MAURY USCG vessel records
← All vessels

D M TAPPER

Built
1979
Last inspected
7 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5095
Flag
UNITED STATES
Maury page id
psix-50251

Documentation record

Registered dimensions (L × B × D)104.0 ft × 25.1 ft × 7.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 27

7 May 2026 Annual Inspection · Administrative Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8329231
10 February 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8308774
3 July 2025 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8174392
1 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8178607
27 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8100568
29 January 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8071861
25 July 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967177
3 June 2024 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7908775
23 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7852944
12 July 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7740561
24 March 2023 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7656249
24 March 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7658540
9 August 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7531971
18 March 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7460061
27 July 2021 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7269715
4 March 2021 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7150196
16 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7005170
6 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6993389
9 April 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6937331
26 March 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6931821
29 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6844836
3 June 2019 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6698532
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539809
21 November 2017 DAPI Audit · Deadweight Survey · Administrative Inspection · Construction Oversight · Drydock Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6317814
3 October 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6280438
3 August 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6229507
17 August 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5975277

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2026 Resolved
Vessel's fire pump failed to reach 60 psi on the pressure gauge. Troubleshoot low pressure and prove proper operation.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Vessel rep replaced gauge and pump indicated 60+ psi.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
Fore-peak compartment bilge suction valve reach rod was found to be inoperable, make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Reach rod universal joint replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
Copper generator fuel lines to and from raycor filters were found to be chaffing on the deck plating. Provide chafe protection for fuel lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Chaffing gear installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
The port generator cooling hose was found to be deteriorated at hose clamp fittings, replace hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Hose replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
Dead ended cables found in generator compartment, remove cables or terminate insides electrical box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Cables removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 May 2026 Resolved
Accommodation emergency escape deck hatch was not labeled on topside, label "EMERGENCY ESCAPE, KEEP CLEAR"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Labeling applied.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 May 2026 Resolved
Engine compartment vent closures were missing wing-nuts, provide wing-nuts for every closure bolt.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Wing-nuts provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 May 2026 Resolved
Port side middle goose-neck fuel tank vent found without flame screen. Provide flame screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Flame screen installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
Engine room 220V distribution panel door was missing latching device, provide means of closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
Resolution: Latch installed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 May 2026 Resolved
Man overboard drill was conducted and ultimately successful despite poor communication and overall lack of training. Conduct MOB drills with all crew members, covering various scenarios: port side recovery, stbd side recovery, helpless victim, and conscious victim per vessel's station bill. Send videos of training to [email withheld]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2026
Resolution: Received statement, training sign-in sheet, and videos of MOB drills
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
Unused / Unsecured battery was found on the deck plating of the generator compartment. Remove or secure the battery.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Battery was removed from compartment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2026 Resolved
Cardboard storage boxes were found in the engine room and create an additional fire risk. Remove combustible material from engine room.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Boxes were removed from the compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2025 Resolved
Pressure vessels must be tested and inspected in accordance with part 61, subpart 61.10, of this chapter. Pressure vessel missed inspection window and relief valve can not be read. Remove pressure vessel from service until an internal inspection can be completed and a relief valve set to proper relief pressure is verified installed. 46CFR176.812
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: Pressure vessel inspected and new relief valves installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 July 2024 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 46 CFR 181.425. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A ... and must be listed by an independent laboratory recognized by the Commandant. Vessel has a griddle with a grease extraction hood but no fire extinguishing system. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, not later than Jan 1, 2026
Action required: 705 - Other - as specified
Resolved 7 May 2026
Resolution: New system installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 March 2023 Resolved
Vessels on an Ocean/Coastwise route are required to have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Must install fire/smoke detectors that are integrated with all the detectors in the vessel crew state rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 14 April 2023
Resolution: Installed new smoke detectors in required area.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2022 Resolved
Ring buoy on operating station deck had retroreflective tape that was no longer retroreflective. Type II retroreflective tape should be installed in accordance with 46CFR164.018
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2022
Resolution: Received photo documentation demonstrating Type II retroreflective tape was correctly installed on the lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 August 2022 Resolved
Inflatable buoyant apparatus' must be serviced at a facility approved by the commandant no later than the month and year on the servicing sticker. The IBA on the port side operating station deck did not have servicing documentation onboard and the adjacent starboard IBA servicing expired the week prior.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 August 2022
Resolution: SSD received photo documentation of the proper servicing of the installed IBA's.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 4 March 2021 Resolved
Fixed lead ingot ballast is installed in the generator compartment. Vessel's stability letter states vessel is not fitted with any fixed ballast. Provide appropriate documentation to the Marine Safety Center to account for fixed ballast on stability letter.
Action required: 705 - Other - as specified
Resolved 11 July 2025
Resolution: Received updated copy of stability letter from MSC that incorporates fixed ballast.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 March 2021 Resolved
Grind out and re-weld 02 marked welds on port and stbd bow.
Action required: 705 - Other - as specified
Resolved 9 March 2021
Resolution: Welds were ground out and new welds were applied.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 July 2020 Resolved
VESSEL'S CURRENT LIFESAVING CAPACITY IS 125 PEOPLE DUE TO ONE OF THE IBAS CURRENTLY BEING SERVICED. VESSEL IS LIMITED TO TOTAL OF 125 PEOPLE ONBOARD UNTIL IBA IS RETURNED FROM SERVICING.
Action required: 705 - Other - as specified
Due 16 August 2020
Resolved 6 October 2020
Resolution: All IBAs returned to vessel. [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2020 Resolved
ROTATING BELT ON #4 MAIN ENGINE IS EXPOSED CAUSING POTENTIAL PERSONNEL HAZARD. MUST PROVIDE GUARD ON BELT TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 22 July 2020
Resolution: Pic emailed to inspector, [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2020 Resolved
THERE IS NO PROTECTIVE COVERING ON GAUGE TO MAIN FIRE PUMP. MUST PROVIDE COVER OR NEW GAUGE TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 22 July 2020
Resolution: pic emailed to inspector...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020 Resolved
MUST PROVIDE BLANK COVER TO OPEN SECTION OF DISTRIBUTION PANEL IN ENGINE ROOM TO SATISFACTION OF CG MARINE INSPECTOR
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 22 July 2020
Resolution: pic emailed to inspector...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Main electrical distrubution panel had an opening without a blank or a breaker. Install blank as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Blanks installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove 2 electrical strips on portside wheel house and install required junction boxes for navigation equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Power strips removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Permenantly mount floating switch located in A/C Compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Switch mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 30 January 2020
Resolved 2 December 2019
Resolution: A/C 1 line provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2019 Resolved
Reinstall exterior waterproof outlet (220V) at A/C unit aft of bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 1 July 2019
Resolution: All wiring and outlet removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2019 Resolved
Replace fire nozzles with CG approved nozzles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 1 July 2019
Resolution: Nozzles replaced with proper type.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 June 2019 Resolved
Repair installed PA system for accommodation spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 1 July 2019
Resolution: PA system operated properly.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Communications › Public Address System › Broadcast Location
Issued 17 August 2016 Resolved
Make PA system audible in accomadation spaces and throughout vessel.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Made PA system audible in accomadation spaces and throughout vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 August 2016 Resolved
Provide captain or crew with marine radio operator permit.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 29 September 2016
Resolution: Captain provided marine radio operator permit.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 17 August 2016 Resolved
Provide latch to electrical panel in Engine Room.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Provided latch to electrical panel in Engine Room.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 August 2016 Resolved
Mount loose E-outlet in Engine Room.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Mounted loose E-outlet in Engine Room.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 August 2016 Resolved
Make open sea water piping in engine room secure.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Made open sea water piping in engine room secure.
Engineering › Freshwater System (intermediary cooling) › Storage Tank
Issued 17 August 2016 Resolved
Provide bracket to fresh water tank.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 6 September 2016
Resolution: Provided bracket to fresh water tank.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.