MAURY USCG vessel records Sign in
← All vessels

LOUIS TIDE

LOUIS TIDE is a 1979 offshore supply vessel. The Coast Guard has recorded 52 inspections since 1981, most recently in February 2008, along with 31 deficiencies and 1 casualty investigation in 2005.

Records from 1981 to 2008. Most recent: inspection, 12 February 2008.

Built
1979
Last inspected
12 February 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7827093 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB7060
Flag
UNITED STATES
368072000 (licence lapsed)
Maury page id
psix-50250

Inspections, by type

…with no type recorded15
Years with a record 24 calendar years (1981–2008)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it196 - Regulatory (Subpart C or D), Net Ton
289 - Regulatory (Subpart C or D), Gross Ton
946 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB7060MMSI 368072000 · cancelled · compulsorily equipped · granted 31 March 2004, cancelled 4 December 2013
WSN5044MMSI not assigned · cancelled · compulsorily equipped · granted 22 November 1994, cancelled 30 July 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAMANTHA DALE Towing Vessel · MISLE 142670 · 3 February 1994 · activity 87495

Inspection history · 52

12 February 2008 MTSA/ISPS Verification · Administrative Inspection · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3157429
13 June 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2960737
6 March 2007 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2891903
10 March 2006 Hull Examination · Internal Structural Exam · Cargo Tank Internal · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2584292
4 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2326082
27 March 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2323115
13 January 2005 MTSA/ISPS Verification · Re-Inspection · Administrative Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2274551
22 January 2004 Cargo Tank Internal · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1990319
8 February 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1485140
30 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 761871
15 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 194913
22 February 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059632
25 January 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382114
11 April 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817041
14 December 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381409
10 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 220872
1 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 135401
3 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786388
3 November 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418259
18 February 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453325
20 November 1996 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764437
22 October 1996 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 194959
27 February 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390213
16 October 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355529
18 April 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 851762
23 February 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449774
7 April 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460700
25 February 1994 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422334
3 February 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 87495
3 February 1994 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431310
3 March 1993 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1464459
6 January 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142521
30 October 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382507
19 February 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254671
12 August 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 647509
15 March 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217572
19 September 1990 Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225417
12 June 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1231649
15 May 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221452
16 February 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233130
5 April 1989 MARPOL Annex II Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 895609
17 March 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227395
12 April 1988 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1201467
17 March 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891039
25 September 1987 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011594
29 May 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316158
17 March 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019164
5 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994408
5 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979740
22 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981144
31 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277600
11 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972126

Deficiency record · 31

Accommodation/Occupational Safety › Ventilation › General
Issued 20 February 2008 Resolved
Provide vent clousure for the dryers vent.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 21 February 2008
Engineering › Bilge Water Management System › Valve
Issued 20 February 2008 Resolved
Provide wrench for forepeak reach rod and prove proper operation of the valve.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 21 February 2008
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 20 February 2008 Resolved
Prove proper operation of the port MDE high J/W temp shutdown.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 21 February 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 February 2008 Resolved
Prove proper operation of the emergency light located in STBD E/R emergency escape.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 21 February 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 January 2005 Resolved
Install bilge alarms in forward passage way as per Automation NVIC 1-78. (modified)
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 10 March 2006
Resolution: Item corrected on a privious date.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 January 2005 Resolved
Make permanent repairs to temporarily patched ballast pump discharge piping.
Action required: 705 - Other - as specified
Due 19 January 2005
Resolved 22 February 2005
Resolution: Repairs completed and tested 11 Feb 2005, as per signed letter from vsl [name withheld], dated 22 Feb 2005.
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 January 2004 Resolved
Replace all expired items in the first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2004
Resolved 26 January 2004
Communications › Internal Communications System
Issued 22 January 2004 Resolved
Change the configuration of the power supply to the blue light in the engine room and provide power from emergency circuit. LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2004
Resolved 26 January 2004
Electrical › Lighting (emergency)
Issued 22 January 2004 Resolved
Repair the light in the stbd. escape trunk from the engine room. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2004
Resolved 26 January 2004
Fire Fighting › Grease Extraction Hood
Issued 22 January 2004 Resolved
Provide a light cover for the range hood in the galley. LEGACY COMPONENT DESC: Light Cover
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 26 January 2004
Communications › Alarms/Indicators
Issued 22 January 2004 Resolved
Repair the high jacket water temp. alarm for the stbd. main engine. LEGACY COMPONENT DESC: High Water Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2004
Resolved 26 January 2004
Communications › Alarms/Indicators
Issued 22 January 2004 Resolved
Label all of the indictor lights on the alarm panel for the port main engine. LEGACY COMPONENT DESC: Machinery Alarm Panel
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 26 January 2004
Engineering
Issued 25 January 2001 Resolved
VSL REQUIRED 2 LIC. ENGINEERS OF APPROPRIATE HP RATING UNTIL VSL DEMONSTRATES FULL COMPLIANCE WITH NVIC 1-78 TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 February 2001
Resolved 22 February 2001
Fire Fighting
Issued 25 January 2001 Resolved
VSL REQ 30 MIN ROUNDS/ INSPECTION OF E/R UNTIL SAT INSTALLATION OF FIRE DETECTION SYSTEM. RESULTS OF ROUNDS MUST BE PROPERLY LOGGED AND INSTALLATION TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 February 2001
Resolved 22 February 2001
Engineering
Issued 14 December 1998 Resolved
RENEW PORT REDUCTION GEAR COOLING PUMP WATER SEAL DUE TO EXCESSIVE LEAKAGE.TAKE NECESSARY PRECAUTIONS TO ENSURE REDUCTION GEAR EXPANSION TANK DOESN'T RUN DRY.
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Deck/Cargo
Issued 27 February 1996 Resolved
Renew wasted/damaged anchor windlass cats paw. Port and STBD.
Condition: Unknown
Due 14 March 1996
Resolved 20 March 1996
Navigation
Issued 27 February 1996 Resolved
Provide new Coast Pilot. Existing is 94 edition.
Condition: Unknown
Due 29 February 1996
Resolved 8 March 1996
Navigation
Issued 27 February 1996 Resolved
Prove operation of depth flasher.
Condition: Unknown
Due 29 February 1996
Resolved 8 March 1996
Engineering
Issued 27 February 1996 Resolved
Replace missing oil hose on mud pump engine high temp shut down sensor.
Condition: Unknown
Due 29 February 1996
Resolved 8 March 1996
Navigation
Issued 27 February 1996 Resolved
Update compass deviation table.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 23 February 1995 Resolved
PROVIDE GAGING OF STERN WRAPPER BULKHEAD IN WAY OF RUDDER POSTS. ORIGINAL SCANTLINGS TO BE PROVIDED WITH GAGINGS.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Deck/Cargo
Issued 3 March 1993 Resolved
PREPARE THE VESSEL'S FOUR (4) DRY BULK TANKS AND MAKE READY FOR INSPECTION BY THOROUGHLY CLEANING AND PROVIDING A GAS-FREE/SAFE FOR ENTRY CERTIFICATE,ISSUED BY A CERTIFIED MARINE CHEMIST, AT THE NEXT DRYDOCKING EXAMINATION._x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Engineering
Issued 3 March 1993 Resolved
MAKE THE STARBOARD MAIN PROPULSION DIESEL ENGINE READY AND AVAILABLE FOR OPERATIONAL TESTS AFTER CLUTCH REPAIRS ARE COMPLETED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1993
Resolved 8 March 1993
Deck/Cargo
Issued 15 May 1990 Resolved
REPAIR OR REPLACE WILDCAT FOR STBD ANCHOR AND CHAIN DUE TO SLIPPAGE.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Engineering
Issued 15 May 1990 Resolved
REPLACE ALL PUSH ON TYPE FUEL HOSES ON ALL DIESEL ENGINES WITH CG APPROVED TYPE.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Construction/Loadline
Issued 15 May 1990 Resolved
REPAINT LOADLINE MARKINGS ON BOTH SIDES OF HULL.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990 Resolved
LABEL ALL SWITCHES ON MAIN DISTRIBUTION PANEL.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Fire Fighting
Issued 15 May 1990 Resolved
REPLACE PRESSURE GAGE ON FIRE MONITOR PUMP.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990 Resolved
FIND AND REPAIR GROUND ON MAIN DISTRIBUTION PANEL.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Engineering
Issued 15 May 1990 Resolved
REMOVE BRASS PETCOCKS ON LUBE OIL FILTERS.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Construction/Loadline
Issued 17 March 1988 Resolved
REPLACE/REPAIR PORT WTD COAMING ON EXHAUST STACK TO ENGINE ROOM ACCESS AND DEMONSTRATE WATERTIGHT INTEGRITY.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988

Casualty record · 1

27 March 2005Routine · role: Involved in a Marine Casualty · activity 2323115
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.