Records from 1980 to 2007. Most recent: inspection, 4 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
4 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3109323
22 March 2007
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2892841
20 March 2006
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2605626
28 October 2005
Examination of Repairs · Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2518878
29 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2444299
1 March 2005
Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2301617
17 January 2003
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1731907
26 December 2002
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1722967
18 October 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405067
1 October 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 515685
28 September 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 470908
9 September 1999
Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386600
30 January 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 75471
9 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768151
11 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 205427
7 August 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466544
15 October 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447752
9 August 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374715
9 August 1995
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390105
9 February 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1150918
12 August 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213421
12 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466361
7 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1323992
7 September 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354456
1 October 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243951
10 August 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436701
31 March 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953045
12 September 1991
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1251333
20 August 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241461
29 August 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1031346
15 August 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041417
9 July 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025589
22 December 1986
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027453
20 November 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1017584
24 October 1986
Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016696
23 August 1986
COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1009987
30 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000705
9 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999350
21 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986604
17 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978522
20 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976518
20 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283821
14 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279044
29 December 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275308
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 March 2007
Resolved
One water light was not properly spliced around the life float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 March 2007
Resolved
The EPIRB was not being tested monthly.
Action required: 705 - Other - as specified
Resolved 22 March 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2006
Resolved
The nav lights are required to be vertical filaments. All nav light bulbs need to be changed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 March 2006
Resolved
Electric Waterlight must be attached to the life float.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Lifesaving › Lifefloat › Paddle
Issued 20 March 2006
Resolved
Label paddles with name vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Lifesaving › Lifefloat › Painter
Issued 20 March 2006
Resolved
Attach both lifefloats to each other because there is only one weak link. The UV resistant line must be long enough so that the top float can reach the surface of the water without disturbing the bottom.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 20 March 2006
Resolved
Install a proper SSB antenna mount.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Engineering › Steering Gear System › Power Unit
Issued 20 March 2006
Resolved
Label steering pump controller.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 20 March 2006
Resolved
Install a slide between the two main breakers for each generator so that no more than one breaker can be closed at a time.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Communications › Radio Communications › EPIRB
Issued 20 March 2006
Resolved
Install EPIRB bracket and hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2006
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 1 March 2005
Resolved
Provide operational rudder angle indicator.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Construction/Loadline › Hull › Hull Plating
Issued 1 March 2005
Resolved
02 level at aft steering station deck plate holed, complete repairs.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 March 2005
Resolved
Provide mud basket strainer at bilge pump inlet.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 1 March 2005
Resolved
Provide Ballast Water Management plan on board vessel.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 1 March 2005
Resolved
Provide fire Safety plan for approval.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 March 2005
Resolved
Conduct drills in the presence of Marine Inspector.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 March 2005
Resolved
Provide sewage tank 3/4 full alarm.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 1 March 2005
Resolved
Provide annual hydrostatic test for F/O transfer hose.
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 28 October 2005
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 26 December 2002
Resolved
REPAIR FREEZER DOOR LATCH. LEGACY COMPONENT DESC: DOOR LATCH
Due 26 January 2003
Resolved 26 December 2002
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 December 2002
Resolved
pPAIND DRAFT MARKS ON STBD. AND PORT SIDES OF VESSEL
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2003
Resolved 26 December 2002
Electrical › Electric Supply System (service) › Battery Charger
Issued 26 December 2002
Resolved
RENEW AMP METER ON BATTERY CHARGER IN ENGINEROOM.
Due 26 January 2003
Resolved 26 December 2002
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 December 2002
Resolved
RENEW RETRO TAPE ON 9 LIFE JACKETS.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2003
Resolved 26 December 2002
Operations/Management › Other Criminal/Civil Violations
Issued 26 December 2002
Resolved
VESSEL MISSED YEARLY REINSPECTION REQUIRED BY 46 CFR 91.27-1. LEGACY COMPONENT DESC: VESSEL MISSED YEARLY REINSPECTION
Condition: Unknown
Due 26 December 2002
Resolved 26 December 2002
Lifesaving
Issued 18 October 2000
Resolved
DEMONSTRATE PROPER OPERATION OF SOUND POWERED PHONES IN ENGINE ROOM AND WHEELHOUSE UNDER NORMAL AND EMERGENCY POWER IAW 46 CFR 113.30-25.
Condition: Unknown
Due 18 November 2000
Resolved 28 November 2000
Lifesaving
Issued 9 September 1999
Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR RESCUE BOATREQUIREMENT FOR OFFSHORE SUPPLY VESSELS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Engineering
Issued 7 September 1993
Resolved
PROVIDE CERTIFICATE OF HYDRO TEST FOR ONE (1) 50 FT LENGTH OF 2" FUEL OIL_x001C_ TRANSFER HOSE.
Condition: Unknown
Due 14 September 1993
Resolved 9 September 1993
Fire Fighting
Issued 7 September 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 September 1993
Resolved 9 September 1993
Engineering
Issued 12 September 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF STBD MAIN ENGINE OVERSPEED.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Navigation
Issued 12 September 1991
Resolved
ADJUST STEERING CONTROLS SO THAT RAMS STOP PRIOR TO ENGAGING MECHANICAL STOPS.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Construction/Loadline
Issued 24 October 1986
Resolved
PRESENT VESSEL FOR INSPECTION AND AIR TEST OF REPAIRS TO DECK (PORT STERN CENTER), PERSONNEL PLATFORM, BULWARK AND CARGO RAIL.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Engineering
Issued 20 November 1984
Resolved
INSTALL FUEL OIL FILTER SPRAY SHIELDS ON ALL RACOR TYPE FUEL OIL FILTERS.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984
Documentation
Issued 20 November 1984
Resolved
BRING OIL TRANSFER PROCEDURES INTO COMPLIANCE WITH THE REGULATIONS.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984
Unknown
Issued 14 December 1983
Resolved
REMOVE OR REPAIR THE RUDDER ANGLE INDICATOR WHICH IS DEFECTIVE ON THE BRIDGE AND AFTER STEERING SECTION.
Condition: Unknown
Due 14 December 1983
Resolved 14 December 1983
Unknown
Issued 14 December 1983
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE ARGOSY ADVENTURER, DN606730.
Condition: Unknown
Due 14 December 1983
Resolved 14 December 1983