photo of reach rod reattached.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2020 Resolved
Acquire 01 fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 15 October 2020
Resolution: Received photo of required fire buckets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2020 Resolved
Replace hose on port fuel tank fill with one rated for fuel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 15 October 2020
Resolution: Fuel fill hose was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2020 Resolved
Install double hose clamps on both shaft seal dripless bearings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 15 October 2020
Resolution: O/O installed dbl hose clamps on water line.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2019 Resolved
Vessel owners informed MIs that they replaced one propeller after hitting a piece of timber while underway. Prove proper installation and operation of propulsion machinery with an underway trial to the satisfaction of the attending MI. - 46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 5 September 2019
Resolution: Attended vessel and observed satisfactory operation of propulsion machinery. Issued additional deficiency to provide propeller report and installation of shaft key.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 September 2019 Resolved
Vessel owners did not notify the cognizant OCMI prior to hauling the vessel out of the water for repairs. - 46 CFR 176.665(a)
Action required: 10 - Deficiency Rectified
Resolved 3 September 2019
Resolution: Spoke to vessel owner [name withheld] Provided him with the 24/7 Command Center phone number for notifications.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 20 May 2019 Resolved
Cap fuel cross connect. Replace with SAE-J1942 hose at next drydock. 46 CFR 182.7210(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 October 2019
Resolution: Observed SAE J1942 hose installed for fuel crossover.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 May 2018 Resolved
Replace EPIRB battery. VSL limited to operations within 3 miles from shore until battery is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2018
Resolved 7 June 2018
Resolution: Vessel owner replaced EPIRB with new unit. Unit Identification number 2DCC90207EFFBFF
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 June 2017 Resolved
Provide FCC safety radio certificate with proper call sign.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 2 June 2017
Resolution: Received picture of the updated certificate with proper call sign.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 1 June 2017 Resolved
Provide documentation for testing of fire detection system.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Talked to the fire servicing technician on the phone and he verified the report had a typo. The detection system was properly tested.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 June 2017 Resolved
Provide up to date charts for the operating area.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Received picture of new charts O/O purchased.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2017 Resolved
Install proper navigation stern light.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 1 June 2017
Resolution: Received picture of installed functioning stern light.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 June 2017 Resolved
Stencil lifering with vessel's name.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 2 June 2017
Resolution: Received picture with stenciled lifering.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 27 April 2017 Resolved
Make engines available for inspection by attending USCG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 May 2017
Construction/Loadline › Hull › Weld
Issued 27 April 2017 Resolved
Grind and reweld 02 identified cracked welds in speace forward of Engine Room as marked and discussed. (Fire Room)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 19 May 2016 Resolved
AB01: Owner/operator must prove proper operation of DSC radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 25 May 2016
Resolution: Vessel registered, received its MMSI number, and imputed it into its radio.
Engineering › Bilge Water Management System › Valve
Issued 12 May 2014 Resolved
A positive shut-off valve is to be installed in 06 electric bilge pumps discharge lines at the hull penetration.
Due 22 May 2014
Resolved 22 May 2014
Engineering › Fuel Oil Service System › Hose
Issued 12 May 2014 Resolved
Fuel fill pipes require bonding on port/stbd tanks.
Due 22 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 September 2010 Resolved
Popped filet weld.
Action required: 705 - Other - as specified
Resolved 29 September 2010
Resolution: Filet weld grinded out, and re-welded. SAT.
Stability › Watertight Integrity › General
Issued 5 June 2007 Resolved
Make wire penetrations watertight thru bulkhead 2 and 3
Condition: Improper Installation
Due 19 June 2007
Resolved 25 July 2007
Resolution: Sealed bulkheads around wire penetrations.
Communications › Radio Communications › EPIRB
Issued 5 June 2007 Resolved
Provide valid NOAA EPIRB registration. Vessel restricted to 3 NM until provided.
Action required: 705 - Other - as specified
Resolved 7 June 2007
Resolution: Received fax copy of current NOAA registration.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2006 Resolved
First Aid Kit has expired eyewash and aspirin. Required owner to replace expired items.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 22 May 2006
Resolution: Received faxed copy of receipt for eyewash and aspirin proving that owner has replaced expired items.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 May 2006 Resolved
Did not get vessel underway due to high winds and bad weather. Must conduct satisfactory underway check ride.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 3 August 2006
Resolution: Conducted SAT U/W check ride.
Communications › Radio Communications › EPIRB
Issued 9 June 2005 Resolved
EPIRB NOT OPERABLE, VESSEL RESTRICTED TO WITHIN THREE MILES.
Action required: 705 - Other - as specified
Resolved 5 July 2005
Resolution: recieved fax report from MTS Inc. attesting to repairs.
Documentation › Certificates/Documents
Issued 11 June 2002 Resolved
Provide current Coast Pilot. LEGACY COMPONENT DESC: Coast Pilot
Condition: Improper/Lack of Maintenance
Due 11 July 2002
Resolved 12 June 2002
Resolution: One (1) Coast Pilot purchased and placed on board.
Documentation › Manuals/Policy Documentation
Issued 11 June 2002 Resolved
Show current enrollment in approved Drug Testing program. LEGACY COMPONENT DESC: Drug and Alcohol program
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002
Resolution: Provided proof of enrollment in an approved Drug Testing program.
Lifesaving › Buoyant Apparatus
Issued 11 June 2002 Resolved
Provide approved paddles for each life float. LEGACY COMPONENT DESC: Life Float Paddles
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2002
Resolution: Four (4) paddles purchased for life floats.
Documentation
Issued 24 July 2000 Resolved
PROVIDE VALID FCC SAFETY INSPECTION CERTIFICATE.
Condition: Unknown
Due 24 August 2000
Resolved 2 November 2000
Lifesaving
Issued 24 July 2000 Resolved
PROVIDE PROOF OF REGISTRATION FOR 406MHZ EPIRB.
Condition: Unknown
Due 24 August 2000
Resolved 22 August 2000
Navigation
Issued 24 July 2000 Resolved
VESSEL RESTRICTED TO 1000 FEET FROM SHORE UNTIL EPIRB IS REGISTERED IN NAMEOF VESSEL.
Condition: Unknown
Due 24 August 2000
Resolved 2 November 2000

Casualty record · 1

5 August 2015Routine · role: Involved in a Marine Casualty · activity 5760421
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record