← All vessels
MISS MAYA
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named MISS MAYA
MISS MAYA is a 1979 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1981, most recently in May 2026, along with 68 deficiencies and 5 operational controls.
Records from 1981 to 2026. Most recent: inspection, 15 May 2026.
- Built
- 1979
- Last inspected
- 15 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 68 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
605483
WDQ8459
50235
Flag
UNITED STATES
367707820
Maury page id
psix-50235
Inspections, by type
…with no type recorded10
Years with a record
44 calendar years (1981–2026)
The 75 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)117.1 ft × 24.9 ft × 7.4 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ8459MMSI 367707820 · active · compulsorily equipped · granted 17 March 2026, expires 17 March 2036
WDI5364MMSI 367707820 · expired · compulsorily equipped · granted 23 December 2015, cancelled 7 March 2026
WDG4132MMSI 367533310 · expired · compulsorily equipped · granted 1 June 2012, cancelled 6 August 2022 · licensed under a name not among this hull’s recorded names (not shown)
WBC9152MMSI not assigned · cancelled · compulsorily equipped · granted 3 October 1996, cancelled 17 February 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 75
15 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8320965
10 July 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8130487
14 February 2025
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8081118
31 January 2025
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8072881
6 January 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8059108
11 June 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7910276
6 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7617529
27 December 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7614236
14 December 2022
Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609333
28 April 2022
Excursion Permit · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7435762
5 November 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7345589
21 July 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7241926
1 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104500
29 September 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7068171
11 December 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6871925
6 November 2019
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6850997
26 September 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6821923
20 September 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6816986
9 September 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6807949
3 July 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6728871
28 November 2018
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6588183
1 November 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6557656
12 October 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6261833
26 September 2016
Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6009526
26 October 2015
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5751040
14 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4814831
20 June 2012
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4350356
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4199968
30 March 2009
Hull Examination · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3442800
10 April 2008
Administrative Inspection · Ballast Water Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3181141
9 March 2007
Re-Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2885125
26 October 2006
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808493
14 July 2006
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2712356
21 April 2005
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2337515
15 July 2004
Internal Structural Exam · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2134366
29 May 2003
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1804619
17 March 2003
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1758206
2 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1683154
14 November 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414036
19 October 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365994
11 November 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369414
3 May 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792608
20 November 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426147
22 October 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1413255
20 November 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396620
28 November 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445030
9 February 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1152157
5 December 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1374192
16 November 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389920
16 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425384
20 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161481
11 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 537410
6 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142374
15 December 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401650
6 July 1992
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266525
16 December 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260405
16 December 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265899
7 January 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221869
17 January 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214278
21 September 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1014820
27 January 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898292
20 April 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040053
24 February 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1027737
22 January 1988
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1016032
2 March 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010645
20 August 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988493
27 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306411
26 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981150
31 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972960
28 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274264
2 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278353
5 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273602
3 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969025
2 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969196
4 June 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272903
Deficiency record · 68
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2026
Resolved
Vessels described by 46 CFR 175.110(c) must have an
interconnected fire detection system in compliance with
§ 181.450 installed in all enclosed areas where
passengers and crew have routine access, including
accommodation spaces and machinery spaces. MI observed
01 missing smoke detector in the engine room and 01
missing detector in port crew berthing room. The vessel
is restricted to a limited coastwise route, not
exceeding 20 nautical miles from a harbor of safe
refuge. This restriction remains in effect until the
fire detection system is replaced and tested to the
satisfaction of the attending Marine Inspector.
46 CFR 181.405(c)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2026
Resolved
If 1.5 inch diameter fire hose is used after January 1,
1980, each length of hose must: Be lined commercial fire
hose that conforms to Underwriters' Laboratories, Inc.,
Standard 19. MI observed both fire hoses were not in
conformance with UL19 requirements.
46 CFR 181.15-10(d)(1)
(OLD T)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 May 2026
Resolved
A mechanical, manually operated device to assist in
launching a survival craft must be provided if: (1) The
survival craft weights more than 90.7 kilograms (200
pounds); and (2) The survival craft requires lifting
more than 300 vertical millimeters (one vertical foot)
to be launched. MI observed one inflatable liferaft and
one IBA located on the exterior of the second deck that
weighed more than 200 pounds and required lifting in
excess of one vertical foot for launching. Vessel shall
submit plans and provide an arrangement satisfactory to
the Coast Guard for mechanically assisted launching of
the survival craft.
46 CFR 180.130(c)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2026
Resolved
Each vessel must have adequate emergency lighting fitted
along the line of escape to the main deck from all
passenger and crew accommodation spaces located below
the main deck. MI observed 02 emergency lights in the
engine room and 01 emergency light in the saloon did not
automatically actuate during testing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 July 2025
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all crew accommodation spaces located below the main deck. No emergency lighting was observed in engine room. There was a red frame light globe between the main distribution panel and engine room emergency egress but did not energize during loss of power. Remaining below deck, passenger cabin and wheel house emergency lighting illuminated during loss of power test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 July 2025
Resolved
A work space must be of adequate construction with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew in a manner practicable for the service, route, speed, and modes of operation of the vessel. Lowest step on port exterior ladder from cargo deck to wheel house cracked away from outboard side frame
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 July 2025
Resolved
A hatch cover must be attached to the hatch frame by hinges, captive chains, or other devices to prevent its loss. Lazarette hatch chain not secured to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2025
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Lazarette bilge piping across port engine room bulkhead pulled away from two supports.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2024
Resolved
On a vessel of at least 26 ft in length, a visual and audible alarm must be provided at the operating station. MI observed no audible bilge alarm indication at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 February 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced loss of propulsion due to faulty spring on the port gear box. Provide proof of proper operation to the attending USCG marine inspector.
46 CFR 182.200
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2023
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Fire extinguisher in the engine room does not have proper bracket. Install appropriate bracket to the satisfaction to the attending USCG marine inspector.
46 CFR 181.500
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 December 2022
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 April 2022
Resolved
(a) Each vessel certificated to operate on an oceans route in cold water must either:
(1) Be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board.
- MI discovered vessel equipped with two 25 man IBAs instead of one 50 man and one 25 man.
- Vessels passenger count is reduced to 50 POB until deficiency is rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2021
Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] observed that 1) Compressed air system compressors do not power down when proper operating pressure is achieved. 2) Gauges on air receivers do not provide sufficient pressure range to verify 200psi relief valves. and 3) Air receiver pressure is only being regulated by unverified 200psi relief valves popping.
Prove proper operation of the compressed air system prior to operations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 September 2020
Resolved
Each vessel that operates on the high seas or beyond 3 mile from the coastline of the great lakes must have on board a FCC type accepted category 1 406 MHz EPIRB. EPIRB battery had expired June 2019. Provide an operational EPIRB. Vessel is restricted in its rout to no more than 3 miles from the coastline.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 September 2020
Resolved
Fire hose shall be 1 1/2 inches in diameter and 50 ft in length. Vessel port side fire hose had multiple pin hose right after nozzle. Replace port side fire hose.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2020
Resolved
All vessels must have nav light that are in compliance with the applicable sections of the international and inland nav rules. Vessels not under command lights were inop. Provide operable not under command lights (red over red).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2019
Resolved
Lazarette bilge suction is inoperable. Prove proper operation of bilge system to the satisfaction of an attending marine inspector prior to movement.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 November 2019
Resolved
Need to conduct satisfactory man overboard drill prior to movement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019
Resolved
Air receivers located in engine room were not made available for inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 November 2019
Resolved
EPIRB is not tested monthly and is not logged properly.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 November 2019
Resolved
There is no fire fighitng dril/training log on board. There is no evidence that fighting fire drills have been sufficiently conducted.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 November 2019
Resolved
There is no training/drill log for abandon ship or man overboard drills on board. There is no evidence that drills have been conducting sufficiently.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 November 2019
Resolved
Fluorescent light located in the engine room is missing a cover leaving the bulbs exposed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019
Resolved
There is no non conductive matting in front of a high voltage distribution panel in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019
Resolved
Electrical panel in the engine room has an opening in the panel for a breaker and is not properly blanked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019
Resolved
Steering pump/components are have a hydraulic fluid leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2019
Resolved
A vessel must be operated IAW applicable laws and regulations and in such a manner as to afford adequate precautions against hazards that might endanger the vessel and persons being transported.
Vessel and crew are unprepared and failed annual COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2019
Resolved
Aft ballast tank is being used as a fuel tank. Remove diesel fuel from tank getting underway (i.e. before vessel movement).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2019
Resolved
Fire extinguishers were found to be beyond their annual maintenance date.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 November 2018
Resolved
Grind/reweld cracked welds and weld missed welds in steering gear compartement as marked by MI. 20 IWO deck insert from 2012, 01 crack on stern/stbd side at stiffener, 01 crack on port side stiffener just aft of fuel tank. Grind/reweld cracks on deck support at top of tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2018
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure,and personnel injury. Starboard generator displayed excessive oil leakage as well as oil soaked rags on deck/in bilge below the starboard generator; additionally oil staining was noticeable around the exhaust outboard vent (i.e. along the STBD hull).
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 November 2018
Resolved
The emergency lighting required by paragraph (a) of 46CFR183.432 must automatically actuate upon failure of the main lighting system. The emergency lighting failed to function as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 November 2018
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Reach-rod was disconnected and inoperable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2018
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire explosion, machinery failure and personnel injury. Hydraulic leak found on hydraulic fluid line extending from the steering pump; area of leak located behind bulkhead near mid-ship.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2018
Resolved
Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries. Back-up batteries installed on top of the pilot house within a battery box is missing the top (lid) and exposed to the elements particularly rain - lid needs to be replaced/installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2018
Resolved
Water for cooling the exhaust pipe must pass through the entire length of the exhaust pipe. Supply hose for cooling water on the Port side main diesel engine is kinked creating a reduction in water flow within the exhaust pipe.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 November 2018
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The sea painter shackle was attached to the apparatus cradle rather than to the weak-link. The configuration would have negated the purpose of the weak and eliminated the ability of the survival craft to float free from the vessel.
Lifesaving › Inflatable Buoyant Apparatus › Capacity
Issued 27 October 2017
Resolved
Vessel limited to 25 passengers until second inflatable life raft is onboard to the satisfaction of attending coast guard marine inspector.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 12 October 2017
Resolved
Provide satisfactory means to recover man overboard from water to deck of vessel.
Engineering › Bilge Water Management System › Piping
Issued 12 October 2017
Resolved
Make repairs to bilge and fire pump systems overboard discharge line.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 October 2017
Resolved
Provide smoke detectors for all overnight accomodation spaces.
Construction/Loadline › Hull › Weld
Issued 12 October 2017
Resolved
Back gauge and re-weld all cracked welds in lazarette.
Lifesaving › Lifefloat › Lifeline
Issued 12 October 2017
Resolved
Replace grab lines on all life floats.
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 October 2017
Resolved
Provide placarding for all lifejacket storage locations.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 October 2017
Resolved
Provide covers for all open panels on each breaker panel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 October 2017
Resolved
Provide latching mechanism for oven to ensure closure while underway.
Documentation › Certificates/Documents › Stability Letter
Issued 12 October 2017
Resolved
Post each page of stability letter at pilot station.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 October 2017
Resolved
Post certificate of inspection in conspicuous location.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 26 September 2016
Resolved
Severe pitting was discovered on the port and starboard stern tubes during inspection. Prove to the attending Marine Inspector that both stern tubes have no more than %25 wastage. If replacement is necessary provide repair plan for approval prior to commencing work.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 26 September 2016
Resolved
Renew 03 aluminum flanges for seachest tops (found severely wasted)
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 June 2012
Resolved
Emergency shut off vavle was leaking
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 June 2012
Resolved
A low flow sensor for the wet exhaust on the port and starboard engine needs to be installed with a audible or visual indicator located at the operating station.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 14 July 2006
Resolved
Repair back-up electrical power for E/R and machinery space.
Construction/Loadline › Penetrations › Weld
Issued 14 July 2006
Resolved
Repair fractures at exhaust penetrations at hull for MDE's and Gen.
Lifesaving › Lifefloat › Painter
Issued 15 July 2004
Resolved
Remove painter between two lifefloats.
Construction/Loadline › Hull › Weld
Issued 15 July 2004
Resolved
Repair three cracked welds in aft port corner of lazarette.
Engineering › Compressed Air System (start air)
Issued 17 March 2003
Resolved
Prior to operating/use of pressure vessel (port side engineroom), provide manufacture U1A sheet and plans "certified by registered professional engineer" to the attending Marine Inspector. 46 CRR 54.01-5 LEGACY COMPONENT DESC: Receiver/Bottle
Lifesaving › Buoyant Apparatus
Issued 17 March 2003
Resolved
RENEW WEAK-LINK AND PAINTER
Communications › Internal Communications System
Issued 17 March 2003
Resolved
INSTALL PUBLIC ADDRESS SYSTEM AS REQUIRED BY 46 CFR 184.610.
Communications › Radio Communications › EPIRB
Issued 17 March 2003
Resolved
INSTALL VALID HYDROSTATIC RELEASE
Lifesaving
Issued 19 October 2000
Resolved
VESSEL IS RESTRICTED TO NOT MORE THAN 75 TOTAL PERSONS ON BOARD UNTIL ADDL PRIMARY LIFE SAVING EQUIPMENT IS PROVIDED OR THE NUMBER OF PERSONS ALLOWED OM BOARD IS REDUCED FROM 76 TO 75.
Electrical
Issued 5 December 1994
Resolved
REPLACE MISSING COVER ON OVERHEAD LIGHT FIXTURE LOCATED ON STARBOARD SIDE AFT PASSENGER COMPARTMENT.
Electrical
Issued 5 December 1994
Resolved
REMOVE DEADEND WIRING UNDER STEERING STATIONS FORE AND AFT IN WHEELHOUSE.
Construction/Loadline
Issued 5 December 1994
Resolved
REPAIR OR REPLACE WATERTIGHT THROUGH DECK FITTING FOR FOREPEAK BILGE VALVE REACH ROD.
Construction/Loadline
Issued 5 December 1994
Resolved
REPLACE MISSING WATERTIGHT CLOSURE FOR FUEL COMPARTMENT GOOSE NECK VENT LOCATED ON STARBOARD SIDE OF DECK HOUSE.
Construction/Loadline
Issued 5 December 1994
Resolved
REPAIR OR REPLACE WATERTIGHT THROUGH DECK FITTING FOR FUEL CUT-OFF REACH ROD PORT AND STARBOARD SIDES.
Unknown
Issued 5 December 1994
Resolved
REMOVE ELECTRICAL FIXTURES, WIRING, AND MARKINGS RELATED TO DISCONTINUED FUEL TRANSFER PUMP SYSTEM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.