MAURY USCG vessel records Sign in
← All vessels

CHAMP

CHAMP is a 1979 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1984, most recently in May 2003, along with 139 deficiencies and 1 casualty investigation in 2002.

Records from 1984 to 2003. Most recent: inspection, 23 May 2003.

Built
1979
Last inspected
23 May 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCI4190
Flag
UNITED STATES
366720930 (licence lapsed)
Maury page id
psix-50342

Inspections, by type

…with no type recorded23
Years with a record 20 calendar years (1984–2003)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Net Ton
88 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCW6684MMSI 366720930 · expired · voluntarily equipped · granted 17 June 1996, cancelled 19 August 2006
WCI4190MMSI not assigned · expired · voluntarily equipped · granted 8 June 1994, cancelled 8 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

23 May 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1799917
8 May 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1814422
3 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714330
30 September 2002 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1682072
8 August 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1658764
24 July 2002 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1651585
12 June 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1629914
16 April 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1605567
14 February 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1486584
30 November 2001 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1431133
10 July 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1423611
26 June 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379492
23 May 2001 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1066353
23 April 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1412313
29 June 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1051863
21 June 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1050675
20 June 2000 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1050935
13 June 2000 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1051136
16 May 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1404978
17 April 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1464274
12 August 1999 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 776641
7 April 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 787399
16 March 1999 Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1453559
21 June 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 794214
5 May 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471516
5 May 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471517
22 July 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 649005
17 July 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1383615
14 June 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 649006
9 June 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 774711
9 June 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386010
27 May 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 76215
27 May 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455485
13 May 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378049
18 April 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1431760
12 March 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213429
23 August 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1092868
22 August 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 139088
16 May 1996 Damage Survey · Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1359164
15 May 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 717805
14 December 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 152150
12 April 1995 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1358725
4 May 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379964
12 April 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 856854
18 June 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391860
14 April 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1452938
15 July 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1253106
26 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 955102
9 April 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 948188
2 April 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 948189
25 October 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1250867
16 October 1991 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1405304
26 April 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 924517
3 April 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1232734
4 April 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 910841
21 March 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 902521
5 July 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 897833
2 June 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195773
30 May 1989 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1275925
23 December 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 898724
1 June 1988 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1031600
17 December 1987 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1006094
13 May 1987 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1017778
9 April 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1331300
5 March 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1007645
2 May 1986 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1003225
21 April 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991499
18 December 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 994385
10 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 984487
26 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 984002
15 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1286536
11 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288030
21 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976253

Deficiency record · 139

Communications › Radio Communications
Issued 12 June 2002 Resolved
Provide FCC operators license. LEGACY COMPONENT DESC: FCC Operators license
Due 10 July 2002
Resolved 26 June 2002
Communications › Radio Communications
Issued 12 June 2002 Resolved
Provide emergy broadcast placard. LEGACY COMPONENT DESC: Broadcast Placard
Due 10 July 2002
Resolved 25 July 2002
Stability › Watertight Integrity
Issued 12 June 2002 Resolved
Seal bulkhead penetrations in engine room. LEGACY COMPONENT DESC: Bulkhead Penetrations
Due 10 July 2002
Resolved 25 July 2002
Engineering › Fuel Oil Service System
Issued 12 June 2002 Resolved
Bond fuel fill to tank. LEGACY COMPONENT DESC: Fill Pipe
Due 10 July 2002
Resolved 25 July 2002
Electrical › Electric Supply System (service)
Issued 12 June 2002 Resolved
Install blanks for missing breakers in engine room power panel. LEGACY COMPONENT DESC: Power Panel
Due 10 July 2002
Resolved 25 July 2002
Electrical › Electric Supply System (service)
Issued 12 June 2002 Resolved
Remove or use dead-end wires in fuel comp. LEGACY COMPONENT DESC: Wiring
Due 10 July 2002
Resolved 25 July 2002
Fire Fighting › Fire Pumps
Issued 12 June 2002 Resolved
Repair fire pump ele. box. LEGACY COMPONENT DESC: Control Box
Due 10 July 2002
Resolved 25 July 2002
Fire Fighting › Fire Hoses
Issued 12 June 2002 Resolved
Replace fire hose on starb station.
Due 10 July 2002
Resolved 8 August 2002
Pollution Prevention/Response › Prevention Equipment
Issued 12 June 2002 Resolved
Repair Laz. bilge alarm. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 12 June 2002 Resolved
Repair or replace generator exhaust pipe at transom pedro.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Operations/Management › Drills/Instruction
Issued 12 June 2002 Resolved
Conduct drills to the satisfaction of attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Operations/Management › Drills/Instruction
Issued 12 June 2002 Resolved
Construct a man overboard ladder or platform to enable the recovery of an unconscious person from the water without putting a crewman in the water.
Due 10 July 2002
Resolved 8 August 2002
Construction/Loadline
Issued 26 June 2001 Resolved
SEAL STBD ENGINE EXHAUST PIPE BLKHD PENETRATION INTO LAZARETTE.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Navigation
Issued 26 June 2001 Resolved
Replace hydraulic line hangers that are broken in the lazarette.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Electrical
Issued 26 June 2001 Resolved
Remove dead ended electrical cable in the port lazarette stowage space.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Construction/Loadline
Issued 26 June 2001 Resolved
Seal hole through watertight blkhd in port lazarette area.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
Replace valve handle on fresh water tanks in aft berthing.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Engineering
Issued 26 June 2001 Resolved
Install flame screen for aft fuel tank vent.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
Install vent screen on MSD tank vent.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Lifesaving
Issued 26 June 2001 Resolved
Replace outdated items in first aid kit.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
Mark escape hatches and attach handles IAW46CFR 177.500 (h)(I) and 185.606.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
Install required guards on lights in the berthing areas.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Fire Fighting
Issued 26 June 2001 Resolved
Replace/repair smoke detector in aft berthing.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
Install more visible lettering on the aft emergency exit.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
Repair broken AC ducting in berthing areas.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Electrical
Issued 26 June 2001 Resolved
Cover all blanks in engineroom power panel port side aft.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Construction/Loadline
Issued 26 June 2001 Resolved
Provide proper anchoring device for the anchor line in the forepeak to the hauspipe.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Construction/Loadline
Issued 26 June 2001 Resolved
Replace hose clamp on bilge suction in the lazarette.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Navigation
Issued 26 June 2001 Resolved
Repair stern light.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 26 June 2001 Resolved
Replace flexible trunk to supply ventillation on STBD blower for engineroom.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Electrical
Issued 26 June 2001 Resolved
Clean generator windings of dirt and oil.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Construction/Loadline
Issued 26 June 2001 Resolved
Replace gasket to lazarette hatch cover.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Engineering
Issued 26 June 2001 Resolved
Label fuel shutoff to aft fuel tank IAW46CFR 185.608
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Construction/Loadline
Issued 26 June 2001 Resolved
Install valve on bilge suction for the forepeak, reachable from the deck IAW46CFR 182.510(d).
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Engineering
Issued 26 June 2001 Resolved
BOND AFT FUEL TANK FILL.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Construction/Loadline
Issued 23 May 2001 Resolved
Repair damaged stbd side boarding door prior to carrying passengers.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Electrical
Issued 16 May 2000 Resolved
Enclose wire nuts in J Box for lazarette bilge alarm.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Properly secure rudder angle indicator connection in Lazarette.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Seal bulkhead penetrators in Lazarette STBD side.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Install cover on overhead light in Galley.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Tighten and secure bilge pump piping.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Engineering
Issued 16 May 2000 Resolved
Install 30 X 30 micron mesh in fuel tank vents.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Engineering
Issued 16 May 2000 Resolved
Fix all hydraulic leaks and clean same.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Electrical
Issued 16 May 2000 Resolved
Fill in empty holes in E/R breaker box.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Fire Fighting
Issued 16 May 2000 Resolved
Replumb fire pump so the pump does not lose suction.
Condition: Unknown
Due 26 May 2000
Resolved 30 May 2000
Electrical
Issued 16 May 2000 Resolved
Enclose washdown pump wiring in J box or other suitable means.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Engineering
Issued 16 May 2000 Resolved
Replace E/R vent covers (cloth).
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Navigation
Issued 16 May 2000 Resolved
Install rudder stops on rudders.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Unknown
Issued 16 May 2000 Resolved
Conduct complete and thorough ISM audit.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Engineering
Issued 16 May 2000 Resolved
Seal port side exhaust leak above wash down pump, leaks water.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Secure fan in Galley, install cover over fan discharge.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Documentation
Issued 16 May 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Documentation
Issued 16 May 2000 Resolved
Prove all Master's listed in ISM have FCC operator's license.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Enclose wire nuts in J boxes for bilge alarm.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Enclose wire nuts in J box or cap for reefer solenoid.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000 Resolved
Renew life jacket placard to represent number of adult and children's life jackets.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Secure pump in AFT berthing.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Install light covers in Aft berthing.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Prove proper operation of all bilge alarms both audio and visual.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Clean oil & debris from E/R bilge.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Electrical
Issued 16 May 2000 Resolved
Clean bait pump (P&S) motors, renew guard.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Navigation
Issued 16 May 2000 Resolved
Correct Charts IAW ISM Manual P48.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000 Resolved
Install and prove proper operation of PFD lights.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Unknown
Issued 16 May 2000 Resolved
Update ISM manual: p19 COI 5 YR, p28 finish section, add Master [name withheld],delete [name withheld].
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Seal stern light in Lazarette.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Accommodation/Occupational Safety
Issued 16 May 2000 Resolved
Clean Galley throughly, kill roaches.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Documentation
Issued 16 May 2000 Resolved
Provide copy of 1999 MIS report.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Install light cover in FWD berth.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Accommodation/Occupational Safety
Issued 16 May 2000 Resolved
Bring MSD drainage system into conformance with Federal & State regulations.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Secure bilge pump.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Label bilge manifold.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Fire Fighting
Issued 16 May 2000 Resolved
Prove proper operation of fixed fire suppression system.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Navigation
Issued 16 May 2000 Resolved
Prove proper operation of steering system to satisfaction of marine inspector.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Engineering
Issued 16 May 2000 Resolved
Seal thru-hull in engine room, port side
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Construction/Loadline
Issued 16 May 2000 Resolved
Remove water from fore and aft berthing bilges.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Navigation
Issued 16 March 1999 Resolved
Repair worn steering ram base & missing keeper pin @ port ram.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Documentation
Issued 16 March 1999 Resolved
Update ISM program checks & audits per attached worklist. Vessel restrictedto zone 2 domestic routes or less until this requirement is satisfied. Vessel's SOLAS certificates to be reissued on completion.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Electrical
Issued 16 March 1999 Resolved
Replace missing blanks in junction box @ port aft side of E.R.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Fire Fighting
Issued 16 March 1999 Resolved
Install smoke detectors in accommodations spaces.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Electrical
Issued 16 March 1999 Resolved
Repair and prove satisfactory operation of emergency lighting.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Documentation
Issued 16 March 1999 Resolved
Update vessel logs to reflect drills, lifesaving & EPIRB tests as required by 46 CFR part 185.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Documentation
Issued 17 July 1997 Resolved
Post Certificate of Inspection._x001C_
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 17 July 1997 Resolved
Stow life jackets for easy accessibility, remove personal gear/ fishing gear from lifejacket lockers.
Condition: Unknown
Due 17 July 1997
Resolved 18 July 1997
Navigation
Issued 9 June 1997 Resolved
Demonstrate proper operation of rudder angle indicator at steering station._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 13 June 1997
Navigation
Issued 9 June 1997 Resolved
Repair hydraulic leak in steering gear/windlass servo on after bulkhead of engine room. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 13 June 1997
Engineering
Issued 9 June 1997 Resolved
Provide illumination for bridge wing controls on port and stbd bridge wings_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 13 June 1997
Navigation
Issued 27 May 1997 Resolved
REPAIR AND PROVE PROPER OPERATION OF VESSEL'S STEERING SYSTEM IN ALL MODES OF OPERATION PRIOR TO HAVING THE COI RETURNED.
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997
Electrical
Issued 13 May 1997 Resolved
Remove any unused wiring from engine room. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 13 June 1997
Fire Fighting
Issued 13 May 1997 Resolved
Provide fixed fire protection system as well as a detection system and ventstops for the engine room. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Engineering
Issued 13 May 1997 Resolved
Prove proper operation of lube oil failure alarms for main propulsion engines._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Documentation
Issued 13 May 1997 Resolved
Provide an emergency station bill when vessel operates on overnight trips.
Condition: Unknown
Due 9 June 1997
Resolved 13 June 1997
Electrical
Issued 13 May 1997 Resolved
Provide blanks in electrical distribution sub panels in engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 18 April 1997 Resolved
MAKE WATERTIGHT BULKHEADS BOTH FORE AND AFT IN WAY OF ENGINE ROOM WATERTIGHT. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1997
Resolved 6 June 1997
Construction/Loadline
Issued 16 May 1996 Resolved
Make vessel available on drydock for structural hull exam and examination of damage to bow area.
Condition: Unknown
Due 16 May 1996
Resolved 19 June 1996
Electrical
Issued 12 April 1995 Resolved
Remove or repair secondary marine radar.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Engineering
Issued 12 April 1994 Resolved
RENEW MAIN ENGINE SUCTION RUBBER HOSES.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 12 April 1994 Resolved
SECURE THE RADIO WIRING IN CREW BERTHING.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Construction/Loadline
Issued 12 April 1994 Resolved
PROPERLY SECURE THE UNUSED OVERBOARD DISCHARGES IN THE ENGINEROOM, PORT ANDSTBD SIDE.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Fire Fighting
Issued 12 April 1994 Resolved
RENEW FIRE PUMP GAUGE IN THE ENGINE ROOM.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Accommodation/Occupational Safety
Issued 12 April 1994 Resolved
PROPERLY SECURE THE VENT FAN IN THE GALLEY. FAN INSTALLATION IS LOOSE, PROVIDE SCREEN FOR BLOWER INTAKE.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Documentation
Issued 12 April 1994 Resolved
PROVIDE PROOF OF CURRENCY WITH RANDOM DRUG TESTING AND PRE-EMPLOYMENT DRUG TESTING FOR THE CURRENT CREW.
Condition: Unknown
Due 31 May 1994
Resolved 2 May 1994
Documentation
Issued 2 April 1992 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47CFR80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC. VESSEL ROUTE LIMITED TO NOT MORE THAN 100 MILES OFF THE MAINLAND SHORE UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Lifesaving
Issued 2 April 1992 Resolved
HAVE BOTH 25 MAN LIFERAFTS SERVICED PRIOR TO 26 APRIL 92 AND RE-INSTALLED TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Lifesaving
Issued 3 April 1991 Resolved
REMOVE 2 INFLATABLE LIFE RAFTS TO CG APPROVED FACILITY FOR ANNUAL SERVICING. VESSEL ROUTE RESTRICTED TO COASTWISE VOYAGE NOT MORE THAT 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Lifesaving
Issued 30 May 1989 Resolved
PROVIDE 5 ADULT LIFE PRESERVERS FITTED WITH LIGHTS AND WHISTLES. VESSEL IS LIMITED TO 45 TOTAL PERSONS (CREW AND PASSENGERS) ON BOARD UNTIL CORRECTED.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Navigation
Issued 30 May 1989 Resolved
PROVE THE PROPER OPERATION OF THE STERN LIGHT.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Documentation
Issued 30 May 1989 Resolved
PROVIDE INLAND AND INTERNATIONAL NAVIGATION RULES BOOK ON BOARD.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Construction/Loadline
Issued 30 May 1989 Resolved
PROVIDE DOUBLE CLAMPS TO AFT BAIT TANK OVERBOARD DISCHARGE PENETRATING THE TRANSOM.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Engineering
Issued 30 May 1989 Resolved
INSTALL PROPERLY THE AFT FUEL TANK INCLUDING THE FILL, VENTS, SUPPLY AND RETURN LINES. PROPERLY GROUND THE SAME.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Lifesaving
Issued 13 May 1987 Resolved
PROVIDE 4 RED FLARES
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Fire Fighting
Issued 13 May 1987 Resolved
PROVE FIRE PUMP
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
PROVIDE 12 PARACHUTE FLARES
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
PROCURE 5 ADULT,1 CHILDS PFD
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Electrical
Issued 13 May 1987 Resolved
PROVIDE ELECTRICAL COVERS FOR SEWAGE PUMP MOTOR AND LIGHT SWITCH ON AFT ENGCOMP. BULKHEAD.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Electrical
Issued 13 May 1987 Resolved
WIRE ELECRTIC FIRE PUMP FOR REMOTE START/STOP OUTSIDE ER SPACE
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987 Resolved
PROVE ENGINE STOP FOR PORT ENGINE FROM BRIDGE
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Electrical
Issued 13 May 1987 Resolved
PROVE DECK PA SYSTEM
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987 Resolved
REATTACH GROUNDING WIRE ON AFT FUEL TANK
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Navigation
Issued 13 May 1987 Resolved
PROVIDE UP TO DATE CHARTS,LIGHT LIST,TIDE TABLES,COAST PILOT,AND TIDAL CURRENT TABLES
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
RESTOW INFLATABLE LIFE RAFTS
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Electrical
Issued 13 May 1987 Resolved
REPLACE BURNED WIRE TO SOLENOID IN STBD STATEROOM
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Navigation
Issued 13 May 1987 Resolved
PROVIDE COMPASS DEVIATION CARD
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
STENCIL NUMBER OF PFD'S STOWED IN STOWAGE BOXES.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 9 April 1987 Resolved
BOTH MAIN DIESEL ENGINES NEED GUARDS COVERING THE FRONT PULLEYS.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Unknown
Issued 9 April 1987 Resolved
RESEAL ENGINEROOM HATCH TO PREVENT SALT WATER FROM ENTERING.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Documentation
Issued 21 April 1986 Resolved
CONDUCT AN INSPECTION FOR CERTIFICATION
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Accommodation/Occupational Safety
Issued 21 April 1986 Resolved
PROVIDE METALLIC SHUT OFF VALVES ON BOTH SIDES OF REQUIRED WATERTIGHT BULKHEADS FOR ALL NON-METALLIC PIPING PENETRATIONS
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Accommodation/Occupational Safety
Issued 21 April 1986 Resolved
INSTALL METALLIC SHUT OFF VALVES IN THE NON-METALLIC PIPING PENETRATIONS OFTHE TRANSOM
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Engineering
Issued 21 April 1986 Resolved
REPLACE THE NON-METALLIC EXHAUST COOLING WATER LINES WITH METALLIC MATERIALS.
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Electrical
Issued 21 April 1986 Resolved
REPAIR OR REMOVE THE AFTER LAZARETTE LIGHT AND JUNCTION BOX
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Engineering
Issued 21 April 1986 Resolved
RENEW THE WASTED EXHAUST HOSE CLAMPS
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Construction/Loadline
Issued 21 April 1986 Resolved
PROVIDE HINGES OR A CAPTIVE CHAIN FOR THE ENGINEROOM HATCH
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Construction/Loadline
Issued 21 April 1986 Resolved
DEMONSTRATE THE FORE PEAK AND AFTER LAZARETTE HATCHES ARE WATERTIGHT.
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Electrical
Issued 21 April 1986 Resolved
PROVIDE GUARDS OVER THE LIGHT FIXTURES WITH EXPOSED BULBS
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Construction/Loadline
Issued 21 April 1986 Resolved
PLUG THE HOLES IN THE AFTER ENGINE ROOM BULKHEAD PORT AND STARBOARD SIDES
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Construction/Loadline
Issued 15 April 1985 Resolved
REPLACE GASKETS ON ALL MAIN DECK SCUTTLES PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Documentation
Issued 15 April 1985 Resolved
PROVIDE VALID UP TO DATE COMMUNICATIONS ACT SAFETY RADIOTELEPHONY CERTIFICATE PRIOR TO OPERATIONS WITH PASSENGERS.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Lifesaving
Issued 15 April 1985 Resolved
PROVIDE NEW BATTERIES IN ALL LIFE PRESERVER LIGHTS AND IN RING BUOY WATERLIGHT PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Lifesaving
Issued 15 April 1985 Resolved
PROVIDE CERTIFICATION OF EPIRB TESTING PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985

Casualty record · 1

3 December 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1714330
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.