Records from 1981 to 2011. Most recent: inspection, 25 February 2011.
Inspection history · 44
25 February 2011
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3952645
13 January 2011
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3926186
5 January 2009
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3389190
11 August 2008
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3295231
23 April 2008
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3196046
14 February 2008
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147640
18 September 2007
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3060619
12 April 2006
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2610583
5 July 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2414997
15 June 2005
Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2391701
8 March 2005
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2305724
27 May 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2109111
17 March 2004
Re-Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2026128
13 January 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1729790
2 April 2002
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1492964
27 September 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393782
6 March 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386739
17 June 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433524
23 February 1999
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1365085
2 March 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436054
16 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111823
26 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460073
16 February 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359079
14 February 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436948
9 February 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401817
24 March 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417491
7 February 1992
COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955139
22 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927045
5 April 1991
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924274
13 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 985638
16 February 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916132
23 February 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195026
16 September 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043301
9 March 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338893
10 February 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018961
23 March 1987
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1022572
2 September 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1309823
27 March 1986
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 997925
4 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1290670
13 September 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 975087
10 April 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973616
13 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966393
3 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968592
10 June 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968165
Engineering › Steering Gear System › Piping
Issued 13 January 2011
Resolved
Top of Hydraulic tank was leaking oil. Found loose pump suction piping. Tank top has large amounts of RTV around edge to contain oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 February 2011
Resolution: Pumps were repaired to correct leakage.
Engineering › Compressed Air System (control) › Piping
Issued 13 January 2011
Resolved
Air regulator leaking from orifice in regulator body.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2011
Resolution: Replaced Air regulator
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 January 2011
Resolved
lifefloats and oars require vessel name.
Action required: 705 - Other - as specified
Resolved 25 February 2011
Resolution: vessel names were placed on items.
Construction/Loadline › Hull › Side Shell
Issued 18 September 2007
Resolved
Properly repair punctures on port side shell below deck house. Cut out and insert new steel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 11 August 2008
Operations/Management › Drills/Instruction › Abandon Ship
Issued 15 June 2005
Resolved
Provide logs.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 23 June 2005
Resolution: Provided Logs.
Operations/Management › Drills/Instruction › Fire
Issued 15 June 2005
Resolved
Provide logs.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 23 June 2005
Resolution: Provided Logs.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 June 2005
Resolved
Provide Logs
Due 15 July 2005
Resolved 23 June 2005
Resolution: Provided Logs
Communications › Alarms/Indicators › General Alarm
Issued 15 June 2005
Resolved
Provide back-up power to General Alarm system.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 23 June 2005
Lifesaving › Buoyant Apparatus
Issued 3 January 2003
Resolved
Renew weak link of proper size and type for lifefloats. LEGACY COMPONENT DESC: Weak Link
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2003
Resolved 3 January 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 3 January 2003
Resolved
Renew flame screen on lube oil tank vent.
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 3 January 2003
Accommodation/Occupational Safety › Potable Water System
Issued 3 January 2003
Resolved
Provide bug screen for potable water tank vent. LEGACY COMPONENT DESC: Ventilation
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 3 January 2003
Documentation › Markings/Placards › Garbage Placard
Issued 3 January 2003
Resolved
Provide MARPOL placard.
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 3 January 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 3 January 2003
Resolved
Replace Machinery Space fire extinguisher hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2003
Resolved 3 January 2003
Engineering › Fuel Oil Service System › Filter
Issued 3 January 2003
Resolved
Place metal plugs in fuel filters for port generator and fire monitor engine.
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 3 January 2003
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 January 2003
Resolved
Provide double clamps for all flexible hoses.
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 3 January 2003
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 3 January 2003
Resolved
Provide emergency broadcast placard.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2003
Resolved 3 January 2003
Stability › Watertight Integrity
Issued 3 January 2003
Resolved
Properly adjust Engine Room escape hatch. LEGACY COMPONENT DESC: Watertight Hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2003
Resolved 3 January 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 January 2003
Resolved
Stencil emergency escape hatch on Messdeck in plain view.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2003
Resolved 3 January 2003
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 January 2003
Resolved
Provide emergency lighting in Gally and overnight accommadation space and reposition emergency light in overnight accommadation space to illuminate ladder.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2003
Resolved 3 January 2003
Engineering › Bilge Water Management System › Piping
Issued 2 April 2002
Resolved
PRIOR TO VESSEL MOVEMENT REPAIR BILGE SUCTION PIPING TO REMOVE RED HAND PATCH.
Condition: Improper Installation
Due 2 April 2002
Resolved 2 April 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 April 2002
Resolved
INSTALL METAL SHIELD ON STBD FWD ENGINE ROOM 220V BREAKER PANEL.
Condition: Improper Installation
Due 2 April 2002
Resolved 2 April 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 April 2002
Resolved
INSTALL 01 ADDITIONAL EMERGENCY EGRESS LIGHT TO ILLUMINATE THE ENGINE ROOM WATERTIGHT DOOR AND LADDER.
Condition: Improper Installation
Due 2 April 2002
Resolved 2 April 2002
Engineering › Fuel Oil Service System › Filter
Issued 2 April 2002
Resolved
INSTALL METALLIC PLUGS IN THE ENGINER OOM FUEL OIL FILTER FLAME BOWLS.
Condition: Improper Installation
Due 2 April 2002
Resolved 2 April 2002
Communications › Internal Communications System
Issued 2 April 2002
Resolved
REPAIR CREWS LOUNGE PUBLIC ADRESS SYSTEM LEGACY COMPONENT DESC: PUBLIC ADDRESS SYSTEM
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2002
Resolved 2 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 2 April 2002
Resolved
PROPERLY SECURE FREEZER. LEGACY COMPONENT DESC: CREWS LOUNGE
Condition: Improper Installation
Due 2 April 2002
Resolved 2 April 2002
Engineering
Issued 6 March 2000
Resolved
PROVIDE ADEQUATE ENGINE STOPS IN PILOT HOUSE IAW 46CFR184.620 TO SATISFACTION OF ATTENDING MARINE INSPECTOR, PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 6 April 2000
Resolved 21 March 2000
Engineering
Issued 5 April 1991
Resolved
INSTALL PILOT HOUSE STARTS AND STOPS FOR MAIN ENGINES. [46CFR175.10-29]_x001C_ AS AN ALTERNATIVE A COMMUNICATION SYSTEM INSTALLED UNDER 46CFR 184.35-1_x001C_ MAY BE CONSIDERED AND APPROVED BY THE OCMI.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Documentation
Issued 5 April 1991
Resolved
PROVIDE CURRENT COPIES OF CHARTS, 46 CFR SUBCHAPTER T, AND NAVIGATION_x001C_ RULES.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Fire Fighting
Issued 16 February 1990
Resolved
REPAIR FIRE MONITOR PIPELINE FROM PUMP THRU ENGINE ROOM, MACHINERY SPACE UPTO STACK RISER. MONITOR IS NOT TO BE USED UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990