Records from 2006 to 2021. Most recent: inspection, 28 June 2021.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 October 2019
Resolved
Life float installations were not illuminated for disembarkation; must provide lighting powered by emergency power to illuminate area.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 14 October 2019
Resolution: Lighting installed at the lifefloat station
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 October 2019
Resolved
Surge protector in berthing not serviceable. Remove faulty surge protectors to eliminate electrical hazard.
Action required: 10 - Deficiency Rectified
Due 11 October 2019
Resolved 11 October 2019
Resolution: Discarded faulty equipment.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 October 2019
Resolved
Battery charger for navigation bridge equipment inoperable upon arrival.
Action required: 10 - Deficiency Rectified
Due 11 October 2019
Resolved 11 October 2019
Resolution: Repaired to function correctly and provide trickle charge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
Repair broken support brackets in the rudder room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
Shut off valve for ballast pump leaks, replace or repair shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
Replace 02 guards for rotating steering gear parts located in the engine room ladder well.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 October 2018
Resolved
Replace wasted gasket on engine room watertight door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 October 2018
Resolved
Replace missing bolts on cofferdam and starboard fuel tank access.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2018
Resolved 25 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
Properly secure and replace partially wasted armored electrical cable for the constant volt system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2018
Resolved
Fuel hard piping is wasted and leaking small amounts of fuel into the bilge. Replace wasted fuel cross connect piping for the MDE and properly dispose of oil/fuel bilge water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2018
Resolved 25 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2018
Resolved
Replace cracked portable fire extinguisher hose in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 24 October 2018
Resolved
Provide means of properly securing rescue platform to ship.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
Replace starboard fuel shut-off handle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 24 October 2018
Resolved
Rudder angle indicator on bridge was inoperable. Repair rudder angle indicator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 October 2018
Resolved
Life float not serviceable. Replace entire life float.
Action required: 10 - Deficiency Rectified
Due 25 November 2018
Resolved 24 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 October 2018
Resolved
Lanyard attaching waterlight to life float was not of sufficient length. Replace line with serviceable line of proper length (18ft).
Action required: 10 - Deficiency Rectified
Due 25 November 2018
Resolved 24 October 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2018
Resolved
Surge protector in berthing not serviceable. Remove faulty surge protectors to eliminate electrical hazard.
Action required: 10 - Deficiency Rectified
Due 25 November 2018
Resolved 24 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 October 2018
Resolved
Vessel navigation sidelights do not have matte black screens. Install matte black screens on sidelights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 October 2018
Accommodation/Occupational Safety › Ventilation › General
Issued 19 December 2017
Resolved
Goose neck vents (2) for the STBD side ballast tanks were cracked and had holes in it.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Both vents were properly welded.
Electrical › Lighting (service) › Outlet Box
Issued 19 December 2017
Resolved
Recepticle above bridge needed to be properly secured.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Item was rewelded and properly secured.
Lifesaving › Lifefloat › Float-free Link
Issued 19 December 2017
Resolved
Needed to rearrange the life floats and ensure the proper weak link.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2017
Resolution: Life floats were rearranged with proper weak link.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 19 December 2017
Resolved
Provide proper watertight seal for wiring running through exterior bulkhead of bridge.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Metal wiring bracket was added to the bulkhead allowing wiring to go through and keeping it watertight.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 19 December 2017
Resolved
Seven life jackets were missing PMLs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2017
Resolution: PMLs were added to those life jackets.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 December 2017
Resolved
Wiring thoughout the vessel (eng room, bridge and accommidations) had wiring with no metal tie backs.
Condition: Improper Installation
Due 26 December 2017
Resolved 20 December 2017
Resolution: Metal tie backs were placed on wiring in areas around doorways passage ways and in the engine room.
Construction/Loadline › Penetrations › Gasket
Issued 19 December 2017
Resolved
Water tight doors (eng room and aux room) had worn out/ wrong type of gaskets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2018
Resolution: New gaskets were added.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 19 December 2017
Resolved
Ground fault not working properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2017
Resolution: Electrician came and repaired the ground fault.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 December 2017
Resolved
Emergency escape hatch missing lable.
Condition: Improper Installation
Due 26 December 2017
Resolved 20 December 2017
Resolution: Escape hatch labeled.
Construction/Loadline › Penetrations › Gasket
Issued 19 December 2017
Resolved
emergency escape hatch leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2017
Resolution: Replaced with new gasket.
Engineering › Fuel Oil Service System › Hose
Issued 19 December 2017
Resolved
Wrong type of hose for the oil gauge hose on port side MDE.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Replaced with proper hose.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 19 December 2017
Resolved
Clutch oil alarm light inop.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Repaired alarm light.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 19 December 2017
Resolved
Alarm for panel horn inop.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Horn repaired.
Construction/Loadline › Structures › Deck Plating
Issued 19 December 2017
Resolved
Hole in eng room deck (approx 12 in.)
Condition: Improper Installation
Due 26 December 2017
Resolved 20 December 2017
Resolution: Added new plate to deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 December 2017
Resolved
Light in aux room needs proper cover.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: New light fixture was added.
Communications › Audible Communications › Horn/Whistle
Issued 19 December 2017
Resolved
Horn inop.
Condition: Improper/Lack of Maintenance
Due 26 December 2017
Resolved 20 December 2017
Resolution: Horn was replaced.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 December 2017
Resolved
Provide proper documentation of safety drills.
Condition: Invalid
Due 6 April 2018
Resolved 24 April 2018
Resolution: Drills have been properly logged.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 December 2017
Resolved
Not properly documenting safety equipment checks.
Condition: Invalid
Due 6 April 2018
Resolved 24 April 2018
Resolution: Safety checks have been properly logged.
Electrical › Lighting (service) › Ground Detection
Issued 19 December 2017
Resolved
Provide proper wiring for nav lights.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2017
Resolution: 3rd Party corrected issue.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 14 October 2016
Resolved
Exhaust piping for both MDE's had leaks which were just repaired. All Exhaust lagging still removed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 18 October 2016
Resolution: Verified lagging installed.
Engineering › Pressure Vessel › Relief Valve
Issued 14 October 2016
Resolved
Both Pressure relief valves painted. Vessel representative stated that he had some enroute.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Both PRV'S replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 October 2016
Resolved
F/O shut off valve STBD side does not completely close when pulled. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: ROV adjusted and tested Sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 October 2016
Resolved
STBD MDE inadequate guard on harmonic balancer.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Guard modified removing hazard.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 14 October 2016
Resolved
Heat detectors did not activate any alarms during tests.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: A wire was disconnected was identified and both heat probes were replaced. System tested sat.
Fire Fighting › Fire Main › Condition
Issued 14 October 2016
Resolved
Found a temp patch on piping for ballast/ fire pump temp patch removed active leak identified. C/R to good metal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Wasted section of pipe replaced and operational test of system sat.
Lifesaving › Lifebuoys › Serviceable
Issued 14 October 2016
Resolved
AC Duct tape identified as retro on most of the lifesaving appliances.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Retro of proper type affixed to the lifesaving equipmment.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 October 2016
Resolved
2 Waterlights found inoperable. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Lights replaced and tested sat.
Fire Fighting › Ventilation Systems › Fans
Issued 14 October 2016
Resolved
Fan guard and motor Port side E/R obstructed w/ oil and dirt.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Fan cleaned.
Lifesaving › Lifefloat › Float-free Link
Issued 14 October 2016
Resolved
Incorrect weak link size and weak link configuration.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Weak link installed correctly.
Construction/Loadline › Structures › Scuttle
Issued 14 October 2016
Resolved
Gasket on escape scuttle to engine room missing. Replace and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2016
Resolved 17 October 2016
Resolution: Gasket replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 October 2016
Resolved
Crew failed manoverboard drill. Conduct a satisfactory man overboard drill in the presence of attending MI.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2016
Resolved 17 October 2016
Resolution: Conduted a sat MOB and fire drill.
Documentation › Logs/Records › Logbook (official)
Issued 14 October 2016
Resolved
Drills not being conducted or logged.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2016
Resolved 17 October 2016
Resolution: Vessel master and representative informed of requirements. Vessel was held up for 3 days from returning to service while they conducted and logged drills.
Construction/Loadline › Penetrations › Weld
Issued 16 January 2016
Resolved
Several small stress cracks found in stbd deck insert.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 5 February 2016
Resolution: Using dye pent found no stress cracks or pin holes in deck insert. Cleared 01 deficiencies.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 14 January 2016
Resolved
spun main bearing, resulting in no lubrication, overheating engine to to the point of catastrophic failure
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2016
Resolution: Vessel replaced stbd main diesel engine in kind. Test ran engine for leak and vibration test. All sat.