11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 03 adult sized life jackets found un-servicable during the inspection. Vessel restricted to 152 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 March 2025
Resolution: Vessel procured new life jackets and placed into service. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2025
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Found three power cables under the console with blade fuses. Remove and install appropriate fuses.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 13 March 2025
Resolution: All SAT.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 February 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. No valid EPIRB registration onboard the vessel. Vessel is restricted Lakes, Bays and sound route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 March 2025
Resolution: Vessel received new documents. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 February 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. Pain relief medicine in the first aid kit are expired.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 13 March 2025
Resolution: First aid kit is up to date. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 February 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(2) U.S. Coast Pilot or similar publication; Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. U.S. Coast
Pilot is missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 13 March 2025
Resolution: Vessel has required pubs. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025
Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Vessel crew cleaned and painted hull before exam. MI's discussed with operator exam expectations and to not paint hull before exam.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 February 2025
Resolution: MI's counseled operator on expected vessel hull condition.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 March 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Uppermost life float is showing cracking in the coating exposing the foam. Make proper repairs or renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 11 April 2024
Resolution: Life float was renewed and properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter). Prove annual maintenance records for all portable fire extinguishers.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 March 2024
Resolution: Annual maintenance conducted by third party fire servicing company.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 March 2024
Resolved
At each subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Operation of the fire main system and checking of the pressure at the most remote and highest outlets. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 March 2024
Resolution: Proved proper operation of the fire pump and two hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 February 2023
Resolved
Six hand red flare and orange smoke distress signals approved in accordance with § 160.021 in subchapter Q of this chapter. All distress flares are expired. Replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2023
Resolution: Owner provided new distress flares. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 February 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. Kit on board had expired contents. Provide new contents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2023
Resolved 25 April 2023
Resolution: Owner notified MI, new ORIEN kit is 30 days back order. MI adjusted action from 701 code to 50 code. Owner supplied brand new first aid kit and is now onboard the vessel for use.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 13 February 2023
Resolved
The float-free link is designed to be broken by the buoyant force of the life float or buoyant apparatus so that the float or apparatus breaks free of a vessel that sinks in water deeper than the length of the painter. Both weak links were installed incorrectly. Re-install links to the satisfaction of the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2023
Resolution: Owner installed line and links correctly. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 February 2023
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Multiple batteries were expired or the wrong type. Replace with valid correct batteries.
Action required: 705 - Other - as specified
Due 20 February 2023
Resolved 21 February 2023
Resolution: Owner installed new batteries in water light. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 February 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life raft body had multiple cracks showing the foam interior. Properly repair IAW manufactures specs and provide for re-inspection by MI.
Action required: 705 - Other - as specified
Due 20 February 2023
Resolved 21 February 2023
Resolution: Owner repaired cracks in life raft IAW manufactures specs. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 February 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life raft paddle was deteriorated beyond service use. Replace with in-kind equipment.
Action required: 705 - Other - as specified
Due 20 February 2023
Resolved 21 February 2023
Resolution: Owner procured new in-kind paddle and labeled correctly. All SAT.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 13 February 2023
Resolved
A station bill must be posted by the master on a vessel of more than 19.8 meters (65 feet) in length having a Certificate of Inspection requiring more than four crew members at any one time, including the master. (b) The station bill must set forth the special duties and duty station of each crew member for various emergencies. The duties must, as far as possible, be comparable with the regular work of the individual. Provide a station bill for attending MI.
Action required: 705 - Other - as specified
Due 20 February 2023
Resolved 21 February 2023
Resolution: Owner created and posted station bill in multiple locations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2023
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Post EAP where it can be utilized by crewmembers.
Action required: 705 - Other - as specified
Due 20 February 2023
Resolved 21 February 2023
Resolution: Owner posted EAP policy in multiple locations for the crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023
Resolved
All wiring and cabling carrying AC over 50 volts must be imperviously sheathed. Vessel has multiple runs of unsheathed wiring. Vessel must provide sheathed cabling for all electrical circuits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Owner made repairs/corrections to all wiring. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 January 2023
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the the purpose intended. An unauthorized repair using nonmetallic material was discovered on a leaking section of fire-main piping in the tank room. Make proper repairs and prove operational test to the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2023
Resolution: The section of the fire main piping found leaking was cropped and renewed in kind. Operation test of the fire main witnessed for approximately 10 minutes at normal system pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2022
Resolved
A submersible electric bilge pump must have a positive shutoff installed at the hull penetration. Bilge pump in rod room doesn't have a check valve, also check hardware with bilge equipment within all spaces.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2022
Resolved 16 February 2022
Resolution: Crew installed in-line check valve and tighten all hardware.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 February 2022
Resolved
Life float is approved under 160.027. 15 person life float needs to be patched IAW manufacture specs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 16 February 2022
Resolution: Crew patched raft with approved Jim buoy product.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 February 2022
Resolved
An EAP training program must be conducted for employers' supervisors. Captain has not conducted the training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 16 February 2022
Resolution: Captain completed EAP training.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 February 2022
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual exam. 02 water lights are not working.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2022
Resolved 17 February 2022
Resolution: Crew replaced 02 water lights with new approved design. Tested all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2022
Resolved
A vessel is inspected for compliance with standards of this subchapter. Fire pump piping is deteriorated and leaking. Renew in kind.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2022
Resolved 16 February 2022
Resolution: Crew replaced hoses in kind. Tested system all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 February 2022
Resolved
EPIRB on vessel must be installed to automatic float free and active. Vessels hydrostatic release for EPIRB is expired.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2022
Resolved 16 February 2022
Resolution: Vessel received new HSR and properly installed. All SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 8 February 2022
Resolved
Each credentialed crewmember must be familiar with his/her emergency duties. All crewmembers do not have valid CPR cards.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2022
Resolved 16 February 2022
Resolution: Crew completed CPR training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2022
Resolved
Each survival craft and EPIRB must be logged and tested monthly. Log test in the vessels log book.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2022
Resolved 16 February 2022
Resolution: Vessel created a new document that provides all required inspections to be logged.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 8 February 2022
Resolved
Vessel must comply to requirements issued by the FCC. Prove the DSC function of the radio is operational with vessels MMSI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 16 February 2022
Resolution: Vessel proved GPS radio is installed with MMSI for DSC function. Tested all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 February 2022
Resolved
Each item of survival equipment must be of good quality and intended to serve its purpose. Clean life floats and install longer tether line.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2022
Resolved 16 February 2022
Resolution: Life floats were cleaned and tether line was replaced with longer line. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2021
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection for m causing fire, explosion, machhinery, and personnel injury. Master reported a failure of the starboard main diesel engine's fresh water pump, while in passenger service. Trouble shoot to determine cause and make repairs to the satisfaction of the Coast Guard, prior to the carriage of passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2021
Resolved 16 September 2021
Resolution: Replaced fresh water pump and tested to the satisfaction of the coast guard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 February 2021
Resolved
Starboard side running light is inoperative.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 February 2021
Resolution: The running light was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 February 2021
Resolved
Provide coast pilot onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: Coast pilot onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 February 2021
Resolved
Properly post COI available to passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: The COI is properly posted available to passengers.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 23 February 2021
Resolved
Remove all hazmat from pilothouse and de-clutter for safety.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: The hazmat was removed and the pilothouse was cleaned up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 February 2021
Resolved
Install new instruction placard for fixed fire fighting systems.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 2 March 2021
Resolution: New placard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 February 2021
Resolved
Starboard main engine has small raw water leak. Make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: Leak was repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 February 2021
Resolved
Install/replace hardware on starboard stringer in tank room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: Hardware for stringer was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2021
Resolved
Support loose electrical wires in tank room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: Loose wires were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2021
Resolved
Portside main engine altenator wire is corroded. Clean and re-attach.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: The wire was cleaned and re-attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2021
Resolved
Provide no more than four wires for the generator battery.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: Wires were properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 February 2021
Resolved
Properly attach waterlight on lifefloats
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 February 2021
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 February 2021
Resolved
Properly rig man overboard harness.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: Harness was properly rigged.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2020
Resolved
Fire pump PSI gauge unreadable due to paint over gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: New gauge installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2020
Resolved
One adult life jacket missing clasp for donning.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: New lifejacket installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2020
Resolved
Bilge pump rod room check valve stuck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2020
Resolution: New check valve installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 February 2020
Resolved
Missing NAV RULES
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: New NAV RULES on vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 June 2019
Resolved
Engine room entry fire ext. needs pin and paint mounting bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
Resolution: New bracket installed and new pin installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 June 2019
Resolved
Smoke detector in engine room not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: New detector installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2019
Resolved
Battery terminals need to have a bus bar added due to 6 wires on on battery post.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: New terminal block installed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 June 2019
Resolved
First aid kit not CG approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: First aid kit installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 June 2019
Resolved
Metal air closure for engine room exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: New closure installed
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 June 2019
Resolved
Fwd peak ladder loose
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: Ladder bolts installed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 June 2019
Resolved
All flares expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2019
Resolution: New flares onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2019
Resolved
Teak handrails loose inside passenger cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: Handrails tightened
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 June 2019
Resolved
Life float lights not operational X2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
Resolution: Float lights tested
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 June 2019
Resolved
Life float not properly attached. When conducting abandon ship drill floats could not be launched due to inproper tying of lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2019
Resolution: Reinstalled properly
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2019
Resolved
Life jackets missing marker lights and retro tape.
Limited to 80 people total including crew and 11 child.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 2 July 2019
Resolution: Inspected all Life jackets, ALl SAT. Vsl is back to full passenger count as per COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 March 2019
Resolved
Hand rails have cracks and are damaged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 11 July 2019
Resolution: New hand rails installed and repaired
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 March 2019
Resolved
Light fixture in passenger (accomd) space was removed without authorization from CG. New lights installed were not proper type.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 March 2019
Resolved 11 July 2019
Resolution: New lights installed approved.
Lifesaving › Lifefloat › Serviceable
Issued 14 December 2017
Resolved
The vessels (four twently-two person and one twelve person) life float are all in need of replacement or repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 1 March 2018
Resolution: Replaced all 5 life floats (new), all new line, and weak links. All SAT.
Engineering › Bilge Water Management System › Strainer
Issued 14 December 2017
Resolved
Stainers are clogged and system is inoperative this date. Missing clamps and improper hoses in the system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 1 March 2018
Resolution: Tested bigle suction all SAT.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 14 December 2017
Resolved
SSDG has leaking fuel oil from nozzles and loose hardware/bracket on the high pressure lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 1 March 2018
Resolution: Tightened all SAT
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 December 2017
Resolved
Steering hose clamps are corroded in the steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: Replaced clamps with new, All SAT.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 14 December 2017
Resolved
Sewage through hull valve handle is broken and inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: New valve installed all SAT
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 14 December 2017
Resolved
Rescue platform is damaged and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2018
Resolved 1 March 2018
Resolution: Build new aluminium rescue plate form.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 December 2017
Resolved
Install marker lights on missing life-jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 1 March 2018
Resolution: Installed marker lights as required, SAT.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 December 2017
Resolved
Remark all life-jackets onboard with proper markings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: All life jacket markings are SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 14 December 2017
Resolved
Replace and remark life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: Installed new life ring and properly marked.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 December 2017
Resolved
Install laz bilge alarm cover in pilot house on main indicator panel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: Installed new LAZ alarm in PP on bridge, test SAT.
Electrical › Electric Generation Source (service) › Panelboard
Issued 14 December 2017
Resolved
Several fuses on main fuse panel at the pilot house station has missing covers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: All fuse covers are installed, SAT.
Engineering › Fuel Oil Service System › Piping
Issued 14 December 2017
Resolved
Missing clamps on the fuel oil overfill piping in crew compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 1 March 2018
Resolution: New hose clamps installed, SAT.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 2 February 2017
Resolved
Rescue Plate form bolts need to be replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: New bolts were installed on rescue platform, and platform was painted.
Engineering › Bilge Water Management System › Valve
Issued 2 February 2017
Resolved
Engine room bilge overboard did not have check valve installed. Install new check valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: Check valve was installed, all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 February 2017
Resolved
Rod room bilge alarm not working. Install new alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: Test rod room bilge alarm all test SAT.
Communications › Radio Communications › EPIRB
Issued 2 February 2017
Resolved
Hydrostatic release out of date. Replace with new.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: New hydrostatic release installed all SAT.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 February 2017
Resolved
SSD not operational.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: SSD operating properly, all SAT.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 February 2017
Resolved
FCC cert expired
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: New FFC cert issued on 21 FEB 17.
Lifesaving › Lifefloat › Float-free Link
Issued 2 February 2017
Resolved
Weak link mising tag to ID breaking strength for capacity. Install 21 or more person weak link.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: Installed new life float weak links of proper size.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 February 2017
Resolved
Missing one hose clamp. System requires two hose clamps per fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 21 February 2017
Resolution: Added three hose clamps to r/w piping.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 21 February 2016
Resolved
Double clamp raw water hose on Stbd MDE.
Due 1 March 2016
Resolved 2 March 2016
Engineering › Bilge Water Management System › Pump
Issued 21 February 2016
Resolved
Repair aft bilge pumps in steering space.
Due 1 March 2016
Resolved 2 March 2016
Lifesaving › Lifefloat › Float-free Link
Issued 21 February 2016
Resolved
renew hydrostatic release on lifefloats
Due 1 March 2016
Resolved 2 March 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 February 2016
Resolved
repair cracked weld on upper railing fwd stairway to deck two.
Due 1 March 2016
Resolved 2 March 2016
Engineering › Feedwater/Condensate Water System › Pump
Issued 21 February 2016
Resolved
Secure fresh water pump in tank room, the pump is not secured properly to the bottom framing
Due 1 March 2016
Resolved 2 March 2016