MAURY USCG vessel records Sign in
← All vessels

SOUTHWESTERN 154

SOUTHWESTERN 154 is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 21 inspections since 1981, most recently in October 1997, along with 62 deficiencies.

Records from 1981 to 1997. Most recent: inspection, 3 October 1997.

Built
1979
Last inspected
3 October 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8756540 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-50272

Inspections, by type

…with no type recorded9
Years with a record 12 calendar years (1981–1997)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2272 - Regulatory (Subpart C or D), Net Ton
2272 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

3 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122461
10 May 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890385
25 May 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1170606
20 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1228320
17 January 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931141
17 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995455
16 February 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332646
5 March 1987 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314680
13 January 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1005564
30 October 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1016459
13 March 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 992016
12 January 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 993456
26 November 1985 COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 995188
2 April 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1288689
7 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1284357
11 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974875
8 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966033
20 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274759
7 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272598
4 October 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970675
6 October 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970598

Deficiency record · 62

Navigation
Issued 25 May 1994 Resolved
REPLACE CRACKED PLASTIC LENS IN FORWARD OBSTRUCTION LIGHT.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Navigation
Issued 25 May 1994 Resolved
PROVIDE AND INSTALL PROPER LAMP HOLDERS AND LAMPS ON VESSEL RUNNING LIGHTS
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 25 May 1994 Resolved
COMPLETE THE REQUIREMENTS OF THE COAST GUARD INSPECTION DATED 17JAN91 ITEM 12, TO SUBMIT PLANS FOR APPROVAL OF GALLEY HOOD AND DEEP FAT FRYER FIXED FIRE FIGHTING SYSTEM. NEW ARRANGEMENTS SHOULD BE IN FIRE AND SAFETY PLAN.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Lifesaving
Issued 25 May 1994 Resolved
PROVIDE ON BOARD A SOLAS APPROVED ROCKET TYPE LINE THROWING APPLIANCE, THE PRESENT SHOUDLER TYPE APPLIANCE IS TO BE RETAINED ON BOARD UNTIL THE REPLACEMENT (ROCKET TYPE) IS ON BOARD.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 25 May 1994 Resolved
PROVIDE AND SUBMITED AN APPROVED (USCG) VESSEL CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Lifesaving
Issued 17 January 1991 Resolved
PROVIDE VESSEL WITH 100% IN COVERED LIFEBOATS NO LATER THAN 17 APR 91._x001C_
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Fire Fighting
Issued 17 January 1991 Resolved
PROVIDE OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEM FOR THE ENGINROOM (BOTHLOCAL AND REMOTE STATIONS.)
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Documentation
Issued 17 January 1991 Resolved
SUBMIT FIRE CONTROL PLAN FOR THE APPROVAL AND STATION BILL FOR EXAMINATION.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY GENERATOR OVERSPEED PROTECTION._x001C_ _x001C_
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
DEMONSTRATE PROPER OPERATION OF THE SCR UNIT'S HIGH TEMPERATURE ALARMS.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE MUD PIT LOSS OF AIR FLOW/ALARM.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Fire Fighting
Issued 17 January 1991 Resolved
SUBMIT PLANS FOR APPROVAL OF GALLEY HOOD AND DEEP FAT FRYER FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
PROVE PROPER OPERATION OF ALL AIR PURGED SYSTEMS PER NFPA 496.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
PROVIDE PROPER FIT EXPLOSION PROOF CAP ON THE MUD PIT GAS DETECTORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
PROVIDE TENSION RELIEVING GEAR FOR THE ELECTRICAL CONTROL CABLE TO THE STARBOARD CRANE BOOM.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
REPLACE DAMAGED ARMORED ELECTRICAL CABLE WHERE THERE IS PRESENTLY A 3M SCOTCH CAST WITH APPROVED ARMORED CABLE OR PROVIDE ADEQUATE DOCUMENTATION THAT THE PRESENT CAST IS APPROVED FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Lifesaving
Issued 17 January 1991 Resolved
PROVIDE PROPERLY RATED OUTBOARD MOTOR FOR THE RESCUE BOAT AS PER NAMEPLATE DATA.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
VERIFY PROPER OPERATION OF ALL GENERAL ALARMS AND ENSURE 100% COVERAGE THROUGHOUT THE VESSEL.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Lifesaving
Issued 17 January 1991 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE FIRST AID KIT: A) 19 TRIANGULAR BANDAGES, B) 6-4" COMPRESSES, C) 6-2" COMPRESSES, AND D) 2 TOURNIQUETS.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Documentation
Issued 17 January 1991 Resolved
PROVIDE EVIDENCE OF ALL REQUIRED TESTS AND INSPECTIONS AS PER 46 CFR 109.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Documentation
Issued 17 January 1991 Resolved
PROVIDE EVIDENCE OF A VALID NPDES PERMIT.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Electrical
Issued 17 January 1991 Resolved
REMOVE ALL "SO" TYPE ELECTRICAL CABLE FROM THE SHAKER HAZARDOUS AREAS.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
MAKE THE SHAKER DECK WATERTIGHT. (OVERFLOW OF MUD INCREASES HAZARDOUS AREAS)_x001C_
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Documentation
Issued 17 January 1991 Resolved
PROVIDE ONBOARD AN APPROVED OPERATIONS MANUAL IN ACCORDANCE WITH 46 CFR 109.121.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Fire Fighting
Issued 17 January 1991 Resolved
PROVIDE TWO UL/FM APPROVED EXPLOSION/02 METERS WITH ADEQUATE SAMPLE HOSE.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Lifesaving
Issued 30 October 1986 Resolved
PROVIDE ONE ADDITIONAL 02/COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Electrical
Issued 30 October 1986 Resolved
RENEW OR ENCLOSE IN WEATHERTIGHT J-BOXES THE SPLICED ELECTRICAL WIRING IN WAY OF THE HELIPORT PERIPHERAL LIGHTING AND UNDERDECK LIGHTING.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Electrical
Issued 30 October 1986 Resolved
REPAIR AND TEST THE EMERGENCY GENERATOR; DEMONSTRATE THE CAPABILITY OF THE EMERGENCY BATTERIES TO START IT.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Accommodation/Occupational Safety
Issued 30 October 1986 Resolved
TEST THE RELIEF VALVES ON THE THREE AIR RECEIVERS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Lifesaving
Issued 30 October 1986 Resolved
PROVIDE TWO SMOKE CANISTERS FOR THE RING BUOYS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Deck/Cargo
Issued 30 October 1986 Resolved
REPLACE THE NUMBER 5 P-TANK RELIEF VALVE.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986 Resolved
CONDUCT ANNUAL SERVICING OF ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Construction/Loadline
Issued 26 November 1985 Resolved
MAKE PERMANENT REPAIRS TO THE HOLE IN THE SIDE OF PRELOAD TANK #22
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Documentation
Issued 26 November 1985 Resolved
SUBMIT A REPAIR AND TESTING PROCEDURE TO USCG MARINE SAFETY OFFICE PORT ARTHUR, TEXAS ON ALL THE HOLES CUT IN EACH OF THE PRELOAD TANKS (TEN HOLES TOTAL) AND INCLUDE ALL TESTING RESULTS OBTAINED.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Unknown
Issued 26 November 1985 Resolved
PROVIDE FOR AN INTERNAL EXAMINATION BY A USCG MARINE INSPECTION FOR THE FOUR DRILL WATER TANKS # 6,7,10, AND 11, AT THE NEXT RIG MOVE AND IN NO CASE LATER THAN 26FEB86
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Accommodation/Occupational Safety
Issued 26 November 1985 Resolved
MAKE AVAILABLE FOR INSPECTION THE MUD PIT DUMP VALVE NO LATER THAN THE COMPLETION OF THE PRESENT DRILLING OPERATIONS AND IN NO CASE LATER THAN 26FEB86
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Fire Fighting
Issued 26 November 1985 Resolved
REPLACE OR CONDUCT A HYDROSTATIC TEST OF THE CO2 BOTTLE ON THE B-V PORT. FIRE EXTINGUISHER ON THE HELO DECK.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Accommodation/Occupational Safety
Issued 26 November 1985 Resolved
PROVIDE FOR AN INTERNAL EXAMINATION BY A USCG MARINE INSPECTOR THE 5 BULK TANKS, THE DRILL FLOOR AIR RCVR AND THE RIG AIR RCVR.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Construction/Loadline
Issued 26 November 1985 Resolved
SUBMIT IN WRITING TO MSO PORT ARTHUR, TEXAS THE INTENT AND PURPOSE OF THE PLATFORM QUARTERS ON THE PILOTHOUSE LEVEL WHICH IS BEING USED FOR LIVING QUARTERS.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Construction/Loadline
Issued 26 November 1985 Resolved
COMPLETE THE UNDERWATER EXAMINATION OF THE SPUD CANS AND THE ASSOCIATED NONDESTRUCTIVE TESTING (NDT) OF THE LEG TO SPUD CAN CONNECTIONS IN THE PRESENCE OF A USCG MARINE INSPECTOR AT THE NEXT RIG MOVE AND IN NO CASE LATER THAN 26FEB86
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Construction/Loadline
Issued 26 November 1985 Resolved
RENEW THE FLAME SCREENS ON THE TWO FUEL OIL TANKS PORT SIDE AFT WITH THE PROPER SIZE FLAME SCREENS
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Deck/Cargo
Issued 26 November 1985 Resolved
STENCIL THE LIFTING CAPACITY OF THE FORKLIFT ON THE UNIT.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Deck/Cargo
Issued 26 November 1985 Resolved
PROVIDE ONBOARD THE RIG A SELF-CLOSING SPOUT GAS CAN FOR THE FORKLIFT
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Accommodation/Occupational Safety
Issued 26 November 1985 Resolved
PRESSURE TEST THE ROSS HILL BOP CONTROL UNIT RELIEF VALVE AT THE COMPLETIONOF THE PRESENT DRILLING OPERATION AND IN NO CASE LATER THAN 26FEB86
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Unknown
Issued 11 October 1984 Resolved
PROVIDE THE MODU WITH A COAST GUARD APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Lifesaving
Issued 11 October 1984 Resolved
SERVICE THE HYDROSTATIC RELEASES FOR THE TWENTY-FIVE (25) PERSON LIFERAFTS AT A COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Lifesaving
Issued 11 October 1984 Resolved
PROVIDE THE MODU WITH A STOKES LITTER SUITABLE FOR HELICOPTER USE.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Navigation
Issued 11 October 1984 Resolved
PROVIDE THE MODU WITH ONE ADDITIONAL BLACK BALL DAYSHAPE.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Navigation
Issued 11 October 1984 Resolved
PROVIDE THE MODU WITH SIX (6) ADDITIONAL PARACHUTE FLARES.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Unknown
Issued 11 October 1984 Resolved
REPAIR THE REMOTE SHUTDOWNS FOR THE FUEL OIL TRANSFER PUMP.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Lifesaving
Issued 11 October 1984 Resolved
PROVIDE ELEVEN (11) ADDITIONAL LIGHTS FOR THE EXPIRED ONES ON THE LIFE PRESERVERS OR REMOVE THEM FROM THE MODU.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Electrical
Issued 11 October 1984 Resolved
PROVIDE A PROTECTIVE COVER FOR THE BATTERY BOX IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Deck/Cargo
Issued 11 October 1984 Resolved
PROVIDE THE FORKLIFT WITH A BACKUP SAFETY ALARM.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Unknown
Issued 7 October 1983 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE GULFSTREAM, DN606695.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
MAKE REPAIRS TO THE DISTORTED VENT FOR THE PAINT LOCKER AND INSTALL A FLAMESCREEN.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
CLEAN OFF NAME PLATES FOR FRESH WATER AND SANITARY PRESSURE TANKS. PROVIDE APPROPRIATELY SIZED PRESSURE RELIEF VALVE FOR SANITARY PRESSURE TANK.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
PRESSURE LIFT THE RELIEF VALVES FOR THE TWO 125 PSIG AIR RECEIVERS ON THE DRILL FLOOR AND P TANK AIR SUPPLY.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
PROPERLY WIRE ALL EQUIPMENT IN THE WORK SHOP.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
INSTALL "NOT UNDER COMMAND LIGHTS" (RED OVER RED) IN ACCORDANCE WITH THE 1972 COLREGS (RULES OF THE ROAD).
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
PROVIDE ONBOARD ONE ADDITIONAL OPERABLE OXYGEN AND EXPLOSIVE METER AS RE- QUIRED BY 46 CFR 108.497(C).
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
CONDUCT THE ANNUAL CRANE SURVEY FOR BOTH CRANES IN ACCORDANCE WITH 46 CFR 107.259.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983 Resolved
MAKE REPAIRS TO THE BILGE SUCTION VALVES IN THE FOLLOWING TANKS: #1A, #20 AND #21.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983

Ownership record