Records in 1999. Most recent: inspection, 15 September 1999.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 15 September 1999
Resolved
INDICATE ON CARGO SHIP SAFETY CONSTRUCTION CERTIFICATE WHETHER OR NOT EXEMPTION HAS BEEN ISSUED NLT 15 OCT 99. PROVIDE COPY OF CERTIFICATE TO NEAREST MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Piloting/Steering › Azimuth
Issued 15 September 1999
Resolved
REPAIR LEAK ON PORTSIDE STEERING RAM NLT 15OCT99 TO THE SATISFACTION OF CLASS. PROVIDE CLASS REPORT TO NEAREST MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 1999
Resolved
INSTALL PROTECTIVE COVER OVER EXPOSED LIGHT BULB IN STEERING COMPARTMENT NLT 15 OCT 99
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 September 1999
Resolved
PROVIDE MANEUVERING FACTS SHEET WITH WARNING STATEMENT IAW 33 CFR 164.35
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 15 September 1999
Resolved
PROVIDE 4 NEW CHARGES FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 15 September 1999
Resolved
INDICATE ON CARGO SHIP SAFETY RADIO CERTIFICATE WETHER OR NOT EXEMPTION CERTIFICATE HAS BEEN ISSUED, NLT 15OCT99.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 September 1999
Resolved
PROVIDE CURRENT U.S. COAST PILOT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 September 1999
Resolved
REPLACE PIPING THAT HAS SOFT PATCH INSTALLED ON DECK DRAIN PIPING LOCATED IN STEERING ROOM PORT OUTBOARD SIDE, NO LATER THAN 150CT99.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 1999
Resolved
REMOVE UNUSED AND EXPOSED WIRES TO HOT WATER HEATER IN ENGINE ROOM NO LATERTHAN 15OCT99 TO THE SATISFACTION OF CLASS. PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 15 September 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Fire Main › Condition
Issued 15 September 1999
Resolved
REPAIR EMERGENCY FIRE PUMP EXHAUST LEAK TO THE SATISFACTION OF CLASS NO LATER THAN 15OCT99. PROVIDE CLASS REPORT TO THE NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Piloting/Steering › Azimuth
Issued 15 September 1999
Resolved
PROVIDE AN EMERGENCY STEERING PIPING AND VALVE DIAGRAGM TO THE SATISFACTIONOF THE ATTENDING CLASS SURVEYOR, NO LATER THAN 15OCT99. PROVIDE A CLASS REPORT TO THE NEAREST USCG MSO.
Condition: Unknown
Due 6 October 2004
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 1999
Resolved
REPAIR LEAKING ACCESS COVER TO THE AFT BALLAST TANK TO THE SATISFACTION OF CLASS, NO LATER THAN 15OCT99. PROVIDE CLASS REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Piloting/Steering › Azimuth
Issued 15 September 1999
Resolved
INSTALL HANDLE ON HYDRAULIC VALVE USED TO SHIFT TO MANUAL STEERING NO LATER THAN 15OCT99. COMPLETE TO THE SATISFACTION OF CLASS, PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Piloting/Steering › Azimuth
Issued 15 September 1999
Resolved
REPAIR EMERGENCY STEERING HYDRAULIC TRICK WHEEL CONTROL NO LATER THAN 15 OCT 99, TO THE SATISFACTION OF CLASS. PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Lifesaving
Issued 15 September 1999
Resolved
PRIOR TO DEPARTING PIER 14, PORT OF SAN JUAN, PR, PROVIDE CLASS REPORT ATTESTING TO THE PROPER OPERATION OF THE PORT AND STBD LIFEBOAT FALLS INCLUDING RELEASE HOOKS, FALLS GRIPES, AND BOAT GRIPES IAW SOLAS 60, CH- III, REG 36.
Condition: Unknown
Due 15 September 1999
Resolved 1 October 1999
Fire Fighting › Fire Main › Condition
Issued 15 September 1999
Resolved
PRIOR TO ENTERING U.S. WATERS PROVIDE REPORT FROM THE ATTENDING CLASS SURVEYOR THAT EMERGENCY FIRE PUMP HAS BEEN REPAIRED IAW SOLAS 60, REG 65, CH-II(b)(ii). PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 30 September 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting
Issued 15 September 1999
Resolved
PRIOR TO DEPARTING PIER 14, PORT OF SAN JUAN, PR, PROVIDE CLASS REPORT ATTESTING TO PROPER DEMONSTRATION OF A SUCCESSFUL FIRE DRILL IN ACCORDANCE SOLAS 74 AS AMENDED, CH-III REG 53.
Condition: Unknown
Due 15 September 1999
Resolved 1 October 1999
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 1999
Resolved
INSTALL COVERS OVER EXPOSED LIGHT BULBS IN ENGINE ROOM LIGHTING TO THA SATISFACTION OF CLASS, NO LATER THAN 15OCT99. PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 15 September 1999
Resolved
REPIAR LEAKING AUXILIARY ENGINE SEA WATER COOLING PUMP TO THE SATISFACTION OF CLASS NO LATER THAN 15 OCT 99. PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Fire Main › Condition
Issued 15 September 1999
Resolved
REPAIR LEAKS ON BOTH #1 AND #2 FIRE PUMPS TO THE SATISFACTION OF CLASS NO LATER THAN 15 OCT 99. PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 September 1999
Resolved
REMOVE AND PROPERLY DISPOSE OF OLD UNUSED BATTERIES IN EMERGENCY BATTERY ROOM TO THE SATISFACTION OF CLASS NO LATER THAN 15OCT99. PROVIDE REPORT TO NEAREST USCG MSO.
Condition: Unknown
Due 15 October 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.