← All vessels
DREAM SPEED
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named DREAM SPEED
DREAM SPEED is a 1979 passenger vessel (inspected). The Coast Guard has recorded 96 inspections since 1985, most recently in June 2026, along with 136 deficiencies — 1 with no resolution recorded — and 2 casualty investigations in 2011.
Records from 1985 to 2026. Most recent: inspection, 2 June 2026.
- Built
- 1979
- Last inspected
- 2 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 136 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2011
Identity
607357
WDI2942
50292
Flag
UNITED STATES
367683340, 368167060
Maury page id
psix-50292
Inspections, by type
…with no type recorded12
…past their stated due date1
Years with a record
36 calendar years (1985–2026)
The 96 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)71.0 ft × 18.0 ft × 8.4 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERGERON BOATS INC · LAFITTE, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCRUZ BAY, VI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
57 - Simplified, Net Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI2942MMSI 367683340 · active · compulsorily equipped · granted 12 June 2025, expires 11 July 2035
WDL8168MMSI 368167060 · active · compulsorily equipped · granted 20 October 2020, expires 20 October 2030 · licensed under a name not among this hull’s recorded names (not shown)
EX236MMSI 367683340 · expired · exemption · granted 19 March 2018, cancelled 19 March 2022
WDD6499MMSI 367173660 · cancelled · compulsorily equipped · granted 10 March 2017, cancelled 8 October 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDC2441MMSI 366993240 · expired · compulsorily equipped · granted 24 November 2004, cancelled 24 January 2015
WXP2806MMSI not assigned · expired · compulsorily equipped · granted 17 June 1994, cancelled 22 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 96
2 June 2026
MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8387179
4 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8321188
18 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190063
11 June 2025
COI Inspection · Administrative Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8157807
30 August 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7992084
31 July 2024
COI Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7977915
10 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7932099
18 August 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7778664
7 June 2023
ISPS Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7690379
25 August 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7543992
9 June 2022
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7464308
31 August 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7301478
16 June 2021
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7218562
8 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7152377
10 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7055480
30 January 2020
COI Inspection · MTSA/ISPS Verification · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6892591
19 August 2019
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6892600
31 January 2019
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6614931
28 August 2018
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6506974
19 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6449518
1 February 2018
MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6345324
29 August 2017
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6253591
9 December 2016
MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6055126
26 September 2016
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6009979
12 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5998867
20 November 2015
Construction Oversight · COI Inspection · Inclining Experiment
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5767514
24 September 2010
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3858386
25 September 2008
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3332459
18 October 2007
Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3082735
19 September 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3061387
13 July 2006
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2711873
27 June 2006
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2693454
17 October 2005
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2516500
3 August 2005
Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2450602
29 November 2004
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2249820
28 April 2004
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2055456
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996915
25 September 2003
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1912534
18 September 2003
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1910333
15 September 2003
Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1910254
1 July 2003
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1856870
13 February 2002
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1486185
22 October 2001
Inclining Experiment
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1487809
3 July 2001
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1486195
11 January 2000
MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1365642
30 December 1999
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372868
15 June 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444234
27 April 1998
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364732
7 October 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1147614
22 June 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664433
19 June 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363709
12 June 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1081292
7 June 1996
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383269
29 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1084386
15 April 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 22910
31 October 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664429
30 August 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 196648
3 July 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1191524
9 June 1995
Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1453136
25 May 1995
Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358770
3 May 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1180215
25 April 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 863923
14 March 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1175952
27 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 856171
1 December 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179503
18 November 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664424
17 November 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179148
9 November 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1173467
5 November 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 35602
24 October 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1174383
22 September 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 870690
1 August 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1172043
28 July 1994
Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444872
9 June 1994
COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1362999
2 August 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 844792
21 July 1993
Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410836
30 June 1993
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358109
20 August 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 943575
5 August 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1260812
10 July 1992
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 948951
30 June 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1259222
30 June 1992
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1266276
27 June 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 943278
12 June 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 892418
27 July 1990
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1241579
29 June 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 926462
19 June 1990
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 921688
30 January 1990
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 918760
25 July 1989
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1031820
21 September 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 893948
5 August 1988
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1032863
6 August 1987
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1339214
14 July 1986
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1298798
20 December 1985
Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1307423
12 July 1985
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 985146
25 January 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 979116
Deficiency record · 136
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 4 March 2026
No resolution recorded
Key personnel must complete training in 33CFR101.650(d)(2) by January 12, 2026.
Company does not have a CYSO and all key personnel have not yet completed the training as of this inspection.
33 CFR 101.650(d)(4)
705: 60 days
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 January 2019
Resolved
Provide fixed firefighting servicing report.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 September 2016
Resolved
Prior to carrying passengers contact OCMI of MSD ST. Thomas to conduct new to zone inspection including all safety drills to the satisfaction of the attending Marine Inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 10 October 2007
Resolved
Provide pit/gauging report for bottom plating on the starboard side of forward engine room bulkhead, submit written plan for repair
Construction/Loadline › Penetrations › Gasket
Issued 10 October 2007
Resolved
Provide plans for transducer installation
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 October 2007
Resolved
Submit plans for engine exhaust modifications prior to installation
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 October 2007
Resolved
Replace rotten plywood at battery boxes
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 October 2007
Resolved
Reinforce indicated passenger seating to support passenger weight
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 October 2005
Resolved
Modifications to bow to be completed to satisfaction of attending USCG marine inspector prior to carrying passengers.
Stability › Watertight Integrity
Issued 15 September 2003
Resolved
Make permanent repairs to hull plating and web frame #4, portside, in way of Void #1, that was caused by collision with ATON during the week end of 13SEP03, no later than 31JAN04.
Stability › Watertight Integrity
Issued 15 September 2003
Resolved
Make permanent repairs to fractured weld at base of company flag pole at main deck bow area. Repair welds shall be FULL PENETRATION and to the satisfaction of an attending CG Marine Inspector.
Stability › Watertight Integrity
Issued 15 September 2003
Resolved
Make permanent modifications to main deck company flag pole base plate on bow. Main deck plate shall be properly inserted and new doubler plate installed for flag pole foundation at main deck to the satisfaction of an attending CG Marine Inspector.
Construction/Loadline › Hull
Issued 1 July 2003
Resolved
Audio gauge hull plating in way of pin hole on port bow side shell plating and provide written report of results prior to any repairs. LEGACY COMPONENT DESC: Side Shell
Fire Fighting › Fire Pumps
Issued 1 July 2003
Resolved
Properly align and prove proper operation of port and starboard engine-driven fire pumps. LEGACY COMPONENT DESC: Arrangement
Engineering › Sea-water System (primary cooling)
Issued 1 July 2003
Resolved
Make permanent repairs to starboard v-drive overboard discharge piping found leaking in engine room. LEGACY COMPONENT DESC: Piping
Engineering › Freshwater System (jacketwater cooling)
Issued 1 July 2003
Resolved
Double up steel clamps on all engine room flexible water hoses. LEGACY COMPONENT DESC: Hose
Operations/Management › Drug and Alcohol Testing
Issued 1 July 2003
Resolved
Prove participation of all crewmembers in a random drug-testing program. LEGACY COMPONENT DESC: Proof of Enrollment
Fire Fighting › Fire Hydrants
Issued 1 July 2003
Resolved
Provide spanner wrench for fire station.
Documentation › Certificates/Documents
Issued 1 July 2003
Resolved
Post revised permanent stability letter under glass or other suitable transparent material in the pilothouse of the vessel so that all pages are visible. LEGACY COMPONENT DESC: Stability Letter
Electrical › Lighting (emergency)
Issued 1 July 2003
Resolved
Prove proper operation of and identify all 32V Emergency light fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Lifesaving › Lifejacket/PFD (General)
Issued 1 July 2003
Resolved
Identify lower passenger compartment starboard overhead lifejacket storage areas with applicable PFD size(s). LEGACY COMPONENT DESC: Storage
Electrical › Lighting (service)
Issued 1 July 2003
Resolved
Remove all unused 110V lighting fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Documentation › Certificates/Documents › Stability Letter
Issued 3 July 2001
Resolved
POST STABILITY LETTER ONBOARD VESSEL
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 July 2001
Resolved
PROVIDE TRAINING LOG
Documentation › Markings/Placards
Issued 3 July 2001
Resolved
POST EMERGENCY INSTRUCTION LIST IN PILOTHOUSE LEGACY COMPONENT DESC: EMERGENCY INSTRUCTION LIST
Lifesaving › Hand Flares
Issued 3 July 2001
Resolved
MARK VISUAL DISTRESS FLARES CONTAINER LEGACY COMPONENT DESC: Storage Box
Engineering › Bilge Water Management System
Issued 3 July 2001
Resolved
REMOVE OILY BILGE RESIDUES FROM VOID#1
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 July 2001
Resolved
LABEL CHILDRENS LIFEJACKET STORAGE WITH LOCATION AND QUANTITY. LEGACY COMPONENT DESC: Storage
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 July 2001
Resolved
MARK ALL PFD'S WITH VESSEL NAME
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2001
Resolved
REMOVE BARE WIRES FROM FUEL TANK SPACE
Electrical › Lighting (service) › Lighting Fixture
Issued 3 July 2001
Resolved
COVER EXPOSED LIGHT BULB IN LADIES LAVATORY
Construction/Loadline › Structures › Scuttle
Issued 3 July 2001
Resolved
MAKE ENGINE ROOM HATCH WATERTIGHT, REPAIR DOGGING MECHANISM AND RENEW GASKET.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 July 2001
Resolved
INSTALL MISSING LAGGING ON BOTH MAIN ENGINES.
Engineering › Bilge Water Management System › Strainer
Issued 3 July 2001
Resolved
INSTALL PROPER ENGINE ROOM BILGE SUCTION STRAINER IAW 46 CFR 182.510 (b).
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 July 2001
Resolved
INSTALL CORRECT APPROVED FIRE EXTINGUISHER BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 July 2001
Resolved
ATTACH AFT LIFEJACKET LOCKERS TO DECK
Communications › Internal Communications System
Issued 3 July 2001
Resolved
INSTALL MICHROPHONE FOR PUBLIC ADDRESS SYSTEM.
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 July 2001
Resolved
RENEW MAGNETIC COMPASS AND CALIBRATE
Documentation › Certificates/Documents › Stability Letter
Issued 3 July 2001
Resolved
Passengers are restricted from the upper deck until new stability test is conducted.
Navigation
Issued 11 January 2000
Resolved
Post the Emergency Broadcast Placard near the operating station.
Engineering
Issued 11 January 2000
Resolved
Install machinery guards on both port and starboard engines.
Navigation
Issued 11 January 2000
Resolved
Prove proper operation of Public Address system.
Lifesaving
Issued 11 January 2000
Resolved
Renew retro-reflective tape on lifejackets as necessary.
Lifesaving
Issued 11 January 2000
Resolved
Renew contents of first aid kit IAW 46 CFR 160.041.
Documentation
Issued 11 January 2000
Resolved
Provide valid FCC Ship Safety Certificate.
Documentation
Issued 19 June 1996
Resolved
PROVIDE CHART OF LOCAL AREA.
Accommodation/Occupational Safety
Issued 19 June 1996
Resolved
CLOSE VESSEL'S MARINE SANITATION DEVICE; VSL NOT TO DISCHARGE SEWAGE WITHIN3 MILES OF COASTLINE.
Lifesaving
Issued 19 June 1996
Resolved
MAKE BOTTOM STEP TO SECOND DECK LADDER SECURE.
Construction/Loadline
Issued 19 June 1996
Resolved
MAKE DECK HATCH TO LAZARETTE SECURE.
Electrical
Issued 19 June 1996
Resolved
MAKE VESSEL'S GENERATOR OPERATIONAL AND PROVE TO THE COAST GUARD.
Lifesaving
Issued 19 June 1996
Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD IN A FLOAT FREE ARRANGEMENT AFCC ACCEPTED CATEGORY 1, 406MHz EPIRB.
Unknown
Issued 19 June 1996
Resolved
POST SIGN IN THE VICINITY OF THE SECOND DECK INDICATING NUMBER OF PASSENGERS ALLOWED ON THE SECOND DECK.
Documentation
Issued 19 June 1996
Resolved
MAKE AVAILABLE TO THE COAST GUARD 50 PERCENT OF THE CREW'S DRUG TESTING RECORDS COVERING THE LAST 12 MONTHS.
Documentation
Issued 19 June 1996
Resolved
RENEW VESSEL'S EXPIRED FCC SAFETY CERTIFICATE.
Lifesaving
Issued 19 June 1996
Resolved
REMOVE BATTERY ACID AND HYDRAULIC OIL UNDER BRIDGE PANEL.
Fire Fighting
Issued 19 June 1996
Resolved
INSTALL 1 FIRE AXE ADJACENT TO THE PILOT HOUSE.
Documentation
Issued 19 June 1996
Resolved
RENEW VESSEL'S EXPIRED CERTIFICATE OF DOCUMENTATION.
Construction/Loadline
Issued 19 June 1996
Resolved
MAKE PORT SIDE AFT DECK PLATE SECURE.
Construction/Loadline
Issued 7 June 1996
Resolved
PROVIDE COAST GUARD A PROPOSAL FOR REMOVAL OF WASTED BOLTS AND REPAIR OF CORRODED AREAS SURROUNDING BOLTS IN THE WAY OF THE PORT AND STARBOARD RUB RAILS.
Engineering
Issued 7 June 1996
Resolved
REPAIR OR REPLACE PORT PROPELLER.
Deck/Cargo
Issued 7 June 1996
Resolved
REPLACE RUSTED AND WASTED SHACKLE ON BOW ANCHOR.
Construction/Loadline
Issued 7 June 1996
Resolved
PROVIDE COAST GUARD A PROPOSAL TO REPAIR THE PORT AND STARBOARD STERN CORNER RUB RAILS.
Construction/Loadline
Issued 7 June 1996
Resolved
PROVIDE COAST GUARD A PROPOSAL TO REPAIR FRAMES 1 THRU 6 AND AFT BULKHEAD IN COMPARTMENT #2.
Engineering
Issued 7 June 1996
Resolved
REPLACE STARBOARD PROPELLER CUTLASS BEARING.
Lifesaving
Issued 29 May 1996
Resolved
PROPERLY INSTALL B/As LOCATED ON THE VESSEL'S BOW IN ACCORDANCE WITH CFR 180.20.
Lifesaving
Issued 9 June 1995
Resolved
INSTALL SLATS BETWEEN BUOYANT APPARATUSES LOCATED ON AFT UPPER DECK.
Navigation
Issued 9 June 1995
Resolved
OBTAIN CHARTS FOR AREAS OF OPERATION.
Lifesaving
Issued 9 June 1995
Resolved
REPLACE MISSING HYDRO-STATIC RELEASE ON THE AFT PORTSIDE LIFE RAFT.
Engineering
Issued 9 June 1995
Resolved
INSTALL PROPER SIZE FLAME SCREENS IN FUEL TANK VENTS.
Accommodation/Occupational Safety
Issued 25 May 1995
Resolved
PROVIDE PROPER VENTING FOR SEWAGE TANK TO OPEN ATMOSPHERE._x001C_
Lifesaving
Issued 25 May 1995
Resolved
REMOVE EXCESS OIL IN BILGES._x001C_
Accommodation/Occupational Safety
Issued 25 May 1995
Resolved
CAP OFF UNUSED 2-1/2" FITTING TO SEWAGE TANK._x001C_
Construction/Loadline
Issued 25 May 1995
Resolved
REPLACE DISCHARGE HOSE FROM ENGINEROOM ELECTRIC BILGE PUMP WITH AN APPROVEDTYPE._x001C_
Engineering
Issued 25 May 1995
Resolved
PROPERLY MOUNT STARBOARD TRANSMISSION OIL COOLER._x001C_
Electrical
Issued 25 May 1995
Resolved
REPLACE CAP FOR GENERATOR COOLING RESERVOIR._x001C_
Navigation
Issued 25 May 1995
Resolved
MARK SEWAGE OVERBOARD VALVE WITH PLACARD: "SEWAGE OVERBOARD VALVE - DO NOT OPEN WITHIN 3 MILES OF LAND IN U.S. WATERS"._x001C_
Lifesaving
Issued 25 April 1995
Resolved
PROPERLY STENCIL VESSEL'S NAME ON FORWARD RING BUOY AND REATTACH WATER LIGHT.
Engineering
Issued 25 April 1995
Resolved
PROPERLY REPAIR, STENCIL AND REPLACE THE FLAME SCREENS ON ALL FUEL TANK VENTS.
Fire Fighting
Issued 25 April 1995
Resolved
HAVE ALL EXPIRED/DISCHARGED FIRE EXTINGUISHERS PROPERLY SERVICED PRIOR TO TAKING PASSENGERS FOR HIRE.
Construction/Loadline
Issued 25 April 1995
Resolved
PROPERLY REMOVE AND DISPOSE OF EXCESS OIL FROM THE BILGES LOCATED IN THE FUEL TANK SPACE.
Lifesaving
Issued 25 April 1995
Resolved
REPLACE GRABLINES ON ALL RING BUOYS.
Navigation
Issued 27 February 1995
Resolved
INSTALL SECOND STEERING PUMP AS ORIGINAL AND DEMONSTRATE STEERING SYSTEM INTHE PRESENCE OF CG MARINE INSPECTOR.
Construction/Loadline
Issued 17 November 1994
Resolved
Properly remove excessive oil from bilges and provide the Coast Guard documentation of the proper removal.
Lifesaving
Issued 17 November 1994
Resolved
Repair or replace inoperable waterlight on buoyant apparatus on the upper deck.
Lifesaving
Issued 9 November 1994
Resolved
Provide USCG approved waterlights for all Bouyant Apparatus on board IAW 46CFR 180.15. Vessel is restricted from operations at night until waterlights are provided.
Construction/Loadline
Issued 22 September 1994
Resolved
REPAIR HOLE IN PORT SIDE MAIN DECK VICINITY OF PASSENGER'S HEAD.
Lifesaving
Issued 9 June 1994
Resolved
REPLACE THE CYALUME LIFE PRESERVER LIGHTS WITH LIGHTS WHICH COMPLY WITH SOLAS WHEN THEY EXPIRE IN MAY 1996.
Electrical
Issued 9 June 1994
Resolved
REPLACE MISSING GLOBE ON LIGHT FIXTURE IN FUEL TANK SPACE.
Engineering
Issued 9 June 1994
Resolved
PROVIDE PROPOSAL FOR AND INSTALL NATURAL VENT FOR FUEL TANK SPACE.
Construction/Loadline
Issued 9 June 1994
Resolved
REMOVE EXCESS OIL FROM ENGINE ROOM AND FUEL TANK SPACE BILGES.
Accommodation/Occupational Safety
Issued 9 June 1994
Resolved
PROVIDE PROPOSAL FOR PLANNED INSTALLATION OF ADDITIONAL FIXED SEATING FOR PASSENGERS.
Engineering
Issued 9 June 1994
Resolved
REPLACE FUEL TANK VENT SCREENS WITH AN APPROVED FLAME SCREEN.
Construction/Loadline
Issued 21 July 1993
Resolved
REMOVE EXCESS OIL FROM BILGE.
Construction/Loadline
Issued 21 July 1993
Resolved
MAKE THE FORWARD BULKHEAD IN THE ENGINEROOM WATER TIGHT IN WAY OF THE PORT DRIVE SHAFT.
Documentation
Issued 30 June 1993
Resolved
PROVIDE AND RETAIN ON BOARD A COPY OF THE VESSEL'S STABILITY LETTER.
Electrical
Issued 30 June 1993
Resolved
FIX OR REMOVE BATTERY PARALLEL SWITCHES ON CONSOLE.
Lifesaving
Issued 30 June 1993
Resolved
PROVIDE LIGHTS FOR ALL LIFE JACKETS.
Navigation
Issued 30 June 1993
Resolved
FIX HYDRAULIC LEAK IN STEERING GEAR.
Fire Fighting
Issued 30 June 1993
Resolved
PROVIDE ADEQUATE HOSE FOR HAND PORTABLE FIRE PUMP CAPABLE OF REACHING THE WATER FROM THE VESSEL.
Electrical
Issued 5 August 1992
Resolved
PROPERLY SECURE DANGLING WIRES IN PAX COMPARTMENT, STBD SIDE, FORWARD. _x001C_ WIRES APPEAR TO BE LEFT OVER FROM PREVIOUS SPEAKER INSTALLATION.
Construction/Loadline
Issued 5 August 1992
Resolved
REPAIR/REPLACE FASTENERS FOR OVERHEAD PFD STOWAGE BOX ON PORT SIDE.
Construction/Loadline
Issued 5 August 1992
Resolved
REPLACE MALFUNCTIONING DOG ON FUEL COMPT. HATCH.
Accommodation/Occupational Safety
Issued 5 August 1992
Resolved
PROPERLY SECURE LOWER PORTION OF THE LADDER LEADING FROM THE MAINDECK_x001C_ TO ENGINE ROOM.
Electrical
Issued 5 August 1992
Resolved
PROPERLY MOUNT DANGLING LIGHTS IN ENGINE ROOM. LIGHTS MUST BE INSTALLED_x001C_ W/PROTECTIVE COVERS.
Accommodation/Occupational Safety
Issued 5 August 1992
Resolved
REPLACE MISSING BOLTS ON LADDER LEADING TO THE UPPER DECK ROOF.
Engineering
Issued 30 June 1992
Resolved
Repair and demonstrate operation of power blowers in engine room. Exhaust blowers shall be ducted to the bottom of the bilge.
Electrical
Issued 30 June 1992
Resolved
Provide de-rated specification plate for generator for ambient temperature of 50 degrees Centigrade. Present plate is rated for ambient temperature of 40 degrees Centigrade.
Construction/Loadline
Issued 30 June 1992
Resolved
Secure hydraulic pump for trim tabs located in men's head.
Lifesaving
Issued 30 June 1992
Resolved
Properly rig the hydrostatic releases on the aft liferafts.
Lifesaving
Issued 30 June 1992
Resolved
Stencil lifejacket boxes with the number and type of jacket located within.
Electrical
Issued 30 June 1992
Resolved
Properly wire public address system located in pilot house.
Fire Fighting
Issued 30 June 1992
Resolved
Properly mount fire extinguisher in pilot house.
Lifesaving
Issued 30 June 1992
Resolved
Repair or replace cracked cannister containing life raft on outboard port side aft.
Accommodation/Occupational Safety
Issued 30 June 1992
Resolved
Repair and prove operation of sink in men's head.
Electrical
Issued 30 June 1992
Resolved
Provide cover for electric panel in women's head.
Electrical
Issued 30 June 1992
Resolved
Provide protective guards for belts on generator engine.
Electrical
Issued 30 June 1992
Resolved
Provide cover for battery box in pilot house.
Engineering
Issued 30 June 1992
Resolved
Label emergency fuel shutdowns located in main passenger cabin.
Construction/Loadline
Issued 30 June 1992
Resolved
Provide bolts for deck plate in aft area above engine room.
Lifesaving
Issued 30 June 1992
Resolved
Provide lifejacket donning procedures placard for all types of lifejackets on board vessel. Provide a minimum of one placard per deck.
Electrical
Issued 30 June 1992
Resolved
Remove DC switch board and associated unused wiring on starboard side of the pilot house.
Electrical
Issued 29 June 1990
Resolved
UPON COMPLETION OF NEW WIRING INSTALLATION MAKE WATERTIGHT THE CABLE RUNS BETWEEN ENGINE ROOM AND FUEL SPACE.
Fire Fighting
Issued 29 June 1990
Resolved
PROVIDE A 75FT FIRE HOSE SO HOSE MAY REACH ALL PORTIONS OF THE VESSEL.
Navigation
Issued 29 June 1990
Resolved
PROVIDE AN 8" BELL AS REQUIRED BY RULES OF THE ROAD.
Lifesaving
Issued 29 June 1990
Resolved
PROVIDE WHISTLES FOR ALL PFD'S AS REQUIRED BY SOLAS.
Lifesaving
Issued 29 June 1990
Resolved
PROVIDE SIX ADDITIONAL ROCKET FLARES AS REQUIRED BY SOLAS FOR A TOTAL OF TWELVE.
Navigation
Issued 29 June 1990
Resolved
PROVIDE A SSB RADIO AS REQUIRED BY SOLAS.
Construction/Loadline
Issued 29 June 1990
Resolved
INSTALL A VALVE FOR THE BILGE SUCTION AT THE COLLISION BULKHEAD WITH THE APPROPRIATE REACH ROD TO SECURE THE VALVE.
Construction/Loadline
Issued 19 June 1990
Resolved
REPLACE WASTED NIPPLE AT COLLISION BULKHD WHICH IS THE MAIN LINE FOR PUMPING THE FWD PEAK TANK.
Construction/Loadline
Issued 19 June 1990
Resolved
REPAIR 1/2" HOLE IN BOTTOM PLATING LOCATED IN BILGE AREA STBD SIDE WHERE ENGINE BED MEETS FWD BULKHD. FILLET WELD INSIDE AND OUTSIDE FOR FULL PENETRATION.
Electrical
Issued 6 August 1987
Resolved
PLACE LIGHT GLOBES OR DOMES ON ALL LIGHT FIXTURES AS NEEDED.
Lifesaving
Issued 6 August 1987
Resolved
PLACE A SUITABLE AMOUNT OF RETROFLECTIVE TAPE ON EACH LIFE PRESERVER AS REQUIRED BY 46 CFR 180.25-25.
Engineering
Issued 20 December 1985
Resolved
DOUBLE HOSE CLAMP EACH END OF ALL FLEXABLE HOSE COUPLINGS ON ENGINE INTAKESAND EXHAUSTS.
Electrical
Issued 20 December 1985
Resolved
REMOVE ALL DISCONTINUED AND UNUSED WIRING IN ENGINE COMPARTMENT.
Electrical
Issued 20 December 1985
Resolved
REMOVE ALL DISCONTINUED AND UNUSED WIRING IN FUEL TANK COMPARTMENT.
Engineering
Issued 20 December 1985
Resolved
REMOVE ALL OIL AND WATER FROM ENGINE COMPARTMENT BILGE.
Casualty record · 2
28 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4365267
3 November 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4374985
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
ISLAND PRINCESS (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National