MAURY USCG vessel records Sign in
← All vessels

HOS DEEPWATER

HOS DEEPWATER is a 1999 offshore supply vessel. The Coast Guard has recorded 27 inspections since 1999, most recently in March 2021, along with 24 deficiencies.

Records from 1999 to 2021. Most recent: inspection, 29 March 2021.

Built
1999
Last inspected
29 March 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9221841 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
503417
Flag
MEXICO
—
Maury page id
psix-503417

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (1999–2021)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1549 - Convention (Subpart B), Gross Ton
464 - Convention (Subpart B), Net Ton
3625 - Displacement, Metric Ton
2295 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

29 March 2021 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7163376
30 August 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6495253
3 April 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116502
21 July 2008 Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3278977
10 December 2007 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3112847
19 September 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2782100
6 September 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2770965
18 July 2006 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2716764
31 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2576502
31 January 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576510
25 January 2006 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2580944
9 November 2004 Cargo Tank Internal · Annual Inspection · Internal Structural Exam
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2265582
7 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066397
20 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048403
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979372
23 October 2003 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1934475
7 July 2003 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1838339
19 February 2003 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1746493
9 September 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1673211
9 July 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1643374
13 May 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1631132
10 January 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1476391
20 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1479737
20 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1643316
30 November 2001 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 773200
6 November 2001 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1075929
9 November 1999 COI Inspection · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454745

Deficiency record · 24

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 29 March 2021 Resolved
After any survey of the ship has been completed, no changes shall be made to the equipment covered by the survey, without the sanction of the Administration. Vessel's liferafts and lifejackets are not in compliance with the Cargo Ship Safety Equipment Certificate Form E. Only 48 lifejackets and 04 liferafts were on board when 101 lifejackets and 06 liferafts are required. Solas 74 (2020 Cons.) I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 30 March 2021
Resolution: Received photo evidence and service certificates for 06 life rafts installed on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 29 March 2021 Resolved
The Continuous Synopsis Record shall be kept on board the ship and shall be available for inspection at all times. The most current CSR was not on board for Coast Guard inspection. Solas 74 (2020 Cons.) XI-1/5.10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 30 March 2021
Resolution: Received CSR application for the HOS DEEPWATER, issued by SEMAR (Mexico)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
13199- Other (machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, or persons on board. PSCO observed steering gear malfunction. A technician was on board and stated that the control valves are currently malfunctioning and that steering gear pump number 02 is in need of maintenance. SOLAS 74 (2001) I / Reg. 11 60b/a
Action required: 60 - Rectify deficiencies prior to movement
Due 30 August 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS attesting to satisfactory repairs made to the steering gear system.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 August 2018 Resolved
07103- Division – Decks, bulkheads, and penetration -Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed hold back devices on self-closing fire doors throughout the engine room space and in the galley. This included self-closing watertight doors. SOLAS 74 (2001) II-2 / Reg. 47.2 17b/a
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. Attending surveyor noted that hold backs in the engine room were removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2018 Resolved
07110 – Fire fighting equipment and appliances- Fixed fire detection and fire alarm systems shall be monitored for loss of power or fault conditions as appropriate. PSCO observed that the alarm panel at the operating station is indicating a fault. SOLAS 74 (2001) II-2 / Reg. 13.1.2 17b/a
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. One fuse was replaced and a technician reported no faults on a 04SEP18 FPS report. During attendance, the attending ABS surveyor witnessed no faults on the alarm panel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 August 2018 Resolved
07109 – Fixed fire extinguishing installation- Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed 02 hoses from Co2 cylinders to the manifold in deteriorated condition. SOLAS 74 (2001) II-2 / Reg. 21 17b/a
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. Seven (07) ¾ inch Kiddie Fixed System hoses were replaced as new per 31AUG18 Coastal States FFST, INC. report. The attending ABS surveyor noted the seven (07) new hoses.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 August 2018 Resolved
03109 – Machinery Space Openings- The means for securing and monitoring weather tightness shall be to the satisfaction of the Administration. PSCO observed that the gasket to the emergency exit in the starboard side of the engine room was missing. ILLC ANNEX I / Chapt. II / Reg. 16.4 17b/a
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. The gasket was replaced new with no light and considered watertight by the attending ABS surveyor.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 30 August 2018 Resolved
01117 – International Oil Pollution Prevention (IOPP) - The Administration shall fully guarantee the completeness and efficiency of the survey. PSCO observed that the IOPP supplement had oil content meter type and filtering equipment marked incorrectly. MARPOL ANNEX I / Reg. 6.3.4 50b/a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. The attending surveyor noted that the IOPP supplement was corrected, and marked accordingly as having MEPC.60(33) components.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2018 Resolved
11118 – Lifejackets incl. provision and disposition- A sufficient number of life jackets shall be carried for persons on watch and for use at remotely located survival craft stations. PSCO observed that the watch stander life jackets in the machinery space were unserviceable. SOLAS 74 (2001) III / Reg. 7.2.2 50b/a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. The two (02) port and starboard life jackets were replaced in the machinery space.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 30 August 2018 Resolved
01132 - Tonnage Certificate-Gross tonnage and Net Tonnage shall be determined in accordance with the provisions of these regulations. PSCO observed that the vessel does not have a valid International Tonnage Certificate. Tonnage Convention (67) Annex I / Reg.1 III 17b/a
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2018
Resolved 26 September 2018
Resolution: PSC Houma received a class report from ABS satisfying the requirement. The vessel was issued a new International Tonnage Certificate on 13SEP18, and verified onboard by the attending ABS surveyor.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 December 2007 Resolved
Replace STBD Side engineroom escape hatch.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 20 December 2007
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 10 December 2007 Resolved
Test automation IAW approved automation test procedures.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 20 December 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 6 September 2006 Resolved
Inspect rescue harness, log in inspection book and provide purchase date.
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corected
Lifesaving › Buoyant Apparatus › Serviceable
Issued 6 September 2006 Resolved
Stencil rescue basket, note servicable condition and provide reflective tapeas per cfr.
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2006 Resolved
Provide SOLASapproved medical first aid kit
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Lifesaving › Buoyant Apparatus › Lifeline
Issued 6 September 2006 Resolved
Correct all life ring line deficiencies.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 6 September 2006 Resolved
Provide and install prop guard on rescue boat as per SOLAS .
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 6 September 2006 Resolved
Repair lights on switchboard platform in engine room light covers, hanging fixture.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Engineering › Fuel Oil Service System › Filter
Issued 6 September 2006 Resolved
Remove plastic plugs on all raycor filters on main engines and generators and install metal plugs.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Communications › Alarms/Indicators › General Alarm
Issued 6 September 2006 Resolved
Demonstrate proper operation of general alarm audible and visual indicators in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Electrical › Electric Supply System (service) › Transformer
Issued 6 September 2006 Resolved
Renew wiring as per 46 CFR on voltage regulator in engine room.
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Construction/Loadline › Structures › Door
Issued 6 September 2006 Resolved
Demonstrate proper operation of main deck WTD .
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 September 2006 Resolved
Install safety chains at bits on main deck to measure 39 inches as per 46 CFR.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2006
Resolved 7 September 2006
Resolution: Corrected
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2002 Resolved
INSERT IWO #18 F/O TK SIDE SHELL PLATE (1) 66IN X 78IN PLATE AND (1) 91IN X 132IN X 6FT SIDE SHELL PLATE. INSERT IWO #18 F/O TK (1) 38IN X 30IN N/T BLKD, (1) 30IN X 40IN N/T BLKD PLATES. C/R IWO #NO18 F/O TK NUMERUOUS SIDE SHELL ANGLES. WITNESS NDT OF ALL REPAIRS.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2002
Resolved 8 January 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.