Records from 1981 to 2021. Most recent: inspection, 2 December 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
2 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7361392
25 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7357402
5 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169166
22 January 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6893695
8 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6658217
30 January 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6617278
6 March 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6368550
21 February 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358781
25 January 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6077225
13 January 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6071993
1 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5824937
8 October 2014
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5001627
5 January 2011
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3921066
21 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3874316
21 January 2010
COI Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3667905
17 December 2008
Re-Inspection · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3382225
24 April 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3177722
9 March 2007
Hull Examination · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2885030
19 April 2006
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2640367
26 January 2005
Hull Examination · COI Inspection · Deficiency Check · Inclining Experiment · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2281344
12 January 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047994
8 March 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 801771
12 February 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384033
12 January 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448995
12 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114076
13 January 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392591
31 January 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363495
18 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363493
25 January 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446165
10 February 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373980
9 February 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415792
14 February 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268280
18 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926176
2 August 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240055
26 February 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230536
3 March 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200753
4 January 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352743
23 September 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043890
11 March 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034731
11 March 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1302537
12 March 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327033
21 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998650
30 September 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989748
29 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983358
4 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977266
23 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971215
13 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279179
21 May 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276525
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 January 2020
Resolved
Piping and fittings conveying vapors which exceed 150 degrees must be insulated. Missing sections on MDE’s and Generators.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
Resolution: Vessel provided evidence of laggaing over exposed hot surfaces.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 January 2020
Resolved
Union on ballast / fire main piping leaking near pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2020
Resolved 22 January 2020
Resolution: Vsl rep provided video evidence of pump running with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 January 2020
Resolved
Exposed hazards must be properly protected by guards. Guards missing around MDE shafts and not properly secured on front of STBD MDE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2020
Resolved 22 January 2020
Resolution: Vsl provided evidence of machinery guards in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 January 2020
Resolved
Ground detection required on switchboard. Test button stuck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 January 2020
Resolution: Vsl provided evidence of fixing stuck ground detection buttons.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 April 2019
Resolved
Hydrostatic release for EPIRB was expired. Vsl will need to replace with new hydrostatic release.
OLD T Reference: 180.40
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2019
Resolved 9 April 2019
Resolution: New Hydrostatic release purchased
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 April 2019
Resolved
Dirty Oil pump was OOC. Needs serviced to be in working condition.
Old T Reference: 182.10-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2019
Resolved 9 April 2019
Resolution: Technician serviced OWS and it is operating without issues
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 March 2018
Resolved
Port running light is not working due to a bad bulb and needs to be replaced prior to navigating the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2018
Resolved 6 March 2018
Resolution: Bulb was replaced. All sat.
Communications › Radio Communications › Emergency Source of Power
Issued 6 March 2018
Resolved
VHF radio with DSC was not powered by the emergency power system and needs to be corrected prior to operating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 7 March 2018
Resolution: Corrected. All sat.
Electrical › Electric Supply System (service) › Cable
Issued 1 March 2016
Resolved
Exposed wires on battery charger shall be contained in a junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 March 2016
Resolution: All bare wires were put in junction box.
Communications › Radio Communications › Satellite Communications Capability
Issued 1 March 2016
Resolved
Vessel did not comply with 47 CFR 80.905(a)3. All small passenger vessels carrying more than 6 personnel are required DSC.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 March 2016
Resolution: DSC was hooked up by qualified tech.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 1 March 2016
Resolved
Line throwing gun was missing from vessel. Vessel is not suitable for offshore standby service until the line throwing gun is on vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 March 2016
Resolution: A new line-throwing gun was placed aboard the vessel as part of the required stanby vessel equipment.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 1 March 2016
Resolved
Machinery guard on starboard main engine was damaged. Rotating machinery on engine must be properly protect. Guard was repaired on the spot and deficicency was cleared.
Condition: Improper/Lack of Maintenance
Due 1 April 2016
Resolved 2 March 2016
Resolution: Guard was repair on the spot.
Stability › Weathertight Integrity › General
Issued 8 October 2014
Resolved
Aft control shack windows were damaged. Required vessel to replace.
Due 8 November 2014
Resolved 14 January 2015
Resolution: Windows replaced.
Communications › Radio Communications › Emergency Source of Power
Issued 5 January 2011
Resolved
Single side band was not operable on e-power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2011
Resolution: Battery was exchanged and SSB operational.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 January 2011
Resolved
Placed an e-lighting in the galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2011
Resolution: Place battery operated lantern in the galley on e-power.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 January 2011
Resolved
Need an emergency escape label on door of accommodation space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2011
Resolution: Stenciled emergency escape on berthing door accommodation.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 April 2006
Resolved
Include rough weather and flooding in Emergency Instructions.
Due 10 May 2006
Resolved 2 May 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 April 2006
Resolved
Log inspection and testing of EPIRB and lifesaving equipment.
Due 10 May 2006
Resolved 2 May 2006
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 April 2006
Resolved
Post Employee Assistance Program information & phone numbers.
Due 10 May 2006
Resolved 2 May 2006
Fire Fighting › Structural - Horizontal Zones › General
Issued 19 April 2006
Resolved
Fill gaps in wire run from cargo room to galley with approved material.
Due 10 May 2006
Resolved 2 May 2006
Engineering › Steering Gear System › Fastener
Issued 19 April 2006
Resolved
Ram steering pin loose, mount is worn. Rework or replace mount.
Due 10 May 2006
Resolved 2 May 2006
Resolution: Mount was filled/reworked for a tight fit.
Stability › Incline Test › General
Issued 25 February 2005
Resolved
Provide copy of approved stability letter from the Marine Safety Center.
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 6 April 2005
Resolution: Received copy of approved Stability Letter.
Construction/Loadline › Hull › Hull Plating
Issued 25 February 2005
Resolved
Provide copy of structural drawings with approval letter and resolution of any comments from the Marine Safety Center.
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 6 April 2005
Resolution: Received copy of approved drawings.
Accommodation/Occupational Safety
Issued 12 February 1999
Resolved
PROPERLY SECURE PANGE IN GALLEY.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Engineering
Issued 12 February 1999
Resolved
PROVE PROPER OPERATION OF PROPULSION ENGINE SHUTDOWNS FROM MAIN ENGINE OPERATING STATION.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Electrical
Issued 12 February 1999
Resolved
INSTALL NEW DIRECTORY CARD FOR ENGINEROOM DISTRIBUTION PANEL.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Construction/Loadline
Issued 12 February 1999
Resolved
PROVE PROPER OPERATION OF WATERTIGHT DOOR ON MAIN DECK LEADING TO ENGINEROOM.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Navigation
Issued 12 February 1999
Resolved
INSTALL 02 NEW FLEX HOSES, ON STEERING PUMP #2 AND SYSTEM RETURN RESERVOIR.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Engineering
Issued 12 February 1999
Resolved
INSTALL EXHAUST LAGGING ON BOTH MDE EXHAUST ELBOWS AT MAINFOLD.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Engineering
Issued 12 February 1999
Resolved
DOUBLE NUT BOTH MDE MARINE GEAR LINKAGE CONNECTIONS.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Engineering
Issued 12 February 1999
Resolved
INSTALL NUT AND LOCKWASHER ON STARBOARD MDE FWD ENGINE MOUNTS.
Condition: Unknown
Due 12 March 1999
Resolved 17 February 1999
Electrical
Issued 12 February 1999
Resolved
MOUNT JUNCTION BOW TO OVERHEAD ABOVE FIRE PUMP ENGINE.
Condition: Unknown
Due 12 March 1999
Resolved 17 February 1999
Accommodation/Occupational Safety
Issued 12 February 1999
Resolved
MAKE PERMANENT REPAIRS TO LEAKING SEWAGE PUMP PACKING GLAND AND SUCTION VALVE.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Engineering
Issued 12 February 1999
Resolved
MAKE PROPER REPAIRS TO PORT MAIN DIESEL ENGINE FORWARD PULEY GUARD.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Navigation
Issued 12 February 1999
Resolved
PRIOR TO VESSEL OPERATING, PROVIDE SERVICING TECHNICIANS REPORT FOR SINGLE SIDE BAND RADIO. REPORT CAN BE FAXED TO HARVEY CANAL INSPECTIONS AT [phone withheld].
Condition: Unknown
Due 1 March 1999
Resolved 17 February 1999