Records from 1982 to 1991. Most recent: inspection, 25 January 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
25 January 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1224170
4 June 1990
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1223493
17 April 1990
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1217945
16 April 1990
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 924574
14 June 1989
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 898549
27 April 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1041917
28 October 1987
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1018590
1 July 1987
COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1318778
22 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331743
20 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319698
12 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988916
9 June 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985297
9 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291758
28 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1288020
24 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979267
16 January 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285289
27 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973136
11 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281878
14 February 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279976
2 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 968894
9 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1276686
9 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281147
17 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966815
15 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274041
14 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966505
Documentation
Issued 4 June 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Documentation
Issued 4 June 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Lifesaving
Issued 27 April 1988
Resolved
PROVIDE PFD LIGHTS FOR ALL PFD'S.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Navigation
Issued 27 April 1988
Resolved
PROVE OPERATION OF DRILL FLOOR AIR RECIEVER POP-OFF VALVE.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Electrical
Issued 27 April 1988
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Lifesaving
Issued 27 April 1988
Resolved
REPAIR AS NECESSARY AND PROVE OPERATIONS OF ELECTRICAL CONTROLS AND LIMIT SWITCHES TO NUMBER TWO(2) LIFEBOAT WINCH AND NUMBER ONE(1) LIFEBOAT WINCH.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Electrical
Issued 27 April 1988
Resolved
REPAIR AS NECESSARY AND PROVE OPERATION OF GENERAL ALARMS IN GENERATOR ROOMAND FIRST DECK QUARTERS AND PORT SIDE BOOBY HATCH.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Lifesaving
Issued 27 April 1988
Resolved
REPAIR AS NECESSARY AND PROVE OPERATIONS OF COOLING SYSTEM,STEERING SYSTEM AND REVERSE GEAR TO NUMBER ONE(1) LIFEBOAT.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Documentation
Issued 27 April 1988
Resolved
PROVIDE ON BOARD A CG APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Lifesaving
Issued 27 April 1988
Resolved
PROVIDE ON BOARD AT ALL TIMES THE REQUIRED NUMBER OF CERTIFICATED LIFEBOAT-MEN.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Documentation
Issued 27 April 1988
Resolved
PROVIDE CORRECT OWNER/ OPERATOR ADDRESS CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Deck/Cargo
Issued 9 May 1985
Resolved
PROVIDE PROOF OF TEST DATE FOR OIL TRANSFER HOSE OR REPLACE WITH NEW TESTED46 CFR 15.800
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Lifesaving
Issued 9 May 1985
Resolved
HAVE THE TWO (2) INFLATIBLE LIFERAFTS WITH HYDROSTATIC RELEASE SERVICED AT A USCG APPROVED SERVICING FACILITY. 46 CFR 107.231(B)
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Unknown
Issued 9 May 1985
Resolved
PROVIDE ONE (1) BURN BLANKET FOR HOSPITAL SPACE. 46 CFR 108.497
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Lifesaving
Issued 9 May 1985
Resolved
UPON RECEIPT OF USCG MMT (8TH DISTRICT) APPROVAL OF NEW LIFEBOAT STATION, RESUBMIT LIFESAVING AND FIRE CONTROL PLAN FOR APPROVAL. 46 CFR 107.305.
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Engineering
Issued 9 May 1985
Resolved
AT NEXT SCHEDULED SPECIAL EXAM IN LIEU OF DRYDOCKING AT NEXT RIG MOVE, MAKEAVAILABLE 3 RIG AIR RECEIVERS FOR INTERNAL EXAMINATION AND RELIEF VALVE TESTING IN THE PRESENCE OF A USCG INSPECTOR. 46 CFR 61.10.
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Deck/Cargo
Issued 9 May 1985
Resolved
PROVIDE EVIDENCE TO [name withheld], LA THAT BOTH CRANES HAVE HAD QUADRENNIAL AND ANNUAL CRANE INSPECTION BY A USCG APPROVED CRANE CERTIFYINGAUTHORITY. 46 CFR 107.258
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Unknown
Issued 9 May 1985
Resolved
PROVIDE EVIDENCE THAT THE TWO (2) NEW MSA 02/LEL METERS ARE EITHER FM/UL/ OR CS APPROVED OR REPLACED THESE METERS WITH APPROVED METERS. 46 CFR 108.497
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Lifesaving
Issued 9 May 1985
Resolved
PROVIDE TWO (2) ADITIONAL WATER LIGHTS WITH LANYARDS FOR TWO (2) RINGBUOYS.46 CFR 108.515
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Deck/Cargo
Issued 9 May 1985
Resolved
PROVIDE APPROVED OIL TRANSFER PROCEDURES AND POST SAME ON RIG. 46 CFR 155.720
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Unknown
Issued 9 May 1985
Resolved
THE BELOW LISTED DEFICIENCIES PERTAIN TO THE MODU KEYES 150, O.N. 607885. THE BELOW LISTED ITEMS ARE TO BE COMPLIED WITH BY 09JUN85.
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985
Lifesaving
Issued 28 February 1985
Resolved
PERFORM AN ACCEPTABLE NDT OF WELDING DONE IN THE INSTALLATION OF THE ESCAPECAPSULE DAVIT ASSEMBLY. THESE REQUIREMENTS ARE TO BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI AND ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Unknown
Issued 28 February 1985
Resolved
SUBMIT PROPOSAL TO REMOVE OBSTRUCTION IN WAY OF FLIGHT PATH TO HELOCOPTER FLIGHT DECK(ESCAPE CAPSULE WINCH ASSEMBLY AND GUARD RAIL).
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Lifesaving
Issued 28 February 1985
Resolved
SUBMIT PLANS FOR ESCAPE CAPSULE INSTALLATION TO CCGD8(MMT) NEW ORLEANS FOR PLAN REVIEW ANS APPROVAL.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Unknown
Issued 27 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU KEYES 150, DN6078845
Condition: Unknown
Due 27 April 1984
Resolved 27 April 1984
Electrical
Issued 27 April 1984
Resolved
REPAIR PURGE AIR ALARM IN THE DRILLERS CONSOLE. 46CFR111.92
Condition: Unknown
Due 27 April 1984
Resolved 27 April 1984
Fire Fighting
Issued 27 April 1984
Resolved
PROVIDE A B-V SEMI PORTABLE FIRE EXTINGUISHER FOR THE HELICOPTER DECK ACCESS ROUTE. 46CFR108.493.
Condition: Unknown
Due 27 April 1984
Resolved 27 April 1984
Electrical
Issued 27 April 1984
Resolved
PROVIDE A GENERAL ALARM IN THE MAIN GENERATOR SPACE. 46CFR113.25
Condition: Unknown
Due 27 April 1984
Resolved 27 April 1984
Lifesaving
Issued 14 June 1982
Resolved
PROVIDE RIG WITH (1) ONE RING BOUY WITH SMOKE ATTACHED.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Electrical
Issued 14 June 1982
Resolved
PROVIDE BUNK LIGHTS AND COVERS FOR QUARTERS AREAS
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Electrical
Issued 14 June 1982
Resolved
REPAIR OR REPLACE THE DRAWWORKS VENTILATION INTERLOCK
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Electrical
Issued 14 June 1982
Resolved
LOCATE AND REPAIR ELECTRICAL GROUND INDICATED BY EMERGENCY GENERATOR CIR- CUIT GROUND DETECTOR.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Electrical
Issued 14 June 1982
Resolved
REPAIR OR REPLACE OVERSPEED TRIP ON #2 GENERATOR ENGINE.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Construction/Loadline
Issued 14 June 1982
Resolved
APPLY NON-SKID TO THE HELO DECK.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Electrical
Issued 14 June 1982
Resolved
REMOVE PLASTIC TIE WRAPS FROM ELECTRICAL WIRING ADJACENT TO SHALE SHAKER AND PROPERLY STRAP.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Accommodation/Occupational Safety
Issued 14 June 1982
Resolved
REMOVE TAPE FROM FLEX VENT OVER DRAW WORKS MOTORS AND RENEW WITH PROPER FLEX MATERIAL.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Electrical
Issued 14 June 1982
Resolved
MAKE THE SWACO CHOKE PANEL SUITABLE FOR INSTALLATION IN HAZARDOUS AREA.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Documentation
Issued 14 June 1982
Resolved
PROVIDE RIG WITH APPROVED FIRE CONTROL AND SAFETY PLAN
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Construction/Loadline
Issued 14 June 1982
Resolved
COMPLETE DRYDOCK EXAM
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982
Unknown
Issued 14 June 1982
Resolved
PROVIDE RIG WITH APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 14 June 1982
Resolved 14 June 1982