Records from 2008 to 2026. Most recent: operational control imposed, 1 February 2026.
Inspection history · 33
1 February 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8304645
1 February 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8305108
7 December 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8278798
7 December 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8279511
20 August 2025
Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8213765
8 May 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8131920
10 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8109129
29 September 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8011109
20 May 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7913414
9 March 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7876497
11 October 2023
Deficiency Check · In-Service Inspection · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7805969
30 August 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7781430
30 August 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7794106
30 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7700945
17 June 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7480374
16 June 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7480355
24 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7418116
29 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7358485
20 September 2021
Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7316252
29 July 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271956
6 May 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7190884
3 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7149778
28 January 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7132134
22 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7013076
22 March 2019
Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam · Construction Oversight · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6646868
22 March 2019
Deficiency Check · Administrative Inspection · Initial Certification · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6669704
1 January 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6627583
31 August 2018
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6528156
14 May 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6414015
8 February 2017
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6073980
5 October 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6016520
19 August 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5977323
15 March 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5840596
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel operator self-reported reduction in propulsion of the port side engine en-route to Pier 33 with 150 passengers. Provide a report detailing any damage or repairs conducted to the vessel and complete a satisfactory sea trial prior to the carriage of passengers.
46 CFR 119.200 (a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2026
Resolved 30 March 2026
Resolution: Manufacturer conducted repairs on port-clutch and transmission gearbox, repairs made to port-propeller and satisfactory sea trials conducted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires found in aft pilot house. Secure or remove to MI satisfaction.
46 CFR 120.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 24 April 2025
Resolution: Operator removed dead end wire.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 10 April 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Emergency instructions not available in the pilot house or at the operating station.
46 CFR 122.510(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 24 April 2025
Resolution: Operator posted station bill and emergency instructions in pilot house.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 10 April 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. MI identified faulty sewage tank sensor, causing flashing indicator light in the pilot house. Repair sensor to MI satisfaction.
46 CFR 115.840
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 24 April 2025
Resolution: Operator provided video to show functioning sensor indicator light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 April 2025
Resolved
Electrical equipment exposed to the weather must be watertight. MI observed missing screws on electrical cover and cracked electrical cover on the stbd aft upper deck. Repair/replace to MI satisfaction.
46 CFR 120.210(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 24 April 2025
Resolution: Operator replaced bolts and cracked electrical cover.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 April 2025
Resolved
Electrical equipment exposed to the weather must be watertight. MI observed 2 cable penetrations with missing/broken seals; repair to MI satisfaction.
46 CFR 120.210(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 8 May 2025
Resolution: MI attended vessel to verify repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 April 2025
Resolved
Except for continuously manned operating stations as allowed by paragraph (f) of this section, each accommodation space, control space, and service space must be fitted with the following systems: A smoke actuated fire detection system of a type approved by the Commandant that is installed in accordance with 46 CFR part 76. Fwd hallway aft of bathrooms equipped with heat detector instead of smoke detector. Fire control plan calls for smoke detector. Replace detector to MI satisfaction.
46 CFR 118.400(f)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 8 May 2025
Resolution: MI attended vessel to verify re-installation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 April 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Replace plastic trash cans throughout vessel.
46 CFR 116.405 (i)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2025
Resolved 8 May 2025
Resolution: Operator replaced all garbage cans with metal cans. MI attended to verify.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 April 2025
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically; towed in a way that permits manual release from its securing arrangements. MI identified IBA onboard with hydrostatic release and weak link. Operator removed unauthorized, extra, weak link during inspection.
46 CFR 117.130 (a)(2), (a)(4)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 April 2025
Resolution: Operator removed weak link during inspection.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 20 May 2024
Resolved
Repairs or alterations to the hull, machinery, or
equipment that affect the safety of the vessel must not
be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the
vessel..,alterations affecting stability. All galley
equipment was removed from the vessel without plan
review. Aluminum PORT/STBD main deck doors forward of
fire boundary were installed without plan review. Submit
plans to the satisfaction of MI for weight changes.
46 CFR 115.700(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 10 July 2024
Resolution: Cleared deficiency to the satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Identified water bottle collecting oil from port engine.
46 CFR 115.830
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 May 2024
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch on a vessel that operates only on protected waters. Forepeak hatch did not prevent water intrusion.
46 CFR 116.1160(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Identified electrical ports hanging off port and starboard engines, creating unsafe environment.
46 CFR 120.200
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 May 2024
Resolved
A door in a stairtower, stairway, and main vertical zone bulkhead must meet the following additional requirements: Holdback hooks are not allowed. If installed, a hold back mechanism for a door must allow the door to be released: Locally; Upon a signal from a control space; and Upon disruption of the power system. Fire control boundary doors were found to be held back by hooks preventing the doors to close automatically.
46 CFR 116.435(c)(6)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ventilation (Working spaces)
Issued 20 May 2024
Resolved
A space containing diesel machinery must be fitted with adequate means, such as drip proof ventilators, ducts, or louvers, to provide sufficient air for proper operation of main engines and auxiliary engines. Laz exhaust piping found to be wrapped with painters tape.
46 CFR 119.465(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 May 2024
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. A pilot house window is leaking.
46 CFR 116.1020
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 May 2024
Resolved
A weather tight door must be provided for each opening located in a deck house or companionway. Found deteriorated material around the window and bottom edge of starboard loading door.
46 CFR 116.1160(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 20 May 2024
Resolved
Annual audit of the VSP. For each annual audit, a letter certified by the Company Security Officer or the VSO stating the date the audit was completed. No record of annual audit.
33 CFR 104.235(b)(8)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 June 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 May 2024
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. Fire
control plan did not contain all required items.
46 CFR 116.530
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 8 August 2024
Resolution: Received email of corrected deficiency satisfactory to the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 August 2023
Resolved
Propulsion machinery must be suitable in type and design for propusion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of STBD Main Engine while underway. Complete cause analysis and effect repairs to satisfaction of Marine Inspector prior to carriage of passengers for hire.
46 CFR 119.200 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2023
Resolution: Found sheared tortional coupling on STBD engine. Replaced coupling, conducted 1.5 hr sucessful sea trial.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 March 2022
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. All hatches exposed to the weather require a lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 10 May 2022
Resolution: Photos proving lanyard was placed. Verbally notified 04/04/2022
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 March 2021
Resolved
Each Item of survival craft equipment must be good quality sufficient for the intended purpose. Vessel's bowsing lines for its IBA's were improperly rigged, which prevents automatic release.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2021
Resolved 3 March 2021
Resolution: Deficiency corrected on the spot. Bowsing lines re-rigged in accordance with manufacturer's instructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 July 2020
Resolved
Waste receptacles must be constructed of non-combustible materials with no opening in the sides or bottom. Vessel's waste receptacles found onboard were made out of plastic (combustible material). 46 CFR 116.405 (i)
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 August 2020
Resolved 21 September 2020
Resolution: Photos of metal cans provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 July 2020
Resolved
Portable and semi-portable extinguishers must be inspected and maintained IAW NFPA 10, which includes routine inspection and annual servicing by an approved facility. The owner or operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel's portable fire extinguisher was found to have an expired service tag. 46 CFR 115.810 (b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2020
Resolved 12 August 2020
Resolution: Extinguisher was serviced
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 22 July 2020
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Vessel's forward storage room was found to have a mold-like smell that appeared to come from its carpet/flooring. Vessel is required to sanitize/clean out the space prior to taking on passengers for hire. 46 CFR 115.818
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2020
Resolved 12 August 2020
Resolution: Carpet was cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 July 2020
Resolved
Ring life buoys shall be of first class workmanship and free from any defects materials affecting their appearance or serviceability. Vessel's forward ring life buoy was found to have a small fracture effecting its seaworthiness. 46 CFR 160.050-4 (f)
Action required: 705 - Other - as specified
Due 22 August 2020
Resolved 12 August 2020
Resolution: Extra lifering was removed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2020
Resolved
Rugs and carpets are not permitted in machinery spaces, high risk service spaces, or areas where the spillage or leakage of flammable or combustible liquids is possible including areas immediately adjacent to bar service areas. Remove carpet immediately near the bar.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 August 2021
Resolved 24 March 2022
Resolution: Bar carpet is in compliance with regulations. Bar does not carry 80 proof or above alcohol.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Provide a Non-Tank Vesssel Response Plan with a valid approval letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 26 February 2021
Resolution: Verified NTVRP on Homeport.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Provide a third party tech report of the load testing for the new gen-sets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Provide a third party tech report of the sea trials for the new main diesel engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Provide MSC approval letters for DVTPs and QFAs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2019
Resolution: Final approval letter received.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2019
Resolved
Repair/replace audible alarm for bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 30 May 2019
Resolved
Install an alarm for the failure of the steering gears to audibly and visually alarm in the pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Provide MSC approval letter for steering hydraulic plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 15 July 2019
Resolution: Updated MSC approval received Ser: E2-1902294
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Provide alternate security plan and approval letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019
Resolved
Update labels within all fuse boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 May 2019
Resolved
Properly mount all IBAs in a float-free arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2019
Resolved
Install accurate markings for all life jacket stowage locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 May 2019
Resolved
Repair/replace all failing emergency lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 31 August 2018
Resolved
Conduct U/W fire and Manoverboard drills to the satisfaction of an attending Coast Guard marine inspector. This office understands that the pending drillswill be conducted as part of the New-to-Zoneand new Ownership process.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2018
Resolved 19 June 2019
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 May 2018
Resolved
O/Op failed to have the vessel inspected within the 3 month window. COI deactivated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2018
Resolved 19 June 2019
Electrical › Electric Generation Source (service) › Generator
Issued 19 August 2016
Resolved
Provide technician service report attesting to the repairs associated with the oil/water mixture in the Starboard Generator exhaust system. The service report must identify the cause of the oil/water mixture in the exhaust system - 46 CFR 183.200 (a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2016
Resolved 2 September 2016
Resolution: Rcvd tech report attesting to the repair. Witnessed operational test under load of generator. All sat.
Electrical › Electric Generation Source (service) › Generator
Issued 19 August 2016
Resolved
Provide technician service report attesting to the repairs associated with the oil/water mixture in the Center Generator exhaust system. The service report must identify the cause of the oil/water mixture in the exhaust system - 46 CFR 183.200 (a).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2016
Resolved 2 September 2016
Resolution: Rcvd tech report attesting to repair. Witnessed operational test under load of generator. All Sat
Electrical › Electric Generation Source (service) › Generator
Issued 19 August 2016
Resolved
Provide technician service report attesting to the repairs associated with the oil/water mixture in the Port Generator exhaust system. The service report must identify the cause of the oil/water mixture in the exhaust system - 46 CFR 183.200 (a).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2016
Resolved 2 September 2016
Resolution: Rcvd tech report attesting to repair. Witnessed operational test under load of generator. All Sat