Records from 1985 to 2001. Most recent: inspection, 6 April 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
6 April 2001
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1066466
23 December 1999
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1046767
30 April 1999
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1360918
26 February 1998
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 805963
26 February 1997
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 805962
26 February 1996
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1371441
20 February 1996
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1371440
12 October 1995
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 878300
25 May 1994
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1356660
25 May 1993
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1436766
5 May 1993
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373845
27 May 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 955155
19 May 1992
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1260438
4 June 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 942681
21 May 1991
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 941453
6 March 1991
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1309123
23 October 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 901679
28 August 1990
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 913306
8 June 1990
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 911294
21 May 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 920071
12 December 1989
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1222698
28 November 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1240778
18 November 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1023912
18 July 1985
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 984520
13 June 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1290882
7 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978005
Fire Fighting
Issued 23 December 1999
Resolved
PROVIDE FIXED FIREFIGHTING/DETECTION SYSTEM AS REQUIRED BY 46 CFR SUBCHAPTER T. VESSEL PROHIBITED FROM CARRYING MORE THAN 6 PASSENGERS UNTIL THIS REQUIREMENT IS CLEARED. CLEAR BY 31JAN00 OR COI MAY BE REVOKED.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Accommodation/Occupational Safety
Issued 21 May 1991
Resolved
Repair and prove operation of MSD system.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Electrical
Issued 21 May 1991
Resolved
Repair light in the women's head.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Deck/Cargo
Issued 21 May 1991
Resolved
Repair and prove operation of anchor winch.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Engineering
Issued 23 October 1990
Resolved
GRIND AND WELD FRACTURES NOTED ON BOTH AFT SHAFT BEARING STRUTS, DESIGNING A MORE ADEQUATE STRUT THAT WILL PREVENT THE FAILURE NOTED.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Electrical
Issued 23 October 1990
Resolved
REMOVE AND REPLACE THE SGT-60 DEGREE WIRE LEAD FROM THE GENERATOR SET TO THE TWO WAY SWITCH. REPLACING THE WIRE WITH AN APPROVED WIRE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Electrical
Issued 8 June 1990
Resolved
COMPLETE REMOVAL OF DEAD END WIRING & PROPERLY SUPPORT LOOSE WIRING.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 8 June 1990
Resolved
REPAIR DAMAGE TO HULL ON PORT SIDE BELOW RAIL NEAR AREA OF BESSEL BELL & ON STERN WHERE DAMAGED.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 8 June 1990
Resolved
REPLACE PLASTIC THRU-HULL FITTINGS WITH METALIC FITTINGS WITHIN 6" OF LWL PORT & STBD.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Engineering
Issued 8 June 1990
Resolved
REALIGN PLASTIC PIPE ON BILGE SUCTION LINE ON STBD ENG TO REMOVE KINK IN RUBBER HOSE.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Accommodation/Occupational Safety
Issued 8 June 1990
Resolved
PROVIDE OPERATION MANUAL FOR MARINE SANITATION DEVICE.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Fire Fighting
Issued 8 June 1990
Resolved
PROVIDE MARINE BRACKETS FOR B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Accommodation/Occupational Safety
Issued 8 June 1990
Resolved
PROVIDE SAFETY RAILS FOR STOVE TOP TO ADEQUATELY SECURE UTENSILS ON ALL BURNERS.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990
Resolved
PROVIDE AMMETER FOR BATTERY CHARGER IAW 46CFR 183.05020(F)
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990
Resolved
PROVE OPERATION OF GENERATOR & SYSTEM PRIOR TO USE AND PROVIDE DRAWINGS OF ELECTRICAL SYSTEM.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 8 June 1990
Resolved
PROVIDE SUITABLE POSITIVE LOCK TO SECURE ENG ROOM HATCH WHEN OPEN.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990