Records from 2009 to 2025. Most recent: inspection, 2 December 2025.
Inspection history · 17
2 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8276406
6 August 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8195482
18 July 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7960995
8 December 2023
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7837318
7 June 2023
Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7712741
20 April 2023
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7672247
9 May 2022
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7444810
9 December 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7365721
18 May 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7205308
16 July 2020
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7081883
5 December 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6867691
29 May 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6696239
11 July 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6440817
11 December 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6338275
20 April 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6128923
26 July 2016
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5989259
22 June 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5915105
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 August 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. On both the port and starboard engines there are exposed rotating belts that require protection to be installed.
46 CFR 177.35-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 2 September 2025
Resolution: Recieved pictures from the operator with the installed protection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 August 2025
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. The starboard engine fuel shutoff is missing the labeling.
46 CFR 185.30-20 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 9 August 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 June 2023
Resolved
Fireboy failed to Stop stbd side engine. Troubleshoot and repair. Test to the satisfaction of the Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2023
Resolution: Fire testing company, replaced harness and override control. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023
Resolved
Vessel missing 09 lifejackets, Restricted to 55 persons on board when operating inside 3NM
Action required: 705 - Other - as specified
Resolved 7 June 2023
Resolution: Vessel purchased new lifejackets. Restriction removed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 June 2023
Resolved
Vessel missing lifefloat. Vessel has one 12 pax lifefloat onboard. Restricted to 24 pax onboard when operating outside 3NM.
Action required: 705 - Other - as specified
Resolved 18 July 2024
Resolution: Life raft inspected. All Sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 June 2023
Resolved
Engines are covered in oil. Clean and remove all oil residue. Clean both alternators to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2023
Resolution: Vessel removed excess oil and clean both alternators.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 June 2023
Resolved
During firepump test, system failed o provide water pressure and flow. Troubleshoot and repair to the Satisfaction of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2023
Resolution: Vessel replaced 15 feet of piping. Adjusted belt and tested system. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2023
Resolved
Cable fot throttle of portside engine is been held with a ziptie. Replace with manufacters pin and test.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2023
Resolution: Replaced ziptie with manufacter parts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 June 2023
Resolved
Exhaust leak was found on stbd side engine. Repair to the satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2023
Resolution: Vessel replaced exhaust piping and lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2023
Resolved
During Inspection MIs found 29 Lifejackets with wasted retroreflective Solas tape, 19 unserviceable Lifejackets. Replaced all condemned lifejackets and replace retroreflective tape on others. Vessel Restricted to 17 PAX until all life jackets have been serviced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Vessel purchased 20 New life jackets and replaced all retro reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 April 2023
Resolved
Both life floats are unserviceable, Material, nets, grab lines and equipment are completely deteriorated and need to be send for repairs or replace with new. Vessel restricted to 3NM
Action required: 705 - Other - as specified
Resolved 18 July 2024
Resolution: Life raft inspected. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2023
Resolved
Bilge high water level alarm inside engine room not working. Replace with new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: New float for alarm was installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2023
Resolved
Portside exhaust muffler is leaking and needs to be repair to the satisfaction of Marine Inspector
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2023
Resolution: Exhaust muffler was replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2023
Resolved
Starboard side fire pump housing is leaking, Replace gasket and test to the satisfaction of Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2023
Resolution: New gasket was installed on jabsco pump. Test Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2023
Resolved
Steering system hydraulic ram is loose and needs to be re adjusted
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Vessel removed incorrect bolts and use shorter allowing ram to be adjusted. Test Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2023
Resolved
There's an open bucket full of fuel in engineroom. Removed before operating with Pax
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2023
Resolution: Bucket was removed from engine room
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2023
Resolved
Theres a thruhull valve that could be open to the outside without any hoses after water system was removed. Plug valve
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Vessel plugged Thruhull valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2023
Resolved
Stbd side Battery terminal is loose and broke. Replace with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2023
Resolution: New terminals were installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2023
Resolved
All new Cable connections need to be inside junction boxes. Changed to code 50. Operator working on replacing them all.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 July 2024
Resolution: Cables properly terminated.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2023
Resolved
EPIRB Hydrostatic release is expired. Replace with new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2023
Resolution: Vessel purschased and installed new EPIRB Hydrostatic release
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 May 2021
Resolved
A pre engineer fixed gas fired system must... of not more than 2000sq. There are 5 holes in the engine room overhead that leads to the main deck, this could allow fire extinguishing to escape space creating a fire risk. 46CFR181.400 (b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2021
Resolution: Vessel covered holes with plates.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 May 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level... Space #2 audible alarm wasn't working. Replace with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2021
Resolution: Operator purchase new alarm indicator. Test sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 May 2021
Resolved
Each hatch exposed to the weatherdeck must be watertight...All hatch covers gasket are unserviceable. Replace with new IAW with manufactures specifications. 46 CFR 171.124(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2021
Resolution: Vessel replaced Gaskets with new ones.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2021
Resolved
All cables and wires must, be installed with metal supports not more than 24 inches apart. Cables were attached with zip ties. Recommend to add metal support in addition to plastic ones.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2021
Resolution: Vessel added metal supports every 24 inches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 May 2021
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Cable runs on engine room bulkhead was not sealed. Sealed with fire resistance material. 46 CFR 171.114
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2021
Resolution: vessel sealed all penetrations with fire resistance foam.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 May 2021
Resolved
It shall be the duty of the master of any vessel subject to the regulation in this subchapter to prepare and post emergency checkoff list in a conspicuous place accessible to crew and passengers... All emergency procedures placards were missing. Acquired and post new ones as per regulation.
46 CFR 185.25-1
Action required: 10 - Deficiency Rectified
Resolved 18 May 2021
Resolution: Crew printed and posted instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021
Resolved
Each life preserver carried on board must have reflective material attached on its front side.... all reflective material was deteriorated and unserviceable. Replace with new material as per regulations. 46 CFR 180.25-25
Action required: 10 - Deficiency Rectified
Resolved 18 May 2021
Resolution: Crew replaced all reflective material prior to MI departure.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2017
Resolved
PROVIDE VISUAL INDICATOR LIGHT FOR HIGH LEVEL ALARM IN LAZARETTE. 46 CFR 185.530(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 23 May 2017
Resolution: PROVIDED VISUAL INDICATOR LIGHT FOR HIGH LEVEL ALARM IN LAZARETTE.