D M TAPPER

D M TAPPER is a 1979 passenger vessel (inspected). The Coast Guard has recorded 113 inspections since 1980, most recently in May 2026, along with 132 deficiencies.

Records from 1980 to 2026. Most recent: inspection, 7 May 2026.

Built
1979
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH5095
Flag
UNITED STATES
368356610
Maury page id
psix-50251

Inspections, by type

…with no type recorded19
Years with a record 44 calendar years (1980–2026)
The 113 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)104.0 ft × 25.1 ft × 7.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4676MMSI 368356610 · active · compulsorily equipped · granted 8 March 2024, expires 8 March 2034
WDH5095MMSI 368165000 · expired · compulsorily equipped · granted 30 May 2014, cancelled 3 August 2024
WDB6455MMSI 366053000 · cancelled · compulsorily equipped · granted 8 February 2014, cancelled 2 June 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 113

7 May 2026 Annual Inspection · Administrative Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8329231
10 February 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8308774
3 July 2025 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8174392
1 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8178607
27 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8100568
29 January 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8071861
25 July 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967177
3 June 2024 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7908775
23 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7852944
12 July 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7740561
24 March 2023 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7656249
24 March 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7658540
9 August 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7531971
18 March 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7460061
27 July 2021 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7269715
4 March 2021 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7150196
16 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7005170
6 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6993389
9 April 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6937331
26 March 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6931821
29 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6844836
3 June 2019 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6698532
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539809
21 November 2017 DAPI Audit · Deadweight Survey · Administrative Inspection · Construction Oversight · Drydock Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6317814
3 October 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6280438
3 August 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6229507
17 August 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5975277
13 October 2015 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5743462
27 October 2014 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5018644
29 May 2014 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4872185
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202851
11 July 2011 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4078730
5 July 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4070258
1 November 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3879845
18 October 2010 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3870585
17 February 2009 Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3420593
27 October 2008 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3353953
7 December 2007 Internal Structural Exam · MTSA/ISPS Verification · COI Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3111218
9 February 2006 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2692369
17 November 2005 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2513177
23 November 2004 Hull Examination · MTSA/ISPS Verification · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2246126
25 May 2004 MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2078318
7 May 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2061815
21 April 2004 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2049358
12 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2042437
5 May 2003 Deficiency Check · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1786909
16 April 2002 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1605588
2 May 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1412271
10 April 2001 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1448254
29 July 2000 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436435
28 July 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 29381
4 May 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426394
18 April 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417047
19 June 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1193580
3 May 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360848
11 May 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 791133
27 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390761
17 July 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 779652
25 April 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1451174
26 April 1996 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355786
30 May 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 95817
15 May 1995 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1239926
7 April 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 79851
14 March 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1427017
5 March 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 106248
13 February 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374206
4 October 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 870699
21 September 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1181299
24 August 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417682
29 July 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 675195
27 May 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 859320
13 April 1994 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 857283
1 September 1993 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1138594
6 August 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155293
2 November 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 935777
25 September 1992 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1254483
11 September 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 953471
28 August 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 956650
11 August 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 163570
10 October 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1250093
12 August 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 937883
12 August 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1248298
8 April 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1235473
31 October 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1241302
26 October 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1231494
15 October 1990 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918633
1 October 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 928642
12 September 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 923160
15 August 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 904502
2 July 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1226703
13 February 1990 Plan Review "T" Boat · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1215548
25 October 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1204258
20 October 1989 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195621
21 September 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 897068
14 August 1989 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042675
22 March 1989 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196149
9 November 1988 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 892348
24 August 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1353071
6 May 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345353
4 April 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301425
20 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013106
1 December 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308833
9 October 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014882
11 September 1987 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313624
22 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312637
3 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978077
22 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972556
25 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278801
28 December 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967357
25 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971375
5 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273971
29 December 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275510
31 December 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277419

Deficiency record · 132

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2026 Resolved
Vessel's fire pump failed to reach 60 psi on the pressure gauge. Troubleshoot low pressure and prove proper operation.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Vessel rep replaced gauge and pump indicated 60+ psi.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
Fore-peak compartment bilge suction valve reach rod was found to be inoperable, make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Reach rod universal joint replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
Copper generator fuel lines to and from raycor filters were found to be chaffing on the deck plating. Provide chafe protection for fuel lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Chaffing gear installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
The port generator cooling hose was found to be deteriorated at hose clamp fittings, replace hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Hose replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
Dead ended cables found in generator compartment, remove cables or terminate insides electrical box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Cables removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 May 2026 Resolved
Accommodation emergency escape deck hatch was not labeled on topside, label "EMERGENCY ESCAPE, KEEP CLEAR"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Labeling applied.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 May 2026 Resolved
Engine compartment vent closures were missing wing-nuts, provide wing-nuts for every closure bolt.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Wing-nuts provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
Port side middle goose-neck fuel tank vent found without flame screen. Provide flame screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Flame screen installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
Engine room 220V distribution panel door was missing latching device, provide means of closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Latch installed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 May 2026 Resolved
Man overboard drill was conducted and ultimately successful despite poor communication and overall lack of training. Conduct MOB drills with all crew members, covering various scenarios: port side recovery, stbd side recovery, helpless victim, and conscious victim per vessel's station bill. Send videos of training to [email withheld]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2026
Resolution: Received statement, training sign-in sheet, and videos of MOB drills
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
Unused / Unsecured battery was found on the deck plating of the generator compartment. Remove or secure the battery.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Battery was removed from compartment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2026 Resolved
Cardboard storage boxes were found in the engine room and create an additional fire risk. Remove combustible material from engine room.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Boxes were removed from the compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2025 Resolved
Pressure vessels must be tested and inspected in accordance with part 61, subpart 61.10, of this chapter. Pressure vessel missed inspection window and relief valve can not be read. Remove pressure vessel from service until an internal inspection can be completed and a relief valve set to proper relief pressure is verified installed. 46CFR176.812
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: Pressure vessel inspected and new relief valves installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 July 2024 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 46 CFR 181.425. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A ... and must be listed by an independent laboratory recognized by the Commandant. Vessel has a griddle with a grease extraction hood but no fire extinguishing system. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, not later than Jan 1, 2026
Action required: 705 - Other - as specified
Resolved 7 May 2026
Resolution: New system installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 March 2023 Resolved
Vessels on an Ocean/Coastwise route are required to have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Must install fire/smoke detectors that are integrated with all the detectors in the vessel crew state rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 14 April 2023
Resolution: Installed new smoke detectors in required area.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2022 Resolved
Ring buoy on operating station deck had retroreflective tape that was no longer retroreflective. Type II retroreflective tape should be installed in accordance with 46CFR164.018
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2022
Resolution: Received photo documentation demonstrating Type II retroreflective tape was correctly installed on the lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 August 2022 Resolved
Inflatable buoyant apparatus' must be serviced at a facility approved by the commandant no later than the month and year on the servicing sticker. The IBA on the port side operating station deck did not have servicing documentation onboard and the adjacent starboard IBA servicing expired the week prior.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 August 2022
Resolution: SSD received photo documentation of the proper servicing of the installed IBA's.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 4 March 2021 Resolved
Fixed lead ingot ballast is installed in the generator compartment. Vessel's stability letter states vessel is not fitted with any fixed ballast. Provide appropriate documentation to the Marine Safety Center to account for fixed ballast on stability letter.
Action required: 705 - Other - as specified
Resolved 11 July 2025
Resolution: Received updated copy of stability letter from MSC that incorporates fixed ballast.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 March 2021 Resolved
Grind out and re-weld 02 marked welds on port and stbd bow.
Action required: 705 - Other - as specified
Resolved 9 March 2021
Resolution: Welds were ground out and new welds were applied.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 July 2020 Resolved
VESSEL'S CURRENT LIFESAVING CAPACITY IS 125 PEOPLE DUE TO ONE OF THE IBAS CURRENTLY BEING SERVICED. VESSEL IS LIMITED TO TOTAL OF 125 PEOPLE ONBOARD UNTIL IBA IS RETURNED FROM SERVICING.
Action required: 705 - Other - as specified
Due 16 August 2020
Resolved 6 October 2020
Resolution: All IBAs returned to vessel. [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2020 Resolved
ROTATING BELT ON #4 MAIN ENGINE IS EXPOSED CAUSING POTENTIAL PERSONNEL HAZARD. MUST PROVIDE GUARD ON BELT TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 22 July 2020
Resolution: Pic emailed to inspector, [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2020 Resolved
THERE IS NO PROTECTIVE COVERING ON GAUGE TO MAIN FIRE PUMP. MUST PROVIDE COVER OR NEW GAUGE TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 22 July 2020
Resolution: pic emailed to inspector...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020 Resolved
MUST PROVIDE BLANK COVER TO OPEN SECTION OF DISTRIBUTION PANEL IN ENGINE ROOM TO SATISFACTION OF CG MARINE INSPECTOR
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 22 July 2020
Resolution: pic emailed to inspector...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Main electrical distrubution panel had an opening without a blank or a breaker. Install blank as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Blanks installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove 2 electrical strips on portside wheel house and install required junction boxes for navigation equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Power strips removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Permenantly mount floating switch located in A/C Compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Switch mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 30 January 2020
Resolved 2 December 2019
Resolution: A/C 1 line provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2019 Resolved
Reinstall exterior waterproof outlet (220V) at A/C unit aft of bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 1 July 2019
Resolution: All wiring and outlet removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2019 Resolved
Replace fire nozzles with CG approved nozzles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 1 July 2019
Resolution: Nozzles replaced with proper type.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 June 2019 Resolved
Repair installed PA system for accommodation spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 1 July 2019
Resolution: PA system operated properly.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Communications › Public Address System › Broadcast Location
Issued 17 August 2016 Resolved
Make PA system audible in accomadation spaces and throughout vessel.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Made PA system audible in accomadation spaces and throughout vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 August 2016 Resolved
Provide captain or crew with marine radio operator permit.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 29 September 2016
Resolution: Captain provided marine radio operator permit.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 17 August 2016 Resolved
Provide latch to electrical panel in Engine Room.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Provided latch to electrical panel in Engine Room.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 August 2016 Resolved
Mount loose E-outlet in Engine Room.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Mounted loose E-outlet in Engine Room.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 August 2016 Resolved
Make open sea water piping in engine room secure.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Made open sea water piping in engine room secure.
Engineering › Freshwater System (intermediary cooling) › Storage Tank
Issued 17 August 2016 Resolved
Provide bracket to fresh water tank.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Provided bracket to fresh water tank.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 October 2015 Resolved
Generator light cover is broken.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 October 2015 Resolved
Guard missing from rotating gear on port side generator.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Construction/Loadline › Structures › Deck Plating
Issued 13 October 2015 Resolved
Starboard corner gunnel must be cropped and renewed due to damage from marine casualty.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Engineering › Lubricating Oil Service System › Pump
Issued 13 October 2015 Resolved
Seal on impeller pump is excessively leaking.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 13 October 2015 Resolved
Various weld cracks found throughout vessel. 09 in forward peak, 05 aft rudder room, 03 Generator room.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Engineering › Compressed Air System (control) › Piping
Issued 13 October 2015 Resolved
6FT of piping for air compressor was excessively wasted.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 13 October 2015 Resolved
Port and Starboard exhaust leaks must be repaired for main diesel engines.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 October 2015 Resolved
Sewage pipe below forward cabin in aft port side compartment was leaking.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 October 2015 Resolved
Metal support brackets missing for electrical; wiring in forward cabin aft port compartment.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 11 January 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 October 2010 Resolved
Vessel is going out of service for the winter. Drills will be conducted with a CGMI prior to the carriage of passengers.
Action required: 705 - Other - as specified
Due 21 May 2011
Resolved 12 July 2011
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 October 2010 Resolved
Five lifejackets were found to be in unsuitable condition and were condemned. This left the vessel five lifejackets short of its complement.
Due 21 October 2010
Resolved 21 October 2010
Resolution: Replacement lifejackets were brought aboard the vessel from a supply of spares.
Fire Fighting › Fire Hoses › Condition
Issued 29 October 2008 Resolved
Replace stbd side fire hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 29 October 2008
Resolution: Replaced, test sat
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 October 2008 Resolved
Renew spool piece to sea valve connection. Pipe threads on spool piece wasted due to galvanic corrosion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Resolution: Rethreaded pipe at good metal, reinstalled valve.
Electrical › Electric Supply System (service)
Issued 5 May 2003 Resolved
Install ship service generator battery cut-off switch. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 15 May 2003
Engineering › Fuel Oil Service System
Issued 5 May 2003 Resolved
Strip water from fuel oil tanks. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 15 May 2003
Engineering
Issued 5 May 2003 Resolved
Conduct test of all machinery alarms. LEGACY COMPONENT DESC: Alarms
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 15 May 2003
Construction/Loadline › Hull
Issued 24 April 2002 Resolved
Found multiple cracked welds. Vessel rep is going to provide repair proposal. LEGACY COMPONENT DESC: Weld
Condition: Placed in Improper Service
Due 15 May 2002
Resolved 7 May 2002
Engineering › Compressed Air System (start air) › Valve
Issued 16 April 2002 Resolved
Air compressor releif valves do not operate. Repair or replace releif valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Corrected to the satisfaction of attending Coast Guard Marine Inspector
Construction/Loadline › Structures › Ventilators
Issued 16 April 2002 Resolved
Provide watertight integrity to air compressor / generator room. Goose neck vent missing plate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of attending Coast Guard marine inspector
Engineering › Bilge Water Management System › Manifold
Issued 16 April 2002 Resolved
Provide plug to unused valve of the bilge manifold.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 April 2002 Resolved
Fire extinguisher not mounted in the engine room, (loose).
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard Marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2002 Resolved
Remove or properly secure "dead end" wiring in the engine room and crew berthing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard Marine Inspector
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 April 2002 Resolved
Provide life jacket donning placards for all types of lifejackets carried on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 16 April 2002 Resolved
Blank out unused portions of bridge alarm panel
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of the attending coast guard marine inspector.
Construction/Loadline › Structures
Issued 16 April 2002 Resolved
Multiple cracks in aft / stern railing. Vessel will not carry passengers on stern/aft while underway until railing is repaired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 3 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline
Issued 3 May 1999 Resolved
CLEAN DEBRIS FROM FOREPEAK BILGE SUCTION STRAINER.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Navigation
Issued 3 May 1999 Resolved
CORRECT COAST PILOT UP TO DATE.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Lifesaving
Issued 3 May 1999 Resolved
CONDUCT FIRE, MAN OVERBOARD AND ABANDON SHIP DRILLS WHILE UNDERWAY IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
REMOVE DEADHEADED CABLE FROM FOREPEAK.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Accommodation/Occupational Safety
Issued 3 May 1999 Resolved
REMOVE, CLEAN AND REINSTALL LEAKING FLEX HOSE CONNECTORS FOR MSD PIPING IN MSD VOID.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
ENCLOSE EXPOSED CABLE SPLICE IN A BOX, PORT VOID OUTBOARD OF BELOW DECK SHOWER.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Engineering
Issued 3 May 1999 Resolved
RENEW KINKED EXHAUST COOLING WATER HOSE ON PORT MDE.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
REMOVE DEADHEADED CABLE FROM ENGINEROOM, PORT SIDE OF FWD BULKHEAD.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Unknown
Issued 3 May 1999 Resolved
PROVIDE A PASSENGER SAFETY ORIENTATION PER 185.60
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Engineering
Issued 3 May 1999 Resolved
LABEL FUEL OIL REMOTE SHUTOFF.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Construction/Loadline
Issued 3 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS WITH VISUAL AND AUDIBLE SIGNAL IN LAZARETTE, GENERATOR ROOM, AND MSD VOID.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Engineering
Issued 3 May 1999 Resolved
INSTALL HANDLES ON PORT-CENTER AND STBD-CENTER MDE RAW WATER SEA VALVES.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
INSTALL PERMANENT WIRING FOR ENGINE BLOCK HEATERS ON ALL 4 MDES.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
INSTALL BLANK OVER GAP IN PORT 110V PANEL AT AFT BULKHEAD IN ENGINEROOM.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
SECURE POTABLE WATER PRESSURE SWITCH TO BULKHEAD.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Engineering
Issued 3 May 1999 Resolved
SECURE OIL LEAKS FROM LOWER OIL FILTER ON BOTH PORT-CENTER, AND STBD-CENTERMDES.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Electrical
Issued 3 May 1999 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING BELOW DECKS. (TOO DIM)
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Fire Fighting
Issued 3 May 1999 Resolved
LABEL PORT AND STARBOARD FIRE PUMP REMOTE CONTROL STATIONS.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Fire Fighting
Issued 3 May 1999 Resolved
RENEW AND PROVE PROPER OPERATION OF FIRE PUMP OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 17 May 1999
Resolved 18 May 1999
Lifesaving
Issued 27 April 1998 Resolved
POST LIFERAFT LAUNCHING INSTRUCTIONS AT OR NEAR INFLATABLE BUOYANT APPARATUS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 27 April 1998 Resolved
PROVIDE VESSEL MAN OVERBOARD RESCUE PLATFORM OR RESCUE BOAT PRIOR TO CARRYING PASSENGERS BUT NO LATER THAN 09MAY98.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Fire Fighting
Issued 27 April 1998 Resolved
PROVE SERVICING OF PORTABLE FIRE EXT. IN CREW AND MASTERS QUARTERS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 27 April 1998 Resolved
PROVIDE 5 ADDITIONAL ADULT LIFEJACKETS TO MEET REQUIREMENTS OF COI. TOTAL PERSONS ONBOARD LIMITED TO 147 UNTIL LIFEJACKETS ARE PROVIDED.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Electrical
Issued 13 February 1995 Resolved
REMOVE OR PROPERLY INSTALL THE TWO DEAD-END CABLES LOCATED ADJACENT TO MARINE SANITATION DEVICE.
Condition: Unknown
Due 13 February 1995
Resolved 13 February 1995
Fire Fighting
Issued 24 August 1994 Resolved
STENCIL FIRE AXE WITH VESSEL NAME.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Construction/Loadline
Issued 24 August 1994 Resolved
FREE UP FOREPEAK VALVE FOR BILGE LINE AND TEST OPERATION OF THE BILGE PUMP FROM THE FORPEAK.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Engineering
Issued 24 August 1994 Resolved
INSTALL FLAME IMPINGEMENT BOWL IN WAY OF #3 ENGINE RAYCOR FILTER.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Electrical
Issued 24 August 1994 Resolved
INSTALL BLANK IN POWER DISTRIBUTION PANEL IN ENGINE ROOM.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Fire Fighting
Issued 24 August 1994 Resolved
PROVIDE A PORTABLE HAND OPERATED FIRE PUMP WHICH OPERATES IN ACCORDANCE WITH 46CFR 181.10-5, TO INCLUDE SUFFICIENT HOSE TO REACH THE WATER AND TO REACH FLAMES ANYWHERE ABOARD THE VESSEL.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 24 August 1994 Resolved
SERVICE HYDROSTATIC RELEASES FOR BOTH BOUYANT APPARATUS.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Construction/Loadline
Issued 24 August 1994 Resolved
CLEAN OILY BILGES IN WAY OF ENGINE ROOM.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Construction/Loadline
Issued 24 August 1994 Resolved
RENEW AS ORIGINAL BROKEN RAIL PORT SIDE AFT, AND BOARDING GATE PORT SIDE AFT. THIS AREA IS TO BE MADE INACCESSABLE TO PASSENGERS UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Electrical
Issued 24 August 1994 Resolved
REPAIR INOPERATIVE EMERGENCY LIGHT ON BRIDGE
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Unknown
Issued 24 August 1994 Resolved
PROVIDE PROOF OF PARTICIPATION IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Navigation
Issued 24 August 1994 Resolved
PROVIDE UP-TO-DATE COMPASS DEVIATION CARD.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Engineering
Issued 24 August 1994 Resolved
REPLACE FUEL TANK VENT SCREENS PORT & STBD WITH 30X30 MESH.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 6 August 1993 Resolved
PROVIDE LIFE PRESERVERS AND STOWAGE CONVENIENTLY ACCESSIBLE FOR PASSENGERS_x001C_ON THE MAIN DECK. NUMBER OF LIFE PRESERVERS TO BE THE SAME TOTAL NUMBER_x001C_ OF PASSENGERS CARRIED ON THE MAIN DECK. _x001C_ _x001C_
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Lifesaving
Issued 6 August 1993 Resolved
PROVIDE SEPARATE STOWAGE FOR CHILD-SIZE LIFE PRESERVERS. _x001C_ _x001C_
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Electrical
Issued 11 September 1992 Resolved
Replace emergency lighting cover w/ appropriate globe at the lower forward galley location.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Documentation
Issued 12 August 1991 Resolved
PROVIDE COPY OF UPDATED FCC EXEMPTION CERTIFICATE, ISSUED UNDER THE PROVISION OF THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEAS, 1974, PRIOR TO 29 OCTOBER 1991.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Electrical
Issued 12 September 1990 Resolved
REPAIR GROUND AMMETER TO READ ZERO, UNLESS THE TEST BUTTON IS PUSHED DURINGTEST.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990 Resolved
PROVIDE CLAMPS TO HOLD THE LIGHT FIXTURE COVERS IN THE ENGINE ROOM.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990 Resolved
TEST OVERSPEED TRIP ON BOTH SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
REPAIR SMALL HOLE IN PORT MAIN DIESEL EXHAUST PIPING.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990 Resolved
PROVIDE SUITABLE MATERIAL RESISTANT TO DETERIORATING ACTION BY THE ELECTROLYTE ON ALL BATTERY STOWAGE BOXES AFT OF THE PILOT HOUSE.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Documentation
Issued 12 September 1990 Resolved
PROVIDE A VALID COPY OF FCC COMMUNICATION ACT SAFETY RADIO TELEPHONE CERTIFICATE ON BOARD.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Construction/Loadline
Issued 12 September 1990 Resolved
PROVIDE WATERTIGHT STUFFING TUBES IN WAY OF PORTSIDE CABLE & PIPING RUNS INTHE ENGINE ROOM.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990 Resolved
CLEAN GENERATOR WINDINGS ON BOTH SERVICE GENERATORS.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
PROVIDE LAGGING INSULATIONS ON THE STARBOARD MAIN DIESEL ENGINE TURBO EXHAUST LINE.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Lifesaving
Issued 21 September 1989 Resolved
LABEL STOWAGE FOR THE CHILDREN'S LIFE PRESERVERS.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Accommodation/Occupational Safety
Issued 21 September 1989 Resolved
REPLACE CRACKED GLASS WINDOW #7 PORT SIDE MAIN DECK LEVEL PASSENGER ACCOMMODATION.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Unknown
Issued 21 September 1989 Resolved
PROVIDE GLOBE COVERS FOR THE OVERHEAD LIGHTS IN THE ENGINEROOM AND IN THE PASSAGEWAY, CENTER OF FUEL OIL TANKS.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Fire Fighting
Issued 21 September 1989 Resolved
HYDROTEST ONE(1) B-II CO2 PORTABLE FIRE EXITNGUISHER.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Engineering
Issued 21 September 1989 Resolved
INSTALL PROTECTIVE COVERS TO THE FOUR(4) MAIN PROPULSION DIESEL ENGINES ROTATING COUPLINGS AND SHAFTS.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Engineering
Issued 21 September 1989 Resolved
REPAIR PORT MAIN ENGINES' TACHOMETERS IN THE PILOTHOUSE.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Construction/Loadline
Issued 14 August 1989 Resolved
INSTALL CHECK OR STOP VALVE SHOWER DRAIN OVERBOARD PORTSIDE.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Construction/Loadline
Issued 14 August 1989 Resolved
GOUGE OUT AND REWELD CRACKS IN WELDS AS MARKED IN FOREPEAK. A/C COMPT PORT AND STBD SHELLS BEHIND JOINER WORK, PORTSIDE FUEL TANK COMPTS AND STEERING COMPT.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Construction/Loadline
Issued 14 August 1989 Resolved
CROP AND RENEW OR FAIR UP AND REWELD FRAME IN ENG RM AND FRAME SIDE SHELL LONG, DECK LONG AND TRANSOM VERTICAL STIFFENER IN STEERING COMPT.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Construction/Loadline
Issued 14 August 1989 Resolved
REPAIR CRACK PORTSIDE SPRAY SHIELD.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Construction/Loadline
Issued 14 August 1989 Resolved
RENEW MISSING DRAFT MARKS 6' FWD PORT, 5' STBD AFT.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Engineering
Issued 14 August 1989 Resolved
RENEW OUTBOARD STBD PROP WITH PROPER BLADE SHAPE, PITCH AND ROTATION.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Deck/Cargo
Issued 14 August 1989 Resolved
REPAIR ANCHOR WINDLASS TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Navigation
Issued 14 August 1989 Resolved
REPAIR RUDDER POST BEARING PORT RUDDER.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Navigation
Issued 14 August 1989 Resolved
REPLACE CAP STBD RUDDER POST BEARING.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Construction/Loadline
Issued 14 August 1989 Resolved
REPLACE HOSE AND CLAMPS PORTSIDE OF HOLDING TANK UNDER GALLEY.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Construction/Loadline
Issued 14 August 1989 Resolved
REPLACE SOFT PATCHED SPOOL PIECE GARBAGE GRINDER OVERBOARD DISCHARGE.
Condition: Unknown
Due 14 August 1989
Resolved 14 August 1989
Accommodation/Occupational Safety
Issued 11 September 1987 Resolved
PROVIDE APPROVED PRINTS FOR NEW AIR CONDITIONING SYSTEM.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Accommodation/Occupational Safety
Issued 11 September 1987 Resolved
PROVE PROPER OPERATION OF RELIEF VALVES ON THE PORT AND STARBOARD AIR RECEIVERS.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 11 September 1987 Resolved
PROVE PROPER OPERATION OF ENG. ALARM MONITOR PANELS.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Documentation
Issued 11 September 1987 Resolved
PROVIDE CURRENT STABILITY LETTER FOR M/V HARBOR COMMUTER X.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.